• Title/Summary/Keyword: 초음파 응답

Search Result 60, Processing Time 0.037 seconds

Study on the Nonlinear Electromagnetic Acoustic Resonance Method for the Evaluation of Hidden Damage in a Metallic Material (금속 재료의 잠닉손상 평가를 위한 비선형 전자기음향공진 기법에 관한 연구)

  • Cho, Seung-Wan;Cho, Seung-Hyun;Park, Choon-Su;Seo, Dae-Cheol;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.277-282
    • /
    • 2014
  • Recently, much attention has been paid to nonlinear ultrasonic technology as a potential tool to assess hidden damages that cannot be detected by conventional ultrasonic testing. One nonlinear ultrasonic technique is measurement of the resonance frequency shift, which is based on the hysteresis of the material elasticity. Sophisticated measurement of resonance frequency is required, because the change in resonance frequency is usually quite small. In this investigation, the nonlinear electromagnetic acoustic resonance (NEMAR) method was employed. The NEMAR method uses noncontact electromagnetic acoustic transducers (EMATs) in order to minimize the effect of the transducer on the frequency response of the object. Aluminum plate specimens that underwent three point bending fatigue were tested with a shear wave EMAT. The hysteretic nonlinear parameter ${\alpha}$, a key indicator of damage, was calculated from the resonance frequency shift at several levels of input voltage. The hysteretic nonlinear parameter of a damaged sample was compared to that of an intact one, showing a difference in the values.

Development of Ultrasound Diagnostic System for Functional Gastrointestinal Disorders using Finite Difference Method (유한차분법을 이용한 기능성 위장 장애 진단용 초음파 시스템의 개발)

  • Park, Won-Pil;Woo, Dae-Gon;Ko, Chang-Yong;Lee, Qyoun-Jung;Lee, Yong-Heum;Choi, Seo-Hyoung;Shin, Tae-Min;Kim, Han-Sung;Lim, Do-Hyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.9
    • /
    • pp.130-139
    • /
    • 2007
  • The disaster from functional gastrointestinal disorders (FGID) has detrimental impact on the quality of life of the affected population. There are, however, rare diagnostic methods for FGID. Our research group identified recently that the gastrointestinal tract well of the patients with FGID became more rigid than that of healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The objective of the current study is, therefore, to identify feasibility of a diagnostic system for FGID based on ultrasound technique, which can quantify the characteristics above. Two-dimensional finite difference (FD) models (one normal and two rigid models) were developed to analyze the reflective characteristic (displacement) on each soft-tissue layer responded after application of ultrasound signals. Based on the results from FD analysis, the ultrasound system for diagnosis of the FGID was developed and clinically tested via application of it to 40 human subjects with/without FGID who were assigned to Normal and Patient Groups. The results from FD analysis showed that the maximum displacement amplitude in the rigid models (0.12 and 0.16) at the interface between the fat and muscle layers was explicitly less than that in the normal model (0.29). The results from actual specimens showed that the maximum amplitude of the ultrasound reflective signal in the rigid models $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal model $(0.1{\pm}0.0Vp-p)$. Clinical tests using our customized ultrasound system showed that the maximum amplitudes of the ultrasound reflective signals near to the gastrointestinal tract well for the patient group $(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group $(0.1{\pm}0.2Vp-p)$. These findings suggest that our customized ultrasound system using the ultrasound reflective signal may be helpful to the diagnosis of the FGID.

Research and consideration on the evaluation of usability formation of focused ultrasonic stimulation systems (집속형 초음파 자극 시스템의 사용적합성 형성평가에 대한 연구 및 고찰)

  • Kim, Jun-tae;Kim, Ju-hee;Joo, Kyu-tai;Kim, Kyung-ah;Ryu, Ok-su;Jo, Jae-hyun;Jeong, Jin-Hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.164-177
    • /
    • 2022
  • Medical device usability evaluation refers to the evaluation of medical devices through actual users before the final prototype production is completed. IEC 62366, one of the international safety standards for electronic medical devices, is a standard that must be applied to obtain medical device licenses in major advanced countries such as Europe and the United States. In Korea, through the Ministry of Food and Drug Safety's notice, from January 2021, sequential application by grade has been implemented. In this study, 15 participant specialists were recruited through the Incheon G University Hospital Medical Device Convergence Center for formative evaluation during user suitability evaluation of the focused ultrasound stimulation system being developed by Icleo Co., Ltd., and the test was conducted through joint scenario development. . In the result of task performance, the performance rate was 90.67%, and after the completion of the performance, 86.67% of 'Easy user interface' and 94% of 'Identification/Readability/Understanding of information' questions in the participant survey results analysis by question. The response rate was above average.

Piezoelectric Properties of Lead-free $Ba(Ti_{0.8}Zr_{0.2})O_3-(Ba_{0.7}Ca_{0.3})TiO_3$ Ceramics for Haptic piezoelectric Actuator (햅틱 압전 액츄에이터용 $Ba(Ti_{0.8}Zr_{0.2})O_3-(Ba_{0.7}Ca_{0.3})TiO_3$ 무면 세라믹스의 압전특성)

  • Park, Min-Ho;Lee, Kab-Soo;Yoo, Ju-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.304-304
    • /
    • 2010
  • 최근 생활에 편리하며 휴대하기 좋은 전자기기들이 개발되고 있다. 휴대폰이나 MP3와 같은 전자기기들은 거의 필수품이라고 할 정도로 우리의 일상생활에 근접하여 있다. 그 종 대표적으로 휴대폰의 종류로 스마트폰과 같은 터치스크린을 이용한 사례는 점차 상승하고 있으며 시간이 지날수록 그 수요는 더욱 많아지고 있다. 때문에 몰입감 제공을 위하여 햅틱장치의 채용이 일반화 되고 있다. 햅틱장치란 가상환경이나 원거리에 있는 환경과 사용자가 상호 작용할 때 사용자에게 촉감이나 힘의 정보를 전달하여 주는 장치로 진동 및 회동 저항에 의해 사용자로 하여금 촉감들 느낄 수 있도록 하는 장치를 뜻한다. 즉, 현실감을 전달을 중점으로 하는 햅틱장치는 빠른 응답 속도와, 진동의 주파수와 크기는 독립적으로 제어가 가능해야 하며 기계적 수용기들을 직접적으로 자극할 수 있어야 한다. 하지만 모바일 햅틱장치의 경우 크기 및 소비전력의 문제로 모든 스펙을 만족하기에는 어려워 좀 더 한정적인 느낌을 제공할 수 없다. 현재까지 모바일 장치에서 햅틱 피드백을 위하여 진동모터나, 솔레노이드, 압전 액츄에이터 등이 많이 사용되어 지고 있다. 그 중 압전 액츄에이터는 입력에너지를 기계적 출력에너지로 변환되는 효과를 이용 한 것으로 압력 센서, 초음파 센서 등 많은 분야에서 응용되고 있으며 변위 범위는 작지만, 크기가 매우 작고 변위 정밀도가 높으며 발생력과 응답속도가 빠르다는 장점이 존재한다. 이를 이용한 햅틱 압전 엑츄에이터의 제작에 사용되는 압전 세라믹스는 높은 전기적 특성을 가질수록 더 졸은 효율을 가지며 이로 인하여 보다 좋은 전기적 특성을 가지는 압전 세라믹스를 필요로 한다. 현재 많이 사용되는 PZT계 세라믹스는 우수한 전기적 특성으로 많이 사용되고 있지만 Pb의 유독성으로 인한 환경문제로 Pb가 포함된 제품을 제한하고 있어 현재 Lead-free의 연구가 이루어지고 있다. Lead-free중 Ba$(Ti_{0.8}Zr_{0.2})O_3$(BZT)는 PZT계 세라믹스를 대체할 차세대 압전 재료로 주목받고 있다. 일반적으로 Lead-free의 압전계수($d_{33}$=100~300pC/N)는 비교적 낮은 값을 보이지만 BZT의 압전계수(BZT $d_{33}$~620pC/N)는 PZT계 세라믹스의 압전계수($d_{33}$=500~600pC/N)와 비교하여 부족하지 않은 압전계수를 보여주며 PZT를 대체할 재료로 주목받고 있다. 본 실험은 햅틱 압전 엑츄에이터용 무연 압전세라믹스의 제작을 위하여 Ba$(Ti_{0.8}Zr_{0.2})O_3-(Ba_{0.7}Ca_{0.3})-TiO_3$(BZT -BCT)의 조성으로 유전 및 압전 특성을 조사하였다.

  • PDF

Gas sensing characteristics of SWNT(single walled carbon nanotube) sheet (탄소나노튜브의 가스 감응 특성)

  • 김민주;이상태;전희권;허증수
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.136-136
    • /
    • 2003
  • 카본나노튜브는 상용되는 기존의 센서에 비해 표면적이 넓어 감도가 놀고 응답속도가 빠르다. 또한 나노 스케일의 크기를 가지므로 고직접화를 실현할 수 있으며 기능복구성이 뛰어나 상온동작을 통한 저전력화가 가능하다. 본 실험에서는 아크방전법으로 합성한 카본나노튜브를 가스센서로 제작하여 상온에서 NH$_3$, NO 가스와의 반응 특성을 평가하였다. 또한 origin soot와 이를 정제한 purified CNT를 SEM(주사전자현미경), TEM(투과전자현미경), Raman scattering spectroscopy(라만 산란 분광기)를 통해 재료적 특성을 조사하고 이를 가스 감응 곡선과 연관하여 비교, 분석하였다. 전극에 CNT막을 형성시키기 위해 3g의 N,N dimethylformamide 용액에 CNT 10mg을 분산시킨 후 2시간동안 초음파 처리하였다. 이 용액을 mask를 이용해 전극 위에 막을 형성시킨 후 20$0^{\circ}C$에서 열처리하였다. 이렇게 제조된 origin soot와 purified CNT센서는 flow system을 이용하여 측정하였고 $N_2$분위기 하에서 센서를 안정화시킨 후 측정가스와의 반응을 살펴보았다 센서의 반응속도, 회복속도, 감도 등의 측정결과 origin soot는 NH$_3$ 25ppm에서 20%, purified CNT는 1%의 감도를 보여 20배 높은 감도를 보았다. NO 25ppm의 경우에도 origin soot가 8%, purified CNT는 0.8%의 감도를 보여 10배 높은 감도를 보였다. 이는 탄소입자가 많은 origin soot가 purified CNT 보다 표면적이 넓어 보다 많은 가스 흡착 싸이트를 가지기 때문이다. 하지만 origin soot는 반응시간과 회복속도가 Purified CNT 보다 2배 이상 느려 표면적 증가에 따른 가스 흡착과 탈착 능력이 떨어짐을 알 수 있었다. 또한 CNT와 가스사이의 전하 이동 방향에 따라 NH$_3$는 양의 감도를 NO는 음의 감도를 보였다 이는 전하의 이동 방향에 따라 전하와 캐리어 사이의 결합 및 해리가 일어나게 되고 결국 카본나노튜브 내의 캐리어 수를 증감시킴에 따라 나타나는 현상이다. 이러한 가스의 감도는 농도에 따라 증가하였으며 origin soot를 이용하여 1ppm이하의 NH$_3$ 가스를 검출할 수 있었다.

  • PDF

Positioning Recognition and Speed Control of Moving Robot at Indoor (실내 이동 로봇의 위치 인식 및 속도 제어에 관한 연구)

  • Shin, Wee-Jae;Jeong, Rae-Won
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.1
    • /
    • pp.88-91
    • /
    • 2010
  • In this paper, We are composed the position recognition and speed control using the moving robot in the shield Room with a RF Module and Ultrasonic Sensors. Double look up tables are selected a reference value/duty ratio. The moving robot with the dual fuzzy rules which can decrease a Conversion time than basic fuzzy control rules at start point and curve region. Also, a changing times of double look up table are rise at specific points b1,c1,d1 in the e-${\Delta}e$ phase plane and the one of the look up table is used which for increase rising time at transition area, the other used for rapidly conversion to the reference value. We verified that a dual fuzzy control rules get the good response compare with the basic fuzzy control rule.

Design of Gastrointestinal Diagnosis System based on Ultrasonic Response Characteristics (초음파 응답특성 분석에 의한 위장 경화 진단시스템의 설계)

  • Lim, Do-Hyung;Kim, Eun-Geun;Lee, Gyoun-Jung;Park, Won-Pil;Kim, Han-Sung;Shin, Tae-Min;Choi, Seo-Hyung;Lee, Yong-Heum
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.250-257
    • /
    • 2007
  • Functional gastrointestinal disorders affect millions of people of all age regardless of race and sex. There are, however, rare diagnostic methods for the functional gastrointestinal disorders because functional disorders show no evidence of organic and physical causes. Our research group identified recently that the gastrointestinal tract well in the patients with the functional gastrointestinal disorders becomes more rigid than healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The aim is, therefore, to develop a diagnostic method for the functional gastrointestinal disorders based on quantitative measurement of the rigidity of the gastrointestinal tract well using ultrasound technique. For this purpose, a preliminary ultrasound diagnostic system was developed and verified through phantom tests. The system consisted of transmitter, ultrasonic transducer, receiver, TGC, and CPLD, and verified via a phantom test. For the phantom test, ten soft-tissue specimens were harvested from porcine. Five of them were then treated chemically to mimic a rigid condition of gastrointestinal tract well, which was induced by functional gastrointestinal disorders. Additionally, the specimens were tested mechanically to identify if the mimic was reasonable. The customized ultrasound system was finally verified through application to human subjects with/without functional gastrointestinal disorders(Normal and Patient Groups). It was identified from the mechanical test that the chemically treated specimens were more rigid than normalspecimen. This finding was favorably compared with the result obtained from the phantom test. The phantom test also showed that ultrasound system well described the specimen geometric characteristics and detected an alteration in the specimens. The maximum amplitude of the ultrasonic reflective signal in the rigid specimens $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal specimens $(0.1{\pm}0.0Vp-p)$ (p<0.05). Clinical tests using our customized ultrasound system for human subject showed that the maximum amplitudes of the ultrasonic reflective signals nea. to the gastrointestinal tract well for the patient group$(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group$(0.1{\pm}0.2Vp-p)$ (p<0.05). These results suggest that newly designed diagnostic system based on ultrasound technique may diagnose enough the functional gastrointestinal disorders.

Implementation of a Person Tracking Based Multi-channel Audio Panning System for Multi-view Broadcasting Services (다시점 방송 서비스를 위한 사용자 위치추적 기반 다채널 오디오 패닝 시스템 구현)

  • Kim, Yong-Guk;Yang, Jong-Yeol;Lee, Young-Han;Kim, Hong-Kook
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.150-157
    • /
    • 2009
  • In this paper, we propose a person tracking based multi-channel audio panning system for multi-view broadcasting services. Multi-view broadcasting is to render the video sequences that are captured from a set of cameras based on different viewpoints, and multi-channel audio panning techniques are necessary for audio rendering in these services. In order to apply such a realistic audio technique to this multi-view broadcasting service, person tracking techniques which are to estimate the position of users are also necessary. For these reasons, proposed methods are composed of two parts. The first part is a person tracking method by using ultrasonic satellites and receiver. We could obtain user's coordinates of high resolution and short duration about 10 mm and 150 ms. The second part is MPEG Surround parameter-based multi-channel audio panning method. It is a method to obtain panned multi-channel audio by controlling the MPEG Surround spatial parameters. A MUSHRA test is conducted to objectively evaluate the perceptual quality and measure localization performance using a dummy head. From the experiments, it is shown that the proposed method provides better perceptual quality and localization performance than the conventional parameter-based audio panning method. In addition, we implement the prototype of person tracking based multi-view broadcasting system by integrating proposed methods with multi-view display system.

  • PDF

Survey for Diagnostic Radiography Examination in Veterinary Hospital (동물병원 영상의학적검사 실태조사)

  • Lee, Won-Jeong;Jo, Sung-Mi
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.177-184
    • /
    • 2022
  • The purpose of this study is surveyed diagnostic radiography (DR) examination in veterinary hospital (VC) including non-ionization radiation such as ultra-sonography and magnetic resonance imaging. From June 1 to June 20. 2021, we surveyed the VC in 00 metropolitan city by using a structural questionnaire which are location of VC and X-ray unit et al.. Data are expressed as a mean with standard deviation for continuous variable or percent for categorical variable using SPSS ver. 26.0. As the first animal to be visited, dogs were the highest with 61.9%, followed by cats with 12.9%. In 87.1% fo cases, DR units were used, and 4 VCs did not. In 27 VCs using DR units, 48.1% separated examination room and control room, 19.8% examined in animal visited, protective clothing was in all VCs, 55.6% were measured radiation exposure dose, 92.6% was responded a necessary for examination education. From the above results, it will help to revise the guidelines for DR units and examination in korea VCs.

The Study on the Perceptions of Radiological Technologist in Medical Imaging Equipment Used by the Oriental Doctor (한의사의 의료영상장비 사용에 대한 방사선사의 인식도)

  • Choi, Jae-Ho;Kang, Gi-Bong;Kim, Sang-Hyun;Kim, Tae-Hee;Kim, Gyoo-Hyung;Lee, Mi-Hwa;Ahn, Jung-Seong;Hong, Seong-Wan;Lee, Jae-Seok;Kwon, Ick-Su;Park, Jae-Yoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.109-120
    • /
    • 2017
  • In order to examine how Radiological Technologists perceive the oriental doctor's use of Medical Imaging Equipment, surveys were conducted for the members of the Korean Radiological Technologists Association. The total number of respondents were 515 and 481, with 34 insincere responses removed caused of nonvalidated answer. The results of the analysis are as follows. Although there were no statistical significance in the difference in perception by location of residence, work place, and educational background, respondents with higher education showed a tendency to agree on the use of comprehensive medical imaging equipment, but tended to oppose the use of special medical imaging equipment. Differences in perception by gender showed a greater negative perception toward the oriental doctor's use of medical imaging equipment by women than men. In particular, women showed more negative tendency for oriental doctor's use of special medical imaging equipment such as MRI, CT, and ultrasound equipment compared to men, and this was statistically significant. The difference in perception by age showed that the oriental doctor's use of medical imaging equipment was negative in the 20~30s, neutral in the 40~50s, and positive in the 60s, which were statistically significant. The difference in perception by work experience showed that the longer the work experience was, the more positive it was toward oriental doctor's use of medical imaging equipment. Specifically, the most favorable tendency was found with work experience of more than 30 years, which was statistically significant. The results of this study revealed the Radiological Technologists' perceptions on the oriental doctor's use of Medical Imaging Equipment and this can contribute to the direction of public health promotion in the future.