• Title/Summary/Keyword: 초음파 온도상승

Search Result 33, Processing Time 0.03 seconds

A Study on Changes in Body Surface Temperature and Thermal Effect According to Ultrasound Mode (초음파 진단모드에 따른 체표면 온도변화와 열효과에 관한 고찰)

  • Yang, Sung-Hee;Lee, Jin-Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.213-218
    • /
    • 2017
  • Recently, as the number of high-risk pregnancies increases, the use of new techniques such as Doppler, which have higher acoustic power than in the past, has been increasingly used in prenatal diagnosis and guidelines have been set up by various organizations to prevent excessive exposure. Therefore, in this study, we tried to investigate the temperature change of the body surface for each test mode according to the long time ultrasound examination and to examine the exposure time which is not influenced by the thermal effect. B mode, C mode, and PD mode according to time, and the temperature difference between exposed and unexposed sites were compared. As a result, the B mode showed a significant difference in the temperature change from 10 minutes, 50 minutes after exposed, 20 minutes from the C mode, and 30 minutes from the PD mode (p<0.01). In all three modes, the temperature difference was different (p<0.000), and PD mode was the most sensitive to temperature change. Also, it was found that the temperature rise time was shortened with the increase of the ultrasonic exposure time. Therefore, it is recommended that ultrasonography to observe the embryo or fetus should be used only for diagnostic purposes, avoiding excessive test time.

Experimental Analysis on Regularities of Synergistic Interaction of Temperature with Physico-Chemical Environmental Factors (온도와 물리화학적 환경요인에 의한 상승작용의 규칙성에 관한 실험적 고찰)

  • 김진규;신해식;블라디슬라프페틴;이영엽
    • Korean Journal of Environmental Biology
    • /
    • v.20 no.2
    • /
    • pp.165-172
    • /
    • 2002
  • The combined action of two factors on organisms can be either antagonistic, non-effective, additive or synergistic. Although synergism is of biological importance, the common features of synergistic interaction between harmful environmental factors are largely unknown. The purpose of this study is to establish general rules describing the response of various organisms to the combined action of heat with another inactivating agent. Synergistic interaction due to the simultaneous treatment of hyperthermia with ionizing or non-ionizing radiation has been analyzed using the experimental data mainly obtained with yeast cells. In addition, the results reported by others for viruses, bacterial spores, cultured mammalian cells, plants and animals were also analyzed to check the regularities revealed. The common rules of the synergistic interaction obtained in this study can be summarized as follows. For any constant rate of exposure, the synergy can be observed only within a certain temperature range. An increase in exposure rate resulted in an increase of this specific temperature and vice versa. For a constant temperature at which the irradiation occurs, synergy can be observed within a certain dose rate range. As the exposure temperature is reduced, the optimal intensity decreases and vice versa. A new conception taken into consideration those regularities can make a clue for environmental disaster preventive analysis of the synergy of radiation with the other factor.

Driving Properties of Diesel Injection System using the Multilayer Actuator Structured-ultrasonic Nozzle (적층액츄에이터형 초음파 노즐을 이용한 경유분사 시스템의 구동특성)

  • Kim, Do-Hyung;Kim, Hwa-Soo;Kang, Jin-Hee;Lee, Yu-Hyong;Hwang, Lark-Hoon;Yoo, Ju-Hyun;Hong, Jae-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.174-174
    • /
    • 2008
  • 초음파를 이용하여 액체 연료를 분사하면 균일한 입경과 미립화가 우수하며 에너지 절약과 공해방지등을 할 수 있다. 또한 유속과 유량에 관계없이 이용할 수 있어 반도체 분야의 웨이퍼와 평판 표시기상에 사진 석판용 화학물질의 균일도포 컴퓨터 하드 디스크의 광택제 도포등에 사용할 수 있다. 이처럼 초저의 유출 용량을 요구하는 모든 공정 및 액체연료의 분사가 요구되는 모든 산업에 적용할 수 있는 장점을 가지고 있다. 하지만 현제까지 주로 사용되고 있는 초음파노즐의 액츄에이터는 단판액츄에이터형로 높은 교류전압을 인가해주어야 하는 단점을 가지고 있다. 이 단점을 해결하기 위해 적층액츄에이터형을 사용하여 초음파 노즐 구동하면 낮은 교류 입력전압에서도 단판액츄에이터형 초음파 노즐과 같은 특성을 가질 수 있다. 또한 초음파 노즐의 구동시 기계적인 진동을 이용하므로 많은 열을 발생시켜 노즐의 온도가 상승하여 세라믹 액츄에이터에도 그 영향을 미치게 되어 열적 열화 현상이 일어날 수 있기에 높은 큐리온도를 가지는 액츄에이터가 필요하다. 본 실험에서는 $Pb(Mn_{1/3}Nb_{2/3})_{0.02}(Ni_{1/3}Nb_{2/3})_{0.12}(Zr_{0.50}Ti_{0.50})_{0.86}O_3$ 조성을 사용하여 $900^{\circ}C$의 저온에서 액상 소결하여 적층혈액츄에이터를 제작하였으며 압전 및 유전 특성을 조사하였다. 제작된 초음파노즐을 구동하기 위해서는 약 36kHz의 30V이상의 교류입력전압 할 수 있는 구동회로가 필요로 한다. 압전액츄에이터의 구동을 위해서는 정확한 정현파 입력이 필요 없다. 압전액츄에이터의 특성상 유사 정현파 입력 만으로도 임피던스 매칭이 이루어지기 때문에 설계가 쉽고 간편한 Push-Pull 방식을 이용한 PWM인버터를 사용하였고 인버터의 출력 주파수를 34~38kHz까지 가변 할 수 있게 설계하였다. 제작된 적층액츄에이터형 초음파 노즐을 PWM인버터로 실제 액체 연료인 경유를 분사하였을 때의 액츄에이터의 온도 변화에 따른 공진주파수와 온도 의존성, 전기적 특성을 조사하고 미립화 분사되는 경유의 미립자 크기 및 최대 분사량을 조사 하였다.

  • PDF

A Study on the Intensity Measurng of Ultrasonics by Added Two Sensive point of Thermocouple (이감온점 열전대에 의한 초음파의 강도측정에 관한 연구)

  • Kim, Ju-Hong;Lee, Dong-Hwi;O, Yeong-Don
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.6
    • /
    • pp.1-7
    • /
    • 1971
  • This paper describes concerning the method of measurement for the intensity of ultrasonics in liquid. The probe which is added two sensive point of thermocople which is surrounded by the absorbed material of sonic wave on the both side of the refleftite plate have measured the intensity of ultrasonics indirectly by the difference of the temperature of two sensive point which had raised the temperature by the sonic wave and its reflective wave which transmitted the ultrasonic energy. This minify the influence from the temparature of liquid and time constant. Consequently, this is the basic industrial method which is with in the bounds of possibility on the simple measurement of the intensity of the local ultrasonics concerning direction of its propagation.

  • PDF

A study on the slip-up speed of a shaft using heating slip form (히팅슬립폼을 적용한 수직구 구조물의 상승속도에 관한 연구)

  • Ko, Eomsik;Lee, Sanghun;Park, Jongpil;Zi, Goangseup;Kim, Changyong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.811-823
    • /
    • 2019
  • Slip form method is applied to many cases of a shaft these days because it is safer, more economical and faster than cast-in-place method. Slip-up height of the method is approximately 2.5 to 4.0 m/day. If the temperature of concrete is outside the range of 10 to 30℃, the effects of changes in strength or elastic characteristics are significant. Therefore, it is difficult for slip-up speed to be higher than 3 m/day during winter construction. In addition, concrete has heat caused by hydration, which causes temperature cracking of hardened concrete. Therefore, temperature control of concrete curing is necessary for the continuous slip-up of slip form. In this study, the rebound hardness, time of ultrasonic waves propagation, heat of hydration, and external temperature are measured by developing heating panels and test devices for the continuous slip-up. Based on this, heating slip form is manufactured; this was applied to "Kimpo sites" and "Sinwol sites". The compared slip-up speed samples were 1.9 m/day or 0.200 m/hr on average at Gimpo sites (08:00~17:30) and 2.0 m/day or 0.210 m/hr at Sinwol sites.

Decomposition of EVA(Ethylene vinyl acetate) used as an adhesion of photovoltaic(PV) module by ultrasonic irradiation in bath-type cleaner (Bath-type 초음파(超音波) 세척기(洗滌器)를 이용(利用)한 태양전지모듈 접착제(接着劑) EVA(Ethylene Vinyl Acetate) 분해특성(分解特性))

  • Kim, Young-Jin;Lee, Jae-Ryeong
    • Resources Recycling
    • /
    • v.20 no.6
    • /
    • pp.50-55
    • /
    • 2011
  • Using ultrasonic irradiation, the separation and recovery of PV cell, made of silicon wafer, from PV module was carried out through selective decomposition of EVA used as an interlaminated binder. The ultrasonic cleaner of bath-type (Output: 130 W, Frequency: 40 kHz) was used as an ultrasonic apparatus in this research. With the fixed distance of 2 cm, from ultrasonic generator to PV cell, the experiment of EVA decomposition was performed in various organic solvents such as Toluene, Trichloroethylene, O-dichlorobenzene, Benzene. And also their concentrations and temperature was changed to survey the optimum conditions. However EVA can be decomposed perfectly at $55^{\circ}C$ within 160 min in 5 M of all kinds of solvent, PV cell may be recovered with being damaged or broken severely. This damage may be resulted from the swelling of EVA in the process of decomposition. Whereas, at the condition of 5 M at $65^{\circ}C$, PV cell can be recovered with the state of minor damage or crack. This implies that the decomposition rate of EVA increases with an increase of temperature, thereby EVA can be decomposed before the swelling of EVA layer. Conclusively, it is possible for PV cell to be recovered within 40 min, at $65^{\circ}C$ in 5 M, with less damage.

A Study on Cooling of Piezoelectric Element of Multifunction Equipment for Vacuum Exhaust and Ultrasonic Joining (진공 배기 및 초음파 접합 복합기 진동자 냉각에 관한 연구)

  • Park, Sang-Jun;Lee, Young-Lim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1511-1517
    • /
    • 2012
  • Vacuum chamber or vacuum tube for the exhaust process of vacuum glazing is presently used, where excessive time and expenses are required to make the whole vacuum chamber or tube vacuum. To solve this problem, multifunction equipment for vacuum exhaust and ultrasonic joining at atmospheric pressure has been developed, in which a piezoelectric vibrator experiences excessive temperature rise resulting in optimizing the cooling of the equipment. Therefore, in this study, cooling effects of natural convection and forced convection methods were identified by numerical analysis and experiments, and cooling performance of the multifunction equipment was optimized.

A Study on Development of Composite Ultrasonic Transducer Assembly with Drug Transfer Function (약물 이송기능을 갖는 복합구조 초음파 변환기 어셈블리 개발에 관한 연구)

  • Noh, Si-Cheol;Kim, Ju-Young;Yoo, Byeong-Cheol;Jung, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.353-359
    • /
    • 2017
  • The sonophoresis, a representative low-intensity ultrasonic therapy, is a technique for delivering the drugs into the epidermis, dermis and skin appendages by using physical vibration and heat effects of the ultrasonic waves. Sonophoresis could increases the delivering and absorption efficiency of the drugs usually consisting of hydrophilic molecules and macromolecules. In addition, it has the advantage of being effective in delivering drugs with relatively large molecular sizes such as insulin or lipid. In this study, we proposed a multi-structure ultrasonic transducer assembly with a large-size single piezoelectric element and a drug delivery function at the treatment site for efficient sonophoresis treatment. Futhermore, a transducer assembly structure capable of raising and maintaining the temperature of the treatment site was proposed and evaluated for effectiveness. The transducer assembly proposed in this study is expected to improve the efficiency of sonophoresis by providing a constant amount of drug, and assisting drug delivery through heating the treatment site.

Treeing Phenomena to High Temperature for Epoxy Based Nanocomposites (에폭시기반 나노콤포지트의 고온부에서 트리잉현상)

  • Park, Jae-Jun;Cho, Dae-Ryung;Um, Ji-Yong;Yun, Yo-Wook;Baek, Kwan-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.155-156
    • /
    • 2008
  • 물리적 분산기법으로 초음파와 균질기를 동시에 적용한 분산기법을 이용하여 에폭시 기반 층상나노실리케이트를 충진한 에폭시-나노콤포지트 제조하였다. 유리천이온도 특성으로 무충진 에폭시수지와 층상실리케이트가 충진된 나노콤포지트의 비교에서 $9.2^{\circ}C$가 상승되는 결과를 얻었다. 고온부인 $130^{\circ}C$ 환경온도에서 장시간 트리잉 절연파괴측정에서 무충진에폭시 수지에 비하여 나노콤포지트가 절연파괴시간이 13.39배 늦은 시간에 파괴되었고, 트리진전속도의 경우 나노콤포지트가 13.9배 늦은 지연속도를 나타내었다.

  • PDF

Thermal Dispersion Method for a Medical Ultrasonic Phased Array Transducer (의료용 초음파 위상배열 트랜스듀서의 열 분산 방안)

  • Lee, Wonseok;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.3
    • /
    • pp.210-218
    • /
    • 2015
  • When the driving voltage of an ultrasound transducer is increased to improve the quality of ultrasound images, heat is generated inside the transducer that can cause patient's skin burn and degradation of transducer performance. Hence, in this paper, a method to disperse the heat of the transducer has been studied. The phased array transducer having 3 MHz center frequency and 32 channels was selected for analyses of the thermal dispersion. First, mechanism of the heat generation was investigated in relation to the transducer operation through theoretical analysis, and material damping and sound pressure amplitude were confirmed to be influential on the heat generation. Further, we investigated the effects of the properties of the materials constituting the transducer on the thermal dispersion through finite element analysis. Based on the analysis results, we determined the thermal properties of the constituent materials that could facilitate the thermal dispersion inside the transducer. The determined thermal properties were applied to the finite element model, and the results showed that the maximum temperature at an acoustic lens contacting with a patient was decreased to 51 % of its initial value.