• Title/Summary/Keyword: 초음파탐촉자

Search Result 101, Processing Time 0.026 seconds

A Study on the Quality Control of Transvaginal Ultrasound Transducer using ATS-539 Ultrasound Phantom (ATS-539 초음파 팬텀을 이용한 경질 초음파 검사용 탐촉자의 정도관리에 대한 연구)

  • Park, Ji Hye;Heo, Yeong Cheol;Kim, Yon min;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.463-472
    • /
    • 2021
  • Demand for examinations using transvaginal transducer with high frequencies is increasing to observe pelvic organs in gynecological ultrasound tests. However, the quality control of the replacement probe in clinical trials is not properly implemented and the evaluation criteria have not been established. Therefore, 58 transvaginal transducers and 20 convex transducers were applied to the ATS-539 ultrasound phantom for 20 ultrasound devices currently in clinical use to obtain their respective images and measure them quantitatively and qualitatively. For quantitative measurements, vertical measurement, horizontal measurement, and focal zone and qualitative measurements, dead zone, axial·lateral resolution, sensitivity, functional resolution, gray scale·dynamic range were performed. Quantitative statistical analysis showed significant differences between the two transducers in the lateral measurement and local area (p<0.05). qualitative comparative analysis showed differences in sensitivity and functional resolution. This occurs due to the difference in frequency between transducers and the transducer's injection geometry. Based on the above experiments, the tolerance for horizontal measurement is raised to 10% (±8 mm), the tolerance for sensitivity is observed up to 6 cm deep, which is 12 cm deep,which is the level of the third quartile (75%). The permissible range of functional resolution is up to 6 (12 cm), 6 (12 cm), 11 (11 cm), 9 (9 cm), 6 (6 cm) target, which is the level of the third quartile (75%). It is considered reasonable to adjust the depth of targets in gray scale·dynamic range to measure at a depth of 2 cm, which is 50% of the depth of 4 cm. As above, the criteria for evaluating the quality of transvaginal transducer for use in the past have been proposed and it is expected that this study will be used as a basic data for the production of phantom exclusively for transvaginal transducer in the future.

Effects of Settings in Dynamic Ranges and Frequency Modes on Ultrasonic Images (초음파 영상에서 동적영역과 주파수 방식의 설정에 따른 효과)

  • Yang, Jeong-Hwa;Kang, Gwan-Suk;Lee, Kyung-Sung;Paeng, Dong-Guk;Choi, Min-Joo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.277-283
    • /
    • 2009
  • It is important to get clinical ultrasonic images of good quality for accurate diagnosis. In this study, it observed the change of ultrasonic images against setting frequency, dynamic range(DR) and type of probes on ultrasonic scanner. In the experiment it evaluated image of LCS (Low Contrast Sensitivity) targets(-15, -6, -3, +3, +6, +15 dB) of a standard ultrasonic test phantoms(539,551, ATS, USA) similar to solid and cystic lesions. Its imaged from convex (C3-7IM) and linear probe (L5-12IM) on SA-9900 (Medison Ltd, Korea) scanner. The images obtained altering the setting parameters which are frequency(gen, pen, res, harmonic) mode and DR($40{\sim}100\;dB$). The quality of images evaluated compare with the nominal LCS value of target and measured LCS value. The results show that there was no significant changing of quality images altering DR 40, 60, 80, 100 dB against frequency in Convex probe but the image being the highest in LCS target at DR 60 dB, harmonic of frequency mode in the -15 dB target close to cystic lesion. In Linear probe, DR 40 dB, harmonic mode at -15 dB LCS target close to nominal value. It discussed necessity of evaluation about ROC(Receiver Operating Characteristic) from the psychological viewpoint and limit of evaluation from quantified images.

  • PDF

Depth Sizing of Notch Fatigue Crack Using Diffracted Ultrasonic Wave (회절초음파를 이용한 노치 피로균열의 균열깊이 평가)

  • Jin, Mei-Ling;Lee, Tae-Hun;Park, Byung-Jun;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.405-414
    • /
    • 2009
  • This paper proposed a methodology based on ultrasonic diffraction technique to inspect the depth of a crack initiated from a notch of CT specimen by fatigue test, and its usefulness was verified by experiments. Especially, in order to identify accurately the diffractive waves from the crack tip in the situation where there are extra diffractive elements such as a notch, we have tried imaging by transducer scan and analyzed the propagation path of diffracted wave. Two specimens with and without a crack were experimented. Higher frequency and larger refractive angle of transducer showed a tendency to decrease the error in the measurements, and the measured crack depth showed an error less than 0.38 mm in case of 4 MHz $60^{\circ}-60^{\circ}$. The proposed methodology is applicable to weak diffractive sources, and so that it would be useful to inspect micro cracks and for their depth sizing.

Modeling of Radiation Beams from Ultrasonic Transducers in a Single Medium (단일 매체에서의 평면 초음파 탐촉자의 방사 음장 모델링 기법)

  • Song, Sung-Jin;Kim, Hak-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.2
    • /
    • pp.91-101
    • /
    • 2000
  • Modeling of radiation beam from ultrasonic transducers has been investigated extensively, since it is one of the most important, fundamental issues that have great influence on the accuracy of an ultrasonic measurement model. Here, three popular radiation models, namely the Rayleigh-Sommerfeld integral model, the boundary diffraction wave model and the edge element model, are discussed briefly, and the radiation beam fields from ultrasonic transducers with planar, circular and rectangular cross-sections are calculated using these three models. Then, the accuracy and the time-efficiency of these methods are compared based on the calculation results.

  • PDF

A Study on method of Using Ultrasonic Transducers With shear wave Polarization Direction (전단파 분극현상을 갖는 초음파 탐촉자 민감도 기법에 관한 연구)

  • 나승우;임광희;송상기;정동화;양인영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.744-747
    • /
    • 2001
  • This paper shows shear wave behavior of CFRP composite laminates as a polar grid form to evaluate vibration pattern of ultrasonic transducers, which gives measured modelling fundamental contents of nondestructive evaluation. Polarized direction can be obtained by using a c-scanner and sensitivity of transducers is founded when using through-transmission method of two transducers. And modelling of vector decomposition is presented based on ply-to-ply method to apply practicable nondestructive evaluation of CFRP laminate lay up. This modelling decomposes the transmission of linearly polarized wave into orthogonal components through each ply of a laminate. It is found that a high provable shows between the model and experimental developed in characterizing layup of CFRP composite laminates.

  • PDF

Study on the Development of Multi-Path Ultrasonic Gas Flowmeter (전달 시간차 방식 다회선 초음파 가스 유량계 개발)

  • 황원호;박상국;이치환;장경영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1046-1050
    • /
    • 2003
  • In this paper, we describe study on the development or multi-path ultrasonic gas flowmeter using a transit time method. This system includes 5 pairs of ultrasonic transducers. ultrasonic signal processing unit using switch matrix method, computation algorithm of gas flow rate, spool piece type multi-path pipe unit. We have developed enhanced type of main ultrasonic signal processing unit using switch matrix method fer multi-path ultrasonic gas flowmeter. Also, we have developed the new transmitting & receiving method of ultrasonic waves and the new signal processing algorithm for the computation of ultrasonic transit time from received ultrasonic waves. In this study, we have designed more compact signal processing unit compared with the conventional hardware system of multi-path ultrasonic gas flowmeter. We have confirmed its reliability for multi-path ultrasonic gas flowmeter through the laboratory test using calibration system. In the future. we will perform the field test for the developed system in the POSCO gas line.

  • PDF

Investigation into the Actual State of Sanitary Management and Recognition Degree and Infection Level of Ultrasonographic Probes (초음파 탐촉자(Probes)의 위생관리 실태와 감염 인식도 조사 및 세균 오염도 측정)

  • Lee, Chang-Bok;Lee, Yang-Sub;Lee, Won-Hong;Cho, Cheong-Chan;Yoon, Hyang-Yi;Lee, Yong-Moon;Kim, Young-Keun;Lee, Kyung-Sup
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.51-58
    • /
    • 2004
  • The gel, which is stained on probe after ultrasonography, is a good circumstances for proliferation of microbe. This study is to investigate into the actual state of sanitary management, recognition degree and infection level of ultrasonographic probes. We had performed a question with telephone to 42 hospitals in Seoul area from December in 2003. We also cultured to obtained a sample from three ultrasonographic units to investigate infection level of the probes. Sanitary management of the probes was performed in 21 hospitals with alcohol cotton. Sanitary management was performed daily in 14 hospitals. Most hospitals used cotton towel for clearing of gel stained on probes. Preventive management against infection was performed in 32 hospitals with vinyl cover, surgical glove, or alcohol sterilization etc. In the recognition degree on infection, the response that using method of ultrasonographic probes is insanitary were in 78.6%(33 hospitals), and 54.8%(23 hospitals) responded that bacteria can be infected through the probes. In the results of germiculture, bacteria and fungi were detected too number of to count, but escherichia coli was not detected. In conclusion, The gel stained on probe after ultrasonography must be cleared completely, and it is necessary that change of recognition on sanitary management.

  • PDF

Ultrasonic C-scan Technique for Nondestructive Evaluation of Spot Weld Quality (Spot용접 접합면의 초음파 비파괴평가 기법 제 1보 C-scan 기법을 중심으로)

  • Park, Ik-Gun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.112-121
    • /
    • 1994
  • This paper discusses the feasibility of ultrasonic C-scan technique for nondestructive evaluation of spot weld quality. Ultrasonic evaluation for spot weld quality was performed by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of the corona bond from nugget, preliminary infinitesimal gap experiment by newton ring is tried in order to set up the optimum ultrasonic test condition. Ultrasonic image data obtained were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be measured with the accuracy of 1.0mm, and voids included in nugget can be detected to $10{\mu}m$ extent with simplicity and accuracy. Finally, it was found that it is necessary to make a profound study of definite discrimination of corona bond from nugget and the approach of quantitative evaluation of nugget diameter by utilizing the various image processing techniques.

  • PDF

Characterization of Component Materials of the Ultrasonic Transducer (초음파 탐촉자 구성 재료의 특성 연구)

  • Kim, B.G.;Park, Y.K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.69-76
    • /
    • 1989
  • Piezoelectric elements, backing and shoe material are the important components of the ultrasonic transducer. In this study, characteristic constants in the domestic and the foreign PZT ceramic elements are investigated, The acoustic properties of the domestic and the foreign backing and shoes are characterized. The effects of components characteristics, the kinds of the piezoelectric elements and the thickness of the wear plates are investigated for the manufactured normal beam ultrasonic transducers.

  • PDF

Development and Application of an Ultrasonic Gas Flowmeter (초음파 가스 유량계 개발과 활용)

  • Hwang, Won-Ho;Park, Sang-Gug;Jeong, Hee-Don;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.246-253
    • /
    • 2002
  • This paper describes the development and the field application of the ultrasonic gas flowmeter for accurate measurement of the volumetric flow rate of gases in a harsh environmental conditions in iron & steel making company. This ultrasonic flowmeter is especially suited for measuring LDG, COG, BFG gases produced in iron & steel making process. This is a transit time type ultrasonic flowmeter. We have developed the transmitting & receiving algorithm of ultrasonic wave and the ultrasonic signal processing algorithm to develope a transit time type ultrasonic flowmeter. We have evaluated the performance of ultrasonic flowmeter by the calibration system with Venturi type standard flowmeter. We has confirmed its reliability by extensive field tests for a year in POSCO, iron & steel making company. Now we have developed the commercial model of ultrasonic flowmeter and applied to the POSCO gas line.