• Title/Summary/Keyword: 초음파방사힘

Search Result 6, Processing Time 0.015 seconds

Haptic recognition of the palm using ultrasound radiation force and its application (초음파 방사힘을 이용한 손바닥의 촉각 인식과 응용)

  • Kim, Sun Ae;Kim, Tae Yang;Lee, Yeol Eum;Lee, Soo Yeon;Jeong, Mok Kun;Kwon, Sung Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.467-475
    • /
    • 2019
  • A high-intensity ultrasound wave generates acoustic streaming and acoustic radiation forces when propagating through a medium. An acoustic radiation force generated in a three-dimensional space can produce a solid tactile sensation, delivering spatial information directly to the human skin. We placed 154 ultrasound transmit elements with a frequency of 40 kHz on a concave circular dish, and generated an acoustic radiation force at the focal point by transmitting the ultrasound wave. To feel the tactile sensation better, the transmit elements were excited by sine waves whose amplitude was modulated by a 60 Hz square wave. As an application of ultrasonic tactile sensing, a region where tactile sense is formed in the air is used as an indicator for the position of the hand. We confirmed the utility of ultrasonic tactile feedback by implementing a system that provides the number of fingers to a machine by receiving the shape of the hand at the focal point where the tactile sense is detected.

Calculation of the ultrasonic radiation force acting on a rigid circular cone and the study on the metrology for the acoustic power measurement (강체원뿔표적에 대한 초음파 방사힘 계산과 음향파워측정모델에 관한 연구)

  • Kyungmin Baik;Jooho Lee;Elmina B. C. Fritzie;Yong Tae Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.335-343
    • /
    • 2024
  • This paper came up with the theoretical modelling of the metrology for the acoustic power using ultrasonic radiation force and showed some theoretical results. In order to do this, a scattering model for a rigid circular cone based upon the Kirchhoff approximation was made, which was followed by the calculation of acoustic power, and then, was converted to the radiation force. From these works, it provided the accuracy and limitation of the conventional method using a circular cone, and the expanded metrology modelling that can be applied to a circular cone with arbitrary apex angle. Using these, this study provided the dependence of the metrology for the acoustic power using ultrasonic radiation force on the frequency and the size of the target. As a result, the correction was yielded in the value of the acoustic power calculated by the suggested International Electrotechnical Commission (IEC) method, which needs to be added when the frequency and the size of the target was considered.

Radiation Conductance Determination of Ultrasonic Transducer using the Laser Interferometry (레이저 간섭계를 이용한 초음파 변환기의 방사 컨덕턴스 결정)

  • 조문재
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.174-178
    • /
    • 1993
  • 초음파 변환기의 방사 컨덕턴스를 결정하기 위해서는 변환기로부터 방사된 음향파워와 입력전압의 정밀측정을 요구하게 된다. 음\ulcorner파워는 초음파를 거의 완전 반사시킬 수 있는 표적을 사용하여 변환기로부터 방사된 음압에 의해 표적에 가해진 힘을 수동맞저울과 레이저 간섭계로 측정하여 구하였으며, 입력전압을 열 변환기와 전압계를 한 시스템으로 하여 정밀 측정하였다. 방사 컨덕턴스의 최대 측정오차는 $\pm$4% 이내로 평가되었다.

  • PDF

Acoustic Power Measurement System of Array Probes for Ultrasonic Diagnostic Equipment Using Radiation Force Balance Methods (방사힘 측정법을 이용한 초음파 진단장치용 배열 탐침자의 음향파워 측정시스템)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.355-364
    • /
    • 2010
  • Considering biological safety, it is very important to measure acoustic power from ultrasonic array probe for diagnostic ultrasound imaging applications. In this paper, to measure acoustic power from each element on array probe for ultrasonic diagnostic equipment, we reconstruct and automate the acoustic power measurement system. The acoustic power from linear, phased and curved array were measured and analyzed. As a result of measurement, the effects caused by directivity of sound beam from curved array were founded. To remove these effects, we developed and applied the correction model. The proposed system is useful to evaluate characteristics of the acoustical output power of array probe.

Investigation of standing wave acoustic levitation with Bernoulli principle and bolt-clamped Langevin type ultrasonic transducer (베르누이 원리와 bolt-clamped Langevin type 초음파 진동자를 이용한 정상파 음파 공중부양의 탐구)

  • Park, Mincheol;Park, Doojae;Kim, Young H.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.6
    • /
    • pp.422-427
    • /
    • 2018
  • The purpose of this study is to investigate the effect of acoustic radiation force on the standing wave acoustic levitation phenomenon, which is the levitation of small objects near the pressure node of the standing wave, using the Bernoulli principle. The source and scheme of the acoustic radiation force, which is the cause of the levitation, are conceptually explained through comparison with the graph of the acoustic radiation force versus the distance from the transducer. A series of experiments supporting this explanation was performed with a BLT(Bolt-clamped Langevin Type) ultrasonic transducer to confirm that the objects are floating near the pressure nodes and that it satisfies the condition for the standing wave formation when the object is levitating. Furthermore, the vertical alignment of floating objects, which is a characteristic of standing wave acoustic levitation phenomenon, could be explained.

Construction of Ultrasonic Power Measurement System and Its Performance Evaluation (초음파 파워 측정 시스템 구성 및 성능평가)

  • Jho Moon Jae;Kim Yong Tae;Yun Yong Hyeon;Jung Suug Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.8
    • /
    • pp.431-440
    • /
    • 2005
  • The precise measurement of ultrasonic power is important to the qualify assurance and the safety of medical ultrasonic equipments In the Present work, a brier theory was introduced to determine the ultrasonic Power from the time valving balance-indication due to the radiation force acting on an absorbing target and/or other causes such as buoyancy during the repetition of on/off behavior of ultrasonic irradiation. The developed automated system measuring the ultrasonic power was described in detail with the precise mechanical alignment tool , the electric signal generation network, the control and measurement network and the appropriate procedure. The ultrasonic power measured by the developed system was compared to the reference data calibrated by the other national metrology institute at 1 MHz, 5 MHz, 10 MHz, and 15 MHz over the range 10 mW to 10 W. Their relative differences are within $5\%$.