• Title/Summary/Keyword: 초음파기기

Search Result 211, Processing Time 0.024 seconds

Efficiency of Angular Spectrum Method for Analysis of Acoustic Fields in Water (수중 초음파 음장해석에 있어서 각스펙트럼법의 유효성 검토)

  • Kim, Jung-Soon;Kim, Moo-Joon;Ha, Kang-Lyeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.105-111
    • /
    • 1997
  • Before application of the angular spectrum method to calculate acoustic fields in stratified water, its efficiencies and errors were analyzed by using a virtual boundary in homogeneous water. As the results, it was confirmed that the angular spectrum method was able to calculate an acoustic field rapidly though some errors due to the limitation of reference field size and number of data in FFT ware included. A modified method combined the angular spectrum with Lommel's approximation, which was newly proposed in this paper, was useful to reduce the errors.

  • PDF

Indoor Localization Method using Single Inertial and Ultrasonic Sensors (단일 관성 센서와 초음파를 이용한 실내 위치추정 방법)

  • Ryu, Seoung-Bum;Song, Chang-Woo;Chung, Kyung-Yong;Rim, Kee-Wook;Lee, Jung-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.4
    • /
    • pp.115-122
    • /
    • 2010
  • Most of intelligent services provided today work based on the users' location. Numerous devices for indoor localization services have their own characteristic functions and operating systems, we need the interoperability and diversity of middleware to connect and control these devices. The indoor localization method using existing inertial sensors are relatively less efficient because of additional cost according to the size of space. Accordingly, the indoor user localization method proposed in this study supports integrated services using OSGi framework, an open source project, and solves problems in inertial sensor based on accurate distance to a specific object measured using ultrasonic sensor. Furthermore, it reduces errors resulting from difference in response rate by adding the reliability item.

A Study on the Removal Performance of PM10 by the Air-washer and the Ultrasonic Humidifier (자연 기화식 가습기와 초음파 가습기의 PM10 제거성능)

  • Lee, Joo-Ho;Kim, Sun-Sook;Park, Sung-Kwan;Park, Jun-Hyung;Lee, Yun-Gye
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.720-724
    • /
    • 2008
  • The purpose of this study is to evaluate the PM10 removal efficiencies of an Air-washer and an Ultrasonic humidifier by mock-up experiments. The concentrations of PM10 were measured at 5 minute intervals using $\beta$-Ray method. The average PM10 removal efficiency of the Air-washer was 79.8%, while the PM10 concentrations increased with the operation of Ultrasonic humidifier. In the case of operating the Air-washer, the R.H(Relative Humidity) level of the test room was maintained at around 45%, regardless of initial R.H condition. The R.H of the test room with Ultrasonic humidifier was influenced by the initial R.H condition.

  • PDF

The Noise Level Assessment of Dental Equipment (치과 의료장비의 소음 수준 평가)

  • Lee, Jeong-Suk;Han, Ye-Seul;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.603-611
    • /
    • 2015
  • This research is aimed at cutting off hearing loss and other harmful factors due to noise and providing basic material for noise reduction plan. As the research method, this research assessed noise by measuring acoustic pressure level and frequency in various situation of non-treatment and treatment. As the measurement result, average noise degree of high speed handpiece of non-treatment, ultrasonic waves scaler, and low speed handpiece showed 58~66 dB(A). Average noise degree of scaling of treatment, tooth elimination, and denture adjust showed 73~81 dB(A). The result is inferior to recognized standards of noise induced hearing loss. But the result of assessing this with (noise rating) NR curve was NR-73~78, which exceeded general workplace noise standard. This level can cause hearing loss when exposed to a long time. Therefore, treatment office noise during dental treatment can cause psychological and physical damage in dental clinic employees, and it is urgently required to establish systematic and active noise reduction plan.

Development of Ultrasonic Testing System for In-Service Inspection of the Shrunk-on Type LP Turbine Roter (Shrunk-on Type 저압 터빈 로터의 가동중검사를 위한 초음파검사 시스템 개발)

  • Park, Joon-Soo;Seong, Un-Hak;Ryu, Sung-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.130-136
    • /
    • 2009
  • Turbine, which is one of major components in nuclear power plants, requires reliable nondestructive inspections. But, accessibility of transducers is limited and interpretation of acquired signals is not easy at all due to the complication. So, in this study, we have fabricated mock-up specimens of real size and shape. we applied pulse-echo method and time-of-flight diffraction(TOFD) method for precise inspection of turbine key and wheel bore. And phased array ultrasonic testing method was adopted for wheel dovetail of turbines by using mock-up. Furthermore, an automatic scanner system was developed for in-service inspection of the developed methods.

Optimal Many-core Processor Architecture for Different Ultrasonic Image Resolutions (초음파 영상선호의 크기 변화에 따른 최적의 매니코어 프로세서 구조)

  • Kang, Seong-Mo;Kim, Jong-Myon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.50-55
    • /
    • 2012
  • This paper proposes an optima] many-core processor architecture that meets the requirements of low power and high performance for different ultrasonic image resolutions in hand-held ultrasonic devices. To identify the optimal many-core architecture, seven different PE configurations are simulated for processing ultrasonic images in terms of execution performance and energy consumption. Experimental results indicate that the highest energy efficiencies are achieved at PEs=1,024, 64, and 256 for ultrasonic images at $256{\times}256$, $320{\times}240$, and $800{\times}480$ resolutions, respectively. In addition, the maximum area efficiencies are obtained at PEs=256 (for $256{\times}256$ and $800{\times}480$ image resolutions) and 64 (for $320{\times}240$ image resolution).

Design and Implementation of Mobile ]Respiration Detection Diagnostic System using Ultrasound Sensing Method fficient Multicasting Environment (초음파 센싱 방식을 이용한 이동형 호흡량 측정 진단기의 설계 및 구현)

  • 김동학;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.509-515
    • /
    • 2004
  • Pulmonary function tests are widely used to diagnose and determine patients' therapy in clinic. And it was also applied in the research of the physiology and dynamics for lung disease. Among the pulmonary function tests, spirometry is the most easy and economic test. Spirometers are medical instruments that measure the instantaneous rate of volume flow of respired Bas. The mechanical spirometer was mostly used in the past. Up to the present, the most popular method of spirometer is the differential pressure technique with which change in the volume of flow are transferred to change in pressure. This kind of instrument suffers from several limitations, pressure drop, difficulty in maintenance and short period of calibration. Therefore, this study has begun to implement ultrasound spirometer, which is free of pressure loss and has wide range, focusing on the flow measurement technique and diagnostic algorithm.

Prolotherapy in Orthopedic Field (정형외과 영역에서의 증식치료)

  • Shon, Min Soo;Yoo, Jae Chul
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.101-110
    • /
    • 2011
  • To describe the background, mechanism, clinical results and complications of prolotheapy based on the literature review. Prolotherapy is a minimally invasive injection-based treatment of chronic musculoskeletal pain, including ligament and joint laxity. The mechanism of this injection-based technique is to initiate a local inflammatory response with resultant tissue healing. The used proliferants are classified by bio-mechanism to act in three different ways as osmotic, irritants, and chemotatics. The most commonly used proliferant is hyperosmolar (10~25%) dextrose to act by osmotic rupture of cells. High resolution ultrasound imaging of musculoskeletal structure provide a more accurate diagnosis. Also ultrasound-guided intervention provides a more high efficacy and low rate of complications. The most common complication is local pain at the injected site, that is self-limited and good responsive to anti-inflammatory agents. Other complications are rare. It is reported that prolotherapy appears safe when performed by an experienced clinician. Prolotherapy has grown in popularity and has received significant recent attention. However there are limited evidence-based data supporting the indication and efficacy of prolotherapy in the treatment of chronic musculoskeletal pain or soft tissue injuries. Future studies are necessary to determine whether prolotherapy can play an independent and definitive role in a treatment for chronic musculoskeletal pain.

  • PDF

Analysis of Defect in CANDU Feeder Pipe using Phased Array Ultrasonic Inspection System (냉각재 공급자관 위상배열 검사 적용에 따른 결함 분석)

  • Lee, Sang-Hoon;Jin, Seuk-Hong;Kim, In-chul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.78-82
    • /
    • 2010
  • The feeder pipe of Main Primary Heat Transfer System in Wolsong Nuclear Power Plant was inspected by the Ultrasonic Phase Array technique in 2010. It is the first time to apply this method to the construction at Nuclear Power Plant in Korea. The time required for UT technique is less than RT method. The UT method doesn't need to evacuate personnel who works nearby inspecting area and doesn't need to wait developing of film. For these reasons, the UT method is the fastest method among the volumetric inspections. As a result of the examination, it became clear that main defect of the feeder pipe is the Lack of fusion in the welded area. Moreover, the rate of defect was reduced gradually as improvement of welder's skill. If welding machine has problem, the defect has tended to same pattern(occurred same position in the welding area) but these defects were founded without specific rules. For these reasons, the creation of defect is dependent on the skill of worker not on the automatic welding machine. This evaluation of defect signal and collecting data would be useful to further examination in ISI.

  • PDF

Accuracy of Ultrasonic Flaw Sizing using DAC Techniques for Pressure Vessels Welds of Nuclear Power Plant (초음파 DAC 기법을 이용한 압력용기 용접부의 지시 크기측정 정확도 평가)

  • Kim, Jae Dong;Lim, Hyung Taik;Doh, Eui Soon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.2
    • /
    • pp.20-24
    • /
    • 2015
  • During refueling Outage, In-service inspections(ISIs) for the Nuclear Power Plant components are mandatory requirement in accordance with ASME Code Sec. XI. Especially, in current ultrasonic testing is one of the most important NDT techniques that are used for volumetric examination methods for nuclear power plant components, and accurate sizing of flaw indication by UT is essential to assure the integrity of the components. However, ASME code specifies minimum requirement for vessel examination procedure, and so far many different flaw sizing approaches have been tried to apply. Through the Round Robin Test(RRT), the accuracy of ultrasonic flaw sizing using DAC techniques was measured with the mock-ups simulating typical pressure vessel welds. These mock-ups contain artificially introduced flaws of known size and location. This paper shows experimental comparison data on the accuracy of techniques using such as 6dB drop, 50%DAC, 20%DAC and 20%DAC with beam spread correction, and also shows that diverse DAC techniques can be effectively applied to the assessment of the flaw sizing for pressure vessel welds in the stage of welding and fabrication.