• Title/Summary/Keyword: 초음파건

Search Result 128, Processing Time 0.671 seconds

The Usefulness of Ultrasound Diagnosis of Acute Tendon Injury in Hand (급성 건 손상 환자에서 초음파의 유용성)

  • Choi, Chang Yong;Lee, Han Jeong;Choi, Hwan Jun;Kim, Mi Sun
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.729-734
    • /
    • 2008
  • Purpose: The evaluation and management of a completely transected tendon of the hand is relatively clear. In most cases, the integrity is assessed by physical examination(eg, broken normal cascade, motion loss) but occasionally, It happens in troubles. because of pain, limited patient cooperation(eg, child, unconscious patient), and other associated injuries(eg, fractures, foreign bodies). Methods: From september 2006 to August 2007, 28 patients were evaluated with real time ultrasonography preoperatively and postoperatively. Twenty eight patients with injured tendon were evaluated using an HDI 5000 Sono CT(Philips Medical Systems, Bothell, WA) machine with a high resolution, 7.5MHz hockey stick linear probe. Dynamic evaluation was performed in real time. Results: Surgery was performed after the ultrasonographic evaluation. Sonographic diagnosis and intraoperative findings were correlated. Ultrasonographic findings show tendon discontinuity, gaps, and fluid collection. Conclusion: We conclude that ultrasonography is helpful in evaluating and managing acute tendon injury. Especially, in cases of completely lacerated tendon, ultrasonography can identify the location of the proximal tendon stump and partial lacerated tendon, ultrasonographic diagnostic tool can decrease misdiagnosis.

Chemical-assisted Ultrasonic Machining of Glass by Using HF Substitute Solution (불산대체용액을 이용한 유리의 초음파 가공)

  • 전성건;남권선;김병희;김헌영;전병희
    • Transactions of Materials Processing
    • /
    • v.13 no.3
    • /
    • pp.262-267
    • /
    • 2004
  • Ultrasonic machining has been known as one of the conventional machining methods in the glass fabrication processes. In ultrasonic machining, typically, glass is removed by the impulse energy of the abrasive generated by the ultrasonic power. However, when the machining feature decrease under hundreds of micrometers, as conventional ultrasonic machining uses only the impulse energy of the abrasive, the speed of ultrasonic machining decreases significantly and the surface roughness becomes deteriorated. To overcome this size effect, the chemicals which can erode glasses, such as HF, XF, etc, are added to the slurry. The chemical-assisted ultrasonic machining method, so called, is another alternating effective way for micro machining of glasses. In previous work, we used the hydrofluoric acid (HF) as an additive chemical. But, as the HF solution is too poisonous to be used as a ultrasonic process additive, it is needed to be substituted by other safe chemicals. As results of the machinability comparison of several chemicals, the GST-500F was selected to replace the HF. The GST-500F (pH $4.0{\pm}1.0$) is non-volatile, odorless. During experimental works, it was shown that the machining rate increases 1.5 times faster than the conventional ultrasonic machining. The machining load also decreases. However, the enlargement of the hole diameter and significant tool wear are still the problems to be solved.

Experimental Result on Map Expansion of Underwater Robot Using Acoustic Range Sonar (수중 초음파 거리 센서를 이용한 수중 로봇의 2차원 지도 확장 실험)

  • Lee, Yeongjun;Choi, Jinwoo;Lee, Yoongeon;Choi, Hyun-Taek
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.2
    • /
    • pp.79-85
    • /
    • 2018
  • This study focuses on autonomous exploration based on map expansion for an underwater robot equipped with acoustic sonars. Map expansion is applicable to large-area mapping, but it may affect localization accuracy. Thus, as the key contribution of this paper, we propose a method for underwater autonomous exploration wherein the robot determines the trade-off between map expansion ratio and position accuracy, selects which of the two has higher priority, and then moves to a mission step. An occupancy grid map is synthesized by utilizing the measurements of an acoustic range sonar that determines the probability of occupancy. This information is then used to determine a path to the frontier, which becomes the new search point. During area searching and map building, the robot revisits artificial landmarks to improve its position accuracy as based on imaging sonar-based recognition and EKF-SLAM if the position accuracy is above the predetermined threshold. Additionally, real-time experiments were conducted by using an underwater robot, yShark, to validate the proposed method, and the analysis of the results is discussed herein.

Pulse-echo response of ultrasonic transducer fabricated with PZT-polymer 3-3 type composite (PZT-고분자 3-3형 복합압전체 소자로 제작된 초음파 트랜스듀서의 펄스에코 응답특성)

  • 박정학;최헌일;손무현;사공건
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1053-1059
    • /
    • 1996
  • The pulse-echo response of the piezoceramics PZT-polymer 3-3 type composite transducers with various PVA additions were investigated. The PZT powder was prepared by the molten salt synthesis method. The porous PZT specimens will be used as a filler to make 3-3 type comosite were prepared from a mixture of PZT and polyvinylalcohol(PVA) sphere by utilizing BURPS(Bumout Plastic Sphere) technique. It was shown that the transmitting and receiving sensitivity of 3-3 type piezoelectric composite transducers could be improved than that of solid PZT transducers. The reason is that 3-3 type piezoelectric composite have low dielectric constant, density and acoustic impedance. The distance between transducer and reflector was in good agreement with the distance calculated from the longitudinal velocity of the specimens and receiving time observed pulse-echo responses on the ultrasonic transducer analyzer.

  • PDF

Myofascial Pain, and the Spraying and Stretching Technique (근막동통과 분사신장요법)

  • Kim, Byung-Gook;Lim, Young-Gwan
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.3
    • /
    • pp.325-329
    • /
    • 2000
  • 근막동통은 발통점과 중추흥분효과가 나타나는 국소적 근육성 동통이다. 발통점은 근육의 일부나 건 부착점에 나타나는 부위로서 단단한 띠로서 느껴지고 촉진시 통증을 유발한다. 통증은 관련된 발통점의 위치에 따라 연관된 부위에 나타난다. 이러한 근막 발통점에 따른 증상은 약한 기능이상부터 일상생활이 어렵게 되는 정도의 심한 통증까지 다양하다. 이의 발생에는 국소적 근육이상, 심부 동통, 심리적 스트레스의 증가, 수면장애와 전신적인 요인들도 관여한다. 일반적으로 치료는 보존적인 처치로써, fluoro-methane 같은 vapocoolant spray를 사용하는 사용하여 분사신장하는 방법이 있으며, 국소적인 주사, 마사지, 초음파, 온열요법등이 있다. 여러 환자에서 근막동통을 가지는 환자에 분사신장요법을 시행한 결과 대부분 환자에서 증상의 개선을 보였다. 근막동통의 치료시 분사신장요법은 매우 보존적인 처치로 임상가의 적용과 접근이 쉬우며, 환자로 하여금 치료에 따른 불안감을 줄이면서 만족을 느낄 수 있는 치료로 사료된다. 그러나 만성 환자의 경우 분사신장요법의 치료결과에 대한 만족도가 높지 않았다. 분사신장 용법은 근막동통을 가진 환자 모두에서 효과적이지는 않으나 치료의 도입으로, 근막동통을 진단시에 일차적으로 사용할 수 있는 안정한 보존적인 용법으로 사료된다.

  • PDF

Engine Control And Drive Assist System (음주측정 시동 및 안전운전 보조시스템)

  • Park, Myeong-Chul;Hwang, Dong-Geon;Oh, Seong-Hyeok;Cho, In-Ho;Kim, Jae-Hwan;Lee, Do-Hui
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.01a
    • /
    • pp.297-298
    • /
    • 2022
  • 현재 도로 위 차량은 다양한 기능이 탑재되어 있고, 이는 운전자의 편의와 안전을 위해 발전해왔다. 하지만 음주운전과 안전운전 불이행에 의한 교통사고는 꾸준히 발생하고 있으며, 이 사고율은 단순히 제도적 규제와 운전자의 주의만으로는 감소시키기 어렵다고 판단된다. 본 논문은 제도적인 규범만이 아닌 기계적인 차원에서의 음주운전 사고 예방과 안전운전 불이행 사고의 방지를 하기 위해 '음주측정 시동 및 안전운전 보조시스템'을 제안한다. 이러한 문제를 해결하고자 알코올 측정 센서를 통해 시동을 걸기 전 음주측정을 해 음주운전의 가능성을 차단하고 초음파 센서를 이용하여 전, 후·측방 감지를 하고 주변의 장애물과 운전자의 부주의 시 즉각적인 피드백을 제공해 안전운전 불이행 사고를 방지할 수 있다.

  • PDF

Skin-Whitening and UV-Protective Effects of Angelica gigas Nakai Extracts on Ultra High Pressure Extraction Process (초고압 추출 공정에 의한 당귀 추출물의 미백 및 자외선 차단 효과)

  • Kim, Cheol-Hee;Kwon, Min-Chul;Han, Jae-Gun;Na, Chun-Su;Kwak, Hyeong-Geun;Choi, Geun-Pyo;Park, Uk-Yeon;Lee, Hyeon-Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.16 no.4
    • /
    • pp.255-260
    • /
    • 2008
  • This study was performed to investigate the enhancement of UV-protection activities and skin-whitening effects from Angelica gigas Nakai extracts on ultra high pressure extraction process. Extraction at $60^{\circ}C$ treated by ultra high pressure for 15 minute and associated with ultrasofication (HPE15) was showed more than double yield, compare conventional extraction, as 12.24% (w/w) from A. gigas. Extracts of HPE15 reduced expression of MMP-1 on UV-irradiated CCD-986sk cells as 122.2% and revealed high inhibitory potency on tyrosinase as 69.4% by adding samples. Extracts of HPE15 from A. gigas showed strong inhibition effect on melanin production test by Clone M-3 cells as 82.4% by adding extracts. From the preliminary observations, we considered that the extracts from A. gigas could be potent natural materials for skin-whitening agent, and could be used as a potential anti-aging agent for the photo-damaged skin.

Skin Whitening and Skin Immune Activities of the Peptides Isolated from Crassostrea gigas by Ultrasonification Processes (초음파 복합처리를 통한 참굴 펩타이드의 피부미백 및 피부면역 활성)

  • Han, Jae-Gun;Kim, Hyo-Sung;Kwon, Min-Chul;Kim, Jin-Chul;Hwang, Bo-Young;Lee, Hyeon-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.4
    • /
    • pp.394-399
    • /
    • 2008
  • In this study, peptides were isolated from Crassostrea gigas using an ultrasonification process at $40^{\circ}C$. The yield of the peptides was greater than 34%, and their cytotoxicity was found to be less than 22.8% against several cell lines that were treated with the extracts at a dose of 1.0 mg/mL. In addition, the tyrosinase inhibitory and melanin synthesis of the peptides isolated from Crassostrea gigas were also evaluated to determine if they could be used as a potential cosmetic agent. The peptides were found to significantly inhibit the melanin synthesis of the clone M-3 cell line by up to 62.7%. The inhibitory activities of the tyrosinase were observed 34.51% in ascorbic acid, 42.49% in extract with the ultrasonification at $40^{\circ}C$ and 35.37% in $40^{\circ}C$ extract at 1.0 mg/mL concentration, respectively. Finally, when samples were treated with the peptide extracts at a concentration of 0.6 mg/mL, PGE2 expression was significantly decreased. Taken together, these results indicate that Crassostrea gigas may be a source of cosmetic agents capable of improving physiological hyperpigmenting and immuno-modulating skin disorders.

MR Findings of Papillary Neoplasms of the Breast (유두 종양의 자기공명 영상소견)

  • Jo, Yeseul;Kim, Sung Hun;Kang, Bong Joo;Choi, Byung Gil
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.43-51
    • /
    • 2014
  • Purpose : To review MR imaging finding of papillary lesion identified as additional suspicious lesion on MR image in women with biopsy-proven breast cancer and to evaluate upgrading rates after subsequent surgical histopathological diagnosis. Materials and Methods: Among 1729 preoperative MR image of women with biopsy proven breast cancer, US-guided CNB-proven 22 papillary lesions from 21 patients, which showed additional suspicious contrast enhancement other than index cancer on MR image, were subjected to the study. Some of these lesions underwent surgery, thus the comparisons between the histopathologic results were able to be compared to the results of US-guided CNB. Also retrospective analysis was done for MR findings of these lesions by BI-RADS MRI lexicon. Results: On MR imaging, 8 mass lesions, 7 non-mass lesions, 7 focus lesions were detected. All of the focus lesion (100%, 7/7) was diagnosed as benign lesion and showed plateau and washout pattern in dynamic MR image. After excisional biopsy, one of 9 benign papilloma (11.1%), 3 of 3 papillary neoplasm with atypia component (100%), 3 of 5 papillary neoplasm (60%) were upgraded to malignancy such as ductal carcinoma in situ (DCIS), invasive ductal carcinoma (IDC), invasive lobular carcinoma (ILC). Conclusion: The MR images of papillary lesions diagnosed by US-guided CNB exhibit no significant differences between malignancy and benign lesion. Also 41.2% of the lesion (7/17) was upgraded after subsequent surgery. Thus all of the papillary lesions require excisional biopsy for definite diagnosis and the MR imaging, it's just not enough by itself.

The Changes of Sweating Area, Temperature and Blood Flow in the Upper and Lower Extremity after Hyperhidrosis Operations (다한증수술후 발한분포 및 상하지의 온도변화와 혈류량변화)

  • 김용환;장윤희;문석환;조건현;왕영필;김세화;곽문섭;김학희;장혜숙
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.456-460
    • /
    • 1999
  • Background: Thoracic sympathectomy for hyperhidrosis has been recognized as an effective treatment using thoracoscopic devices and operative techniques, but the satisfaction has decreased due to a compensatory hyperhidrosis. Therefore, the postoperative results and compensatory hyperhidrosis were analyzed. We also measured the temperature differences in the hand and foot during the preoperative and postoperative periods and measured the blood flow of upper and lower extremities. Material and Method: From December 1995 to July 1998, total of 47 patients with hyperhidrosis underwent sympathectomy via VATS at the Department of Thoracic and Cardiovascular Surgery, Kangnam St. Mary's Hospital. The patients were evaluated for preoperative and postoperative temperature changes on the finger and toe, and preoperative and postoperative blood flows were measured by the Doppler examination on the digital artery, radial artery and dorsalis pedis artery. Result: There were no operative deaths but some complications existed: 7 pneumothorax, 3 recurrence and 1 Honor syndrome. Ninety-five percent of the patients also had compensatory sweating especially in the trunk. There were 5 patients who regretted recurring the operation because of the compensatory sweating. Sweating decreased in 46% of the sole hyperhidrosis patients. The temperature difference between preoperation and postoperation was 1$^{\circ}C$ on the right hand side and 1.9$^{\circ}C$ on the left hand side(P<0.05). There was no significant temperature difference on the sole. Blood flow increased significantly in the palm, but no difference in the sole. Conclusion: In conclusion, thoracic sympathectomy for hyperhidrosis is a safe and effective treatment but satisfaction has been decreased by the compensatory sweating; therefore, it is important to thoroughly explain the compensatory sweating prior to surgery. Improvement of the plantar hyperhidrosis is not due to a physiological change, but to a psychological stability.

  • PDF