• Title/Summary/Keyword: 초기하중

Search Result 923, Processing Time 0.023 seconds

Tensile Properties of Metal Plate Connector in Domestic Softwood Lumber (국산 침엽수 철물접합부의 인장하중 특성)

  • Shim, Kug-Bo;Park, Jung-Hwan;Lee, June-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.96-103
    • /
    • 2003
  • This study was conducted to evaluate the tensile properties of metal plate connector for the domestic major softwoods, such as Korean red pine, Korean white pine, and Japanese larch. The maximum tensile load of Korean red pine was 3,612kgf in AA type, it was 1.2 and 1.7 times higher load than that of Japanese larch and Korean white pine. In EA type, it was 2,704kgf, and 1.1 and 1.5 times higher than the loads of Japanese larch and Korean white pine. The failure modes of metal plate connector were metal plate withdrawal, plate tensile failure, and wood shear block failure. The failure mode of Korean red pine connector was tensile failure of plate, that is reason of the high tensile load resistance for metal plate connections in Korean red pine. The mechanical properties of metal plate connector could be predicted by the Foschi model parameter. In the initial stage, the Korean red pine connector was stiffer than the other species. The design values for metal plate connector per tooth was 25, 22, and 15kgf for Korean red pine, Japanese larch, and Korean white pine in AA type and 19, 17, and 13kgf in EA type.

Study on Dynamic Instability of Plane Membrane Structures under Wind Action (풍하중을 받는 평면 막구조물의 동적불안정 판정에 관한 연구)

  • Han, Sung-Eul;Hou, Xiao-Wu
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.2
    • /
    • pp.145-152
    • /
    • 2009
  • In this paper, dynamic instability of plane membrane structures under wind action has been studied. The key to solving the governing equations of membrane structures under wind action is how to obtain the air pressure on membrane. Based on Bernoulli's theorem, fluid pressure has a certain relationship with velocity potential. Velocity potential could be solved according to thin aerofoil theory, where air around the membrane is regarded as a sheet of vortices. In this paper, we take advantage of the most commonly used three-node triangular membrane element and weighted residual-Galerkin method to obtain the determining equation for stability evaluation. Square and rectangular membrane structures are studied. The influence of initial prestressing force and wind direction towards critical wind velocity are also analyzed in this paper.

Field Behavior of Residual Stresses on Rock Socketed Drilled Shafts (암반에 근입된 현장타설말뚝에 작용하는 잔류응력의 현장거동)

  • Nam, Moon-S.
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.35-42
    • /
    • 2011
  • The residual stress on drilled shafts is often neglected. Neglect of the existence of locked-in loads in the shaft is the main reason for conclusions of instrumented tests which suggest that shaft resistance is smaller when the shaft is loaded in tension than when it is loaded in compression. A few researchers studied the residual stress and mentioned that the residual stress is influenced by either the physical expansion/contraction of concrete during the curing or site stratigraphy. In this study, field measurements of residual stress on test shafts were conducted and the factors influencing the residual stress were figured out.

Buckling and Postbuckling Control of a Composite Beam with Embedded SMA Wire Actuators (형상기억합금 선 작동기를 삽입한 복합적층 보의 좌굴 및 좌굴후 제어)

  • Choi, S.;Lee, J.J.;Seo, D.C.;Choi, S.W.
    • Composites Research
    • /
    • v.12 no.3
    • /
    • pp.45-54
    • /
    • 1999
  • In this paper, an experimental study on the buckling and postbuckling control of a laminated composite beam with eccentrically embedded SMA wire actuators is performed. For the purpose of enhancing the critical buckling load, buckling control is investigated through the use of reactive moment associated with the shape recovery force of SMA wire actuators. To improve the control authority for the buckling and postbuckling control of the SMA-composite beam, closed-loop control is used. The buckling and postbuckling control behaviours are presented and discussed qualitatively and quantitatively on loaddeflection plots considering the stacking sequence of the laminate, slenderness ratio of the beam and activation conditions of the SMA wire actuators. By maintaining the desired deflection shape with the proper reactive moment, buckling control can be extended to the postbuckling of the SMA-composite beam subjected to an external load.

  • PDF

A Study on the Nonlinear Instability Behavior of Hybrid Structures(II) -Characteristic of Dynamic In-Plane Torsional Buckling under the STEP Load- (Hybrid 구조물의 비선형 불안정 거동에 관한 연구(II) -STEP 하중에서의 동적 면내비틀림 좌굴 특성-)

  • Kim, Seung Deog;Kim, Hyung Seok;Kang, Moon Myung
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.5
    • /
    • pp.599-608
    • /
    • 2001
  • Many papers which deal with the dynamic instability of shell-like structures under the STEP load has been published but there have been few papers related to the dynamic instability of hybrid cable domes. And also there are a few researches which treat the essential phenomenon of the dynamic buckling using the phase for investigating occurrence of chaos. In this study the indirect buckling of hybrid cable domes considering geometric nonlinearity are investigated numerically and compared it with the static critical load The dynamic critical loads are determined by the numerical integration of the geometric nonlinear equation of motion and the mechanism of the indirect buckling is examined by using the phase curves.

  • PDF

Early loading on a maxillary posterior single implant with deepened threads: a case report (깊은 나사선을 갖는 임플란트를 이용한 상악 구치부 조기 하중: 증례보고)

  • Han, Chang-Hoon;Kim, Hyun-Seung;Park, Sang-Won;Yun, Kwi-Dug;Joo, Han-Sung;Lim, Hyun-Pil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.3
    • /
    • pp.253-258
    • /
    • 2014
  • This case report shows an early loading at the maxillary posterior area with the wide diameter implant which has a deepened threads after removal of failed implant. Implant Stability Quotient (ISQ) value has represented favorable result for one year. This clinical report describes the potential of early loading on a maxillary posterior single implant with deepened threads.

A Study on the Flexural Toughness Characteristics of Steel Fiber Reinforced Concrete (강섬유보강 콘크리트의 휨인성 특성에 관한 연구)

  • Park, Sung-Soo;Lee, Jeong-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.203-210
    • /
    • 2004
  • This study reviewed various current methods of evaluating the toughness of steel fiber reinforced concrete specimens and criticized the use of various multiples of first-crack deflection to define toughness indices. The load-CMOD curve to determine toughness, instead of load-deflection curve, was used. The notched steel fiber reinforced concrete specimens With different water/cement ratio(0 35, 0.40, 0.45, 0 50) and fiber volume content(0.0%, 0 5%, 1 0%, 1.5%) were tested under third point bending.

Dynamic Amplification Factor of Concrete-Filled Tubular Arch (CFTA) Girder due to the Effects of Moving Vehicles and PT Tendons (이동차량 및 PT 텐던 영향에 따른 CFTA 거더의 동적증폭계수 비교)

  • Roh, Hwa-Sung;Hong, Sang-Hyun;Lee, Sang-Yun;Park, Kyung-Hoon;Lee, Jong-Seh
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.743-746
    • /
    • 2011
  • 본 연구에서는 유한요소해석을 이용하여 차량속도 및 긴장재의 설계에 따른 CFTA 거더의 동적거동 및 동적증폭계수를 분석하였다. 긴장재의 해석변수로서는 긴장재의 양과 긴장력을 고려하였으며 차량하중은 도로교설계기준의 DB-24 하중을 선택하였다. 차량하중은 3축-2트랙에 작용하는 등가절점하중으로 변환하여 속도에 따라 시간함수로 모델링하였다. 긴장재의 양은 외측 �� 내측 덕트의 유무에 따라 변화시켰으며 긴장력은 설계긴장력의 0%에서 100%까지 25%씩 증가시켰다. 차량속도는 40km/hr에서 100km/hr까지 20km/hr씩 증가시켰으며, 해석결과 긴장재의 긴장력 변화는 거더의 동적거동에 영향을 주지 않았으며 초기처짐에만 영향을 주었다. 긴장재의 양에 따라서는 거더의 동적거동이 다르게 나타났으며 긴장재의 양이 적을 수록 동적처짐은 증가하였다. 이를 바탕으로 거더의 동적증폭계수(DAF)를 산출하였으며, 이 결과 긴장재가 없는 경우에도 도로교표준시방서에서 정한 기준 값보다 매우 작은 거동을 보였다.

  • PDF

Effects of Fine Contents on the Fracture Characteristics of Frozen Sand (세립분 함유량이 동결 사질토의 파괴특성에 미치는 영향)

  • Hwang, Bumsik;Cho, Wanjei
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.3
    • /
    • pp.25-36
    • /
    • 2020
  • In this research, three-point bending tests were performed using a rectangular frozen specimen with various fine contents and notch offset distance from the center of the specimen to investigate the fracture characteristic of the frozen sand. Based on the test results, mode I fracture toughness was calculated, and mixed-mode (mode I + II) fracture characteristics were investigated using the fracture energy which was calculated until the maximum point of the load-displacement curve. As the fine contents increase, the peak load and mode I fracture toughness increase until 10% fine contents. Furthermore, as the notch offset distance increases, the fracture energy required for crack start also increases due to the increase in mode II load at the crack tip.

An Estimation of Panel Deflection at Engine Room Upper Deck for the Ship Under Construction (건조중인 선박에서의 기관실 상갑판 판부재의 처짐 예측)

  • Juh-H. Ham;Ul-N. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.3
    • /
    • pp.119-128
    • /
    • 1994
  • Deflection estimation at engine room upper deck panel is performed for the actual ship structure. These deflection behaviours are basically investigated from not only the data based on the full series results of nonlinear analysis using Incremental Galerkin's Method but also actual deflection data measured from damaged ship under construction in dry dock. The effects of residual stress, initial deflection and static loading are also included. The computed estimation results of upper deck plate panel including theme effects are shown that upper deck platings of new ship expected less deflection magnitude than damaged ship.

  • PDF