• Title/Summary/Keyword: 체인 지름

Search Result 156, Processing Time 0.029 seconds

Scaling Up Study of Exopolysaccharide Production through Mycelial Submerged Cultivation of Ganoderma lucidum (영지의 액체배양에 의한 세포외 다당 생산의 Scale Up 연구)

  • Lee, Hak-Su;Lee, Shin-Young
    • KSBB Journal
    • /
    • v.24 no.3
    • /
    • pp.303-311
    • /
    • 2009
  • A scaling up study for the exopolysaccharide (EPS) production by submerged culture of Ganoderma lucidum was carried out in jar fermenter systems (2.6, 20 and 75 L) under bi-staged pH process. Profiles of dissolved oxygen (DO) and volumetric coefficient of oxygen transfer ($k_La$) as a function of operating variables (agitation speed and aeration rate) was investigated, and a correlation between $k_La$ and operating variables was analysed statistically. Under bi-staged pH process, no limitation of DO was observed at agitation speeds tested in the range of 200 and 600 rpm, and the highest EPS production was obtained at the level of DO of $40{\sim}80%$. From the regression analysis, the relation between $k_La$, gas velocity (Vs), stirrer speed (N) and impeller diameter (Di) could be expressed as : $$k_La=0.555{\times}Vs^{0.42}{\times}(N^3{\times}Di^2)^{0.33}\;(R^2=0.925,\;p<0.05)$$ It was found that under 2.6 L jar fermenter, the optimum agitation speed and aeration rate was 400 rpm and 1 vvm, respectively, obtaining the EPS production of 15.43 g/L. Under the submerged cultivation of G. lucidum in jar fermenters of $2.6{\sim}75\;L$, the similar EPS yields at each fermenter were achieved during scaling up based on $k_La$, and $k_La$ value for maximum EPS production was $85.4{\pm}26.70\;h^{-1}$.

Syntheses and Properties of ZnS:Mn/ZnS Core-Shell Quantum Dots Prepared via Thermal Decomposition Reactions of Organometallic Precursors at Various Reaction Temperatures (다양한 온도 조건에서의 ZnS:Mn/ZnS 코어-쉘 양자점의 합성 및 광 특성에 관한 연구)

  • Lee, Jae-Woog;Hwang, Cheong-Soo
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.677-682
    • /
    • 2009
  • ZnS:Mn/ZnS core-shell quantum dots (QDs), were synthesized via a thermal decomposition reaction of organometallic precursors in a hot solvent mixture. The synthetic conditions of the quantum dots were monitored at various reaction temperatures for the core formation, while the shell formation temperature was fixed at 135$^{\circ}C$. The obtained colloidal nanocrystals at corresponding temperatures were characterized by UV-Vis, solution photoluminescence (PL) spectroscopies, and further obtained powders were characterized by XRD, HR-TEM, and EDXS analyses. The synthetic temperature condition to obtain the best PL emission intensity for the core-shell QD was 135$^{\circ}C$, for both core and shell formation. At this temperature, solution PL spectrum showed a narrow emission peak at 583 nm with a relative PL quantum efficiency of 42.15%. In addition, the measured spherical particle sizes for the ZnS:Mn/ZnS nanocrystals via HR-TEM were in the range of 4.0 to 5.4 nm, while ellipsoidal particles were obtained at 150$^{\circ}C$.

Quantitative Analysis Methods for Adapting Image J programs on Mouse Calvarial defected Model (Image J 프로그램을 사용한 마우스 두개골 결손모델상의 정량적인 분석방법)

  • Jung, Hongmoon;Won, Doyeon;Jung, Jaeeun
    • Journal of Digital Convergence
    • /
    • v.11 no.9
    • /
    • pp.365-370
    • /
    • 2013
  • This mouse calvarial defected model is frequently used for new scaffold development in the bone regeneration. Most experiments are carried out in this way by measuring the bone regeneration of mouse calvaria defected area. As a next step, hematoxylin and eosin staining is analyzed by sacrificing mice On the other hand, the quantitative analysis for bone regeneration is carried out by micro computed tomography. However, there are several drawbacks with the micro computed tomography. That is, it takes a long time and it is quite expensive for bone regeneration quantitative analysis. This study was performed by simply measuring the quantity of bone regeneration in mouse clavaira defected area on two-dimensional digital x-ray images via Image J. Consequentially, this experimental method by using J program might help bio-technologist researcher regarding new bone regeneration by comparing the quantity of bone regeneration quickly and precisely as well.

Dielectric Waveguide Filters Design Embedded in PCB Substrates using Via Fence at Millimeter-Wave (밀리미터파 대역에서 Via Fence를 이용한 PCB 기판용 유전체 도파관 필터 설계)

  • 김봉수;이재욱;김광선;강민수;송명선
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.1
    • /
    • pp.73-80
    • /
    • 2004
  • In this paper, the implementation and embedding method of the existing air-filled waveguide-filters at millimeter-wave on general PCB substrate is introduced by systematically inserting the vias inside waveguide and mathematically manipulating the simple equations obtained ken the classical circular-post waveguide filter design. All the metal structures placed vertically such as side wall fur perfect ground plane and circular-post for signal control in the air-filled WR-22 waveguide are replaced with several types of via for constructing the bandpass-filter. Side wall and poles inside waveguide are realized by placing a series array of via and tuning the via diameter. The lengths of x, y, z axis are reduced in proportion to root square of employed substrate dielectric constant and especially the length of z axis can be more reduced due to the characteristics of the wave propagation. Because the mass production on PCB is possible without fabricating a large-scaled metal waveguide of WR-22 as input/output ports at millimeter-wave regime, the manufacturing cost is reduced considerably. Finally, when using multilayer process like LTCC for small-sized module, it is one of advantages to use only one layer f3r the filter fabrication. To evaluate the validity of this novel technique, order-3 Chebyshev BPF(Bandpass-Filter) centered at 40 GHz-band with a 2.5 % FBW (Fractional Bandwidth) were used. The employed substrate has relative dielectric constant of 2.2 and thickness of 10 mil of Rogers RT/Duroid 5880. Accroding to design and measurement results, a good performance of insertion loss of 2 ㏈ and return loss of -30 ㏈ is achieved at full input/output ports.

A Study on the Energy and Time Characteristics of $BaF_2$ Scintillation Detector ($BaF_2$ 검출기의 시간과 에너지 특성연구)

  • Ju, Gwan-Sik;Park, Il-Jin;Kim, Jong-Ho;Nam, Gi-Yong;Baek, Seung-Hwa
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.267-272
    • /
    • 1997
  • he scintillation detector having $BaF^2$ crystal with 3.6cm dia${\times}$2.0 cm thick was provided. The energy and timing characteristics were measured and compared with NaI(Tl) scintillation detectors, which widely used in unclear medicine. In order to measure the energy spectrum, the radioactive sources used were $^{22}Na,\;^{54}Mn,\;^{57}Co,\;^{137}Cs$ and the source to detector distance was 7cm. For the timing characteristic, NaI(Tl)(1" ${\times}$ 1")-$BaF^2$ and NaI(Tl)(3" ${\times}$ 3")-$BaF^2$ timing coincidence systems were prepared and the used source was $^{22}Na$ emitting 511keV annihilation photons. For the 511keV gamma-ray emitted from $^{22}Na$, It was revealed that the timing response of the $BaF^2$ detector was faster than NaI(Tl)(1" ${\times}$ 1") and NaI(Tl)(3" ${\times}$ 3") detector used in this experimental investigation. The energy characteristics of the $BaF^2$ detector had a good values for about 500keV energy range.

  • PDF

Estimation of Structural Safety for PolyEthylene (PE) Floating Platforms with API & AISC Standards (API & AISC 기준을 적용한 PolyEthylene (PE) 부유식 플랫폼의 구조 안전성 검토)

  • Seo, Kwang-Cheol;Nam, Taek-Kun;Park, Joo-Shin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.2
    • /
    • pp.237-243
    • /
    • 2019
  • Floating platforms made of PE (PolyEthylene) are often located in shallows of seas, rivers or lakes. They are widely used for marine pensions, marine pontoons, marine bridges, etc. These products are characterized by good flexibility, recyclability, chemical resistance and weatherability with corrosion resistance. Existing PE floating platforms have a simple structure in which one pipe is fastened to one bracket, but this has limited application, even if a user modifies the arrangement. Therefore, we developed a structure that allows buoyancy pipes of various sizes to be fastened to one bracket and verified the structural safety of the product using the finite element method. From the results of structural analysis for buoyancy pipes of different diameters, the maximum stress ratio was 0.78 compared with allowable criteria of 1.0, which represented sufficient safety for a model with 500 mm diameter pipes. Based on the results of this study, further research to evaluate the structural safety of various floating platforms can be carried out in the further; it will also be necessary to establish related evaluation criteria.

Development of Embedded Type Sensor Module for Measuring Stress of Concrete Using Hetero-core Optical Fiber (헤테로코어 광섬유를 이용한 콘크리트 응력 측정용 매립형 센서모듈의 개발)

  • Yang, Hee-Won;Lee, Hwan-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.68-75
    • /
    • 2022
  • In this study, in order to directly evaluate the prestress of the PSC structure, a new sensor module based on the measurement of the deformation of concrete was proposed using hetero-core optical fibers and performance tests were performed. In a hetero-core optical fiber, optical loss occurs when a specific part of the transmission path is bent, and the amount of optical loss changes linearly according to the magnitude of the curvature. In order to confirm the measurement performance of the sensor module and the applicability of the optical fiber, the sensor module was deformed and the light passing through the optical fiber was converted into wattage and measured. It can be seen that the light passing through the optical fiber has a linearity of 0.9333 in relation to the deformation while generating the maximum deformation of 0.5 mm at a rate of 0.12 mm/min in a cylindrical concrete specimen with a diameter of 15 cm and a height of 35 cm in which the sensor module is embedded. Based on the results of this experiment, it is judged that it is possible to directly evaluate the prestress of a PSC structure by embedding a sensor module using a hetero-core optical fiber in the structure and measuring the compression deformation in concrete. It is judged that it can be used as useful data for the development of a sheath tube integrated sensor module to be applied to be applied to the girder model experiment.

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

Effects of BCG on Gastric Chief Cells of the Mouse Implanted with Ehrlich Carcinoma Cells (BCG가 Ehrlich 암세포를 이식한 생쥐 위점막 으뜸세포의 미세구조에 미치는 영향)

  • Ryoo, In-Sang;Ahn, E-Tay;Park, Kyung-Ho;Park, Dae-Kyoon;Kim, Myeong-Soo;Ko, Jeong-Sik
    • Applied Microscopy
    • /
    • v.35 no.3
    • /
    • pp.153-163
    • /
    • 2005
  • This experiment was performed to evaluate the morphological responses of the gastric chief cells of the mouse, inoculated with Ehrlich carcinoma cells in the inguinal area, following administration of BCG (Bacillus Calmette-Guerin). Healthy adult ICR mice weighing 25 gm each were divided into normal and experimental groups (experimental control group and BCG treated group). In the experimental groups, each mouse was inoculated with $1x10^7$ Ehrlich carcinoma cells subcutaneously in the inguinal area. From next day after inoculations, 0.2 mL of saline or BCG (0.5 mL/25 g B.W.: $0.03{\times}10^8{\sim}0.32{\times}10^8$ CFU) were injected subcutaneously to the animals every other day, respectively. The day following the last injection, each mouse was sacrificed. Pieces of the tissue were taken from the stomach, prefixed with 2.5% glutaraldehyde-1.5% paraformaldehyde solution, followed by post-fixation with 1% osmium tetroxide solution. The ultrathin sections were stained with uranyl acetate and lead citrate. The size of zymogen granule and the size of the mitochondrion of the gastric chief cells were observed and calculated. In the BCG treated group, most chief cells did not show any difference in ultrastructure, except that myelin figures were more frequently observed, in comparison with that of nornmal control group. The size of zymogen granule in the gastric chief cells of normal control, experimental control and BCG-treated groups were $0.98({\pm}0.108){\mu}m,\;1.05({\pm}0.092){\mu}m\;and\;0.93({\pm}0.053){\mu}m$, respectively. And the mitochondrial size of the gastric chief cells of normal control, experimental control and BCG-treated groups were $0.80({\pm}0.130){\mu}m,\;0.83({\pm}0.143){\mu}m\;and\;0.72({\pm}0.078){\mu}m$, respectively. From the above results, it was concluded that BCG may slightly suppress function of the gastric chief cells.

The Contact Metamorphism Due to the Intrusion of the Ogcheon and Boeun granites (옥천화강암과 보은화강암 관입에 의한 접촉변성작용)

  • 오창환;김창숙;박영도
    • The Journal of the Petrological Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.133-149
    • /
    • 1997
  • In the metapelites around the Ogcheon granite, the metamorphic grade increases from the biotite zone through the andalusite zone to the sillimanite zone towards the intrusion contact. In the metabasites around the Boeun granite, the metamorphic grade increases from transitional zone between the greenchist and amphibolite facies through the amphibolite facies to the upper amphibolite facies towards the intrusion contact. In the Doiri area locating near the intrusion contact of the Boeun granite, sillimanite- and andalusite-bearing metapelites are found with in 500 m away from the contact. The evidence described above indicates that the Ogcheon and Boeun granites caused low-P/T type contact metamorphism to the country rocks. The P-T condition of contact metamorphism due to the intrusion of the Ogcheon granite is $540{\pm}40^{circ}C, 2.8{\pm}0.9$ kb. The temperature condition of contact metamorphism due to the intrusion of the Boeun granite is $698{\pm}28^{\circ}C$. The wide compositional range of amphibole and plagioclase in the metabasites around the Boeun granite is due to the immisibility gab of amphibole and plagioclase and unstable relict composition resulted from an incomplete metamorphic reaction. The compositional range of stable amphibole and plagioclase decreases as a metamorphic grade increases due to a close of immiscibility gab. The thermal effect of contact metamorphism due to the intrusion of the Ogcheon and Boeun granites, are calculated using the CONTACT2 program based on a two dimensional finite difference method. In order to estimate the thermal effect of an introduced pluton, a circle with 10 km diameter and a triangle with 20 km side are used for the intrusion geometries of the Ogcheon granite and the Boeun granite, respectively. The results from the field and modeling studies suggest that the intrusion temperatures of the Ogcheon granite close to $800^{\circ}C$ and the intrusion temperature of the Boeun granite is higher than $1000^{\circ}C$. However, the intrusion temperatures can be lower than the suggested temperature, if the geothermal gradient prior to the intrusion of the Ogcheon and Boeun granites was higher than the normal continental grothermal gradient.

  • PDF