• Title/Summary/Keyword: 체위측정

Search Result 54, Processing Time 0.032 seconds

Design of a Small Satellite-DMB Antenna (소형 위성 DMB 안테나 설계)

  • Chae, Gyoo-Soo;Kim, Min-Nyun;Lim, Joong-Soo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.291-293
    • /
    • 2006
  • 본 논문에서는 휴대용 무선통신기기에 장착해서 사용가능한 소형 위성 DMB 안테나를 설계하였다. 안테나 디자인은 QHA(Quadrifilar Helical Antenna)이며 소형화를 위해 안테나 패턴을 유전체위에 감고 각 패턴의 가운데가 분리된 형상을 하고 있다. 시뮬레이션 결과에 따라 안테나가 실제 제작 되고 측정되었다.

  • PDF

Cardiovascular Effects of Free Movement of Abdominal Muscle in Prone Positioning during General Anesthesia (전신마취동안에 복와위시 자유로운 복근 움직임이 심혈관계에 미치는 영향)

  • Kim, Ji-Yoon;Lee, Dong-Won;Seo, Il-Sook;Kim, Sae-Yeon
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.206-215
    • /
    • 2007
  • Background : The prone position is often used for operations involving the spine and provides excellent surgical access. The complications associated with the prone position include ocular and auricular injuries, and musculoskeletal injuries. In particular, the prone position during general anesthesia causes hemodynamic changes. To evaluate the cardiovascular effects of the prone position in surgical patients during general anesthesia, we investigated the effects on hemodynamic change of the prone position with the Jackson spinal surgery table. Materials and Methods : Thirty patients undergoing spine surgery in the prone position were randomly selected. After induction of general anesthesia, intra-arterial and central venous pressures (CVP) were monitored and cardiac output was measured by $NICO^{(R)}$. We measured stroke volume, cardiac index, cardiac output, mean arterial pressure, heart rate, CVP and systemic vascular resistance (SVR) before changing the position. The same measurements were performed after changing to the prone position with the patient on the Jackson spinal surgery table. Results : In the prone position, there was a significant reduction in stroke volume, cardiac index and cardiac output. The heart rate, mean arterial pressure and CVP were also decreased in the prone position but not significantly. However, the SVR was increased significantly. Conclusion : The degree of a reduced cardiac index was less on the Jackson spinal surgery table than other conditions of the prone position. The reduced epidural pressure caused by free abdominal movement may decrease intraoperative blood loss. Therefore, the Jackson spinal surgery table provides a convenient and stable method for maintaining patients in the prone position during spinal surgery.

  • PDF

統計學과 應용

  • 윤기중
    • The Korean Journal of Applied Statistics
    • /
    • v.2 no.1
    • /
    • pp.1-17
    • /
    • 1989
  • 本稿는 統計學의 理論 개척과 발전을 위해서 應用分野의 연구에 주력해야 할 필요성을 밝히려 한다. 우선 기존의 統計理論이 應用分野에서 生成 발전된 점을 밝히는 동시에 應用分野에 대한 연구의 관심을 확대시켜야 할 필요성을 설명하려 한다. 물론 數理統計學이나 確率論과 같은 分野는 論理的 硏究方法으로 數理解析의 발전이나 方法을 개척할 수가 있다. 그러나 그것도 人類의 福祉증진에 기여하게 된다는 최종적인 목적성이 전제된다면 현실의 應用分野와 결코 무관할 수는 없을 것이다. 이상과 같은 목적을 위해서 우선 統計學이 과학으로 성립하기 이전의 生成 배경을 설명하면서 統計學이 人間의 生活과 얼마나 밀접하고 그 대상이 얼마나 광범위한가에 대하여 설명하려 한다. 처음부터 그것은 個人生活보다는 集團生活과 더욱 밀접한 관계가 있었다는 점을 강조하게 된다. 그리고 20世紀初에 론돈大學의 生物測定硏究室, 겔톤優生學硏究室 등을 중심으로 한 웰든, 겔톤, 피어슨 그리고 네이만의 生物測定硏究와 數理統計學연구와 핏샤와 끄ㅅ 등의 연구업적에 의해서 統計學이 科學으로 성립된 歷史的 사실을 반취하면서 統計學의 연구방법과 대상을 간접적으로 인식하게 된다. 또 統計學이 他科學과 비교하여 硏究對象 方法 그리고 實踐的 側面에서의 學問的 特殊性을 설명하면서 統計學연구의 應用側面을 강조하게 된다. 끝으로 선구자들의 統計學연구방법과 태도를 조감하면서 어떻게 하면 새로운 統計的方法을 개척할 수 있고 또 他分理 연구에 기존의 統計的方法이 기여할 수 있는가의 方法을 탐색하게 될 것이다. 즉 專門硏究機關에서, 實務現場에서 새로운 硏究對象을 찾아 새 方法을 개척할 수 있는가 하는 문제를 論議하게 된다. 이러한 탐구는 모두 과거에 統計學발전에 기여한 여러 선구자들의 연구방법과 업적을 되새기면서 유도된다.격)개발에 관심을 가진 사람들이 모이는 일일 것이다. 통계분야에서도 몇가지 표준화 활동이 ISO 를 중심으로 진행되고 있다. 예를 들면 실험과 검증 결과의 표현과 해석, 표본추출 방법 등에 관한 것으로 이들은 통계의 응용분야에서 꼭 필요한 표준이다. 구체적인 예로서 우리나라 국민의 표준체위값을 설정하기 위하여 측정조사할 때 측정방법 뿐 아니라 표본추출 방법과 통계자료 처리과정의 표준화가 이루어 지지 않는다면 각 기관에서 조사 발표하는 체위관계 자료가 상이하여 국가기관의 통계자료에 대한 신뢰성이 저하되고 통계값을 이용하여 의류, 신발 등의 제품을 제조하는 산업계에 혼란을 야기시킬 수 있다. 본 고에서는 ISO의 활동을 정보처리 분야에 초점을 맞춰 간략하게 설명하고 통계분야의 국제 활동을 비전문가인 필자들이 아는대로 소개하는 한편 국내활동의 필요성을 강조하여 관련 기관, 학계 및 산업계 관련전문가들의 ISO 국내활동 참여를 제의하고자 한다.mes$E조합에서는 견층비율의 자잠에서, D$\times$F조합에서는 웅잠의 견층비율에서 비교적 높은 값을 나타내었다.

Basic Study Measuring Cow Body Parameters and Adjusting Her Postures for an Robotic Milking System (로봇 착유기를 위한 젖소 체위측정 및 자세조정의 기초 연구)

  • Kwon, D.J.;Kim, W.;Lee, D.W.
    • Journal of Animal Environmental Science
    • /
    • v.8 no.3
    • /
    • pp.171-176
    • /
    • 2002
  • Physical parameters of milk cow were measured to design and build RMS(Robotic Milking System) with a tape-measurer and body parameter measurer. The parameters are very important variables to design an RMS. For the working zone space of an RMS manipulator and the movement blunting of milk cow, an interval frame was installed on the stall bottom, and then cow's behavioral reactions were tested. The results from this study is summarized as follow. 1. On the general physical condition measurement, the maximum, minimum and average body length of cow which is related to the space that the manipulator could work into the RMS were 175cm, 144cm, and 163cm respectively. It appeared that the average distance between bottom and chest was 60cm. 2. The average length between fore teats, fore and hind teats and hind teats were 178mm, 150mm and 95mm respectively. It appeared that the average length between bottom and teat attachments was 544mm, and the average length between fore teats and tail-end was 331mm. 3. Although a cow kept a some extent length between hind legs for milking, it looked a stable pose. However, the cow kept a some extent distance between front legs for milking, it looked a unstable pose. Based on results of this test, an interval frame of stall bottom should be installed around the position which was located at its hind legs.

  • PDF

Evaluating Surface dose of Treatment Immobilization Devices according to their Electron Energy (전자선에너지에 따른 치료보조기구의 표면선량 평가)

  • Park, Chul-Woo;Im, In-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.360-363
    • /
    • 2010
  • This study evaluated surface dose of treatment immobilization devices such as Themo-plastic, Vac-lock, Cotton and Plaster according to their electron energy. Using a linear accelerater, a plane parallel chamber was set up on 6Mev, 9Mev, 12Mev and 15Mev. A distance between a source and a surface was 100cm and a field size was 10cm*10cm. An incident angle was 0 degree and a radiation dose was 100MU. To decrease an error, the measurement repeated 3 times. The analysis reveals that the surface dose of Vac-lock was the highest and Themo-plastic, Plaster and Cotton were high in order.

The Effects of Dielectric Passivation Overlayers for Submicron Thin Film Metallizations of ULSI Semiconductor Devices (초고집적 Submicron 박막금속화를 위한 Dielectric Overlayer의 Passivation 효과)

  • 김대일;김진영
    • Journal of the Korean Vacuum Society
    • /
    • v.3 no.1
    • /
    • pp.59-64
    • /
    • 1994
  • 극소전자 디바이스의 고집적화와 더불어 박막배선의 선폭은 0.5$\mu$m이하까지 축소되며 초고집적 submicron 박막금속화가 진행되고 있다. 미세회로에 적용되어지는 배선재료는 인가되는 고전류밀도로 인하여 electromigration 에 의한 결함이 쉽게 발생한다는 단점이있다. 금속박막 전도체위의 dielectric overlayer는 electromigration 에 대한 passivation 효과를 보여 극소전자 디바이스의 평균수명을 향상시 킨다.본 연구에서는 박막금속화에서 dielectric overlayer의 passivation 효과를 알아보기 위하여 약 3000 $\AA$ 두께의 Al,Al-1%Si, Ag 그리고 Cu 박막배선위에 증착하여 SiO2절연보호막의 유무에 따른 박막배선 의 수명변화 및 신뢰도를 측정하였다. 박막배선에 인가된 전류밀도는 1x106 A/cm2와 1x107 A/cm2 이었다. SiO2 dielectric overlayer는 Al,Al-1%Si Ag. Cu 박막배선에서는 electromigration에 대한 보호막 혀과를 보이며 평균수명을 모두 향상시킨다. SiO2 passivation 효과는 Al, Ag, Cu 박막중 Cu 박막배선에서 가 장 크게 나타났다. SiO2 dielectric overlayer가 형성되지 않은 경우 Al 박막배선의 수명이 가장 긴 것으 로 나타났으나 SiO2 가 형성된 경우는 Cu 박막배선의 수명이 가장 길게 나타났다.

  • PDF

Development of Continuous ECG Monitor for Early Diagnosis of Arrhythmia Signals (부정맥 신호의 조기진단을 위한 연속 심전도 모니터링 기기 개발)

  • Choi, Junghyeon;Kang, Minho;Park, Junho;Kwon, Keekoo;Bae, Taewuk;Park, Jun-Mo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.2
    • /
    • pp.45-50
    • /
    • 2021
  • With the recent development of IT technology, research and interest in various bio-signal measuring devices are increasing. But studies related to ECG(electrocardiogram), which is one of the most representative bio-signals, particularly arrhythmic signal detection, are incomplete. Since arrhythmia has various causes and has a poor prognosis after onset, preventive treatment through early diagnosis is best. However, the 24-hour Holter electrocardiogram, a tool for diagnosing arrhythmia, has disadvantages in the limitation of use time, difficulty in analyzing motion artifact due to daily life, and the user's real-time alarm function in danger. In this study, an ECG and pulse monitoring device capable of continuous measurement for a long time, a real-time monitoring app, and software for analysis were developed, and the trend of the measured values was confirmed. In future studies, research on derivation of quantitative results of ECG signal measurement analysis is required, and further research on the development of an arrhythmic signal detection algorithm based on this is required.

The Respiratory and Hemodynamic Effects of Prone Position According to the Level of PEEP in a Dog Acute Lung Injury Model (잡종견 급성폐손상 모델에서 Prone position 시행시 PEEP 수준에 따른 호흡 및 혈류역학적 효과)

  • Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.140-152
    • /
    • 1998
  • Background: Prone position improves oxygenation in patients with ARDS probably by reducing shunt Reduction of shunt in prone position is thought to be effected by lowering of the critical opening pressure (COP) of the dorsal lung because the pleural pressure becomes less positive in prone position compared to supine position. It can then be assumed that prone position would bring about greater improvement in oxygenation when PEEP applied in supine position is just beneath COP than when PEEP is above COP. Hemodynamically, prone position is expected to attenuate the lifting of cardiac fossa induced by PEEP. Based on these backgrounds, we investigated whether the effect of prone position on oxygenation differs in magnitude according to the level of PEEP applied in supine position, and whether impaired cardiac output in supine position by PEEP can be restored in prone position. Methods: In seven mongrel dogs, $PaO_2/F_1O_2$(P/F) was measured in supine position and at prone position 30 min. Cardiac output (CO), stroke volume (SV), pulse rate (PR), and pulmonary artery occlusion pressure (PAOP) were measured in supine position, at prone position 5 min, and at prone position 30 min. After ARDS was established with warmed saline lavage(P/F ratio $134{\pm}72$ mm Hg), inflection point was measured by constant flow method($6.6{\pm}1.4cm$ $H_2O$), and the above variables were measured in supine and prone positions under the application of Low PEEP($5.0{\pm}1.2cm$ $H_2O$), and Optimal PEEP($9.0{\pm}1.2cm$ $H_2O$)(2 cm $H_2O$ below and above the inflection point, respectively) consecutively. Results : P/F ratio in supine position was $195{\pm}112$ mm Hg at Low PEEP and $466{\pm}63$ mm Hg at Optimal PEEP(p=0.003). Net increase of P/F ratio at prone position 30 min, however, was far greater at Low PEEP($205{\pm}90$ mm Hg) than at Optimal PEEP($33{\pm}33$ mm Hg)(p=0.009). Compared to CO in supine position at Optimal PEEP($2.4{\pm}0.5$ L/min), CO in prone improved to $3.4{\pm}0.6$ L/min at prone position 5 min (p=0.0180) and $3.6{\pm}0.7$ L/min at prone position 30 min (p=0.0180). Improvement in CO was attributable to the increase in SV: $14{\pm}2$ ml in supine position, $20{\pm}2$ ml at prone position 5 min (p=0.0180), and $21{\pm}2$ ml at prone position 30 min (p=0.0180), but not to change in PR or PAOP. When the dogs were turned to supine position again, MAP ($92{\pm}23$ mm Hg, p=0.009), CO ($2.4{\pm}0.5$ L/min, p=0.0277) and SV ($14{\pm}1$ ml, p=0.0277) were all decreased compared to prone position 30 min. Conclusion: Prone position in a dog with saline-lavaged acute lung injury appeared to augment the effect of relatively low PEEP on oxygenation, and also attenuate the adverse hemodynamic effect of relatively high PEEP. These findings suggest that a PEEP lower than Optimal PEEP can be adopted in prone position to achieve the goal of alveolar recruitment in ARDS avoiding the hemodynamic complications of a higher PEEP at the same time.

  • PDF

Optimal Slit Length Limit of Tight Skirts in Movement and Physiological Response (동작에 따른 타이트 스커트 최소 적정 트임량과 생리적인 반응)

  • Kim, Hee-Eun;Lee, Jung-Sug
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.12
    • /
    • pp.1390-1396
    • /
    • 2003
  • 본 연구는 타이트 스커트의 트임의 개수가 왼쪽 옆선에 1개 있을 때와 왼쪽 옆선, 오른쪽 옆선에 각각 1개씩 모두 2개 있을 때 평지 보행, 계단 승강, 버스 승강 등과 같은 일상동작에 잘 적응할 수 있는 타이트 스커트의 적정 트임 길이를 설정하는 것을 목표로 하였다. 아울러 각 동작시의 트임 길이에 따른 생리적인 반응을 의복압, 산소 섭취량을 통해 알아보고자 하였다. 평균보폭은 4m 구간을 평상시대로 걸을 때의 발자국간 평균거리를 이용하였으며 국민표준체위조사보고서(1997)에 의한 평균체형을 가진 9명의 피험자를 정하였다. 스커트의 형태는 무릎길이인 타이트 스커트로 정하였다. 스커트의 트임은 왼쪽 옆선에 1개 있는 경우와 왼쪽 옆선, 오른쪽 옆선에 각각 1개씩 있는 경우의 2종류이다. 트임이 1개인 스커트는 2cm 간격으로, 트임이 2개인 스커트는 1cm 간격으로 트임 위치를 표시하여 길이를 조정하였다. 적정 트임 길이는 Likert 척도에 의한 만족도 평가로 측정하였으며 의복압은 air-bag system으로, 산소 섭취량은 Quark $B^2$ 으로 측정하였다. 본 연구의 결과는 다음과 같다. 1. 스커트의 최소 적정 트임 길이는 트임 1개일 때 평지 보행시 4cm, 계단 승강시 12cm ,버스 승강시 18cm이며, 트임 2개일 때 평지 보행시 2cm, 계단 승강시 8cm, 버스 승강시 15cm로 나타났다. 2. 의복압의 경우, 동일 트임 길이에서 트임 1개의 의복압이 트임 2개의 의복압보다 높았지만 트임 개수에 따른 전체 트임 길이로 보면 트임 1개의 의복압이 트임 2개의 의복압 보다 낮게 나타났다. 동작별로는 버스 승강의 의복압이 가장 높고 계단 승강, 평지 보행 순으로 낮아졌다. 3. 산소 섭취량의 경우, 동일 트임 길이에서 트임 1개와 트임 2개의 산소 섭취량은 거의 비슷하였다. 트임 개수에 따른 전체 트임 길이로 보면 트임 1개의 산소 섭취량이 트임 2개의 산소 섭취량보다 낮게 나타났다. 동작별로는 버스 승강의 산소 섭취량이 가장 높고 계단 승강, 평지 보행 순으로 낮아졌다.

A Study on the Middle-Aged Women's Body Type Changes for Clothing Construction - Focused on the 5th and 6th Size Korea's Anthropometric Data - (의복 설계를 위한 중년 여성의 체형 변화에 관한 연구 - 제 5차, 제 6차 Size Korea 직접 측정치를 기준으로 -)

  • Nam, Young Ran;Choi, Hei Sun;Lee, Jin Hee
    • Fashion & Textile Research Journal
    • /
    • v.15 no.4
    • /
    • pp.583-595
    • /
    • 2013
  • In the women's clothing industry that targets middle aged-women, there is increased interest on middle-aged women and their appearance management and diet. It is believed that the body type of middle-aged women is becoming thinner. This study examines if middle-aged women body types have changed based on data from the $5^{th}$ and $6^{th}$ Size Korea that objectively analyzed the aspects of middle-aged women's body size change and the related fashion industry that recognize changes in middle-aged women body types by suggesting foundational data for clothing designs. According to research results, middle-aged women's body type shows an increase in items related to height and that measurement values related to obesity (such as weight and BMI index) tend to decrease. Height has increased and weight has decreased compared to the past. Most items related to width or depth tend to show decreased values and we can assume that the present middle-aged women's body type is changing more dynamically than before. It will be possible to design proper clothes for consumer body type and trends if we design clothes that afford multilateral attention to the patterns, design, or material in clothing design by applying the aspects of middle-aged women's body size and body type change.