• 제목/요약/키워드: 체온조절

검색결과 121건 처리시간 0.029초

겨울철 전자 기기 사용을 위한 전도성 보온장갑의 착용성 평가 - 손의 기민성과 사용성, 체온조절 반응을 중심으로 - (Performance of Conductive Gloves When Using Electronic Devices in a Cold Environment - Manual Dexterity, Usability and Thermoregulatory Responses -)

  • 권주연;정다희;김시연;정원영;이주영
    • 한국의류산업학회지
    • /
    • 제22권5호
    • /
    • pp.686-695
    • /
    • 2020
  • The present study evaluated the manual dexterity and usability of conductive gloves when operating touchscreen devices in the cold. Twelve male subjects (23.3±1.5 years in age) participated in three experimental conditions: no gloves, fabric conductive and lambskin conductive gloves. Manual dexterity was tested using both Purdue Pegboard (PP) and ASTM dexterity tests at an air temperature of 5℃ and air humidity of 30%RH. Glove usability was tested through the following touchscreen tests: tap, double tap, long tab, drag, flick, and multi-touch. The results showed that manual dexterity according to the PP (2.5 mm of a pin diameter) and ASTM tests (8 mm of a stick diameter) was worse for the two glove conditions than for the no glove condition (p<.005). PP dexterity was better for the fabric glove condition than for the lambskin glove condition (p<.05); however, there was no difference in ASTM dexterity between the two glove conditions. Hand and finger skin temperatures were higher for the glove conditions than the bare hand condition (p<.05), with no differences between the two glove conditions. The touchscreen usability was the best for the no glove condition, followed by fabric gloves (p<.05). Wearing either fabric or lambskin gloves diminishes hand dexterity while maintaining hand and finger temperatures at higher levels. For improved hand dexterity in dealing with small numbers, letters on a touchscreen in cold environments, we recommend wearing fabric conductive gloves rather than lambskin conductive gloves.

서열환경하에서의 전투복착용이 체온조절에 미치는 영향 (The Influence of Wearing Army Combat Uniform on the Thermal Responses in Heat Environment)

  • 김태규;조호현
    • 한국의류산업학회지
    • /
    • 제16권1호
    • /
    • pp.167-174
    • /
    • 2014
  • The physical properties of textile materials and thermal physiological responses of the human subjects were evaluated with 4 different types of the army combat uniforms including US, German, Korean and general uniforms for this study. 8 male adults were used as the human subjects and the tests were done in the environmental chamber that was $25{\pm}0.1^{\circ}C$ of temperature, $65{\pm}5%$ of relative humidity and below 0.3 m/sec of air velocity. The test protocol consisted the rest period for 20 min., the exercise period for 20 min., the rest period for 20 min., the exercise period under wind condition for 20 min., and the recovery period for 20 min. The human subjects walked with 4.5 km/hr for 10 min., ran 7.5 km/hr for 10 min. during the first exercise period and walked and ran with the same speeds under 3.5 m/sec of the air velocity that simulated outdoor condition during the second exercise period. The test results of the study were as follows; The wind condition affected the skin and microclimate temperature of the human subjects lower compared to without wind condition, but had insignificant effect on the humidity control. The low air permeability of Korean uniform caused blocking the elimination of the humidity from the body and the regulation of body temperature. However, Korean uniforms could be the excellent one with the designs considering the ventilation of the uniforms and the textile fabrics with better air permeability.

PCM 가공과 3차원 인체 모델링 기술을 적용한 노년 여성용 기능성 언더웨어 설계 (Functional Underwear Development for Elderly Woman from 3D Body Model applying PCM treatment)

  • 최신애;김태규;박영민;신지영;박순지
    • 한국의류산업학회지
    • /
    • 제18권4호
    • /
    • pp.457-467
    • /
    • 2016
  • This study aimed to develop functional underwear for elderly women in their sixties in terms of good fit, wear comfort and body temperature regulation. To satisfy elderly women's physical and metabolical needs, an automatic temperature control system via PCM treatment was applied. Underwear pattern was produced by producing body surface replica, which was derived from 3D body parametric model. Differential ratios of outline length and area between 3D surface and 2D plane were 1.4% and 0.5%, respectively. The reduction rate was determined as 10% through the expert's evaluation. PCM treated fabric showed higher Q-max, meaning that it can facilitate the thermal transition in hot situation. Moreover, it also showed higher insulation to preserve heat and keep warm microclimate in a cold weather. Heat distribution measurements on various body parts revealed that the temperature after PCM treatment was significantly higher. The clothing pressure after 10% pattern reduction showed higher before reduction, at the same time, even lower than the comfort clothing pressure range of $5{\sim}10gf/cm^2$, implying that experimental garment of this research is acceptable in terms of clothing pressure. Evaluation results on the comfort to move in various motions proved that adequate clothing pressure improved the wear comfort in various motions.

신체의 부위별 피복이 체온조절 및 주관적인 감각에 미치는 영향(II) (Effects of Covering Parts of Body with Garments on Human Thermoregulation and Sensation(II))

  • 이종민
    • 한국의류학회지
    • /
    • 제18권3호
    • /
    • pp.339-347
    • /
    • 1994
  • In this study the physiological significance of the upper and lower body on thermoregulation and sensation are examined. Experiments were carried out on 4 females in a climatic chamber conditioned at $25\pm1^{circ}C, 50\pm5%$ R.H.. Before the measurements, subjects were exposed to 3 types of enviromental temperature: 1) $25\pm1^{\circ}C$ for 60 min.(ST), 2) $25^{\circ}C$\rightarrow35^{circ}C\rightarrow25^{\circ}C$ for about 40 min.(HT), 3) $25^{\circ}C$\rightarrow15^{circ}C\rightarrow25^{\circ}C$ for about 40 min.(LT) covering the upper body (U) or lower body (L) with garments. 1) $T_{re}$ was significantly higher in L than in U only in 57 condition. $T_{sk}$ and Temp. under the clothing were higher in U than in L in all three conditions. Thermal sensation was warmer in U than in L, and comport sensation was most comfortable in HT condition. 2) When the upper or lower body was covered or exposed, the mean skin temperature of the upper body was higher than that of the lower body. Following covering and uncovering the same area, the changes in skin temperature were greater in the upper body than in lower body, and covering the upper body produced a greater difference of skin temperature between body and lower body than covering the lower body. 3) In all environmental conditions, when the upper body was uncovered, the skin temperatures of the chest, upper arms and forearms dropped to a considerable degree, and when the lower body was uncovered, skin temperatures of the legs showed the same pattern. On the other hand, skin temperature of the thinghs showed only little change in all cases except forehead and back uncovered or covered in two clothing types.

  • PDF

원적외선 방사 기능 실내복 착용이 인체 피부혈류량, 온열 심리 및 온열 생리 기능에 미치는 영향 (Influences of Wearing Far-infrared Indoor Clothing on Skin Blood Flow, Perceptual and Thermal Responses)

  • 백윤정;서원지;김형찬;이주영
    • 한국의류학회지
    • /
    • 제44권2호
    • /
    • pp.342-353
    • /
    • 2020
  • The purpose of this study was to evaluate far-infrared clothing (FIR condition) with non-far-infrared clothing (Control condition) to assess the effects of FIR on thermo-physiological responses. Eight young healthy males (23.0±2.3 yr, 176.5±3.7 cm, and 69.0±4.3 kg) participated in this experimental trial, which consisted of a 20 min rest followed by a 40 min walk (4.0 km·hr-1) and a 20 min recovery at 20℃ with 50%RH. The results showed that finger skin blood flow and mean skin temperature were significantly higher for the FIR condition than the control during exercise and recovery (p<.001). Clothing microclimate temperature of the FIR condition was 0.5℃ higher on the back (p=.001) and 0.4℃ higher on the thigh (p=.015) during recovery. Clothing microclimate relative humidity of the FIR condition was 13% higher on the chest (p=.006) and 19% higher on the back (p<.001) during exercise than control. Subjects felt warmer and more comfortable in the FIR condition than in the control (p<.05). Perceived skin wettedness (%BSA) was less in the FIR condition than in the control (p=.001). These results indicate that ceramic-embedded clothing had significant effects on thermoregulatory responses for light activity in an indoor environment.

소비자 조사와 착의 실험을 통한 온도감응형 기능성 의류개발을 위한 기초연구 (Thermo-sensitive Clothing Development by Consumer Investigation and Wearing Test)

  • 상정선;정경화;박주현;오경화
    • 한국의류산업학회지
    • /
    • 제19권1호
    • /
    • pp.90-100
    • /
    • 2017
  • In this research, consumer awareness investigation and wearing test were carried out for obtaining useful data on the development of thermo-sensitive functional clothing material. A survey involved 216 people in Seoul and Kyeonggi-do, and 200 questionnaires data were analyzed by descriptive statistics and frequency using SPSS 17.0. Four healthy men in twenties were participated for wearing test. Subjects in normal loungewear were exposed to temperature change from the initial temperature $30^{\circ}C$ down to $5^{\circ}C$ for an hour in a climate chamber. The environmental temperature, surface temperature of garment and skin were measured. As a result, most of respondents have all season clothing products such as underwear, hosiery, and jogging suit for loungewear. Also, thermo regulator y functional clothes are frequently used as underwear and sweat shirt. The consumer awareness investigation on thermo regulatory functional clothing showed that the most important key buying factor is quick climate temperature response, easy maintenance, design and cost, in that order. Surface temperature of garment went down with the cooling down of environmental temperature. The lower environmental temperature, the greater temperature difference by body part showed. Skin temperature change by environmental temperature showed similar tendency of garment surface temperature. In comparison between garment surface and body skin, temperature difference became larger under the lower environmental temperature.

농약 방제 작업자의 작업 환경 및 노동 부담 평가 (Evaluation of the thermal environments and the workload of farmers during the spraying pesticide in the rice field)

  • 최정화;이주영
    • 한국의류학회지
    • /
    • 제26권11호
    • /
    • pp.1672-1681
    • /
    • 2002
  • To evaluate the thermal environments and the workload of farmers in the rice field in summer, this study investigated rice farmers' physiological, psychological responses, work postures, work clothes, air temperature and air humidity during the spraying pesticide in the rice field. Five career farmers (3 males, 2 females) volunteered as the subjects. During the spraying pesticide in the rice field, physiological responses were monitored continuously. The results were as follows. l. Farmers wore only raincoats not pesticide-proof clothing. 2. The value of WBGT, rectal temperature($T_{re}$), mean skin temperature(${\={T}}_{sk}$) were $24.9∼28.9^{\circ}C,\;37.8({\pm}0.3)^{\circ}C\;and\;33.6({\pm}0.6)^{\circ}C$, respectively. Clothing microclimate temperature($T_{cl}$) on the chest and back were $32.5({\pm}2.6)^{\circ}C\;and\;33.6({\pm}2.6)^{\circ}C$, respectively(p<0.00l). Humidity inside of the clothing ($H_{cl}$) was over 80%RH and heart rate(HR) was 112(${\pm}27$)bpm. We evaluated that the spraying pesticide was 'heavy work' by the Tre and HR. To four subjective questionnaires, all farmers expressed 'hard, hot, humid and uncomfortable' without individual difference at the end of works. We suggested that 1) the spraying pesticide in the rice field was a heavy work, 2) because the workload of farmers in the raincoat/pesticide-proof clothing can't be evaluated by only WBGT, assessors should measure physiological, psychological responses as well as thermal environments, 3) to alleviate farmers' heat strain, clothing manufacturers must consider not only the improvement of textile materials and clothing weight but also the designing of personal cooling equipment.

피지이론과 바이오피드백을 이용한 주정중독증 환자의 긴장도 평가 (Estimation of Tension Status for Alcohol Dependent Patients using Biofeedback Training and Fuzzy Theory)

  • 성홍모;시재우;윤영로;윤형로;박진한;신정호
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권2호
    • /
    • pp.191-198
    • /
    • 1999
  • 바이오피드백은 혈압 심박율, 말초체온, 호흡, 근전도 등과 같이 자율신경에 의해 지배받는 신체 기능들을 훈련을 통해 스스로 조절할 수 있게 하여 자율신경의 이상으로 인한 여러 가지 질병들을 치료할 수 있게 하는 방법이다. 븐 논문에서는 주정중독증 환자들을 대상으로 바이오피드백 훈련을 실시할 수 있도록 근전도, 호흡, 맥파, 말초체온, 피부전기전도도 등 다섯 가지 신호를 측정할 수 있는 바이오피드백 시스템을 개발하였다. 개발된 시스템을 이용해 주정중독증 환자들을 대상으로 바이오피드백 훈련을 실시하였다 이완 바이오피드백 훈련을 실행하였으며 생체신호변화에 대해 퍼지이론을 적용하여 긴장상태를 판단하였다. 8명의 주정중독증 환자들이 실험에 참가하였으며 측정된 데이터를 분석한 결과는 다음과 같다. 1) 환자 군은 일반인에 비해서 높은 긴장도 값을 보였다. 2) 환자들의 긴장도 값은 훈련 회수가 증가함에 따라 감소하는 추세를 보였다.

  • PDF

철도 차량 정비 작업자를 위한 일회용 부직포 작업복의 온열적 성능 평가 (Evaluation of the Thermal Properties of Disposable Coveralls for Railroad Carriage Maintenance Workers)

  • 최정화;이주영;김소영
    • 한국의류학회지
    • /
    • 제28권8호
    • /
    • pp.1175-1185
    • /
    • 2004
  • This study evaluated thermo-physiological and subjective properties of improved disposable coveralls for railroad carriage maintenance through climatic chamber trials and a filed study. Subjects wore five kinds of disposable coveralls (Type A: a disposable coverall on the market, Type B: a coverall with an improved hood and size-adjustable design, Type C: a coverall with a portable hood, Type D: a coverall with small holes for ventilation, Type E: a sleeveless coverall, Type F: a separated type of coverall with half sleeves) The air temperature in the climatic chamber was set in 9$^{\circ}C$ and 30$^{\circ}C$ For each condition, subjects simulated the railroad work for 120min. and rectal temperature, skin temperatures, clothing microclimate and subjective sensations were measured. The results of chamber trials showed rectal temperature and clothing microclimate did not display significant differences by clothing type. In 30$^{\circ}C$ air temperature, mean skin temperature was higher in Type E and Type F than in Type A(p<0.05) but between the improved coveralls(B-F), we could not find any significant difference. In the case of thermal comfort, the most preferred types were Type B and Type C in 9$^{\circ}C$ and Type F in 30$^{\circ}C$. All subjects felt more comfortable in the improved coveralls than in coveralls of the market (Type A). In field study, workers preferred Type B, Type C and Type F to Type A but the most favorite type differed by the specific type of work. Especially, workers were dissatisfied that Type D tore easily due to lots of small holes around the armpits and Type I did not protect workers' shoulder and arms from oil contamination. According to the climatic chamber trials and field study, the most effective coveralls were Type B and Type C for winter and Type F for summer.

능동적 압력조절이 가능한 약물주입기 구현 (Implementation of The Drug Infuser with Active Pressure Control Method)

  • 조성범;노윤홍;문창수;정도운
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.817-818
    • /
    • 2012
  • 본 연구에서는 치과에서 마취 시 환자들의 고통을 최소화 하기위하여 무통마취를 위한 치과용 약물주입기를 구현하였다. 약물의 주입 시 통증을 최소화하기 위해서 온도를 $36{\pm}2^{\circ}C$ 범위로 제어하여 체온과 유사한 온도로 유지하였다. 이를 위하여 필름히터 방식을 이용한 치과범용국소약물(36mg, 2% 리도카인) 앰플 가열부를 설계하였다. 또한 약물이 주입되는 양을 능동적으로 제어하기 위하여 약물주입 환부의 환자별 흡수 속도 차이에 차등 주입을 위한 압력 측정 시스템을 구현하였다. 필름 형태의 압력 센서를 통하여 전달 압력을 측정하였으며 측정된 압력을 바탕으로 능동적으로 모터의 동작을 제어함으로써 약물주입시 환자의 고통을 최소화 할 수 있도록 구현하고자 하였다.

  • PDF