• Title/Summary/Keyword: 체열진단

Search Result 54, Processing Time 0.021 seconds

Observation of the change of body temperature during the adaptation time in D.I.T.I (2) (적외선체열진단을 위한 외부온도 적응과정 중 체온변화 관찰 (2))

  • Park, Dae-Soon;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.3 no.1
    • /
    • pp.52-59
    • /
    • 2004
  • Purpose This study was peformed to observe the change of body temperature during preparatory period. Method This study was carried out on 92 patients by D.I.T.I. The temperature was measured on Chondol(CV22), chonjung(CV17), the abdominal region and palm of Rt. and Lt. hand on every minutes for ten minutes. Result and Conclusion In male and female, until 6 minutes mean body temperature decreased but from 7 minutes it increased a little. In chonjung(CV17) and the abdominal region, temperature increased continously for ten minutes. However in palm of Rt. and Lt. hand it decreased continously for ten minutes

  • PDF

A study on the method for thermal imaging of each abdominal region (복부 영역별 체열 영상 획득 방법 연구)

  • Kim, Keun Ho;Choi, Woosu
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.397-399
    • /
    • 2021
  • 한의사의 복진을 모사하는 진단기기와 이를 이용하여 질환과 변증을 분류하는 알고리즘을 개발하는 연구가 진행되고 있다. 본 연구에서 적외선 체열 영상과 접촉식 온도계로부터 구성되는 복부 영역별 체열 영상 시스템을 제시하였고, 복부 영역의 절대 온도를 보정하는 방법을 살펴보았다. 접촉식 온도계를 활용해 추가로 복부표면 온도를 측정하였고, 동시에 열화상 카메라로도 영상을 촬영하여, 동일위치에서 열화상 영상의 온도값과 접촉식 체온계의 온도값을 비교해 전체 열화상 영상을 보정하였다. ICC 값이 0.96으로 나와 높은 재현성을 보였다.

Measurement of ROI Temperature in Herniation of Intervertebral Disc Patients Using DITI (디지털 적외선 체열진단기를 이용한 추간판탈출증 환자의 ROI 온도측정)

  • Park, Jeong Kyu;Park, Jong Sam;Kwon, Soon Mu
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.273-278
    • /
    • 2017
  • Among 45 patients of herniation of intervertebral disc with $L_4$ to $L_5$ herniation, who underwent infrared thermography, the number of female was larger than male and the age of 50s was highest. From the results measured from the distribution table, we have confirmed that there was no significant difference depending on sex and age (p> 0.05). The region of the highest ROI temperature for patients with $L_4-L_5$ intervertebral disc prolapse was the back of the posterior right tibia, and followed by the back of the left shin bone-below the front right knee-below the front left knee. There was a significant difference depending on the measured site. The average ROI temperature for patients was $30.30{\pm}0.50$ whereas that for normal persons was $31.20{\pm}0.58$, yielding the temperature difference of $0.66{\pm}0.59$ between the two groups. The ROI of patients was lower than $31.20{\pm}0.58$ (p <0.05) because the significance of the sample, which has been obtained from the results of a sample t-test, was less than 0.05 (p <0.05). From further researches, it may necessary to develope the methodology for correcting data regarding thermal environment and, in addition, to develope a new thermal index based on it. Therefore, we can confirm that pre-treatment for infrared thermography is very important in order to minimize the procedure for correcting data. It is required that radiologists who inspect disc herniations should carefully observe and consider the patients during their measurements.

A Clinical case study for the diagnosis and assessment of abdominal cold hypersensitivity treatment by DITI (적외선 체열검사(DITI)로 복부냉증의 진단과 치료 경과를 평가한 단일 임상례)

  • Kim, Eun-Gyung;Hwang, Deok-Sang;Lee, Chang-Hoon;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.7 no.1
    • /
    • pp.55-65
    • /
    • 2009
  • Purpose: This study was performed to evaluate DITI (Digital Infrared Thermographic Imaging)'s potential for diagnosis and indicator of abdominal cold hypersensitivity treatment from the clinical case study. Methods: The patient was a 35-year-old woman who was suffered by general coldness, sweating and general pain. The patient was treated by Herb medicine, Acupuncture treatment, Moxa treatment and Physical Treatment. The progress of symptoms was evaluated by checking the change of VAS, and inspecting the DITI. We studied the statistical significance from the difference of DITI results before and after treatment by paired T-test using SPSS windows (version 12.0). Results: The general coldness, sweating and general pain of this patient have declined, especially the abdominal coldness improvement showing. As a results, the temperature of four abdominal sites(GV4,6,12,17) after treatment were statistically higher than those before treatment. With comparison of Indang, DITI difference of abdominal sites before and after treatment were statistically significant from paired T-tests. Conclusion: The results suggest that DITI can be used for the diagnosis and assessment of abdominal cold hypersensitivity treatment.

  • PDF

Observation of the change of body temperature during the adaptation time in D.I.T.I (1) (적외선체열진단을 위한 외부온도 적응과정 중 체온변화 관찰 (1))

  • Park, Dae-Soon;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.3 no.1
    • /
    • pp.20-26
    • /
    • 2004
  • Purpose This study was performed to observe the change of body temperature during preparatory period. Method This study was carried out on 19 patients by D.I.T.I. The temperature was measured on Chondol(CV22), chonjung(CV17), the abdominal region and palm of Rt. and Lt. hand on every minutes for ten minutes. Result and Conclusion In male and female, until 6 minutes mean body temperature decreased but from 7 minutes it increased a little. Temperature in Chondol(CV22) and chonjung(CV17) also had similar tendency. However in the abdominal region temperature decreased and in palm of Rt. and Lt. hand it increased continously for ten minutes

  • PDF

Performance Evaluation of the Developed Diagnostic Multi-Leaf Collimator and Implementation of Fusion Image of X-ray Image and Infrared Thermography Image (개발한 진단용 다엽조리개 성능평가 및 X선영상과 적외선체열영상의 융합영상 구현)

  • Kwon, Soon-Mu;Shim, Jae-Goo;Chon, Kwon-Su
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.365-371
    • /
    • 2019
  • We have developed and applied a diagnostic Multi-Leaf Collimator (MLC) to optimized the X-ray field in medical imaging and the usefulness evaluated through the fusion of infrared image and X-ray image acquired by infrared camera. The hand and skull radiography with multi-leaf collimator(MLC) showed significant area dose reductions of 22.9% and 31.3% compared to ARC and leakage dose was compliant with KS A 4732. Also scattering doses of 50 cm and 100 cm showed a significant decrease to confirm the usefulness of MLC. It was confirmed that the fusion of infrared images with an adjustable degree of transparency was possible in the X-ray images. Therefore, fusion of anatomical information with physiological convergence is expected to contribute and improvement of diagnostic ability. In addition, the feasibility of convergence X-ray imaging and DITI devices and the possibility of driving MLC with infrared images were confirmed.

Infrared thermographic imaging in patients with alopecia. (탈모 환자의 적외선 체열 진단상 안면부 체열 특성)

  • Yi, Tae-Hoo;Moon, Jung-Bae;An, Kyung-Eh;Lee, Hye-Jung
    • Journal of Oriental Medical Thermology
    • /
    • v.5 no.1
    • /
    • pp.78-86
    • /
    • 2006
  • Objectives: To examine any potential relationships between the types of alopecia and the facial heat distribution in patients with alopecia Methods: 183 patients with alopecia participated in this study to provide facial heat distribution measured by the Infrared Thermography Scanner (ITS, Nec San-ei Instruments Ltd, Japan). The thermography scan was used in a light-and heat-protected room after 20 minutes’of resting period. 1.5m of distance maintained between the patients and ITS. Results: Specificity in the type of facial heat distribution was found as follow. 1. Types of facial heat distribution can be classified as T-type and diffused patterns. 2. There was a significant difference in the pattern of facial heat distribution among different types of alopecia (p=0.002): facial heat distribution appeared T-type in Androgenic Alopecia, Alopecia Areata, and Telogen Effluvium (71.3%, 85.7%, 70.4%), whereas diffused pattern was dominant in Seborrheic Alopecia(55.6%). 3. There was a significant difference in the pattern of facialheat distribution between men and women (p<0.001): While the T-type and diffused type were equally appeared in men (50.6%: 49.4%), T-type was dominant in women (88.0% vs. 12.0%). Conclusions: We conclude that the pattern of facial heat distribution differs depends on the types of alopecia and gender. These differences may provide useful information for the diagnosis and clinical therapy for this population.

  • PDF

A Clinical Evaluation of DITI and Neurometer for the Diagnosis of Cold Hypersensitivity (냉증 진단을 위한 DITI와 말초신경검사의 임상적 평가)

  • Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.3 no.1
    • /
    • pp.60-66
    • /
    • 2004
  • Purpose This study is to examine of Neurometer for the diagnosis of cold hypersensitivity Method Among patients who visited the oriental gynecological department in Kangnam Korean Hospital from October. 2000 to December. 2000, 37 women were diagnosed as cold hypersensitivity by D.I.T.I. We measured the limbs' temperature by D.I.T.I. and Current perception threshold(CPT) of median N., ulnar N., radial N., peroneal N., sural N., tibial N., saphenous N. by neurometer Patients were divided into mild and severe group depending on the temperature difference between proximalis and distalis in limbs Result and Conclusion 1. In severe group, CPT of median N., ulnar N., radial N. was higher on 250Hz and 200Hz. 2. In severe group, Mean CPT of peroneal N., sural N., tibial N., saphenous N. was higher on every Hz.

  • PDF

Evaluation of Thermography Camera Using Molded Optical Lens for Medical Applications (몰드성형 광학렌즈를 이용한 의료기기용 열화상카메라 체열진단의 적용도 평가)

  • Ryu, Seong Mi;Kim, Hye-Jeong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.8
    • /
    • pp.624-628
    • /
    • 2013
  • With the recent development of less-costly uncooled detector technology, expensive optics are among the remaining significant cost drivers in the thermography camera. As a potential solution to this problem, the fabrication of IR lenses using chalcogenide glass has been studied in recent years. We report on the molding and evaluation of a ultra-precision chalcogenide-glass lens for the thermography camera for body-temperature monitoring. In addition, we fabricated prototype thermography camera using the chalcogenide-glass lens and obtained the thermal image from the camera. In this work, it was found out that thermography camera discerned body-temperature between 20 and $50^{\circ}C$ through the analysis of thermal image. It is confirmed that thermography camera using the chalcogenide-glass lens is applicable to the body-temperature monitoring system.