송전철탑의 풍응답 감소를 위한 마찰형 보강기구의 에너지 소산특성 분석 실험 (Experimental Investigation on the Energy Dissipation of Friction-type Reinforcing Members Installed in a Transmission Tower for Wind Response Reduction)

  • 박지훈;문병욱;이성경;민경원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.568-577
    • /
    • 2007
  • Friction-type reinforcing members (FRM) to enhance the resistance to wind loads of a transmission tower through both stiffness strengthening and damping increase are energy dissipation devices that utilize bending deflection of a tower leg. In this paper, the hysteretic behavior of the transmission tower structure with FRMs was experimentally investigated through cyclic loading tests on a half scale substructure model. Firstly, the variation of friction forces and durability of the FRM depending on the type of Friction-inducing materials used in the FRM were examined by performing the cyclic loading tests on the FRM. Secondly, Cyclic loading tests of a half-scale two-dimensional substructure model of a transmission tower with FRMs were conducted. Test results show that the FRM, of which desired maximum friction force is easily regulated by adjusting the amplitude of the torque applied to the bolts, have stable hysteretic behaviors and it is found that there exists the optimum torque depending on a design load by investigating the amount of energy dissipation of the FRMs according to the increase of torque.

  • PDF

500kV 가공 직류시험선로 설계 및 구축 (Design and Installation of Full Scale 500kV HVDC Test Line)

  • 신구용;임재섭;이원교;이동일;황갑철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.28-30
    • /
    • 2008
  • 본 논문은 국내 실정에 적합한 초고압 가공 직류 송전(HVDC)선로 설계를 위해서 세계적으로 처음 시도되는 가변 기능을 지닌 Proto Type HVDC 실규모 시험선로의 설계와 구축에 대해 소개한다. 시험선로는 초고압 직류송전시 발생하는 이온의 흐름에 의한 이온전류 밀도, 대전 전압, 지표면 전계강도 등 이온류(Ion류(流))에 의한 전기환경장애 및 코로나 영향을 검토하여 환경 친화적 HVDC 송전선로 설계기준을 도출하는데 있다. 이에 따라 HVDC 실규모 시험선로는 요크, 특수 애자련, 특수 arm을 사용하여 철탑의 극간 배치, 도체 배치 변경 및 지상고 변경이 가능하도록 winch를 채용하여 절연설계 조건의 유동성, 환경, 지지물, 송전기자재, 경제성 및 운용의 효율성을 종합적으로 고려할 수 있도록 특수한 형태로 설계되었으며, 본 논문은 상용 가공 HVDC 송전방식의 적용에 앞서 현재의 상황을 고려한 가공 HVDC 실증시험을 수행하기 위한 시험선로의 설계 및 구축에 대하여 기술하였다.

  • PDF

강관주 철탑기초의 수평거동에 관한 실험적 연구 (Experimental Study on the Laterally Loaded Behavior of Single Pole Foundation)

  • 김대홍;김경열
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1087-1094
    • /
    • 2008
  • The drilled pier foundation is widely used to support transmission line structures due to its simplicity of construction. When this foundation type is used in conjunction with a single shaft or H-frame structure, it is subjected to a high overturning moment, combined with modest vertical and shear loads. Since the length and diameter of drilled piers are often governed by a maximum permissible deflection, many drilled piers being installed today are very conservatively designed. In this study, Five prototype field-tests (1/8 scale) have been conducted in order to determine the lateral resistance of drilled pier foundation for single pole structures. These test results reveal the test piers behaved essentially as rigid bodies in soil (6D) and the center of rotation of the pier were typically 0.6~0.4 of the pier depth below ground surface. Test results also show the relationship between the applied load and the deflection at the top of the pier is highly nonlinear.

  • PDF

발전소로부터 방해물이 없는 주변지역에 대한 소음영향 및 대책 (Noise influence and Measures of Noise Sources of Thermal Power Sites on Neighborhood Residence Area located in Wide Flatland)

  • 김연환;배춘희;김계연;엄희문
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.630-636
    • /
    • 2008
  • 1000MW급 증설과 관련하여 발전소 주변지역으로부터 민원이 제기된 3000MW급 화력발전소는 넓은 평지에 위치하여 발전소의 영향이 그대로 주변지역에 전달되는 상태임에도 일상 소음레벨이 환경 기준치를 만족하는 상태였으나 향후 증설에 따른 소음도 증가에 대비하여 소음영향을 예측하고 저감 대책을 검토하였다. 대형 화력발전소의 옥외소음원은 Booster fan, I.D.fan, 주변압기, 대형 철탑, 해수순환수 펌프 전동기, 증기방출관 등이 있다. 대상 주거지역의 경우는 대형팬에 의한 지향성이 크게 나타났다. 따라서, 발전소가 주변지역에 주는 소음별 기여도를 평가하고 영향이 큰 대형팬에 대한 대책으로써 기기주변에 방음벽을 설치하는 방안과 함께 소음원의 크기를 저감시킬 수 있는 소음기 대책을 추천하여 증설 예정호기를 비롯한 기존 호기중 주거지역에 영향이 큰 3000MW에 대하여 수립함으로써 소음저감 목표치를 달성하는 결과를 도출하였다.

  • PDF

765kV 수직2회선 6도체 현수형 철탑에서 직접활선작업의 안전성 평가분석 (Analysis of Electrical Safety Level Test for Barehand Work at 765kV Vertical Double Circuit Six Bundle Conductors on the Suspension String Tower Type)

  • 김대식;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.275-278
    • /
    • 2008
  • It has been issued that the necessity of Live line work for 765kV vertical double circuit six bundle conductors transmission line when the characteristics of transmission line, the composition of T/L and near the T/L circumstances etc. Others are considered. The Barehand method of UHV T/L is extremely dangerous work and especially it is directly related with lineman life so it is very dangerous. It should be performed several technology developments for live-line work on the UHV T/L, that should be considered such as the electrical influence on workers near the T/L, development of live-line facilities, guarantee of safety, the technical rules of live-line work, the safe method of live-line work and etc. In order to maintain the 765kV transmission lines safely by barehand work, first of all, we should know the analysis of electrical safety level test in live-line work at 765kV vertical double circuit six bundle conductors on the suspension string tower type.

송전선로 지락시 철탑 인근의 대지전위간섭 해석모델 (Analysis of Conductive Interference nearby High Voltage Power Lines under Fault Condition)

  • 최종기;이원교;유희영;신복현;손광목;김태영;황갑철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.466-467
    • /
    • 2008
  • In case of a line-to-ground fault at transmission lines, a portion of fault current will flow into the earth through the footings of the faulted tower causing electrical potential rise nearby the faulted tower footings. In this situation, any buried pipelines or structures nearby the faulted tower can be exposed to the electrical stress by earth potential rise. Although many research works has been conducted on this phenomena, there has been no clear answer of the required separation distance between tower footings and neary buried pipeline because of its dependancy on the soil electrical charactersics of the concerned area and the faulted system.

  • PDF

${\pm}500kV$ 가공직류 시험선로 구축 및 전기환경 실증연구 (Study on the Installation of Full Scale ${\pm}500kV$ HVDC Test Line)

  • 이원교;신구용;임재섭;이동일;황갑철;최진성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.458-459
    • /
    • 2008
  • 본 논문은 폭넓은 전기환경 실증연구가 가능한 실규모 HVDC 시험선로의 설계 및 구축에 대해 소개한다. 국내 실정에 적합한 초고압 가공 직류송전(HVDC)선로 설계를 위해서는 전기적인 환경 장애를 일으키지 않는 환경친화적인 설계 및 건설에 대한 대안이 마련되어야 한다. HVDC 선로의 전기적인 환경영향은 주로 (+)극과 (-)극에서 발생하는 이온의 흐름에 의한 이온전류 밀도, 대전전압, 지표면전계강도 등 이온류(Ion流)의 영향과 초고압 송전에 따른 코로나 영향에 대해 검토하는 것이다. HVDC 실규모 시험선로는 요크, 특수 애자련, 특수 arm을 사용하여 철탑의 극간 배치, 도체 배치 변경 및 지상고 변경이 가능하도록 winch를 채용하여 절연설계 조건의 유동성, 환경, 지지물, 송전기자재, 경제성 및 운용의 효율성을 종합적으로 고려할 수 있도록 특수한 형태로 설계하여 각종 전기환경 실증연구가 가능하며 국내 환경 특성에 적합한 최적 극배치 좌표 도출이 가능하도록 구축되었다. 본 논문은 상용 가공 HVDC 송전방식의 적용에 앞서 현재의 상황을 고려한 전기환경 실증 연구가 가능한 실규모 HVDC 시험선로의 설계 및 구축에 대하여 기술하였다.

  • PDF

운전 중인 송전선로의 철탑 전위강하시험과 해석 (Test and Analysis of Fall-Of-Potential at Towers of Energized Transmission Lines)

  • 강연욱;이동일;심응보;김경철;최종기
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권5호
    • /
    • pp.195-201
    • /
    • 2006
  • Tower footing resistance and fault current division factor are important design factors for evaluation of the lightning performance of the transmission line and/or design of the grounding electrode system. The periodic measurement of those factors are also important to verify that the grounding performance of the towers has been maintained good. However, the direct measurement of those factors in operating or energized condition is very difficult because of many practical reasons, such as the difficulty of disconnecting overhead groundwires from the tower under test. With supports by GECOL (General Electricitiy Company of Libya), we had a special chance to conduct Fall-Of-Potential (FOP) test on the energized 220 kV transmission towers before and after disconnecting the overhead groundwires from the towers under test. In this paper, the FOP test results on the towers and the fault current division factors estimated from the comparision of the FOP tests with and without overhead groundwires were presented. The computer models for the FOP test simulations were also constructed to find that the simulated results agreed very well with the measured ones.

송전용 풍하중 설계기준 합리화를 위한 기술검토 (Study on the Design Standard for the Wind Resistant on Transmission Tower)

  • 신구용;이동일;신태우;최진성;방항권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.652-654
    • /
    • 2007
  • 본 논문에서는 국가의 기간 에너지원인 전력망을 구성하는 구조물인 송전철탑의 설계하중에 가장 큰 요인으로 작용하는 기준풍속 산정을 위한 연구내용을 고찰하고자 한다. 현행의 송전용 지지물 설계 기준은 전기설비기술기준에 고시된 가공전선로 지지물에 관한 기준을 토대로 전력사의 실무적인 설계를 위하여 보다 구체화하여 작성된 한국전력공사 송전설계기준에 근거하고 있다. 이러한 기존 설계기준은 1985년 이전의 기상자료를 토대로 제정되어 본 논문에서는 1980년대 후반부터 약 20년간의 기상청의 풍향, 풍속자료를 추가로 확보하고 이를 분석하여 재현기간을 반영한 지역별 설계기준 풍속 Map을 제시하였다. 이러한 흐름으로 최근의 기상자료를 포함하여 보다 정확한 분석을 도모하고, 사회 환경의 급변함에 따라 우려되는 기상이변 등을 고려한 안전성과 경제성이 향상된 기준풍속 산정과정을 고찰하고, IEC 등 해외 주요국의 풍하중 설계기준에서 반영하고 있는 국부지형을 고려한 설계방법에 대한 국내 기준 적용성 평가를 위한 비교분석 결과를 소개하였다.

  • PDF

가공송전철탑 경량화 설계에 관한 연구 (A Study of the Slim Design of Overhead Transmission Tower)

  • 이정원;이원교
    • 한국전기전자재료학회논문지
    • /
    • 제23권7호
    • /
    • pp.560-565
    • /
    • 2010
  • This paper presents the design factor of an overhead transmission tower structure in order to reduce the tower weight. The behaviour of transmission tower structures are affected by the horizontal angle of the tower structure, the equivalent wind pressure group, the slope of the main post of the tower, the separation of the internode and the use of high-strength materials in their construction. Tower weight can be reduced by approximately 30% reduce weight by means of optimal design based on a consideration of all the above factors. In addition, the design of the foundation of the tower with the shear key installation to increase horizontal support together with a modified angle of inclination to the ground can reduce by about 37% the amount of concrete used during construction. The area of ground disturbed by the construction of the tower foundation can thus be reduced by approximately 33%. Therefore it is possible to build an environmently-friendly T/L tower with the mechanical properties of existing towers.