• Title/Summary/Keyword: 철도기록

Search Result 53, Processing Time 0.025 seconds

Evaluation of Peak Ground Acceleration Based on Seismic Design Standards in Sejong City Area Using Gyeongju-Pohang Type Design Seismic Waves (경주·포항형 설계지진파를 활용한 세종시 지역의 내진설계기준 지표면최대가속도 성능평가)

  • Oh, Hyun Ju;Lee, Sung Hyun;Park, Hyung Choon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.41-48
    • /
    • 2024
  • In 2017, the Ministry of the Interior and Safety conducted research for the revision of seismic design standards and performed studies on standard design response spectra. As a result, the Common Application Guidelines for Seismic Design Standards were introduced, and these guidelines have been implemented in the national design standards of the Ministry of Land, Infrastructure, and Transport for practical use. However, it should be noted that the research for proposing standard design response spectra during the 2017 revision was conducted before the occurrence of the significant seismic events in South Korea, such as the 2016 Gyeongju Earthquake and the 2017 Pohang Earthquake. To account for these recent major earthquakes, this study adjusted the standard design spectra based on the records of the 2016 Gyeongju Earthquake and the 2017 Pohang Earthquake and conducted ground response analyses accordingly. The results revealed variations in peak ground acceleration (PGA) at the ground surface even within the same ground classification. It was confirmed that this variation can lead to overestimation or underestimation of seismic loads.

Implementation of Indoor Air Quality Monitoring System for Subway Stations (지하철 역사 공기질 모니터링 시스템의 구현)

  • Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.294-301
    • /
    • 2013
  • The particle matter concentrations in the subway stations should be monitored and controlled for the health of commuters on the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. In this paper, the reliability of the cheap instruments using light scattering method is improved with the help of a linear regression analysis technique to measure the $PM_{10}$ concentrations continuously in the subway stations. In addition, a monitoring system is implemented to display and record the data of $PM_{10}$, $CO_2$, humidity, and temperature. To transmit and receive these measured sensor data, CDMA M2M wireless communication method is applied.

Effects of Earthquake on Tunnel Stability (지진이 터널 안정에 미치는 영향)

  • 박남서
    • Explosives and Blasting
    • /
    • v.14 no.2
    • /
    • pp.71-80
    • /
    • 1996
  • A series of nurmerical analysse for the earhtquake of Iran railway tunnles under construction by NATM(New Astrian Tunnelling Method) were careid out throuth a pseudo-dynamic analyses techique used in a FFM computer program, DWTAP(Daewoo Tunnel Analysis Program), and the results are described in the paper. The analyses were performErl for two case;one is for the primary supports and the other is for the rompletEd permanent roncrete lining. The horizontal and verical groW1d accelerations for the design were estimatEd as 0.34 g and 0.23 g, respectively based on the historical reismic rerords in the proj3et area and the empirical equations. The results show that the turmel would be safe W1der the anticipitOO earthquake motion with the permanent roncrete lining, but some minor cracks rnigt be developErl in the primary shotcrete lining without any significant structural damages.

  • PDF

A Study on the Transitions and Site of temporary palace(Onyanghaenggung) according to the <Oncheonhaenggungdo>(1795) (<온천행궁도(溫泉行宮圖)>(1795)의 온양행궁지 추정 및 온양행궁 변천 고찰)

  • LEE Jeongsoo;KIM Ilhwan;LEE Kyeongmi;JI Wonku;CHOI Jaeseong
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.4
    • /
    • pp.94-108
    • /
    • 2023
  • Onyanghaenggung Palace(temporary palace at Onyang) is an important cultural heritage that can substantially confirm the king's onhaeng(溫行) base on literature records such as <Ongungyeonggoedae(溫宮靈槐臺)>, <Oncheonhaenggungdo(溫泉行宮圖)> of 『Ongungsasil(溫宮事實)』『, Younggoedaegi(靈槐臺記)』and cultural property such as Yeonggoedae(靈槐臺) and Shinjeong Monument(神井碑). As the Onyang Tourist Hotel is located in the presumed site of the Onyanghaenggung Palace, even the identity of the Onyanghaenggung Palace site is being threatened without restoration efforts. The purpose of this study is to estimate the location of Onyanghaenggung Palace based on <Oncheonhaenggungdo> before the damages during the Japanese colonial period. To achieve these purposes, records related to Onhaeng during successive kings' terms in the Joseon Dynasty are first reviewed, before changes in the architecture of Onyanghaenggung Palace that took place in the Joseon Dynasty and damage suffered during the Japanese colonial period are summarized, and finally <Oncheonhaenggungdo>, <Eupji>, <Ancient Maps>, <Jijeokwondo> are reviewed. Based on these processes, the location of Onyanghaenggung Palace is estimated by comparing the current Onyang Tourist Hotel and the surrounding area. The results of this study are as follows. First, if the 1,758 cheok(尺) of 「Onyanggun eupji」 and 「Hoseo eupji」 are converted in Jucheok(周尺), the scope of Onyanghaenggung Palace is close to the inner circumference of the site(垈) in Jijeokwondo(1914). Second, the streamlet leading to Oncheoncheon(溫泉川) from the southern side of Onyanggwan(溫陽館), the hot spring hole in use of <Distribution Map of Hot Spring(溫泉分布見取圖)>(1925, 1928), and considering the relationship of the inner east gate(內東門), Bigak(碑閣), Sinjeong(神井) of <Oncheonhaenggungdo>, the building of Hermann Gustav Theodor Sander and the Copyright Commission's Onyang Hot Springs photograph can be estimated as the Onyanghaenggung Palace Hot-spring, namely Tangsil(湯室). Third, in the process of developing to amusement park, the transfer and relocation of the Yeonggaedae site(a governmentowned property) was requested by Gyeongnam Railway Company, but Chungcheongnam-do denied transfer and relocation of the Yeonggaedae because of the importance in the history of Onyang Hot Springs, so the government-owned Yeonggaedae Monument site were permanently preserved at the current location together with the hoe tree(Sophora japonica L.). Also, Yeonggoedae in <Tourists Attractions around Gyeongnam Railway in Joseon (朝鮮京南鐵道沿線名所交通図絵)> (1929) is shown to exist in its current location, and it can be seen that the Shinjeong Monument Pavilion was moved to the front of Shinjeonggwan (神井館). Based on the circumference of Onyanghaenggung Palace, the location of Onyanghaenggung Palace Hot Spring (Tangsil) and Yeonggaedae Monument Pavilion, changes in roads and lots of land during the Japanese colonial period and the modern period, as well as the location of Onyanghaenggung Palace and other major buildings, can be estimated to extend to the current Shimin-ro and Onyang Hot Spring Market.

An Analysis on the Geomagnetic Transfer Function at Yongin Observatory Using by RR (Remote Reference) and SNS (Signal Noise Separation) Technique (원격참조(RR: Remote Reference) 기법과 신호잡음분리(SNS: Signal Noise Separation)기술을 이용한 용인 관측소의 지자기 전달함수 분석)

  • Yang Junmo;Lee Duk-Kee;Kwon Byung-Doo;Ryu Yong-Gyu;Youn Yong-Hoon
    • Economic and Environmental Geology
    • /
    • v.38 no.2 s.171
    • /
    • pp.155-163
    • /
    • 2005
  • For an unbiased TF (Tansfer Function) estimations we investigate geomagnetic TF derived from ICHEON and YONGIN sites, employing RR (Remote Reference) and SNS (Signal Noise Separation) techniques. The Rh technique, which requires synchronized field variations recorded at a clean remote site, is a reliable method to minimize the bias of TF by uncorrelated noises in magnetic channels. Meanwhile, SNS technique based on the assumption of noise-free remote data can improve the signal-noise level by separating signal TF and noise TF, which is successfully applied to the environments with strong correlated noises. In this study, TF at YONGIN is analyzed using geomagnetic data from ICHEON site as a remote reference, which seem to have somewhat better data quality. The application of Rh technique reduces the bias of TF, which appears in single site robust estimation, and makes curves in the amplitude and phase of TF more smooth as frequency. Futhermore, in order to investigate noise source quantitatively, SNS technique is applied. The results of SNS suggest that dominant noise source seems to be located at western region of YONGIN. This noise source is considered to originate from railway system such as KTX and national subway. which passes through the west regions of YONGIN.

Application of linear array microtremor survey for rock mass classification in urban tunnel design (도심지 터널 암반분류를 위한 선형배열 상시진동 탄성파탐사 적용)

  • Cha Young Ho;Kang Jong Suk;Jo Churl Hyun;Lee Kun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.157-164
    • /
    • 2005
  • Urban conditions such as underground facilities and ambient noises due to cultural activity restrict the application of conventional geophysical techniques in general. We used the refraction microtremor (REMI) technique as an alternative way to get the geotechnical information, in particular shear-wave (S-wave) velocity information, at a site along an existing rail road. The REMI method uses ambient noises recorded using standard refraction equipment to derived shear-wave velocity information at a site. It does a wavefield transformation on the recorded wavefield to produce Rayleigh wave dispersion curve, which are then picked and modeled to get the shear-wave velocity structure. At this site the vibrations from the running trains provided strong noise sources that allowed REMI to be very effective. REMI was performed along the planned new underground rail tunnel. In addition, Suspension PS logging (SPS) were carried out at selected boreholes along the profile in order to draw out the quantitative relation between the shear wave velocity from the PS logging and the rock mass rating (RMR) determined from the inspection of the cores recovered from the same boreholes, These correlations were then used to relate the shear-wave velocity derived from REMI to RMR along the entire profile. The correlation between shear wave velocity and RMR was very good and so it was possible to estimate the RMR of the total zone of interest for the design of underground tunnel,

  • PDF

Development of Evaluation System for the Cognitive Performance of Marine Officers (항해사 인지능력 평가시스템)

  • Kim, Hong-Tae;Hong, Seoung-Kwon;Barnett, Mike
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.650-653
    • /
    • 2009
  • Decrease in crew performance is frequently cited as a major causal factor in maritime accidents. Although considerable researches on working hours undertaken by seafarers have been conducted through interviews and record analyses, experimental studies on the effects of factors, such as high workload, shift patterns, stress, sleep deprivation, and disturbance on the cognitive performance of mariners have been limited. Other safety-critical transport industries, such as aviation and rail, have developed fatigue management tools to help managements in the work patterns of their operators. Such tools for mariners would assist shipboard crews, marine pilots, and shore managers for planning and improving work schedules. The overall aim of this paper is to determine a fatigue factor that can be applied to human performance data as a part of a software program that calculates total cognitive performance. This program enables us to establish the levels of cognitive performance in a group of marine pilots in order to test a decision-making task based on radar information. This paper addresses one of the factors that may contribute to the determination of various fatigue factors: the effects of different work patterns on the cognitive performance of a marine pilot.

  • PDF

Environmental Sensor Monitoring System of Subway Stations Using USN (USN을 이용한 지하철 역사 대기환경 모니터링 시스템)

  • Oh, Joon-Tae;Kim, Gyu-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • The$PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. In this paper, the reliability of the instruments using light scattering method is improved with the help of a linear regression analysis technique to measure the $PM_{10}$ concentrations continuously in the subway stations. In addition, an USN monitoring system is implemented to display and record the data of $PM_{10}$, CO/$CO_2$, humidity, and temperature. To transmit and receive these measured sensor data, 2.4GHz Zigbee, 424MHz wireless communication, and CDMA M2M method are applied and evaluated.

The Service Voltage Measurement and Analysis while TTX Runs (틸팅열차 운행 중 가선전압 계측 및 분석연구)

  • Lee, Su-Gil;Kang, Chul;Her, Jae-Sern;Kim, Jae-Chul;Lim, Jae-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.58-65
    • /
    • 2009
  • Recently, the Korea Tilting Express(TTX), "HANVIT 200", KRRI(Korea Railroad Research Institute) developed runs for test on the conventional railroad, Honam line, Center line, Chunk-buk line and Tae-baek line. In this paper, we measured the service voltage while TTX ran on the conventional railroad and analyzed the condition of voltage. For measuring voltage directly, we installed PT under the pantograph and measured the voltage of the primary winding. In addition, we record situations that other trains pass by TTX and environments while TTX ran. And then we analyzed the condition of voltage using the records and CBEMA curve. In result, over 110[%] voltage of rated voltage(25[kV]) often occurred and the voltage of some place continued over 110[%] for about 200[s]. Especially, the voltage condition of Tae-baek line is the worst. The results in this paper can help to stabilize the power device and power converter of TTX.

Seismic Fragility Evaluation of Cut-and-cover Tunnel (박스형 터널의 지진 취약도 평가)

  • Park, Duhee;Nguyen, Duy-Duan;Lee, Tae-Hyung;Nguyen, Van-Quang
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.11
    • /
    • pp.71-80
    • /
    • 2018
  • In this study, the seismic response of cut-and-cover box tunnels is evaluated from pseudo-static analyses and the fragility curves are derived. A series of site profiles were used to evaluate the effect of soil conditions. A total of 20 ground motions were used. The fragility curves were developed as functions of peak ground acceleration for three damage states, which are minor, moderate, and extensive states. The damage indices, defined as the ratio of the elastic moment to the yield moment, correlated to three damage states, were used. The curves are shown to greatly depend on the site profile. The curves are further compared to those derived in previous studies. The widely used empirically derived curves are shown not to account for the site effects, and therefore underestimate the response for soft sites.