Experimental Study on Lap Splice of Headed Deformed Reinforcing Bars in Tension (인장력을 받는 확대머리 이형철근의 겹침이음에 관한 실험적 연구)

  • Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.59-67
    • /
    • 2014
  • In tension lap splices of straight deformed bars, KCI Code (KCI2012) and ACI Code (ACI318-11) requires that the lap lengths for class B splice are 1.3 times as development length. KCI2012 contains development length provisions for the use of headed deformed bars in tension and does not allow their tension lap splices. The purpose of this experimental study is to evaluate that KCI2012 equation for the development length, $l_{dt}$, of headed bars can be used to calculate the lap length, $l_s$, of headed deformed bars in grade SD400 and SD500, having specified yield strength of 400 and 500 MPa. Test results showed that specimens with $l_s$ equal to $1.3l_{dt}$ had maximum flexural strengths as 1.16~1.31 times as the nominal flexural strengths, flexural failure mode, and ductility. These observations indicate that $1.3l_{dt}$ is suitable to the tensile lap length of headed deformed bars in grade SD400 and SD500.

Development Length Effects of High Strength Headed Bar (고강도 확대머리 이형철근의 정착길이 효과에 관한 실험적 연구)

  • Moon, Jeong-Ho;Oh, Young-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.75-82
    • /
    • 2015
  • An experimental study has been carried out to examine development length effects for high strength headed deformed bars. Current design codes limit the specified yield strength of headed bars to 400 MPa. Such the limit is due to the lack of experimental studies on headed bars made of high strength materials. Thus a test program was planed with headed bars with the yield strength of 600 MPa. The threaded head type with head shapes of round plate and circular cone was selected in this study. The experimental variables were development length, number of bars, and head shape. Specimens were classified into L-type and S-type depending on the development length. The development length of L-type was computed according to the design code without considering the limit. S-type specimens had shorter development lengths than the L-type. Further classification was made depending on the shape of heads. A-types have the head shape of round plate and B-types have the shape of circular cone. Three L-type specimens were fabricated with the variable of number of bars (1, 2, and 3). Four specimens for each of SA and SB types were made with development lengths of 50%, 45%, 40%, and 35% compared with L-type. Pullout tests was carried out with 11 specimens. The test results were compared with computed strengths with the design code equations (Appendix II). Based the current studies, it can be said that high strength headed deformed bars used in this study be able to provide such strengths computed with the current design code without considering the yield strength limit.

Influence of ductility of reinforcement on the plastic hinge formation (철근의 연성이 소성힌지 생성에 미치는 영향)

  • Park, Dae-Gyun;Cho, Jae-Yeol;Park, Sung-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.97-100
    • /
    • 2008
  • Subjected to seismic action causing large deformation of bridge columns, the plastic hinge region is commonly formed in the column end zone. The deformation capacity of a concrete column can be expressed by using plastic hinge length. The mechanical properties of high-strength reinforcing steel is different from that of normal-strength steel and the mechanical properties of steel will influence the plastic hinge formation. Therefore, in other to accurately predict the deformation of concrete column using high-strength steel, the plastic hinge length can be expressed as a function of the mechanical properties of steel such as the tensile to yield strength ratio and the strain at ultimate state. However, little research has been conducted into the effect of mechanical properties of steel on the plastic hinge length. It was difficult to measure the plastic hinge length from the test results. Therefore, the plastic hinge length of concrete columns was investigated from the curvature profile. A numerical approach was used to study the effect of various parameters on plastic hinge length. Based on the results of the numerical parametric study, a new expression for plastic hinge length was proposed.

  • PDF

The Study on Development of Automatic Main Reinforcement Placing System of Columns for RC Structures based on Parametric Technology (파라메트릭 기술기반 철근콘크리트 구조물의 기둥부재 주철근 자동배근시스템 구축에 관한 연구)

  • Cho, Young-Sang;Hong, Seong-Uk;Kim, Yu-Ri;Lee, Je-Hyuk
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.484-487
    • /
    • 2010
  • 본 논문에서는 BIM(Building Information Modeling)의 핵심기술인 파라메트릭 기술을 기반으로 하여 철근콘크리트 구조물의 기둥부재 주철근 자동배근시스템을 구축함으로써 기존 프로그램에서 사용자가 직접 입력해야하는 변수의 수를 최소화하고 사용성과 정확성을 높이는 것을 목적으로 한다. 기존 철근배근 형상 자동 모델링에서 기둥철근의 자동 모델링은 기둥단면이 변하는 부분에서의 철근 배근과 정착 및 이음길이를 고려하지 않고 있다. 만약 고려하더라도 이용자가 직접 입력하는 방식이기 때문에 규모가 큰 건물일 경우 방대한 정보의 처리 미숙으로 인해 정확한 모델링을 기대하기 어려운 실정이다. 본 연구에서는 기둥 부재에 대하여 대상 건물을 선정하고 구조해석 모델링을 구축한 후 구조해석 결과 데이터베이스를 추출하여 얻은 정보와 건축구조설계기준에 따른 정착 및 이음 길이 산정에 관한 알고리즘을 구축하여 철근배근 형상 자동화 모듈에 적용하여 배근 자동 설계 및 자동 형상화 모듈을 생성하였다.

  • PDF

An Evaluation of Lap Splice Length of Epoxy Coated Reinforcements Using Beam-End Test (보-단부 시험을 이용한 에폭시 도막 철근의 겹침 이음길이 평가)

  • Kim, Jee-Sang;Kang, Won Hyeak
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.2
    • /
    • pp.175-182
    • /
    • 2020
  • The application of epoxy coated reinforcements is increased as a means to prevent a corrosion of reinforcements embedded in reinforced concrete structures, However, epoxy coating may reduce the bond capacity between concrete and reinforcement, which results a longer development length and lap splice length. This paper aims to the possibility of modification in lap splice length from reduction of basic development length which was confirmed using a direct pull out test. Total 36 beam specimens were tested to compare the lap splice properties of normal and epoxy coated reinforcements with beam-end test for various lap lengths and diameters of reinforcements. According to the results on failure modes, deformations, and crack widths of this experiments, the modification factor of 1.2 should be used, though the direct bond capacity is assured through direct pull out test.

Evaluation of Plastic Rotational Capacity Based on Material Characteristics in Reinforced Concrete Flexural Members (재료 특성에 기반한 철근콘크리트 휨부재의 소성회전능력 산정)

  • Choi, Seung-Won;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.825-832
    • /
    • 2010
  • Although a critical section reaches its flexural strength in reinforced concrete structures, the structure does not always fail because moment redistribution occurs during the formation of plastic hinges. Inelastic deformation in a plastic hinge region results in plastic rotation. A plastic hinge mainly depends on material characteristics. In this study, a plastic hinge length and plastic rotation are evaluated using the flexural curvature distribution which is derived from the material models given in Eurocode 2. The influence on plastic capacity the limit values of the material model used, that is, ultimate strain of concrete and steel and hardening ratio of steel(k), are investigated. As results, it is appeared that a large ultimate strain of concrete and steel is resulting in large plastic capactiy and also as a hardening ratio of steel increases, the plastic rotation increases significantly. Therefore, a careful attention would be paid to determine the limit values of material characteristics in the RC structures.

Bond Strength of Grout-Filled Splice Sleeve Considering Effects of Confinement (구속효과를 고려한 모르타르 충전식 철근이음의 부착강도)

  • Kim, Hyong-Kee;Ahn, Byung-Ik
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.615-622
    • /
    • 2003
  • The purpose of this study is to propose the more reasonable equation of bond strength of grout-filled splice sleeve. To accomplish this objective, total 60 full-sized specimens were tested under monotonic loading. The experimental variables are compressive strength of mortar, embedment length and size of reinforcing bars. Following conclusions are obtained; 1) If the adequacy of existing equations which estimate the bond strength of grout-filled splice sleeve are investigated, they underestimate the bond strength of grout-filled splice sleeve by 8-18%. Also the existing equations have a tendency to underestimate with decrease in the embedment length of reinforcing bars. 2) From the test result of bond failure, the equation which estimates the confining pressure of grout-filled splice sleeve was proposed by making multiple regression analyses of which independent variables are embedment length of reinforcing bars and compressive strength of mortar. This equation predicted the measured bond capacity of this test more accurately than existing equations and eliminated the deviation according to the embedment length of reinforcing bars.

An evaluation of compressive lap splice of the D22 rebar by concrete strengths (콘크리트 강도변화에 따른 D22mm 철근의 압축이음 성능 평가)

  • Lee, Sung-Ho;Chun, Sung-Chul;Oh, Bo-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1081-1084
    • /
    • 2008
  • Column specimens were constructed with main parameters significantly affecting the strength of the compression lap splice, such as lap length, spacing of lapped bars, amount and location of transverse reinforcements, and concrete strength. An experimental study has been conducted with column specimens in concrete strength of 40 to 60 MPa. Diameters of lapped reinforcing bars are 22 mm. An axial load was monotonically applied to the column specimens. All specimens failed in a brittle sudden manner and cover concrete was blasted out at maximum load. Compression lap splice strengths of specimens were evaluated from strains measured at the beginning of the lap length. Effects of the main parameters on the strengths of compression lap splice are assessed. Similarly to strengths of tension lap slice, the compression splice strength is found to be affected by lap length, spacing of lapped bars, transverse reinforcements.

  • PDF

Failure Mechanism and Ultimate Strength of Headed Bar Anchored in Deep Beam Using Truss Models (트러스 모델을 이용한 춤이 깊은 보에 정착된 헤드 철근의 파괴 메커니즘과 극한 내력 해석)

  • Cheon, Sung-Chul;Hong, Sung-Gul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.143-146
    • /
    • 2005
  • 최근 들어 90도 표준갈고리의 대안으로 정착판을 지니는 헤드 철근(headed bar)에 대한 관심이 높아지고 있다. 헤드 철근의 정착내력은, 정착판의 지압력과 위험단면에서 헤드까지 정착길이의 부착력으로 발현된다. 실제 구조물에서는 정착되는 부재의 재료 및 기하학적 물성에 의해 다양한 파괴가 발생된다. 따라서 헤드 철근의 정착내력은 단순히 지압력과 부착력의 합으로 산정될 수 없으며, 발생 가능한 모든 파괴양상을 고려한 최소 내력으로 결정되어야 한다. 헤드 철근의 정착내력을 산정하기 위한 기본적인 해석모델로, CCT 절점에 정착된 헤드 철근의 트러스 모델을 제안하였다. 제안된 트러스 모델의 파괴는 부착파괴와 콘크리트의 압축파괴로 구분되며, 재료 및 기하학적 물성에 의해 파괴 양상이 결정된다. 이러한 트러스 모델은 외부 보-기둥 접합부와 같이 보다 복잡한 부위에 정착된 헤드철근의 정착 기구를 설명하는데 활용될 수 있다.

  • PDF

Analysis of Correlativity with the Number of Blasting Holes Due to Exposed Length of Steel Bars and Vertical Load on Scaled Reinforced Concrete Columns (축소모형 철근콘크리트 기둥에서 철근의 노출길이와 수직하중에 따른 발파공수와의 상관성 분석)

  • Park, Hoon;Yoo, Ji-Wan;Lee, Hee-Gwang;Song, Jung-Un;Kim, Sung-Kon
    • Explosives and Blasting
    • /
    • v.25 no.2
    • /
    • pp.1-10
    • /
    • 2007
  • In this paper, the 1/5 scale models of the reinforced concrete colunms were designed and fabricated. The influence of the number of blasting holes on the exposed length of steel bars and vertical load was investigated. The relation between the length of steel bar and the number of blasting holes was examined by performing the blast tests considering the vertical load on the scaled reinforced concrete columns. Weight of scaled column models by blasting and that of exposed was compared with the number of blasting holes. Finally, based on the exposed length of steel bars and vertical load, the number of blasting holes were calculated. Results shows that the number of blasting holes calculated in this study are suitable for scaled structure models test by blasting demolition.