• Title/Summary/Keyword: 철근콘크리트 교각

Search Result 247, Processing Time 0.022 seconds

Structrral Analysis of Bridge Pier with 40MPa High Strength Concrete (설계강도 40MPa 고강도 콘크리트를 적용한 교량 교각 구조물의 구조해석)

  • Hur, Jae-Hun;Yi, Sang-Keun;Gwak, Seok-Hwan;Huh, Suk-Bum;Park, Chang-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.157-158
    • /
    • 2009
  • In this study, We analyze structural behavior feature of column under reinforced-bar and concrete strength and load conditions and analyze optimal column diameter and construction cost through parameter study. In case we use the 40MPa high strength concrete instead of 27MPa concrete in pier, the results show positive effect in appearance of pier and cost because of small column diameter and low construction cost. Also, practical effect is proved by applying this results in pier of Shin Hou Bridge on Hum-Sung ${\sim}$ Chung-Ju highway construction work.

  • PDF

Finite Element Analysis of RC Structures considering Bond Characteristics (부착특성을 고려한 RC구조물의 유한요소 해석)

  • 한상호
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.5
    • /
    • pp.157-164
    • /
    • 1997
  • 일반적으로 콘크리트와 철근간의 경계면을 나타내는 유한요소법에는 균열의 부근에서 발생하는 부착열화 현상을 고려하지 않고 있다. 이것은 균열 부근에서 과도한 부착을 초래하고 , 국소 변형과 균열의 진전에도 영향을 준다. 본 연구에서는 철근콘크리트 구조물의 균열부근에서 일어나는 부착거동의 변화를 고려한 비선형 부착응력-미끄럼 모델을 제안하였다. 철근과 콘크리트간의 경계면에는 링크요소를 이용하였고, 링크의 특성은 철근을 가로지르는 균열의 상태에 따라 변하도록 조정하였다. 균열의 형성상태를 정량화하고, 부착거동을 두 포락선 1) 균열로부터 충분히 떨어진 위치에서의 부착상태를 모델링한 외연포락선, 2)횡균열면에 있어서의 부착상태를 모델링한 내연포락선의 사이에 변이시키기 위하여 비국소적 손상도 개념을 도입하였다. 이 방법의 유효성을 알아보기 위하여 편재하중을 받는 T형 교각의 실험 및 해석결과를 제시하였다. 제안된 모델의 결과를 실험결과와 비교하여 본 모델의 유용성을 검증하였다.

Seismic Performance of Hollow Rectangular Precast Segmental Piers (프리캐스트 중공 사각형 철근콘크리트 교각의 내진성능)

  • Lee, Jae-Hoon;Park, Dong-Kyu;Choi, Jin-Ho;Shin, Sung-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.705-714
    • /
    • 2012
  • Precast reinforced concrete bridge columns with hollow rectangular section were tested under cyclic lateral load with constant axial force to investigate its seismic performance. After all the precast column segments were erected, longitudinal reinforcement was inserted in the sheath prefabricated in the segments, which were then mortar grouted. Main variables of the test series were column aspect ratio, longitudinal reinforcement ratio, amount of lateral reinforcement, and location of segment joints. The aspect ratios were 4.5 and 2.5, and the longitudinal steel ratios were 1.15% and 3.07%. The amount of lateral reinforcement were 95%, 55%, 50%, and 27% of the minimum amount for full ductility design requirements in the Korean Bridge Design Code. The locations of segment joints in plastic hinge region were 0.5 and 1.0 times of the section depth from the bottom column end. The test results of cracking and failure mode, axial-flexural strength, lateral load-displacement relationship, and displacement ductility are presented. Then, safety of the ductility demand based seismic design in the Korean Bridge Design Code is discussed. The column specimens showed larger ductility than expected, because buckling of longitudinal reinforcing bar was prevented due to confinement developed not only by transverse steel but also by sheath and infilling mortar.

The Evaluation of Seismic Performance for Concrete-filled Steel Piers (콘크리트 충전 강교각의 내진 성능 평가)

  • 정지만;장승필;인성빈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.5
    • /
    • pp.53-58
    • /
    • 2002
  • A recent development, a concrete-filled steel(CFS) pier is an alternative to a reinforced concrete bridge pier in an urban area, because of its fast construction and excellent ductility against earthquakes. The capacity of CFS piers has not been used to a practical design, because there is no guide of a seismic design for CFS piers. Therefore, the guide of a seismic design value is derived from tests of CFS piers in order to apply it to a practical seismic design. Steel piers and concrete-filled steel piers are tested with constant axial load using quasi-static cyclic lateral load to check ductile capacity and using the real Kobe ground motion of pseudo-dynamic test to verify seismic performance. The results prove that CFS piers have more satisfactory ductility and strength than steel piers and relatively large hysteretic damping in dynamic behaviors. The seismic performance of steel and CFS piers is quantified on the basis of the test results. These results are evaluated through comparison of both the response modification factor method by elastic response spectrum and the performance-based design method by capacity spectrum and demand spectrum using effective viscous damping. The response modification factor of CFS piers is presented to apply in seismic design on a basis of this evaluation for a seismic performance.

A Parameter Study of Internally Confined Hollow Reinforced Concrete Piers (내부 구속 중공 RC 교각의 매개변수 연구)

  • Choi, Jun-Ho;Yoon, Ki-Yong;Han, Taek-Hee;Kang, Young-Jong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.17-24
    • /
    • 2010
  • The hollow RC(Reinforced concrete) pier has the merit of lightweight pier compared with solid RC pier. However, the hollow RC pier shows a low ductile behavior due to brittle failure of inside concrete. To overcome this problem, the internally confined hollow reinforced concrete column has been developed. In this study, the behavior of internally confined hollow RC piers were evaluated with safety ratio, ductility, total material cost, the total weight of the pier, etc. The chosen parameters for the study are hollow ratio, thickness of internal steel tube, intervals between vertical re-bars, numbers of horizontal re-bars, and strength of concrete. As a result of parameters study, the usage of a minimum necessary thickness of the internal steel tube is the most effective.

Modified Equation for Ductility Demand Based Transverse Confining Reinforcement (요구연성도에 따른 횡방향 심부구속철근량 산정식 수정)

  • Son, Hyeok-Soo;Lee, Jae-Hoon;Suh, Suk-Koo;Oh, Myung-Seok;Yoon, Cheol-Kyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.7-8
    • /
    • 2009
  • In this research, comparison and analysis were performed to understand how the cover thickness influences the equation for calculating the amount of confining reinforcement for reinforced concrete columns. And, also, an equation for calculating the amount of confining reinforcement was proposed for reasonable seismic design. In addition, appropriateness and safety of the proposed equation were examined based on the various experimental results performed at home and abroad.

  • PDF

Long-Term Behaviors of Reinforced Concrete Pier Structures Considering Long Column Effects (철근콘크리트 장주 교각의 시간에 따른 거동)

  • Jung, Hyun-Soo;Kim, Su-Man
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.69-72
    • /
    • 2005
  • For reinforced concrete column under sustained loads, the member suffers additional lateral deflection due to creep. This deflection leads to additional bending in the member, which in turn causes the column to deflect still further. Therefore the secondary moment due to additional deflection causes an increase in primary moment and the strength of column is reduced. And also creep buckling may occur. On this study, nonlinear analysis of reinforced concrete long column including crack effects is carried out and then the strength of long column is revaluated.

  • PDF

Seismic Analysis of RC Piers being repaired/retrofitted (보수.보강된 철근콘크리트 교각의 내진해석)

  • Lee, Do-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.198-201
    • /
    • 2006
  • In order to evaluate the seismic performance of reinforced concrete bridge piers, an inelastic time-dependent element is proposed. The proposed element enables increased characteristics due to structural intervention (i.e., repair and retrofitting) to be accurately reflected to the degraded strength and stiffness of the members. Comparative studies are conducted for reinforced concrete bridge columns being repaired and retrofitted and show good correlation between analytical prediction and experimental results. In addition, a nonlinear time-history analysis of a reinforced concrete bridge under multiple earthquakes confirms the applicability and effectiveness of the present development.

  • PDF