• Title/Summary/Keyword: 천장온도

Search Result 69, Processing Time 0.037 seconds

Ignition of ceiling insulation depending on working condition of Sprinkler head in underground parking lot fire (지하주차장 화재 시 스프링클러헤드 작동 여부에 따른 천장 위 단열재의 발화 여부)

  • Kim, Seo-Young;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.461-468
    • /
    • 2022
  • This study is focused on the ignition of ceiling insulation depending on working condition of Sprinkler head in underground parking lot fire. When temperature changes of same point were measured depending on sprinkler's working condition, in Scenario 1, inner temperature at border of spray applied material(SP-2) of ceiling part near the fire and ceiling insulation(blowing polystyrene) was 658.27℃ and its which inner maximum temperature is higher than 427℃ which is the ignition point of ceiling insulation(blowing polistyrene), so it was observed that flame is ignited on the ceiling insulation and spread fire. In scenario 2, Inner fire temperature at border of spray applied material(SP-2) and ceiling insulation(blowing polystyrene) near the fire was 53.10℃ and it was lower than ignition point so it was observed that flame was not ignated on the ceiling insulation. As a result, it was foreseen that possibility of ignition on the ceiling insulation depending on working condition of sprinkler.

Measurement of Ceiling Temperature in Tunnel for Heights and Fire Sizes of Fire Source (화원의 높이 및 화재크기별 터널 천장온도 측정 실험)

  • Park, Won-Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.5-10
    • /
    • 2015
  • The "Ondong tunnel" is not used now where is one of the tunnels in the Janghang line which is from Cheonan to Iksan. The length of the tunnel is 214 m. The location of the fire source is center of the tunnel and the pool fire with heptane is for the fire source. Tests are carried out for the various fire sizes, the height and obstructed/open condition of the fire source. Temperature on the top of the tunnel is measured. Even if the fire size is same, the maximum temperature on the ceiling of the tunnel for the elevated fire source is very larger than the maximum for the ground fire source. As the fire size is lager the maximum temperature on the ceiling is higher. These test results can be very useful for design and guidelines of fire detectors in tunnels.

Evaluation of Thermal Comfort in Ceiling Heating System (천장복사난방이 인체에 미치는 쾌적성 평가에 관한 연구)

  • 이주연;이소다노리오;조관식
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.104-108
    • /
    • 2001
  • 복사에 의한 냉난방은, 장시간 재실하는 방이나 소음, 기류에 민감한 장소에 적합하고 에너지 절약면에서도 유효한 냉난방 방식이라고 알려져 있다. 일반적으로 널리 알려져 있는 바닥난방은 실온의 수직분포가 균일함으로서 인체에 쾌적한 난방방식으로 알려져 있다. 이것에 비해, 바닥의외의 벽, 천장을 활용한 냉난방설비의 쾌적성에 대해서는 아직 충분히 검토되고 잇지 않다. 따라서 본 연구는 물순환식 복사 냉난방장치를 이용하여 겨울철의 천장복사난방이 인체에 미치는 생리적, 심리적영향을 밝히고 복사난방의 유용성에 대해서 검토하는 것을 목적으로 한다. 실험은 일본 나라여자대학 인공기후실을 이용하였고, 실험조건은 실온 18$^{\circ}C$, 21$^{\circ}C$, 24$^{\circ}C$ 천장온도 $25^{\circ}C$, 3$0^{\circ}C$, 35$^{\circ}C$의 조건을 조합하여 7조건으로 설정하였다. 또, 상대 습도 40%, 기류속도 0.1m/s 이하로 일정하게 유지시켰다. 생리적반응으로는 피부온14점과 직장온을 30초 간격으로 측정하였고, 혈압, 심박수, 체중, 체지방율을 측정하고 심리적반응으로는 온열감, 쾌적감등의 항목을 10분간격으로 측정하였다.

  • PDF

Effects of Different Ventilation Systems on Rearing Growing-finisher and Indoor Environment in a High Rise Hog Building (고상식 돈사내에서 환기시스템별 환경조사 및 육성비육돈 사육 효과)

  • Yoo, Y.H.;Jeong, J.W.;Park, K.H.;Song, J.I.;Ko, Y.G.;Kim, S.W.;Lee, I.B.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.193-204
    • /
    • 2010
  • The goal of this study was to develop a high-rise hog building(HRHB) for growing-fattening stages. HRHB was two story building and was suitable for specific environment in Korea. Manure was treated in a first floor and pigs were raised on the slatted second floor. Three ventilation systems - 1) duct inlet to wall exhaust system(V1), 2) eave inlet to wall exhaust system(V2), and 3) ceiling inlet to wall exhaust system(V3) - were used. This experiment was conducted during winter and from summer to fall. Air temperature, air speed, ammonia, hydrogen sulfide in HRHB, and swine growth rate were measured. During winter, air temperature in V1 system tended to be slightly high without any effect of outside air temperature. Maximum temperature from summer to fall was between 33.4 and $33.8^{\circ}C$ and there was no significant difference among systems. Continuously measured daily temperature was lower in V2 system than other systems and the fluctuation of air temperature was high. Air speed in V1 and V2 systems were similar (0.02~0.21 m/s), and was 0.04~0.15 m/s in V3 during winter. From summer to fall, air speed in V1, V2, and V3 systems were 0.10~0.41 m/s, 0.10~0.83 m/s, and 0.11~0.26 m/s, respectively. V2 system showed bigger fluctuation of air speed than other systems. During winter, the highest concentrations of ammonia in V1, V2, and V3 systems were 7.0, 3.5, and 8.7 ppm, respectively. Hydrogen sulfide was not detected. The highest concentrations of ammonia from summer to winter in V1, V2, and V3 systems were 6.1, 2.8, and 5.6 ppm, respectively. Swine growth showed no statistical significance among systems. However, daily weight gain was approximately 4% higher in V1 and V3 than in V2. Feed intake/daily weight gain was approximately 4% higher in V1 than other systems. From summer to fall, daily weight gain in V1 and V3 tended to approximately 3% higher than other systems, and feed intake/daily weight gain was approximately 2% higher in V1 than other systems. Hence, V2 system for the ventilation system of HRHB should not be utilized.

Effects of Radiation Heat Transfer on the Fire in an Atrium (아트리움 공간에서 화재발생시 복사열전달의 영향 분석)

  • Yoon, Kyung-Beom;Chang, Hee-Chul;Kim, Tae-Kuk
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.18-24
    • /
    • 2007
  • The purpose of this study is focussed on the numerical predictions of temperature distribution by radiation heat transfer in atrium fire using the field fire model and the CCRHT-3D code. This code uses standard $k-{\varepsilon}$ turbulent model with SIMPLE algorithm and weighted sum of gray gases model regrouping(WSGGM-RG). The WSGGM-RG calculates radiative properties on the reduced computational loads while reserving the accuracy. The numerical results show that lower temperature distributions on the wall and the top ceiling wall can be obtained by considering radiative heat transfer. The temperature on the top ceiling wall can be an important parameter in predicting the operating condition of the sprinkler head.

Experimental Study on the Thermal Properties of Materials for Fire Resistive Ceiling Structure at High Temperature (내화천장구조 재료의 고온 열특성 실험 연구)

  • Yeo, In-Hwan;Cho, Bum-Yean;Min, Byung-Yeol;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.334-339
    • /
    • 2011
  • 이 연구에서는 내화천장구조 재료의 고온 열특성을 파악하여, 건축물 화재시 천장구조에 대한 보다 정확한 화재성상예측을 위한 실험적 자료로 제시하고자 한다. 건축물의 화재성상 예측은 내화설계 시 반드시 필요하며, 화재성상예측을 위해서는 화재하중, 작용외력, 안전계수 및 설계용 정수의 합리적인 설정이 중요하다. 화재하중 및 작용외력 등은 건축물의 부재가 지니는 하중조건에 대한 화재시의 부재 안정성 예측에 관계되는 부분이며, 설계 시 필요한 데이터 중 내화천장구조 재료의 고온 열특성 값은 화재발생 구획의 화재온도가 주요 구조부재에 전달되는 정도를 예측할 수 있는 인자로 볼 수 있다. 따라서 내화천장구조 재료의 고온 열특성 값 설정은 화재발생 공간의 온도범위($20{\sim}1000^{\circ}C$)에 걸쳐 평가 및 분석되어야만 정확하고 신뢰성 있는 화재발생 예상 공간의 부재 온도 및 안전성 분석이 가능하다. 이에 국내 건축구조물에 사용되고 있는 대표적인 내화피복 재료인 방화석고보드, 텍스, 암면에 대해서 $20^{\circ}C{\sim}900^{\circ}C$까지의 열전도율을 측정하였다. 실험결과 방화석고보드와 텍스의 경우 약 0.15 W/m K까지 일정하게 증가하였다. 암면의 경우 약 $700^{\circ}C$까지는 방화석고보드나 텍스에 비해 열전도율이 낮게 나타났지만, $800^{\circ}C$ 지점부터 용융 및 탄화가 진행되면서 열전도율이 급격히 상승하는 것으로 나타났다.

  • PDF

중규모공간에서의 천장형 냉난방기 적용성 평가

  • 이기섭;박효순
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.30 no.4
    • /
    • pp.39-45
    • /
    • 2001
  • 본고에서는 천장형 냉난방기기가 중규모공간에 적용될 때의 온열환경적 쾌적성을 확보하기 위한 기술연구 동향과 아울러 중규모공간에 설치된 경우에 대한 온도 및 기류분포를 사례를 통하여 적용성에 대하여 평가하고자 한다.

  • PDF

Experimental Analysis of Thermal Comfort of an Office Space for Different Supply Locations during Cooling (냉방시 사무실 공간의 급기 위치에 따른 실내 열환경 평가 실험)

  • 김명호;김요셉;김영일
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.11a
    • /
    • pp.115-120
    • /
    • 1999
  • 본 연구에서는 실제 조건과 유사하게 모사된 사무실 공간을 대상으로 냉방시 급기 위치에 따른 기온, 기류속도, 복사온도를 측정하여 열환경을 평가하였다. 사무실 공간은 실제의 조건과 유사하게 인체, 조명, 사무기기의 부하를 전기히터로 모사했으며, 외기부하는 벽체에 설치된 열교환기를 통과하는 부동액의 온도를 제어함으로써 모사하였다. 실험 결과 냉방 조건에서는 바닥급기 방식의 경우 평균온도가 천장급기에 비해 낮아 에너지 절약 측면에서 유리함을 알 수 있었다. 그러나 천장급기에 비해 수직온도차가 크고 급기구 근처에서는 수직온도차에 의한 불쾌감과 빠른 기류속도에 의한 드래프트의 위험이 있는 것으로 나타났다.

  • PDF

Fire Simulation for Vent Flow and Temperature in Engine Room of Small Ship: Effects of Ceiling Duct Location and Side Vent Size (소형선박 기관실의 개구부 유동 및 온도에 대한 화재시뮬레이션: 천장 통풍통 위치 및 측면 개구부 크기 영향)

  • Jeong, Lee-Gyu;Lee, Chi Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.454-465
    • /
    • 2020
  • Fire simulations were performed using the Fire Dynamics Simulator (FDS) software to examine the vent flow and temperature in the engine room of a small ship. A diesel fire with a heat release rate of 10 kW was targeted, and the effects of the ceiling duct location, side vent existence and nonexistence, and side vent size were investigated. The existence or nonexistence of the side vent and its size considerably affected the smoke behavior, mass flow rate through the vent, and temperature. When the side vent was not installed or was small, the smoke layer reached the floor in the engine room. In addition, as the side vent size increased, the mass flow rate through the vent increased with decreasing temperature value. However, the effects of the ceiling duct location on the smoke behavior, mass flow rate through the vent, and temperature seemed to be relatively minor compared to those of the side vent size. Therefore, to improve the fire safety of the engine room in a small ship, the side vent size is considered to be a more important design factor than the ceiling duct location.

Experimental Analysis of Thermal Comfort for Ceiling and Floor Supply Air-conditioning Systems (냉방시 천장분출 및 바닥분출 공조방식에 따른 열환경 평가실험)

  • Cho, Yong;Kwon, Hurk-Seung;Kim, Sung-Hyun;Kim, Yong-Il
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.11a
    • /
    • pp.133-139
    • /
    • 1998
  • 생활수준이 향상됨에 따라 인간의 감성을 생활환경에 적용하려는 연구가 진행되고 있다. 감성에 영향을 미치는 요인은 다양하나 이 중에서도 열환경은 인간에게 미치는 정도가 어떠한 요인보다도 큰 것으로 알려져 있다. 열환경이라 함은 온도, 습도, 기류, 복사열을 말하며 이 요소들은 인간의 감성과 밀접한 관련을 지닌다. 실내의 열환경은 공조방식에 따라 크게 달라지며 본 연구에서는 천장분출과 바닥분출 공조방식의 비교실험을 수행하여 실내의 열환경을 평가한다. 두 공조방식을 여름철 사무실 공간을 모사하는 열환경챔버에 적용하여 실내의 온도, 기류, 복사온도, PMV의 분포를 측정한다. 실험 결과 바닥분출 공조방식이 쾌적성과 에너지 절약면에서 우수함을 알 수 있었다.

  • PDF