• Title/Summary/Keyword: 창문

Search Result 296, Processing Time 0.03 seconds

A Research on Thermal Properties & Fire Resistance of A Water Film Covered Glazing System for Large Atrium Space (대규모 아트리움에 적용되는 수박형성 유리벽의 열적 특성 및 내화성능에 관한 연구)

  • 박형주;지남용
    • Fire Science and Engineering
    • /
    • v.13 no.4
    • /
    • pp.38-55
    • /
    • 1999
  • In order practically to use fire-defective glazing materials for the compartment wall where a fire-protection rating is mandated, there have been many trials internationally, This research focuses on a feasibility that, if certain water film covered all surface of glass, the glazing system can endure without breaking out under the compartment fire. First of all, a water film spray system was specially designed to wet the entire surface of the glass and also to have tiny small amount of water rebounded from the surface after emitted from nozzles. After this system has proven to have perfect performance, small-scale tests were done to find out if the water film covered glazing system react to the high temperature curve in a small furnace room. Finally, on basis of the obtained data, full-scale experiments were done so that water-film covered glazing system can pass the Korean Standard (KS) test for fire resistance, KS F2257.

  • PDF

Balcony window style photo-voltaic(PV) system design by considering resident's residential time rate - Focus on the design of apartment building balcony window PV system and it's performance - (거주자 주택 점유율을 고려한 공동주택 발코니 PV시스템 디자인 - 공동주택의 발코니 PV시스템 디자인과 성능검증 중심으로 -)

  • Chin, Kyung-Il
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.5
    • /
    • pp.101-110
    • /
    • 2009
  • In case of general residential house, photovoltaic can be installed at roof, wall, and any other places. But, in case of apartment building, there has not enough roof space to install photovoltaic panels to supply enough electricity. Actually, apartment building roof and facade wall (exclude the balcony window space) is not enough space to produce and supply the electricity to residents by installing PV panel. Generally, the space of facade balcony with windows in facade wall at apartment building occupied about $70{\sim}80%$, in all facade space. So, if we could use the balcony and windows space in facade as PV to generating electricity, there could contribute the energy saying. But, PV cell is opacify. So if it installed at front window area in apartment building, residents may have displeasure for that opacity character. But the other hand, residents are not always in house especially in day time that is exactly good time for generating electricity by PV. If we can use PV at the facade balcony with window without collusion of resident's displeasure, there have good attraction to using sustainable energy. Hence, this study suggests the design of facade balcony window style PV by considering resident's living pattern in apartment building. The methods of this study are as follows. At first, this study surveyed to the residents about residential time in their home and asked user demand by Delphi survey. At second, this study designed balcony open style PV system which oriented to the user demand. At third, this study tests designed result performance by computer simulation that compared design result with old design. As a result, For the purpose of satisfying the resident demand, there designed sliding window style which slide the several door systems to the one side. That would be make balcony absolute open scenery to the residents. Hence, the designed system performance results were as follows. When we compare the small apartment and large apartment, smaller one has good performance than larger one. Because resident's residential time characteristic. And that has more good electronic performance than vertical style that is similar to roof style.

A Study on the Modernized Application of Korean Traditional Architecture in Ecological Space Design -Centering on the Application of Windows and Doors- (생태학적 공간 디자인에 있어 한국 전통건축의 현대화 응용연구 - 문과 창호의 활용을 중심으로-)

  • 박규현;김민정
    • Archives of design research
    • /
    • v.15 no.4
    • /
    • pp.189-200
    • /
    • 2002
  • Human beings at the beginning of the world have tried to gain mental and physical satisfaction from nature. However, as it became difficult to find such satisfaction in nature, an advanced civilization was created that confronted nature by developing a unique environment. In this process of confrontation, an ecological crisis occurred. As an alternative to solve this problem, there began interest in the ecological paradigm of many fields, and the domain of space design for living became the center of attention. Korean traditional architecture has ecological characteristics suitable for Koreas nature and climate. When discussing Korean traditional architecture from the viewpoint of an ecological paradigm, studies have been based on the understanding that it is the entire combination of structures existing with and as a part of a natural ecosystem rather than the use of independent and individual structures like that of Western architecture. In particular, Korean traditional windows and doors are examples of maintaining an ecological essence by accepting natural surroundings and have important meaning in the subject of ecological space design, but its unfortunate that theyre not utilized in contemporary Korean architecture. Focusing on these discrepancies, this study aims to make traditional windows and doors native to Korea the subject of discussion and to expand the area of study in Korean traditional architecture.

  • PDF

A Study on the tent design of outdoors -focusing on tent color and frame- (야외텐트디자인 개발에 관한 연구 - 칼라와 프레임을 중심으로 -)

  • Heo, Jin-Yong;Yoon, Myung-Han
    • Archives of design research
    • /
    • v.20 no.1 s.69
    • /
    • pp.167-176
    • /
    • 2007
  • As much time is being spent with the family at weekends by the development of leisure culture, many people have begun to enjoy camping in the field. While many people use pensions or camping cars, many families or groups of friends go on camping in the summer holiday season. Although the tent design in this country has gradually been developed, it is not as developed as overseas designs with unique design characteristics according to climate, cultural behavior and colors. In this research, the American and Korea tent designs are compared in terms of color and frame. The differences are analyzed and a direction for tent designs appropriate for Korea in terms of size, area, ease of carriage and installation is proposed through theoretical data and idea sketches. The frame weight has been minimized and the durability increased for the ease of carriage and installation. The style and number of windows have been increased in order to provide a comfortable space by understanding the influx of airflow and the size of the tent has also been increased to provide extra space for storage. The information on the overseas and domestic tent design trends led to a color comparison and the extraction of images of language. The tent based on the new design is currently being mass-produced in China following 3 months of preparation including sample making and testing.

  • PDF

A Study on Facilites Safety of Long-Term Care Facilities for Elderly :Focused on the Factual Survey of Seoul Metropolitan Area (장기요양시설의 노인보호를 위한 시설안전에 관한 연구 : 수도권 시설안전 실태조사를 중심으로)

  • Moon, Yongpil
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.10
    • /
    • pp.308-325
    • /
    • 2020
  • This study examines factual facilites safety of long-term care facilities for eldery, for improvement of Korean policy. So, This study reviewed policies of facilites safety of long-term care facilities on main OECD countries. We analyzed factual survey of facilites safety of long-term care facilities in Seoul metropolitan area. The results of the study were as follows: First, There were differences of law and rule of facilites safety of long-term care facilities in comparison with those of social welfare facilities, child day-care center, hospital. Second, it was the result of location condition analysis. Long-term care facilities in the Seoul metropolitan area were located on more than six floors of buildings. The location conditions of private facilities are weak compared to those of corporations and local governments. Third, there were the result of internal structure of facilities. Overall, the placement status was insufficient. For instance, there are smokeproof masks/fireproof blankets, smoke windows(fire safety windows), smoke smothering. In addition, there were places where legal essential installation structures were insufficient. Private facilities were generally insufficient in facility structures compared to those of local governments and welfare corporations. Fourth, there were the result of safety management. It was confirmed that private facilities were insufficient compared to local government facilities. For instance, there are safety management analysis, response manuals, fire preparedness training, etc. Finally, implications and future directions policies of facilites safety of long-term care facilities were discussed based on the finding of the study.

The comparison between measurement and prediction values for the vertical illuminances by relux program in the survey region (상용 조명해석 프로그램(Relux)을 이용한 가로등 주택침입광 예측값과 실측값 비교)

  • Jung, Dae-Kwan;Park, Hyung-Kyu;Jung, Joon-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.98-104
    • /
    • 2018
  • The assessment of the light trespass in terms of light pollution is difficult due to the complexity of light environments. As a result, the light pollution research has examined the influences of light pollution using simulation program such as RELUX. However, there still exists a differences between the real measurement value and the simulation value for the light trespass. In this paper, we analyzed the light trespass using the RELUX simulation program, and compared results with real measurement values. In this study, the regions (Seoul, Incheon, etc.) were investigated regarding the light trespass for outdoor lighting. The survey of vertical illuminance was analyzed measuring point (more than 2 point) out the window that was expected to light trespass for the higher anticipated to illumination. The illuminational predicted values for the RELUX program were compared with maximum one. As a result of this study, the illuminational errors between the measurement values and predicted values for the simulation were examined from -0.97 lx to 0.65 lx except 2.08 lx and -7.70 lx. The light trespass was analyzed the higher by how much the located close to the height, length, width of the outdoor lighting for the window. For measuring predicted values using RELUX, it was not sufficiently considered in the simulation conditions because of environmental factors and investigator error etc. Limitations of this study include the limited number of measurements, and greater field data is required in future studies.

The Study on the Effect of Elevator Movement on the Pressure Difference between Vestibule and Living room in High-rise Buildings (초고층 건축물에서 엘리베이터 구동이 부속실과 화재실 간 차압형성에 미치는 영향연구)

  • Park, Younggi;Hong, Kibea;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.85-91
    • /
    • 2018
  • Recently, there have been a lot of casualties due to fires in high-rise buildings. The toxic gases and smokes generated by fires in high-rise buildings spread rapidly through the elevator shaft and stairwell, due to the stack effect, and can cause critical casualties. To reduce the number of casualties, smoke control systems have been introduced. Smoke control systems play an essential role in preventing the spread of smoke in high-rise buildings and securing the evacuation route. Also, in high-rise buildings, evacuation by an elevator is considered to be indispensable. However, the pressure field in the shaft is strongly disturbed when the elevator is moving and this can affect the performance of the smoke control system. Therefore, in this study, we experimentally and numerically analyzed the effect of elevator movement on the pressure difference between the vestibule and living room by building a model using the sandwich pressurization method based on the performance based design. To consider the leakage areas in high-rise buildings, e.g. the windows, fire door and elevator, the National Fire Safety Codes and area ratio were used. The elevator speed in the model building was varied between 20 m/s and 100 m/s corresponding to a real elevator speed of 7 m/s~17 m/s. As a result, the relationship between the pressure difference and elevator speed was found to be ${\Delta}P=40{\cdot}{\exp}$(-Ves /-104.7)-23.735. This result can be used to take into consideration the effect of elevator movement when designing smoke control systems.

Comparative on Recovery Efficiency of Spilled Oil by Disk Materials (디스크 소재별 유회수 성능 비교)

  • Jang Duck-Jong;Na Son-Cheol
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2005.11a
    • /
    • pp.165-170
    • /
    • 2005
  • A basic study for the development of a disk type oil skimmer for a tank lorry, compares via experiments to the oil recovery differences by material between the existing oil skimmer disk and several discs which oil adhesion are possible. The experiment results in this study are summarized as follows: In all the disks, the mass of recovery of bunker-A oil was greater than light oil. In light oil, there was nearly no differences in the mass of oil recovery by disk material, but in the case of bunker A oil, recovery efficiency showed big differences depending on the disk materials. For light oil, the differences in the mass of oil recovery per unit of operation time from the initial time zone were hardly shown. However, the mass of recovery of bunker-A oil linearly increased from the initial operation time in all the disks and the increase shaped a slow moving trend as time went on; therefore, the mass of oil recovery per unit of operation time showed differences depending on time. This result shows that oil viscosity has an effect on the disk recovery efficiency. When comparing the mass of pure oil recovery and the mass of water recovery in the total mass of recovery by bunker-A oil, there was no difference in the mass of oil recovery between the window-aluminum material disk and the disks consisting of other materials, but the mass of water recovery of the former was relatively very small. This shows the most ideal result in view of oil recovery efficiency that considers the mass of water recovery. In conclusion, it was found that aluminum is the most advantageous as the material for tank lorry oil skimmer disk.

  • PDF

A Study on the Analysis of Gaze Characteristic of The Villa Savoye - Based on the Difference between Architecture Major Group and Non-Architecture Major Group (빌라 사보아의 건축입면 주시특성 연구 - 건축 전공자와 비전공자의 차이를 중심으로)

  • Cho, Hyeong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.724-731
    • /
    • 2016
  • The purpose of this study was to determine what rules or patterns exist when people gaze at a villa savoye, which is probably Le Corbusier's best known building, using eye-movement tracking techniques. Villa savoye was designed, addressing his emblematic "Five Points", such as pilotis, functional roofs, free floor plans, long horizontal windows, and freely-designed facades. This study examined how the villa savoye's facade image is formed in an objective manner. This study selected a total of 56 test subjects, and showed them an image of a villa savoye. Using eye-movement tracking tools, this study recorded where they mostly gazed at when seeing the building. In addition, an experiment was carried out to test the different points of view, relating to visual attention, between the two groups with different levels of knowledge in architecture. To analyze the data, the Gaze Frequency was used as the key indicator. The results showed that the subjects have a higher degree of attention to either the door or window in general than in former studies. The architecture major group showed that they gazed the experiment image more evenly.

Numerical analysis of solar heat gain on slim-type double-skin window systems - Heat transfer phenomena with opening of windows and vent slot in summer condition - (전산유체 해석을 통한 슬림형 이중외피 창호의 태양열 취득량 분석 - 높은 태양고도 및 하절기 냉방조건에서의 자연환기구 적용 및 창문 조절 방식별 비교 -)

  • Park, Ji-Ho;Oh, Eun-Joo;Cho, Dong-Woo;Cho, Kyung-Joo;Yu, Jung-Yeon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: Heat transfer analysis of recently developed 'slim type double-skin system window' were presented. This window system is designed for curtain wall type façade that main energy loss factor of recent elegant buildings. And the double skin system is the dual window system integrated with inner shading component, enclosed gap space made by two windows when both windows were closed and shading component effectively reflect and terminate solar radiation from outdoor. Usually double-skin system requires much more space than normal window systems but this development has limited by 270mm, facilitated for curtain wall façade buildings. In this study, we estimated thermophysical phenomena of our double-skin curtain wall system window with solar load conditions at the summer season. Method: A fully 3-Dimentional analysis adopted for flow and convective and radiative heat transfer. The commercial CFD package were used to model the surface to surface radiation for opaque solid region of windows' frame, transparent glass, fluid region at inside of double-skin and indoor/outdoor environments. Result: Steep angle of solar incident occur at solar summer conditions. And this steep solar ray cause direct heat absorption from outside of frame surface rather than transmitted through the glass. Moreover, reflection effect of shading unit inside at the double-skin window system was nearly disappeared because of solar incident angle. With this circumstances, double-skin window system effectively cuts the heat transfer from outdoor to indoor due to separation of air space between outdoor and indoor with inner space of double-skin window system.