• Title/Summary/Keyword: 창구화

Search Result 106, Processing Time 0.027 seconds

HPLC Assay and Renal Excretion Characteristics of Theophylline and Its Metabolites in Rat (테오필린과 그 대사체의 HPLC 동시 정량 및 신(腎) 배설 특성)

  • Kuh, Hyo-Jeong;Shim, Chang-Koo;Lee, Min-Hwa;Kim, Shin-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.1
    • /
    • pp.33-41
    • /
    • 1991
  • A high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of theophylline(TP) and its metabolites, 1-methyluric acid (1-MU) and 1,3-dimethyluric acid (1,3-DMU), in rat plasma and urine. An $100\;{\mu}l$ aliquot of a plasma or urine sample was mixed with $250\;{\mu}l$ of acetonitrite and vortexed. After centrifugation, $200\;{\mu}l$ (plasma) or $20\;{\mu}l$ (urine) aliquot of the supernatant was dried by $N_2$ stream and redissolved in $100\;{\mu}l$ (plasma) or $200\;{\mu}l$ (urine) of the mobile phase. A $20\;{\mu}l$ of the mobile phase solution was injected onto a $C_{18}$ reversed-phase column. The column was maintained at $45^{\circ}C$ by the aid of electric heating jacket. The mobile phase was a 3%(v/v) methanol solution in deionized water which contains sodium acetate (100 mM) and tetrabutyl ammonium hydroxide (4 mM). pH of the mobile phase was adjusted 4.5 by the addition of acetic acid. Detection limits for TP, 1-MU, and 1,3-DMU in plasma were 0.2, 0.1 and $0.1\;{\mu}/ml$, respectively and the corresponding values in urine were all $5\;{\mu}g/ml$. Inter- and intra-day variability of the assay for all compounds in the plasma samples was less than 5.5 and 3.8%, respectively. The retention times for 1-MU, 1,3-DMU, and TP were approximately 7, 8.5 and 18 min, respectively. Sample preparation procedure used in this method was simple, rapid and reproducible. Renal clearance of TP and its metabolites in rats showed plasma concentration dependency indicating renal tubular secretion and reabsorption of them.

  • PDF

Challenges of VOD Market of Korean Film Industry: Legislative and Policy Alternatives to Improve its Distribution Structure (국내 영화 온라인 부가시장의 유통구조 합리화 방안)

  • Kim, HwiJung
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.6
    • /
    • pp.354-364
    • /
    • 2016
  • With the advancement of the digital convergence of content and platform, Korean film industry sees good opportunities of maximizing the profits and increased distribution opportunities by independent film makers. Nevertheless, the domestic film market almost entirely relies on the box office sales, which seems to be caused by the stagnation of new additional copyright market. The study aims to address the following problems: First, information asymmetry of the revenues to which the contents providers and the service providers are exposed leads to the distrust among digital film contents businesses and the disadvantages to film makers and investors, in particular. Secondly, the VOD(Video on Demand) market of film industry is adversely affected by the illegal uploads and downloads of film contents, which harms the formation of paid additional market. Based on the examination of current legislation and policy options addressing these issues, the study suggests legislative accomodations and cultural industry policy alternatives to promote the additional market of film industry.

The Effect of Opening Lamina Terminalis on the Development of Hydrocephalus after Aneurysmal Subarachnoid Hemorrhage (동맥류성 뇌지주막하 출혈후의 수두증에 대한 종판 개구의 효과)

  • Hwang, Yeoung Hak;Lee, Dong Hoon;Lee, Sang Hoon;Kim, Ho Kyung;Kang, Chang Gu;Chung, Ui Wha
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.5
    • /
    • pp.609-614
    • /
    • 2000
  • Objective : A retrograde clinical study was undertaken to determine the effect of opening lamina terminalis on the development of hydrocephalus after aneurysmal subarachnoid hemorrhage(SAH). We compared the incidence ratios of the development of hydrocephalus with and without opening lamina terminalis during operation after aneurysmal SAH. Patients and Methods : From Oct. 1996 to Sep. 1998, we performed 138 aneurysm surgery for 122 patients. In 98 cases, the lamina terminalis was opened to make direct cerebrospinal fluid flow from the third ventricle to subarachnoid space for prevention of delayed hydrocephalus. We compared the incidence of hydrocephalus after opening lamina terminalis to those without opened lamina terminalis. Results : In 95 cases, the hydrocephalus was noticed in 2 cases(2.2%). It is significantly lower in the group with opening lamina terminalis than the group without opening lamina terminalis(about 10%). Conclusion : It is simple and easy procedure to open the lamina terminalis during aneurysm surgery. With this maneuver, we could reduce the incidence of hydrocephalus after aneurysmal spontaneous SAH. Thus, it is considered that the opening lamina terminalis is one of the effective methods for preventing the development of hydrocephalus after aneurysmal spontaneous SAH.

  • PDF

Development of Controlled Release Oral Drug Delivery System by Membrane-Coating Method-II-Correlation Between Acetaminophen Concentrations in Plasma and Sativa Samples of Man- (피막법에 의한 경구투여용 제어방출 제제의 개발-II-사람에 있어서 아세트아미노겐 혈장 중 농도와 타액 중 농도와의 상관성-)

  • Shim, Chang-Koo;Kim, Mi-Ae;Lee, Min-Hwa;Kim, Shin-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • v.20 no.1
    • /
    • pp.29-33
    • /
    • 1990
  • Plasma and saliva concentrations of acetaminophen (AAP) were determined at various time points by HPLC after oral administration of AAP tablets (AAP 500 mg) to four healthy male Korean subjects. Saliva concentrations (S) of AAP were significantly correlated with plasma AAP concentrations (P). The S/P ratio of AAP was calculated to be 1.05 (r =0.944, $p<10^{-6}$) for all the data points from the subjects. It showed a little intersubject variation and ranged from 0.89 to 1.46 in each subject. Bioavailability parameters such as AUC, $C_{max}$ and $T_{max}$ which are usually obtained from the plasma concentration data will be predictable approximately by saliva concentration data. Saliva seems to be very convinient and useful samples for the preliminary studies of bioavailability and bioequivalence of AAP preparations, since it can be collected frequently without any painful venipuncture to the subjects, that is inevitable in plasma sampling. Evaluation of the bioavailability of a preparation by saliva samples will reduce the cost, time and safety risk greatly in developing a new drug delivery system for AAP.

  • PDF

Development of Multi-purpose Marine Wastes Cleaning Systems for the Shallow Waters(PART II : System Development and Performance Evaluation) (천수용 다기능 해양폐기물 수거시스템 개발(PART II : 시스템 구성 및 성능시험))

  • Cho Yong-Jin;Moon Il-Sung;Shin Myung-Soo;Yu Jeong-Seok;Kang Chang-Gu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.5 no.2
    • /
    • pp.62-67
    • /
    • 2002
  • This paper - following 'Development of multi-purpose marine waste cleaning systems for the shallow waters (Part I : preliminary conceptual design)'- describes on the system development and the sea trial performance evaluation(Cho[2003]). The multi-functional seabed waste collecting system and the towing hook system were developed. The maximum working depth of these systems are 15 and 100 meters, respectively(MOMAF[2001]). For the multi-purpose use to collect the marine waste, this system contains floating waste collecting device for the waste on seawater and remained waste collecting device for the waste on seabed, while steel wire cutting system is added for higher efficiency In order to evaluate the system performance, the prototype of multi-functional system was constructed and the sea trial test at shallow water were carried out. As a result, this system operated well with safe and without any interaction so that the developed systems are practicable and applicable.

  • PDF

Management of Knowledge and Information Resources Made by Research Institutes: Focusing on the Homepags of Educational Research Institutes (연구기관 생산 지식정보자원 관리에 관한 연구: 교육연구기관 홈페이지를 중심으로)

  • Lee, Myeong-Hee
    • Journal of Korean Library and Information Science Society
    • /
    • v.46 no.1
    • /
    • pp.177-202
    • /
    • 2015
  • This research was conducted to evaluate whether knowledge and information resources produced in four educational institutions function as a knowledge management system in the institutions, and to suggest a proposed plan for the foundation of the national knowledge management system. Knowledge and information resources available on the institutes' websites were classified as 'knowledge and information resources of result', 'knowledge and information resources of process', and 'knowledge and information resources of communication'. The application of metadata and the configuration of the search system were examined by content analysis method. From the result, 8 ways to improve the management of knowledge and information resources have been found; the development of standardized metadata and classification scheme, high recognition that the website is a counter for external distribution of knowledge and information resources, various searching skills and the provision of knowledge maps available, provision of linked information for original information acquisition, awareness of the agency managers and homepage managers to the homepages as knowledge management systems, segmentation of appropriate data size unit in a mobile environment work, an organic linkage function of the internal electronic approval system and the homepage have been proposed.

Performance and Alternative Policies of Techno-Park Built-up Project in Korea (테크노파크 조성사업의 성과와 정책과제)

  • Lee, Chul-Woo;Kim, Myeong-Yeob
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.19-37
    • /
    • 2009
  • The techno-park built-up project of Korea had begun in order to support regional enterprises since 1997. The number of techno-parks increased from 6 in 1997 to 17 in 2009 with various enterprise supporting services such as a new enterprise breeding, pilot production, and education and training. By way of renewing regional innovation promoting system, revising technopark law, and starting second step techno-park project, techno-parks have become centers for regional technology innovation, and cultivation of regional technology-based companies. Alternative policies for the development of techno-park projects are as follows: revitalizing the network among enterprises, universities, research institutes, and government; strengthening the ability to draw up projects in nurturing regional industry; and the establishment of fixed channels to support SME in the region.

  • PDF

Analysis of the Precautionary Measures and Causes on Explosion Accidents of a Old Dry Chemical Powder Extinguisher (노후 분말소화기의 폭발사고 원인과 예방대책에 관한 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.91-99
    • /
    • 2012
  • Fatal injuries and deaths have occurred resulting from the operation or disassembling of a powder extinguishers in Korea. If a rusted powder extinguisher is exploded during operation or disassembling, it rises to the air like a rocket and hits a head, chest, or neck part of an operator, resulting in his (her) death or injury. In this study examines the explosion accident cases of a powder fire extinguisher and analyzes their causes, reactions to explosion, and precautionary measures. And in this paper suggests 1) no using of old fire extinguishers in fire drill or education, 2) education and public information on danger of old fire extinguishers, 3) indication of explosion danger to cartridge-type dry chemical powder fire extinguishers had already placed to buildings etc., 4) obligatory indication of durable years on fire extinguishers, 5) examination for introduction of system that do hydraulic pressure test about fire extinguishers that given period past, 6) construction of system that reclaim old fire extinguishers, 7) construction of system that recycle or reuse old fire extinguishers, and 8) operation of help desk related to old fire extinguishers as precautionary measure of fire extinguisher explosion accidents.

Development of $K-BEtest^{\circledR}$, a Computer Program for the Analysis of Bioequivalence ($K-BEtest^{\circledR}$, 새로운 생물학적 동등성 시험 통계처리 프로그램의 개발)

  • Lee, Young-Joo;Choi, Jung-Ho;Song, Sae-Heum;Seo, Chul-Hwan;Kim, Dong-Sup;Park, In-Sook;Choi, Ki-Hwan;Na, Han-Kwang;Chung, Suk-Jae;Lee, Min-Hwa;Shim, Chang-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.28 no.4
    • /
    • pp.223-229
    • /
    • 1998
  • A computer program for personal computers, $K-BEtest^{\circledR}$, was developed to analyze bioequivalence data in accordance with Korean Guidelines for Bioequivalence Test (KGBT). This program is user-friendly, interactive, Hangul-compatible and supports $2{\times}2$ cross-over design as well as $2{\times}2$ Latin square design with various significance levels. This program is able to calculate AUC, $C_{max}$ and $T_{max}$ parameters from the blood drug concentration-time profile of individual subjects and evaluate the parameters statistically for the bioequivalence by ${\pm}20%$ rule, the F-test, the Non-centrality test and 90% confidence intervals. All procedures are supported with graphic interface, interactive menu and outputs in Korean. In this paper, two experimental data sets were analyzed by the program and detailed process was demonstrated. The $K-BEtest^{\circledR}$ program appears to be very effective for analyzing bioequivalence data and can be widely used with convenience and accuracy.

  • PDF

Simultaneous Determination of Haloperidol and Its Metabolite, Reduced Haloperidol, in Plasma by Gas Chromatography Using Nitrogen Phosphorous Selective Detection (Gas Chromatography-Nitrogen Phosphorous Selective Detection을 이용한 혈장중 Haloperidol 및 대사체인 Reduced Haloperidol의 동시정량)

  • Park, Kyoung-Ho;Lee, Min-Hwa;Shim, Chang-Koo;Lee, Myung-Gull;Park, Jong-Sei
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.3
    • /
    • pp.197-204
    • /
    • 1992
  • A gas chromatographic method using nitrogen phosphorous selective detection was developed for simultaneous determination of haloperidol and its metabolite, reduced haloperidol, in human plasma. Combelen was used as internal standard, The method involved extraction and trimethylsilylation followed by the injection of $2-4\;{\mu}l$ of benzene layer, which was used to dissolve the trimethylsilylated derivatives of haloperidol and reduced haloperidol, onto SE-54 column [5% phenyl methyl silica fused capillary column, $16m{\times}0.22\;mm$ $(I.D.){\times}0.33\;{\mu}m$ (coated thickness)]. The temperature of column oven was programmed from $200^{\circ}C\;to\;300^{\circ}C$ at the increase rate of $10^{\circ}C/min and also the temperatures of injector and detector were set at $300^{\circ}C$. Helium was used as carrier gas and its flow rate was maintained at 30 ml/min. The detection was conducted with nitrogen phosphorous selective detector. The retention times for combelen, reduced haloperidol and haloperidol were found to be 9.14, 9.75 and 9.99 min, respectively. The detection limits for haloperidol and reduced haloperidol in human plasma were both 0.2 ng/ml. The coefficients of variation of the intra-assay were generally low (below 9.8%). The mean absolute recoveries of added haloperidol and reduced haloperidol from plasma were 72% and 84%, respectively. No interferences from endogenous substances were found.

  • PDF