• Title/Summary/Keyword: 참조준위

Search Result 14, Processing Time 0.027 seconds

Patient Radiation Dose Values During Interventional Cardiology Examinations in University Hospital, Korea (심장혈관 조영술과 심장혈관 인터벤션의 환자 선량 평가)

  • Kim, Jung-Su;Lee, Joun-Hyuk;Jung, Hae-Kyoung;Kim, Jung-Min;Cho, Byung Ryul
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.27-33
    • /
    • 2016
  • The use of cardiac angiography (CA) and the interventional procedures is rapidly increasing due to the increase in modern adult diseases. Cardiovascular intervention (CI) is an examination method where radiation is applied to the same area for a long period, and thus may cause skin injury. In this study, we investigate the diagnostic reference level (DRL) of the cardiovascular intervention (CI) carried out by medical institutions and use it as a tool to reduce patient exposure dose. In this study, the DRL was set by acquiring information about the cumulative fluoroscopy time, cumulative fluoroscopy dose-area product (DAP), radiography DAP, cumulative DAP, air kerma, number of video clips, and the total number of images from the cardiac angiography and interventional procedures performed on 147 patients. The DAPs corresponding to the DRL of cardiac angiography(CA) and that of the interventional procedures were shown to be $44.4Gy{\cdot}cm2$ and $298.6Gy{\cdot}cm2$, respectively; the corresponding DRLs of fluoroscopy time were shown to be 191.5s and 1935.3s, respectively. A DRL is not a strict upper bound for radiation exposure. However, the process of setting, enacting, and reviewing the DRLs for the dose by medical institutions will contribute to a reduction in the unnecessary exposure dose of patients.

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

Licensing Review Scheme for Low and Intermediate Level Radioactive Waste Disposal Facility ($\cdot$저준위방사성폐기물처분시설 인허가심사 방안)

  • 전제근;정승영;장재권;이관희;박원재;박상훈
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.283-289
    • /
    • 2003
  • In order to establish the licensing review system for LILW disposal facility, we have studied the licensing review structure of oversea's countries, including United State, Japan, and France. We have also reviewed the domestic licensing review structure and the current status of development of safety standards for LILW management. A licensing review for LILW disposal facility can be implemented in 5-6 steps according to Atomic Energy Act. It is estimated to take 32 months for the CP and the OL review for LILW disposal facility referencing to the licensing review practice of the nuclear power plant. To date, a total of 15 MOST Notices have been developed to apply to the safe management of radwaste and 5 more MOST Notices will be developed by 2005.

  • PDF

Review of International Cases for Managing Input Data in Safety Assessment for High-Level Radioactive Waste Deep Disposal Facilities (고준위방사성폐기물 심층처분시설 안전성평가 입력자료 관리를 위한 해외사례 분석)

  • Mi Kyung Kang;Hana Park;Sunju Park;Hae Sik Jeong;Woon Sang Yoon;Jeonghwan Lee
    • Economic and Environmental Geology
    • /
    • v.56 no.6
    • /
    • pp.887-897
    • /
    • 2023
  • Leading waste disposal countries, such as Sweden, Switzerland, and the United Kingdom, conduct safety assessments across all stages of High-Level Radioactive Waste Deep Geological Disposal Facilities-from planning and site selection to construction, operation, closure, and post-closure management. As safety assessments are repeatedly performed at each stage, generating vast amounts of diverse data over extended periods, it is essential to construct a database for safety assessment and establish a data management system. In this study, the safety assessment data management systems of leading countries, were analyzed, categorizing them into 1) input and reference data for safety assessments, 2) guidelines for data management, 3) organizational structures for data management, and 4) computer systems for data management. While each country exhibited differences in specific aspects, commonalities included the classification of safety assessment input data based on disposal system components, the establishment of organizations to supply, use, and manage this data, and the implementation of quality management systems guided by instructions and manuals. These cases highlight the importance of data management systems and document management systems for securing the safety and enhancing the reliability of High-Level Radioactive Waste Disposal Facilities. To achieve this, the classification of input data that can be flexibly and effectively utilized, ensuring the consistency and traceability of input data, and establishing a quality management system for input data and document management are necessary.

A Literature Review and Analysis of Dosimetry in Panoramic Radiography (파노라마 촬영의 피폭선량에 관한 문헌분석 연구)

  • Kweon, Dae-Cheol;Dong, Kyung-Rae;Jung, Jae-Eun;Lee, Kyeong-Hee;Kim, Soo-Kyung;Kim, Wook-Tae;Lee, Cheong-Jae;Song, Woon-Heung;Ma, Sang-Chull
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Dental panoramic radiography is an imaging technique which shows the information of teeth, jaws and superficial structures on a single image. In this study, we propose the clinical dose reference for dental panoramic radiography. Dental panoramic radiography is an application which can increase the radiation does of oral cavity. It is very important to study the real condition of management for these panoramic X-ray equipments. Since there was no researches on dental panoramic equipments in domestic and foreign study groups, we measured and analyzed the dose such as effective dose, DAP and DWP of panoramic radiography.

Cost-benefit Analysis on Occupational Reference Levels for Radon (지각방사선(라돈) 참조준위별 저감 대책에 따른 비용 편익 분석)

  • Choi, Eun-Hi;Chung, Eun Kyo;Kim, Su-Geun;Jung, Myung-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.1
    • /
    • pp.57-68
    • /
    • 2019
  • Objective: The purpose of this study is to propose the benefits of reduction measures according to the occupational radon reference level in order to present basic data for radon management guidelines considering domestic circumstances. Methods: This study uses radon data measured in the subway stations from 2015 to 2016. Of the total of 4,643 cases, 4,231 cases were analyzed excluding the 412 cases where the values were below $300Bq/m^3$. Results: Cost-Benefit analysis was done on the results of the field survey on subway work sites. At the exposure level of $400Bq/m^3$, the ratio between the cost and the benefit was highest at 1 : 1.81(the cost was KRW 1,398,568,032, while the benefit KRW 2,5248,772,841). At the exposure level of $600Bq/m^3$, the ratio of cost and benefit was 1: 1.80, at $300Bq/m^3$ it was 1.72, at $800Bq/m^3$ it was 1.71, at $200Bq/m^3$ it was 1.54, and at $100Bq/m^3$ it was 1.40. Conclusions: Radon management in the workplace provides economic benefits and appropriate reduction strategies are needed. In addition, it is necessary to establish and distribute radon exposure assessment procedures and guidelines for the safety and health of employees when exceeding the exposure standard, and guidelines for radon management in the workplace should be established.

Analyzed the Computed Tomography Dose Index (CTDI) to the Pediatric Brain CT by Reason of the Observation for the Exposure Dose: Base on a Hospital (소아 두부 전산화단층촬영 선량지표 분석을 통한 피폭선량 모니터링: 일개병원 사례 중심으로)

  • Lee, Jae-Seung;Kim, Hyun-Jin;Im, In-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.290-296
    • /
    • 2015
  • The purpose of this study was to derive the proposals and to suggest the exposure dose reduction scheme on pediatric head CT scan by analyzing and comparing CT dose index (CTDI) and the national diagnostic reference levels. From January 2014 to December, 231 children under 10years who were requested a pediatric head CT scan with head injury were examined. Research methods were to research and analyze the general characteristics kVp, mA test coverage $CTDI_{vol}$ and DLP referring to dose reports and electronic medical record (EMR). As a result, 7.4%(17 patients) of the total subjects in $CTDI_{vol}$ showed a national diagnostic reference levels exceeding. For DLP 41.6%(96 patients) in excess was relatively higher than $CTDI_{vol}$. DLP was exceeded more than about 60% that is higher than the CT dose index presented by Korea Food & Drug Administration. it is cause of high DLP that scan range increased more than about 30% wider than the standard test coverage presented in Health Insurance Review & Assessment Service. In conclusion, it is able to significantly lower the dose if it is complied with checking the baseline scan range of pediatric head CT scan and appropriately adjusting the protocol.

A Preliminary Investigation of Radon Concentration for Some Agricultural Greenhouses in Jeju Island (제주지역 일부 농업 시설 내 라돈 농도 예비 조사)

  • Kang, Tae-Woo;Song, Myeong-Han;Kim, Tae-Hyoung;Chang, Byung-Uck;Kim, Young-Jae;Kim, Geun-Ho;Park, Jae-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • BACKGROUND: A preliminary investigation of the radon ($^{222}Rn$) concentration has been conducted, employing solid-state nuclear-track detectors (SSNTD) and a continuous radon monitor (CRM), for fourteen randomly selected agricultural greenhouses in Jeju Island, where the underground-air was used for air conditioning and $CO_2$ supplement. METHODS AND RESULTS: The SSNTD was used to measure the average radon concentration for three months and the CRM was used for an instantaneous measurement. In order to obtain the radon concentration of a greenhouse, the SSNTDs were placed at a number of evenly distributed points inside the greenhouse and the mean of the measured values was taken. In addition, in order to assess the radon concentration of the underground-air itself, measurement was also made at the borehole of the underground-air in each agricultural facility, employing both the SSNTD and CRM. It is found that the radon concentration of the greenhouses ranges higher than those not using the underground-air and the average of Korean dwellings. While the radon concentration of most agricultural facilities is still lower than the reference level (1,000 Bq/$m^3$) recommended by the International Radiation Protection Committee (ICRP), three facilities at one site show higher concentrations than the reference level. The three-month-averaged radon concentration and the instantaneous radon concentration of the underground-air itself ranges 1,228- 5,259 and 3,322-17,900 Bq/$m^3$, respectively, and regional variation is more significant. CONCLUSION: From this results, radon concentration of the underground-air is assumed that it is associated with the geological characteristics and the boring depth of the region located of their.

Analysis of the Effectiveness of Emergency Response Measures during the Design Basis Accident of the Research Reactor 'HANARO' using MACCS2 Code (MACCS2 코드를 이용한 연구용원자로 '하나로' 설계기준사고시 비상대응조치 효과분석)

  • Lee, Goan-Yup;Kim, Jong-Su;Lee, Hae-Cho;Kim, Bong-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.109-117
    • /
    • 2014
  • Nuclear emergency planning is to plan sheltering, evacuation and iodine prophylaxis for the residents living in the area where the emergency plan is needed, the area is confirmed based on the dose assessment using the source-term through an accident analysis and the data measured from meteorological tower. In this study, the does change before and after protective measures was assessed stochastically based on the one year meteorological data in the condition of the maximum hypothetical accident which can be considered at the research reactor 'HANARO', and the optimized protective measures were derived based on the reference levels defined as a residual dose by ICRP 2007 recommendation which can be applied in a emergency exposure situation. The optimized protective measures for the HANARO in the maximum hypothetical accident were the evacuation to radius 300 m, the sheltering from 300 m to 800 m, the iodine prophylaxis only for the emergency workers under the protective measures for non emergency workers.