• Title/Summary/Keyword: 참조시설

Search Result 84, Processing Time 0.027 seconds

Design of Anti-Surge Valve for FPSO Fuel Gas Compressor System (FPSO용 연료가스압축 시스템을 위한 서지방지 밸브 설계)

  • Park, Hyung-Wook;Cho, Jong-Rae;Lee, Seung-Min;Park, Jong-Jin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.443-450
    • /
    • 2011
  • Fuel gas compressor system is applied to medium FPSO. In order to avoid surge, this system used the anti-surge valves. When surge occurs it may lead to system's fracture. So anti-surge valves are evaluated structural strength and structural safety. Especially, in emergency mode, valves are must be guaranteed structural safety. In this study, structural strength and structural safety of anti-surge valve was evaluated using the numerical simulation. Unigraphics NX 4.0 was used as Geometrical models, structural strength and structural safety calculation were carried out by ANSYS Workbench 12.1. The ASME Boiler & Pressure Vessel Code is refer to allowable strength and safety factor of the valves.

Consideration of Regulatory Systems for Decommissioning of Nuclear Power Plants (원자력발전소 해체 규제제도 개선을 위한 각국의 제도 고찰)

  • Ahn, Sang-Kyu;Jeon, In-Young;Cheong, Jae-Hak;Choi, Kyung-Woo;Jeong, Chan-Woo;Lee, Youn-Keun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.4
    • /
    • pp.401-409
    • /
    • 2006
  • Regulatory systems for decommissioning of nuclear power plants in several countries, such as Japan, United States of America, Germany, United Kingdom, France, and Republic of Korea, are surveyed. In the survey, regulatory policies, legislations, licensing process, inspection and public involvements for decommissioning are identified and compared. Afterwards, the survey results will be utilized as a reference to establish the improvement directions of domestic regulatory system.

  • PDF

The Analysis of Design Flood According to Climate Change in Han River Basin (기후변화를 고려한 한강유역의 설계홍수량 분석)

  • Kim, Sunghun;Kim, Sooyoung;Jang, Hanjin;Heo, Jun-Haeng
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.95-95
    • /
    • 2015
  • 전 세계적으로 기후변화에 따른 영향을 전망하고 분석하는 연구가 활발히 진행되고 있으며, 우리나라 역시 기후변화 시나리오에 따른 영향평가를 실시하고 증가하는 위험에 대처하기 위한 다양한 연구가 진행되고 있다. 2013년부터 IPCC(Intergovernmental Panel on Climate Change)에서 배포하는 RCP(Representative Concentration Pathway) 시나리오에 의하면 우리나라의 연평균 강수량과 호우일수는 뚜렷하게 증가할 것으로 전망되고 있다. 하지만, 수공구조물을 설계하는데 있어서 기후변화의 영향을 고려한 설계기준은 미흡한 실정으로 본 연구에서는 우리나라 한강 유역을 대상으로 기후변화 시나리오에 따른 설계홍수량을 분석하였다. 유출량은 실무에서 널리 사용하고 있는 HEC-1을 이용하여 산정하였고, 입력매개변수 중 강수인자는 RCP 시나리오 기반의 확률강우량을 적용하였다. 또한, 한강유역종합치수계획(2008)을 참조하여 나머지 매개변수를 사용하였다. 본 연구를 통하여 RCP 기후변화 시나리오 기반의 확률홍수량을 산정하여 점차 증가하는 홍수위험도에 능동적으로 대처할 수 있도록 기존 하천시설물의 설계 기준의 타당성을 분석하고자 한다.

  • PDF

An Experimental Study on Flow Characteristics Around Culvert According to Blocked Area (차단면적 변화에 따른 암거주변 흐름특성 실험연구)

  • Kim, Sung Joong;Yeo, Hong Koo;Kang, Jun Gu;Jung, Do Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.467-467
    • /
    • 2016
  • 암거는 일반적으로 용수나 배수용의 수로가 도로, 철도, 제방 등의 아래에 매설 된 수로를 지칭한다. 이러한 암거는 산업발전으로 사회기반시설의 신설 및 확충, 재정비 등으로 많이 활용되고 있다. 최근 들어 기후로 인한 재해가 급증하면서 이러한 시설물에 대한 안정성 및 관리에 대한 관심이 높아지고 있는 것이 현실이다. 특히 소하천은 집수면적 및 유로연장이 짧고 하상경사가 급하기 때문에 홍수에 취약하다. 즉, 빨라진 유속으로 인해 구조물 주변의 세굴에 의한 유실, 토사유출로 인한 하상퇴적, 부유물로 인한 차단으로 인해 통수에 지장을 받아 피해가 발생하게 된다. 이러한 암거시설물 피해는 2차 피해로 이어질 수 있으며 사회기반시설 파괴로 도시기능이 마비되고 인근 주변지역에 침수로 인한 재산 및 인명피해까지 발생시킬 수 있는 피해 잠재능력을 보유하고 있다. 그러나 피해에 대한 예방대책은 유지관리를 통해 지속적으로 관리하는 것이 대부분의 지침 등에 소개된 내용들이다. 본 연구에서는 암거를 대상으로 암거의 폐색으로 인해 암거주변에서 변화되는 흐름특성을 축소모형을 통해 검토하고자 하였다. 암거 축소모형실험은 1.5m 폭을 갖는 직선수로에서 수행하였으며, 암거모형은 도로암거표준도(2008)를 참조하여 $3m{\times}3m$ 수로암거를 대상으로 1/10 축소모형을 제작하였다. 암거유입부 퇴적으로 인한 암거의 차단률(차단면적/암거단면적)은 차단이 발생하지 않는 0% 조건에서부터 10%, 20%, 30%, 40%, 50% 조건에 대해 실험을 수행하였다. 실험결과 차단에 따른 암거 상류단의 수위는 차단이 없는 암거의 경우에 비해 차단율이 높아질수록 암거유입부 수위는 20.4% ~ 82.7% 상승하는 것으로 나타났다. 암거의 차단률이 40% 이상일 경우 높아진 수위로 인해 암거통로의 윗상면부까지 다다르고 있으며 50%일 경우 암거를 통과하는 흐름이 자유수면흐름이 아닌 오리피스 흐름이 발생하는 것으로 나타났다. 암거유입부 차단으로 인한 암거주변의 최대유속은 암거 직하류부에서 주로 발생하여 암거 유출부에서의 최대유속은 차단율이 증가할수록 선형적으로 증가하는 것으로 나타났으며 암거 유출부에서의 유속은 차단전의 조건(0%) 대비 4.2% ~ 35.5% 까지 상승하는 것으로 나타났다. 이와 같은 결과를 토대로 고려하였을 때 대부분 산지부에서 설치되는 암거의 경우 유속이 불가피하게 증가하게 됨으로 유속에 따른 유속조절방안(차단 및 우회시설) 및 세굴대책을 세워야 할 것으로 판단된다.

  • PDF

Solar Irradiance Estimation in Korea by Using Modified Heliosat-II Method and COMS-MI Imagery (수정된 Heliosat-II 방법과 COMS-MI 위성 영상을 이용한 한반도 일사량 추정)

  • Won Seok, Choi;Ah Ram, Song;Il, Kim Yong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.5
    • /
    • pp.463-472
    • /
    • 2015
  • Solar radiation data are important data that can be used as basic research data in diverse areas. In particular, solar radiation data are essential for diverse studies that have been recently conducted in South Korea including those for new and renewable energy resource map making and crop yield forecasting. So purpose of this study is modification of Heliosat-II method to estimate solar irradiance in Korea by using COMS-MI imagery. For this purpose, in this study, errors appearing in ground albedo images were corrected through linear transformation. And method of producing background albedo map which is used in Heliosat-II method is modified to get more finely tuned one. Through the study, ground albedo correction could be successfully performed and background albedo maps could be successfully derived. Lastly, In this study, solar irradiance was estimated by using modified Heliostat-II method. And it was compared with actually measured values to verify the accuracy of the methods. Accuracy of estimated solar irradiance was 30.8% RMSE(%). And this accuracy level means that solar irradiance was estimated on 10% higher level than previous Heliosat-II method.

COBie Based Maintenance Document Generation of Railway Track (COBie 기반 철도 선로유지관리 문서 생성)

  • Seo, Kyung-Wan;Kwon, Tae-Ho;Lee, Sang-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.4
    • /
    • pp.307-312
    • /
    • 2017
  • In this study, we proposed a method to generate a maintenance documents for railway track through Construction Operations Building information exchange(COBie) which is a subset of Industry Foundation Classes(IFC), a data model for Building Information Modeling(BIM). In order to define the items necessary for railway track maintenance document generation, we analyzed the guideline of maintenance and management to track by the Ministry of Land, Infrastructure and Transport(MLTM), and defined the way to refer to the information items in the COBie spreadsheet. The additional properties not supported in IFC, were created for generation of an Information model that reflecting maintenance information items of railway track by applying user-defined property set within the IFC framework. An IFC-based Information model reflecting the user-defined property was implemented through BIM software, and rail track maintenance information items were transferred to COBie spreadsheet according to the defined approach. It is tested that the information can be transferred from the IFC-based as-built model to the COBie spreadsheet, which can be used to generate the necessary documents for railway facility maintenance work.

Utilization of Coordinate-Based Image for Efficient Management of Road Facilities (효율적인 도로시설물 관리를 위한 좌표기반 영상의 활용)

  • Lee, Je-Jung;Kim, Min-Gyu;Park, Jun-Kyu;Yun, Hee-Cheon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.4
    • /
    • pp.13-21
    • /
    • 2011
  • Update of road facilities database such as road sign, traffic lights, and street lights is interesting business in a local government. Recently, existing road facilities database, aerial photo and topographic map are referred for the installation and complement of road facilities. But it is difficult to comprehend road facilities' condition and additional expenses may appear in field survey. Therefore, it is necessary to establish and update road facility DB and many studies has been carried out to efficiently collect road related spatial data. In this study, the establishment of various complicated road facility DB was conducted by images that had been obtained by digital camera with a built-in bluetooth and DGPS. Results showed that road facility DB was constructed effectively and suggested the possibility of road facility management using images based on coordinate through accuracy analyses using total-station surveying. And using digital camera and DGPS is expected to effective real-time update and management of road facility DB.

Design of Information System for Assisted Living (장애인 및 노약자를 위한 이동 및 생활지원시스템 설계)

  • Nam, Doo-Hee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.2
    • /
    • pp.83-88
    • /
    • 2011
  • Rapid transition to aging society faces many problems. Also there are so many issues related people with disabilities. Disabled and elderly population growth is causing serious social problems. The purpose of this study is to solve the graying society-problem and improve old people's quality of life as well as the disabled's. The main goal of this study is the design of the master plan for ubiquitous-city by referring the 'Ubiquitous urban planning guidelines' of MLTM(Ministry of Land, Transport and Maritime Affairs). For research and development, there is divided by a spatial scope and content scope. As reference model-type, the spatial scope is to pursue maximum function by using minimum system organization and virtual city-set. The content scope consists of services for the disabled and aged, information management, construction management, compatible & connection and Executive Management. The result of this study will contribute to solve the social problems with aged and disabled and advance ubiquitous-environment by improving people's quality of life.

Heat balance analysis for process heat and hydrogen generation in VHTR (공정열 및 수소생산을 위한 초고온가스로 열평형 분석)

  • Park, Soyoung;Heo, Gyunyoung;Yoo, YeonJae;Lee, SangIL
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.85-92
    • /
    • 2016
  • Since the power density of the VHTR(Very High Temperature Reactor) is lower, there is less possibility of core melt. VHTR has no risk of explosion caused by hydrogen generation when the loss of coolant accident occurs, which is another advantage. Along with safety benefit, it can be used as a process heat supplier near demand facilities because coolant temperature is very high enough to be used for industrial purpose. In this paper, we designed the primary system using VHTR and the secondary system providing electricity and process heat. Based on that 350 MW thermal reactor proposed by NGNP(Next Generation Nuclear Part), we developed conceptual model that the IHX(Intermediate Heat Exchanger) loop transports 300 MW thermal energy to the secondary system. In addition, we analyzed thermodynamic behavior and performed the efficiency analysis and optimization study depending on major parameters.

A Case Study of Site Investigation on OO Gas Station (국내토양오염 유발시설별 오염현황 조사 I -OO인근주유소 오염현황조사-)

  • 김무훈
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.3
    • /
    • pp.81-88
    • /
    • 1997
  • The purpose of this study is to assess contaminant transfer and environmental impacts to the surroundings by inadequate control of USTs. Several methodologies can be used in sampling procedure for the site assessment depending on the appearance of contaminants on the site and their types. In this case study because of site contaminants, randomized and/or triangle matrix techniques were used. As a result, the composition of materials in OO gas station were appeared in several status. From 1 to 2.5m depth, the soil was composed of silty sand and gravel, around 4m depth, weathered rock was appeared. Based on the preliminary and actual site investigation by DPT methodologies on the width and depth of the site with analysis of BTEX and TPH, no contamination was found in OO gas station, however, in one point because of careless dumping after refill by oil company, about 1731. 5 ppm of TPH appeared.

  • PDF