• Title/Summary/Keyword: 착의 실험

Search Result 175, Processing Time 0.02 seconds

INFLUENCE OF LIGHT IRRADIATION OVER SELF-PRIMING ADHESIVE ON DENTIN BONDING (상아질접착제에 대한 광조사가 접착에 미치는 영향)

  • 류현욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.409-417
    • /
    • 2001
  • The purpose of this study was to investigate the influence of light irradiation over self-priming adhesive on dentin bonding. After acid etching the exposed dentin, a self-priming adhesive (Prime&Bond$^{\circledR}$NT dental adhesive system Dentsply DeTrey, GmbH, Konstanz, Germany) was applied and light irradiation was done for 20 sec with regular intensity (600 mW/$\textrm{cm}^2$) in group I and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in group III. No light irradiation was done over self-priming adhesive in groups II and IV. Composite resin was added on the self-priming adhesive and irradiated for 40 sec with regular intensity (600 mW/$\textrm{cm}^2$) in groups I and II and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in groups III and IV. To see the effect of light curing time on dentin bonding, another 3 group specimens were prepared. Without light-irradiation over self-priming adhesive, added composite resin was irradiated for 3, 6, or 12 sec with ultra-high intensity light. After bonded specimens were stored in 37$^{\circ}C$ distilled water for 24 hours, shear bond strength were measured using a universal testing machine (4202, Instron, Instron Co., U.S.A.) and fractured surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan). Statistical analysis were done with one-way, two-way ANOVA and chi-square test. The results were as follows : 1. The shear bond strengths from the groups irradiated over self-priming adhesive were significantly higher than those from the groups without irradiation (p<0.05). 2. There was no significant shear bond strength difference between regular intensity light irradiation groups and ultra-high intensity ones (p>0.05). 3. There was no significant shear bond strength difference among various irradiation time groups with ultra-high intensity ones (p>0.05). 4. In stereomicroscopic examination of fractured surfaces, adhesive-cohesive mixed failure mode was mostly seen in all groups, and there was no significant difference in failure mode among groups (p>0.05).

  • PDF

APPLICATION OF ACIDIC PRIMER FOR ORTHODONTIC ADHESIVE SYSTEM (Acidic primer를 이용한 교정용 브라켓 접착의 전단결합강도)

  • Kim, Jin-Hee;Jin, Hun-Hee;Oh, Jang-Kyun
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.137-147
    • /
    • 2001
  • Acidic primer is the bonding agent which combines the conditioning and priming agent into the single solution and was originally developed for the dentin bonding system. It is less harmful to the tooth structure and more convenient to manipulate than the traditional etching procedure. The Purpose of this study is to evaluate the shear bond strength of various bonding materials when the enamel is treated with acidic primer for the bracket bonding procedure. Fifty recently extracted human premolars were randomly separated into five groups -Group I using Clearfil Liner Bond 2 adhesive system to the enamel treated with acidic primer, Group II using Transbond XT adhesive system to the enamel treated with acidic primer, Group III using panavia 21 adhesive system to the enamel treated with acidic primer, Group IV using Fuji-Ortho LC adhesive system to the enamel treated with acidic primer, Group V using Transbond XT adhesive system to the enamel treated with 37$\%$ phosphoric acid. The shear bond strength was measured with Instron universal testing machine after storing in $37^{\circ}C$ water bath for 48 hours. After debonding, the teeth and brackets were examined under scanning electron microscope (SEM) and assessed with the adhesive remnant index (ARI). The results were as follows : 1. There were no significant differences in shear bond strength between group III ($8.69{\pm}2.72MPa$), group IV (9.7 ± 3.16 MPa), and group V ($10.48{\pm}2.60MPa$) (p>0.05). 2. The shear bond strength of group III and group IV was significantly higher than that of group I ($1.09{\pm}0.53MPa$), and Group II ($2.70{\pm}1.46MPa$) (p<0.05). 3. The ARI of group IV ($2.1{\pm}1.1$) and group V ($2.9{\pm}0.3$) was significantly higher than that of group I ($0.2{\pm}0.4$), group II ($0.3{\pm}0.9$) and group III ($0.2{\pm}0.4$) (p<0.05). 4. There were no significant difference between the ARI of group IV and group V (p>0.05). This result suggests that the combination of acidic primer and some bonding adhesive can provide sufficient shear bond strength for clinical orthodontics.

  • PDF

Influence of NO3-:NH4+ Ratios in Fertilizer Solution on Growth and Yield of Hot Pepper (Capsicum annuum L.) in Pot Cultivation (배지경 포트재배에서 비료용액의 NO3-:NH4+ 비율이 고추의 생장 및 수량에 미치는 영향)

  • Yi, Ho Jin;Choi, Jong Myung;Jang, Sung Wan;Jung, Suk Ki
    • Horticultural Science & Technology
    • /
    • v.31 no.1
    • /
    • pp.65-71
    • /
    • 2013
  • This research was conducted to evaluate the influence of $NO_3{^-}:NH_4{^+}$ ratios in fertilizer solution on the vegetative growth and fruit yield of hot pepper (Capsicum annuum L.) through pot cultivation. The Hoaglad's solution was modified to contain various $NO_3{^-}:NH_4{^+}$ ratios such as 100:0 (A), 73:37 (B), 50:50 (C), 27:73 (D), 0:100 (E), and no nitrogen (F). Plants were transplanted into root substrates and the modified solutions were applied as plant needed in plastic house. There were no statistical significances among the treatments from A through D in the fresh and dry weights, and number of leaves 31 days after transplanting, but elevation of $NH_4{^+}$ ratios in the solution decreased the fresh fruit weight 62 days after transplanting with statistical differences. In the results of inorganic element analysis based on the dry weight of fully expanded mature leaves, N and P contents as well as micro cations such as Fe, Mn, Zn, and Cu increased as $NH_4{^+}$ ratios were elevated 62 days after transplanting. However, those of macro cations such as K, Ca, and Mg resulted in decreasing tendency. The elevation of $NH_4{^+}$ ratios in fertilizer solution resulted in the increase of EC and total N concentrations ($NO_3{^-}+NH_4{^+}$), but this decreased the pH as well as Ca and Mg concentrations in soil solution 62 days after transplanting. The K concentration in soil solution was the highest in the treatments of C and followed by D, B, E, and A. The above results indicate that the proper $NO_3{^-}:NH_4{^+}$ ratio in the nutrient solution is 73:27 (B) or 100:0 (A) and the B solution is proper for the vegetative growth and that of A is proper for reproductive growth stage.

Effects of Foliar Application of CaCl2 on Ca Content and Occurrence and Alleviation of Blossom-end Rot of Paprika During High Temperature Season (고온기 CaCl2 엽면 살포가 파프리카 칼슘함량, 배꼽썩음과 발생과 경감에 미치는 영향)

  • Oh, Jeong Sim;Lee, Yong-Beom;Bae, Jong Hyang;Na, Jong Kuk;Choi, Ki Young
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.263-270
    • /
    • 2021
  • This experiment was carried out to determine the effect of CaCl2 foliar spraying on the inhibition of blossom-end rot (BER) in hot summer paprika (Capsicum annum L. 'Special') cultivation. The effect of CaCl2 application was examined by the foliar application based on different fruit size, frequency, and spraying time. Also, it was investigated the occurrence and alleviation effect of BER symptom. Foliar application of CaCl2 (Ca 0.4%) was conducted by treating a fruit and leaf at 4 to 9 nodes above the crown flowers of each plant with 350 mL per week from June 3 to July 1. When the CaCl2 was sprayed at 7-day intervals for 4 weeks, the Ca content was the lowest in the fruit harvested with BER symptom in 11 to 20 mm of fruit width (FW). Four different regions in both BER symptom and normal fruits showed significant differences of Ca content, the highest was in pedicel, followed by stem-end, middle, and blossom-end. The Ca content increased sharply in normal paprika with 31-40 mm FW, in which Ca content was 78% higher than that of BER. Ca content in the middle and blossom-end of paprika over 21 mm in FW ranged 19.8% to 28.8% in normal fruits and 15.7% to 18.5% in BER, respectively. The incidence of BER increased rapidly by more than 60% in fruits with 31-40 mm FW. While there was no difference in fruit weight among the FW treatment, marketable yield rate was highest in the 21-30 mm FW, and the sugar content was high in the 11-30mm FW. When CaCl2 was applied three times for 7 days to a paprika having a 21- 30 mm FW, the cell wall-bound (CWB) Ca content was the highest and the rate of BER was lowest with 6.3%. After 10 days of CaCl2 foliar spray treatment, the CWB Ca content of paprika increased by 2.9 to 3.5 times compared to the control in all treatments. At 7 days after the CaCl2 foliar spraying once a day at varying spraying time, the leaf burn observed from 9:30 a.m. to 17:00 p.m. and the proline content increased as the spraying time was delayed. Therefore, the CaCl2 foliar spraying method for reducing of BER occurrence during paprika summer cultivation seems to be appropriate to spray 2-3 times at intervals of 3 days and before 8 a.m. at the time when the FW is 21-30 mm.

3-D Finite element stress analysis in screw-type, cement-type, and combined-type implant fixed partial denture designs (임플란트 상부보철물의 유지형태에 따른 3차원 유한요소 응력분석)

  • Lee, Sung-Chun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.365-375
    • /
    • 2009
  • Statement of problems: Stress analysis on implant components of the combined screw- and cement-retained implant prosthesis has not investigated yet. Purpose: The purpose of this study was to assess the load distribution characteristics of implant prostheses with the different prosthodontic retention types, such as cement-type, screw-type and combined type by using 3-dimensional finite element analysis. Material and methods: A 3-dimensional finite element model was created in which two SS II implants (Osstem Co. Ltd.) were placed in the areas of the first premolar and the first molar in the mandible, and three-unit fixed partial dentures with four different retention types were fabricated on the two SS II implants. Model 1 was a cement-retained implant restoration made on two cement-retained type abutments (Comocta abutment; Osstem Co. Ltd.), and Model 2 was a screw-retained implant restoration made on the screw-retained type abutments (Octa abutment; Osstem Co. Ltd.). Model 3 was a combined type implant restoration made on the cement-retained type abutment (Comocta abutment) for the first molar and the screw-retained type abutment (Octa abutment) for the first premolar. Lastly, Model 4 was a combined type implant restoration made on the screw-retained type abutment (Octa abutment) for the first molar and the cement-retained type abutment (Comocta abutment) for the first premolar. Average masticatory force was applied on the central fossa in a vertical direction, and on the buccal cusp in a vertical and oblique direction for each model. Von-Mises stress patterns on alveolar bone, implant body, abutment, abutment screw, and prosthetic screw around implant prostheses were evaluated through 3-dimensional finite element analysis. Results: Model 2 showed the lowest von Mises stress. In all models, the von Mises stress distribution of cortical bone, cancellous bone and implant body showed the similar pattern. Regardless of loading conditions and type of abutment system, the stress of bone was concentrated on the cortical bone. The von-Mises stress on abutment, abutment screw, and prosthetic screw showed the lower values for the screw-retained type abutment than for the cement-retained type abutment regardless of the model type. There was little reciprocal effect of the abutment system between the molar and the premolar position. For all models, buccal cusp oblique loading caused the largest stress, followed by buccal cusp vertical loading and center vertical loading. Conclusion: Within the limitation of the FEA study, the combined type implant prosthesis did not demonstrate more stress around implant components than the cement type implant prosthesis. Under the assumption of ideal passive fit, the screw-type implant prosthesis showed the east stress around implant components.