• Title/Summary/Keyword: 착과

Search Result 918, Processing Time 0.034 seconds

BONDING OF RESIN INLAY TO GLASS-IONOMER BASE WITH VARIOUS TREATMENTS ON INLAY SURFACE (내표면 처리에 따른 레진 인레이와 글래스아이오노머 베이스간의 접착)

  • Jang, Byung-Sung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.399-406
    • /
    • 2000
  • The effect of inlay surface treatment on bonding was investigated when resin inlay was bonded to resin-modified glass-ionomer base with resin cement. For the preparation of glass-ionomer base, resin-modified glass-ionomer cement (Fuji II LC, GC Co., Japan) was filled in class I cavities of 7mm in diameter and 2mm in depth made in plastic molds. Eighty eight resin inlay specimens were made with Charisma$^{(R)}$ (Kulzer, Germany) and then randomly assigned to the four different surface treatment conditions: Group I, $50{\mu}m$ aluminium oxide sandblasting and silane treatment ; Group II, silane treatment alone ; Group III, sandblasting alone, and Group IV (control), no surface treatment. After a dentin bonding agent with primer (One-Step$^{TM}$, Bisco Inc., IL., U.S.A.) was applied to bonding surface of resin inlay and base, resin inlay were cemented to glass-ionomer base with a resin cement (Choice$^{TM}$, Bisco Inc., IL., U.S.A.). Shear bond strengths of each specimens were measured using Instron universal testing machine (4202 Instron, lnstron Co., U.S.A.) and fractured surfaces were examined under the stereoscope. Statistical analysis was done with one-way ANOVA and Dunkan's multiple range test. The results were as follows: 1. Sandblasting and silane treatment provided the greatest bond strength(10.56${\pm}$1.95 MPa), and showed a significantly greater bond strength than sandblasting alone or no treatment (p<0.05). 2. Silane treatment provided a significantly greater bond strength(9.77${\pm}$2.04 MPa) than sandblasting alone or no treatment (p<0.05). However, there was no significant difference in bond strength between sandblasting treatment and silane one (p>0.05). 3. Sandblasting alone provided no significant difference in bond strength from no treatment (p>0.05). 4. Stereoscopic examination of fractured surface showed that sandblasting and silane treatment or silane treatment alone had more cohesive failure mode than adhesive failure mode. 5. In relationship between shear bond strength and failure mode, cohesive failure occurred more frequently as bond strength increased.

  • PDF

APPLICATION OF ACIDIC PRIMER FOR ORTHODONTIC ADHESIVE SYSTEM (Acidic primer를 이용한 교정용 브라켓 접착의 전단결합강도)

  • Kim, Jin-Hee;Jin, Hun-Hee;Oh, Jang-Kyun
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.137-147
    • /
    • 2001
  • Acidic primer is the bonding agent which combines the conditioning and priming agent into the single solution and was originally developed for the dentin bonding system. It is less harmful to the tooth structure and more convenient to manipulate than the traditional etching procedure. The Purpose of this study is to evaluate the shear bond strength of various bonding materials when the enamel is treated with acidic primer for the bracket bonding procedure. Fifty recently extracted human premolars were randomly separated into five groups -Group I using Clearfil Liner Bond 2 adhesive system to the enamel treated with acidic primer, Group II using Transbond XT adhesive system to the enamel treated with acidic primer, Group III using panavia 21 adhesive system to the enamel treated with acidic primer, Group IV using Fuji-Ortho LC adhesive system to the enamel treated with acidic primer, Group V using Transbond XT adhesive system to the enamel treated with 37$\%$ phosphoric acid. The shear bond strength was measured with Instron universal testing machine after storing in $37^{\circ}C$ water bath for 48 hours. After debonding, the teeth and brackets were examined under scanning electron microscope (SEM) and assessed with the adhesive remnant index (ARI). The results were as follows : 1. There were no significant differences in shear bond strength between group III ($8.69{\pm}2.72MPa$), group IV (9.7 ± 3.16 MPa), and group V ($10.48{\pm}2.60MPa$) (p>0.05). 2. The shear bond strength of group III and group IV was significantly higher than that of group I ($1.09{\pm}0.53MPa$), and Group II ($2.70{\pm}1.46MPa$) (p<0.05). 3. The ARI of group IV ($2.1{\pm}1.1$) and group V ($2.9{\pm}0.3$) was significantly higher than that of group I ($0.2{\pm}0.4$), group II ($0.3{\pm}0.9$) and group III ($0.2{\pm}0.4$) (p<0.05). 4. There were no significant difference between the ARI of group IV and group V (p>0.05). This result suggests that the combination of acidic primer and some bonding adhesive can provide sufficient shear bond strength for clinical orthodontics.

  • PDF

EFFECT OF APF GEL ON THE SURFACE OF COMPOSITE RESIN (복합레진 표면에 대한 APF gel의 영향)

  • Yuk, Gun-Yeung;Yang, Kyu-Ho;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.43-52
    • /
    • 2006
  • Topical fluoride application for children is a widely peformed procedure in the field of pediatric dentistry to prevent dental caries. However, it is recently recognized as having some unwanted effects on several esthetic restorative materials as it roughens the surface of the restorative materials. The aim of this study was to evaluate the surface changes in composite resins to topical fluoride. Composite resins(Z $250^{(R)}$, Ultraseal $XT^{(R)}$ Filtek $flow^{(R)}$ $Revolution^{(R)}$, $Denfil^{(R)}$) in topical fluoride agents were immersed and their surface roughness, weight loss and SEM were evaluated. The results were as follows : 1. The 4 minutes-immersion groups showed more roughened surface than 1 minute-immersion groups and the control groups showed the smoothest surface among all the materials, and there was statistically significant difference except the revolution between the groups. 2. There was no significant difference between the 1 minute-immersion groups and 4 minutes-immersion groups in weight loss. 3. The experimental group treated with topical fluoride gel showed the generally mere roughened surface than control group in the SEM findings.

  • PDF

The Subjective Estimation on the Ensemble and Comfort of Workers Wearing winter Uniform in Taegu (대구지역 동계 제복 근무자의 피복 착의 앙상블과 쾌적성의 주관적 평가)

  • Ryu, Duck-Hwan;Lee, Uk-Ja;Kim, Seong-Jin;Song, Min-Kyu;Cho, Ji-Hyun;Jung, Meung-Sun
    • Fashion & Textile Research Journal
    • /
    • v.2 no.3
    • /
    • pp.253-264
    • /
    • 2000
  • The purpose of this study was to examine the thermal comfort characteristics of the garments for school, textile and bank worker's uniform. The garments selected for this study were frequently used in Taegu area in terms of design and material used for making garments by the survey for the study The human subject tests were performed to determine the thermal comfort characteristics of garments including thermal, humidity, and wearing sensation and the data were analysed statistically. The results of the study were as follows: 1. According to the result of the survey jacket was mostly used as a school uniform for both male and female high school students. The survey showed that 93% of male students wore 'neck T-shirts' and dimensional fitness for the school uniform got suitable at 2~3 grade high school students. In terms of human subject tests, most students rated 'uncomfortable' in wearing sensation of their school uniform. One of this reason was due to the humidity sensation and air velocity sensation. Level of significance of the thermal sensation for gender difference was higher in hands and feet of the subjects than in chest and thigh of them. 2. According to the result of the survey jacket with zipper was mostly used as a textile worker's uniform. The result of the survey indicated that some textile workers are wearing their inner wear (38.7% for upper and 46.6% for lower). In the human subject tests, about 50% of subjects rated 'comfortable to slightly comfortable' for wearing sensation of the textile worker's uniform. It showed that the female subjects of the humidity sensation was rated higher than the male subjects of the humidity sensation, while the male subjects of the thermal sensation was rated higher than the female subjects of the thermal sensation. There was a closer correlation with the subjective thermal sensation for textile worker's uniform in center parts of the subjects such as back and waist than exposed parts. 3. The result of the survey showed that 70% and 23% of the female banker uniform were blouse and jacket, respectively and 75% and 25% of the male banker uniform were jacket and T-shirt, respectively. All interviewee rated trousers and skirts that were used for their lower. 4. The result indicated that 50% male and 67.7% female subjects for the banker uniform rated 'slightly comfortable for the comfort' sensation. 50% male subjects rated 'neutral' and about 50% female subjects rated 'slightly warm to neutral' for the thermal sensation. In addition, The result showed that 75% male subjects for both upper and lower rated 'neutral' for the humidity sensation and also 75% female subjects rated 'neutral to slightly dry'. Thus, there was no significant different between gender. 5. In the thermal sensation of the subjects for the banker's uniform by parts, 50% subjects rated 'neutral' for their body parts, including head, neck, back, waist, hip, lower arm, and thigh. The extremely cold parts were hands and feet for both male and female subjects.

  • PDF

HVL Measurement of the Miniature X-Ray Tube Using Diode Detector (다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정)

  • Kim, Ju-Hye;An, So-Hyeon;Oh, Yoon-Jin;Ji, Yoon-Seo;Huh, Jang-Yong;Kang, Chang-Mu;Suh, Hyunsuk;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • The X ray has been widely used in both diagnosis and treatment. Recently, a miniature X ray tube has been developed for radiotherapy. The miniature X ray tube is directly inserted into the body irradiated, so that X rays can be guided to a target at various incident angles according to collimator geometry and, thus, minimize patient dose. If such features of the miniature X ray tube can be applied to development of X ray imaging as well as radiation treatment, it is expected to open a new chapter in the field of diagnostic X ray. However, the miniature X ray tube requires an added filter and a collimator for diagnostic purpose because it was designed for radiotherapy. Therefore, a collimator and an added filter were manufactured for the miniature X ray tube, and mounted on. In this study, we evaluated beam characteristics of the miniature X ray tube for diagnostic X ray system and accuracy of measuring the HVL. We used the Si PIN Photodiode type Piranha detector (Piranha, RTI, Sweden) and estimated the HVL of the miniature X ray tube with added filter and without added filter. Through an another measurement using Al filter, we evaluated the accuracy of the HVL obtained from a direct measurement using the automatic HVL calculation function provided by the Piranha detector. As a result, the HVL of the miniature X ray tube was increased around 1.9 times with the added filter mounted on. So we demonstrated that the HVL was suitable for diagnostic X ray system. In the case that the added filter was not mounted on, the HVL obtained from use of the automatic HVL calculation function provided by Piranha detector was 50% higher than the HVL estimated using Al filter. Therefore, the HVL automatic measurement from the Piranha detector cannot be used for the HVL calculation. However, when the added filter was mounted on, the HVL automatic measurement value using the Piranha detector was approximately 15% lower than the estimated value using Al filter. It implies that the HVL automatic measurement can be used to estimate the HVL of the miniature X ray tube with the added filter mounted on without a more complicated measurement method using Al filter. It is expected that the automatic HVL measurement provided by the Piranha detector enables to make kV-X ray characterization easier.

Growth and Fruit Characteristics of Vitis amurensis Rupr. Collected in Gangwondo (강원도에서 수집된 왕머루의 생장과 과실특성)

  • Park, Young-Sik;Heo, Jae-Yun;Kim, In-Jong;Heo, Su-Jeong;Kim, Kyung-Hee;Jeong, Byung-Chan;Park, Sung-Min
    • Korean Journal of Medicinal Crop Science
    • /
    • v.13 no.6
    • /
    • pp.226-233
    • /
    • 2005
  • This study was carried out to evaluate the fruit and growth characteristics of selecting Vitis amurensis through functional material analysis and sensory evaluation in V. amurensis collected in Gangwondo. For evaluation of growth characteristics in V. amurensis, experiments were carried out by compared with the two grape cultivars 'Campbell Early' and 'Kyoho'. The full bloom and verasion time in V. amurensis was investigated faster than those of examined cultivar grapes, while harvest time was investigated latter than those of examined cultivar grapes, but agronomic characteristics was not thought significantly difference between cultivar grapes and V. amurensis. For evaluation of shoot growth phase, the growth curve was very similar to cultivar grapes. The berry size in V. amurensis showed that increases rapidly between 3 and 4 days after full bloom time, and approximately doubles between the second growth period and harvest time, and the berry development phase investigated that consist of two sigmoid growth periods separated by a lag phase. The berry weight and soluble solids in V. amurensis increased with the tree age, but acidity and total sugar contents decreased, and showed a special quality and stable growth according to vine age. To investigation of functional materials, the anthocyanin content in V. amurensis ranged from 16.6 to 50.2 mg/100 g, and the resveratrol content ranged from 0.143 to $0.236{\mu}g/100\;g$ which was higher than those of cultivar grapes. These result indicated that V. amurensis tended to have the useful material larger than cultivar grapes. Therefore, other edibility factors of V. amurensis collected in Gangwondo may contribute to breeding studies in Vitis. spp.

A Study on a Quantified Structure Simulation Technique for Product Design Based on Augmented Reality (제품 디자인을 위한 증강현실 기반 정량구조 시뮬레이션 기법에 대한 연구)

  • Lee, Woo-Hun
    • Archives of design research
    • /
    • v.18 no.3 s.61
    • /
    • pp.85-94
    • /
    • 2005
  • Most of product designers use 3D CAD system as a inevitable design tool nowadays and many new products are developed through a concurrent engineering process. However, it is very difficult for novice designers to get the sense of reality from modeling objects shown in the computer screens. Such a intangibility problem comes from the lack of haptic interactions and contextual information about the real space because designers tend to do 3D modeling works only in a virtual space of 3D CAD system. To address this problem, this research investigate the possibility of a interactive quantified structure simulation for product design using AR(augmented reality) which can register a 3D CAD modeling object on the real space. We built a quantified structure simulation system based on AR and conducted a series of experiments to measure how accurately human perceive and adjust the size of virtual objects under varied experimental conditions in the AR environment. The experiment participants adjusted a virtual cube to a reference real cube within 1.3% relative error(5.3% relative StDev). The results gave the strong evidence that the participants can perceive the size of a virtual object very accurately. Furthermore, we found that it is easier to perceive the size of a virtual object in the condition of presenting plenty of real reference objects than few reference objects, and using LCD panel than HMD. We tried to apply the simulation system to identify preference characteristics for the appearance design of a home-service robot as a case study which explores the potential application of the system. There were significant variances in participants' preferred characteristics about robot appearance and that was supposed to come from the lack of typicality of robot image. Then, several characteristic groups were segmented by duster analysis. On the other hand, it was interesting finding that participants have significantly different preference characteristics between robot with arm and armless robot and there was a very strong correlation between the height of robot and arm length as a human body.

  • PDF

Influence of the curing time for the adhesive on the oxygen-inhibited layer thickness and the shear bond strength to dentin (광조사 시간이 접착제의 표면 미중합층의 두께와 전단접착강도에 미치는 영향에 관한 연구)

  • Choi, Yong-Hoon;Bae, Ji-Hyun;Son, Ho-Hyun;Lee, In-Bog;Um, Chung-Moon;Baek, Seung-Ho;Kim, Oh-Young;Kim, Chang-Keun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.177-184
    • /
    • 2004
  • Objectives : This study investigated the hypothesis that increasing light-curing time would leave the oxygen-inhibited layer (OIL) of the adhesive thinner, and in turn, result in lower shear bond strength (SBS) than those obtained by the routine curing procedures. Methods:120 human extracted posterior teeth were randomly divided into three groups for bonding with three adhesives:All Bond 2/sup (R)/, One Step/sup (R)/, and Adper Prompt/sup (R)/. They were subsequently divided into four subgourps with different light-curing time (10, 20, 30 and 60s). The assigned adhesives were applied on superficial occlusal dentin according to the manufacturer's instructions and cured with one of the four curing times. Composite resin cylinder, 2.35㎜ in diameter, were built on the cured adhesive and light-cured for 40s. SBS were measured after 24h from the bonding using a universal testing machine (crosshead speed 1.0 ㎜/min). The relative thickness of the OIL and the degree of conversion (DC) were determined from the adhesive on a slide glass using FT-NIR in an absorbance mode. Data were analysed with One-way ANOVA and Duncan's multiple test (p〈0.05), Results:With increasing cure time, although there were no significant difference in th SBS of One-step and Adper Prompt (p〉0.05), those of All Bond 2 decreased significantly (p〈0.05). The relative thicknesses of the OIL on each adhesive were not affected by the cure time (p〉0.05). Although the DC of All-Bond 2 were statistically not different with increasing cure time (p〉0.05), those of One-Step and Adper Prompt showed an increasing trends with increasing cure time (p〈0.05). Conclusions:Increasing light-curing time did not affect on the relative thickness of the OIL of the adhesives, and in turn, on the SBS to dentin.

Pulmonary Arterial Growth Pattern after Shunt Operation in Patients of Pulmonary Atresia with Ventricular Septal Defect Associated with Juxtaductal Stenosis (Juxtaductal stenosis가 동반된 PA/VSD환자에서 체폐단락술 부위에 따른 폐동맥 크기의 변화)

  • 이교준;박영환;최재영;조범구
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.861-866
    • /
    • 1998
  • Background: Pulmonary atresia (PA) with ventricular septal defect has various morphology of pulmonary arteries and pulmonary blood flow sources, so pulmonary arterial hypoplasia and arborization abnormality make this anomaly difficult to manage surgically. In cases associated with juxtaductal stenosis, we evaluated the change of the pulmonary arterial and juxtaductal stenotic site after shunt operations, and would like to find useful information in surgical planning and methodology of these patients. Material and Method: Among 59 cases diagnosed as PA with ventricular septal defect associated with juxtaductal stenosis, 29 cases who had cardiac catheterization before and after shunt operation were selected from July, 1991 to July, 1996. In 10 cases of right shunt operation(Group I) and 19 cases of left shunt operation (Group II), the diameters of the descending aorta, both pulmonary arteries, and the juxtaductal stenosis site were measured before and after the shunt operation. Result: In both Group I and II, the pre- and postoperative ratio of diameters of the ipsilateral pulmonary artery to the descending aorta was from 0.78${\pm}$0.31 units to 1.01${\pm}$0.26 units and from 0.67${\pm}$0.18 units to 0.84${\pm}$0.27 units respectively, showing a signigicant increase. The contralateral pulmonary artery index was increased from 0.92${\pm}$0.28 units to 1.05${\pm}$0.15 units and from 0.94${\pm}$0.27 units to 1.08${\pm}$0.37 units respectively, but could not be confirmed statistically. In both groups, the change of juxtaductal stenosis showed an aggravating tendency but of no statistical significance from 0.43${\pm}$0.27 units to 0.39${\pm}$0.25 units and from 0.32${\pm}$0.10 units to 0.30${\pm}$0.16 units respectively, and we experienced 2 total obstruction in Group II. Because the increased pulmonary blood flow by shunt operation has a favorable effect to the pulmonary arterial growth, the shunt operation is a recommended treatment in patients with hypoplastic pulmonary arteries. But in PA with ventricular septal defects, the change of juxtaductal stenosis is very important. In conclusion, the growth of ipsilateral (shunt site) pulmonary artery was promoted by shunt operation, but there is a tendency for the juxtaductal stenosis to be aggravated. And we experienced 2 total obstruction in Group II. Conclusion: Thus, in cases operated with shunt method, much careful postoperative follow up study including angiographic evaluation is needed, and after the shunt operation on the side of pulmonary artery associated with juxtaductal stenosis, early precise planning for total correction is recommended.

  • PDF

Surgical Treatment of Left Main Coronary Artery Diseases (좌주관동맥협착의 외과적 치료)

  • 안병희;장원채
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1323-1328
    • /
    • 1996
  • The obstructive diseases involving the left main coronary artery(LMCA) are serious. Surgical treatment is generally regarded as much more effective than medical therapy in terms of long-term survival and relief of symptoms. This study represents an attempt to present an analysis of early surgical results in 21 cases conducted at Chonnam University Hospital between October 1992 And August 1995. The subject. 12 males and 9 female, ranged in age from 25 to 67 years with a mean age of 49.3${\pm}$12.5 years. As for indications for operation, unstable angina was reported on 66.7% of the subjects, while stable angina and acute myocardial infarction in 4 and 3 cases, respectively. There were also 2 cases of Takayasu's aortitis and 1 case of failed percutaneous translumlnal coronary angioplasty(PTCA). Eleven subjects had isolated LMCA diseases compared to 10 subjects with associated LMCA diseases. Of the patients with ass;3ciated LMCA diseases, 4 subjects had single coronary artery disease, 3 had double coronary artery disease, remaining 3 suffered from triple coronary artery disease. As for the group with isolated LMCA disease, ostidl angioplasty llsing autopericardium was conducted with 5 subjects. The remaining subjects with the isolated diseases and all of the patients with associated LMCA disease underwent aortocoronary bypass grafts. The left internal mammary artery was used in all patients and the average number of anastomoses was 3.13 ${\pm}$0.93. One subject died of low cardiac output syndrome at the second postoperative day. There were 5 instances of postoperative complication including reoperation for bleeding in two patients, wound infection in two, and arrhythmia in one. Follow-up coronary angiogram were conducted with eights patients, including five patients who underwent ostial angioplasty. In these cases, the patients showed surf. ficient enlargement of the left coronary ostium and the grafted vessels kept their patency. In our experience, surgical treatment of the LMCA diseases has not shown a higher rAte of operative mortAlity or morbidity than other obstructive coronary artery diseases. To patients with ostial stenosis, which is frequently observed among young female, angioplasly utilizing autopericardium seems to be a desirable choice considering the cosmetic effect, chances of reoperation and hemodynamic characteristics.

  • PDF