• 제목/요약/키워드: 차폐체

Search Result 326, Processing Time 0.023 seconds

Design Study of A Spent Fuel Shipping Cask for Korea Nuclear Unit-1 (고리 1호기의 기사용 핵연료 집합체 수송용기 설계에 관한 연구)

  • Moo Han Kim;Chang Sun Kang
    • Nuclear Engineering and Technology
    • /
    • v.14 no.4
    • /
    • pp.196-203
    • /
    • 1982
  • To transport the spent fuel assemblies of Korea Nuclear Unit 1, which is a Westinghouse type two loop pressurized water reactor, it has been found that steel is the most appropriate material for the design of a shipping cask in comparison with lead and depleted uranium. The proposed shipping cask will transport nine fuel assemblies at the same time and is well within the weight limit of transportation by unrestricted rail car. The cask requires 33cm thick steel shield and 27cm thick water region to satisfy the 3 feet apart dose rate limit set forth in 10 CFR 71, and 1.27cm thick steel boron fuel basket to hold the fuel elements inside the cask and control the effective multiplication factor. As a safety analysis, the fuel cladding and centerline temperatures were calculated under the accident condition of complete loss of water coolant, and it was found that the temperature was much lower than the limit of the melting point. k$_{eff}$ was calculated with fresh fuel assemblies, which was found to be well lower than 0.95. For shielding computation, the multipurpose Monte Carlo code MORSE-CG and one dimensional discrete ordinates transport code ANISN were used, and the Monte Carlo codes KENO and MORSE-CG were used for criticality calculation. The radiation source terms were calculated using ORIGEN-79.9.

  • PDF

The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy (인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가)

  • Kim, Jong Wook;Woo, Heon;Jeong, Hyeon Hak;Kim, Kyeong Ah;Kim, Chan Yong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.329-336
    • /
    • 2014
  • Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.

Conceptual Design of Multi-Functional Structure using Rectangular Grid-Stiffened Structure for Satellite (위성용 사각형 격자강화 구조의 다기능 구조체 개념설계)

  • Seo, Hyun-Suk;Jang, Tae-Seong;Rhee, Ju-Hun;Kim, Won-Seock;Hyun, Bum-Seok;Lim, Jae-Hyuk;Hwang, Do-Soon;Lee, Sang-Kon;Cho, Hee-Keun;Han, Eun-Soo;Kim, Im-Soo;Sim, Eun-Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.6
    • /
    • pp.526-534
    • /
    • 2011
  • The MFS (Mlti-Functional Structure) concept, which integrates the electronics, thermal control and structure into a single packaging system, has been developed and applied to reduce the volume and weight of the satellite. Therefore, this MFS can eliminate the bulky chassis/frames, cables and connectors of the electronic equipment. The main point of this traditional MFS is the replacement of the electrical chassis/frames with MCMs (Multi-Chip Modules) that require much costs and efforts for developing. This paper shows the new MFS concept that effectively saves the volume and weight. The structure including the thermal control and radiation shielding elements will be designed and manufactured as the rectangular grid-stiffened structure. The rectangular grid-stiffened structure is the modification of the iso-grid structure, and provides the enough spaces for putting the general PCBs without the chassis/frames.

Dispersion Characteristics of Magnetic Particle/Graphene Hybrid Based on Dispersant and Electromagnetic Interference Shielding Characteristics of Composites (분산제에 따른 자성금속 무전해도금 기반 그래핀 분산 특성 및 복합재의 전자파 차폐 특성 연구)

  • Lee, Kyunbae;Lee, Junsik;Jung, Byung Mun;Lee, Sang Bok;Kim, Taehoon
    • Composites Research
    • /
    • v.31 no.3
    • /
    • pp.111-116
    • /
    • 2018
  • In this paper, magnetic FeCoNi particles have been grown through electroless plating on the surface of graphene, and then this hybrid material has been dispersed by various surfactants to prepare films. The pyridine surfactant shows the highest dispersability and low surface resistance value (351 Ohm/sq) and the electromagnetic shielding ability at the frequency of 10 GHz. Specially, the evaporation of the pyridine during the drying process could be able to form the internal conductive network and high dispersion of FeCoNi on the surface of graphene.

Preparation of Jam Using Undaria pinnatifida Sporophyll (미역귀를 이용한 잼의 제조)

  • 김선재;문지숙;김정목;강성국;정순택
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.3
    • /
    • pp.598-602
    • /
    • 2004
  • In the preparation of jam using Undaria pinnatifida sporophyll, effects of food ingredients to the jam rheology were investigated. The paste was prepared by crushing the sporophyll using chopper and homogenizer with 2.5 times water and then it was filtrated before to make a jam. The sporophyll jam was adjusted to 62$^{\circ}$Brix by heating and concentration. It was a similar to the commercial jam in the gel strength. Among the various treatments, the jam prepared with 60% (w/w) sugar, 0.75% (w/w) high methoxy (HM) pectin and 0.3% (w/w) citric acid showed best quality aspects of both texture profile analysis (TPA) and sensory evaluation. Addition of 0,08% (v/w) synthetic strawberry flavor and 0.5% (w/w) cinnamon powder to sporophyll paste gave a good masking effect for the undesirable sea mustard flavor.

Development of Prototype Liquid Scintillator System for Monitoring Liquid Radioactive Waste (배수 모니터링 액체섬광검출시스템의 프로토 타입 개발)

  • Nam, Uk-Won;Seon, Kwang-Il;Kong, Kyoung-Nam;Kim, Chang-Kyu;Lee, Dong-Myung;Lee, Sang-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.173-182
    • /
    • 2003
  • A prototype liquid scillatillator system for measurement of multiple beta-labeled mixtures was developed and its characteristic was investigated. The signal processing system consists of two photomultiplier tubes and the coincident count circuit. The characteristic of the system was analyzed using 4 beta-labeled samples $(^3H,\;^{14}C,\;^{36}Cl\;and\;^{90}Sr)$. Beta spectra from the samples were obtained without radiation shielding, and the detection limits for each nuclides were estimated based on the spectra. The estimated detection limits were compared to the legal regulation values. It is found that the liquid radioactive nuclides are detectable well below the legal regulation values.

Fast Neutron Flux Determination by Using Ex-vessel Dosimetry (노외 감시자를 이용한 압력용기 중성자 조사량 결정)

  • Yoo, Choon-Sung;Park, Jong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.158-167
    • /
    • 2007
  • It is required that the neutron dosimetry be present to monitor the reactor vessel throughout its plant life. The Ex-vessel Neutron Dosimetry Systems which consist of sensor sets, radiometric monitors, gradient chains, and support hardware have been installed for 3-Loop plants after a complete withdrawal of all six in-vessel surveillance capsules. The systems have been installed in the reactor cavity annulus in order to characterize the neutron energy spectrum over the beltline region of the reactor vessel. The installed dosimetry were withdrawn and evaluated after a irradiation during one cycle and then compared to the cycle specific neutron transport calculations. The reaction rates from the measurement and calculation were compared and the results show good agreements each other.

Study on the Between the Grounding Resistance and Grounding Electrode using Mesh Grounding Electrodes and a Shielding Panel (메쉬접지전극과 차폐패넬을 이용한 접지저항 및 접지전극간의 영향에 관한 연구)

  • Leeg, Chung-sik;Cho, Moon-taek;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.3
    • /
    • pp.230-236
    • /
    • 2015
  • In this paper, the electric potential of electrode surface is investigated by assuming them as two dimensional sets of point current sources. And, the simulated water tank is manufactured as a reduced scale of the earth. Henceforth, the adequate model electrode for test is decided to decrease experimental errors relevant to the limitation of the size of the water tank. The one of important things of this work, the deduction method of the potential interference factor is proposed, which used as the criterion of the potential interference according to the shape of conductors and the laying conditions, when multiple grounding conductors are situated at the same resistance grounding area. Also, the validity of this theory is verified from a numerical simulation of the grounding electrode to be used in experiments, and this study is realized by the verified theory and the simulated experiments.

Electromagnetic wave shielding effectiveness of steel fiber reinforced concrete (강섬유 보강 콘크리트의 전자파 차폐효과)

  • Lee, Gyu-Phil;Chang, Soo-Ho;Choi, Soon-Wook;Bae, Gyu-Jin;Park, Young-Taek
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.107-115
    • /
    • 2015
  • As TBM construction method is widely applied to construct underground transmission lines, increasing attention has been drawn to SFRC(steel fiber reinforced concrete) segment with respect to structural characteristics. Health hazards of electromagnetic wave which the underground transmission lines emit has emerged, and there is a concern that electromagnetic wave can be amplified because a segment characteristic such as electrical conductivity is changed by steel fibers. In order to analyze correlation between steel fiber dosage and electromagnetic wave, the specimens were fabricated on three conditions to perform experimental tests. From the measured data, it is proven that there is no correlation between the electromagnetic wave and steel fiber reinforced concrete.

The Study for the analysis of the detection efficiency and the design of the radiation detector's collimator using MCNP (MCNP 기반 스테레오 방사선 검출기 콜리메이터 설계 및 선량검출효율 분석연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Kang, Gi-Byong;Park, Jong-Won
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1017-1019
    • /
    • 2013
  • The radiation sources leaked from large-scale radiation leak accident like the Hukushima nuclear power plant accident or nuclear explosions can cause to the very large damage for us. So that the damage can be minimized, we have being developed a detector that can providing information about the location of the source to remove dangerous substances quickly than the conventional single detector. In this paper, we designed the shielding and collimator for the development of the Stereo Radiation detector in order to detect contaminants using MCNP Code. And we analyzed the results that is detected from the discretionary position of the radiation source. The results of this paper will be used as the basis for designing efficient structure for the radiation detectors.

  • PDF