• Title/Summary/Keyword: 차폐율(%)

Search Result 229, Processing Time 0.029 seconds

The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution (다목적 방사선 조사장치 개발 및 선량분포특성)

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.42-48
    • /
    • 2002
  • The design, construction and performance test of a convenient multi-purpose irradiator is described. A multi-purpose irradiator using Cesium-137 has been developed for studies of low dose radiation effects in biology and for calibration of Thermo Luminescent dosimeter(TLD). During the operation, three rods of radioactive material which are 10cm in length revolve 180 degrees and irradiate biological samples, or TLD, and return to their shielded position, after the programmed time. A programmable Logic Controller(PLC) controls the sequence of operation, interlock, motor rotation and safety system. The rotation speed of biological samples can vary up to 20 RPM. A real time monitoring system was also incorporated to check and control the operation status of the irradiator. The capacity of the irradiation chamber was 4.5 liters. The isodose distribution at arbitrary vertical planes was measured by using film dosimetry. The dose-rate was 0.13 cGy/min in air and 0.11 cGy/min in water equivalent material in the case of Cesium-137. Range of activity was 2 Ci. The homogeneity of dose distribution in the chamber was ${\pm}$7%. The actual radiation level on the surface was within permissible levels. The irradiator had a maximum 0.35 mR/min radiation leakage on its surface.

The Effect of Pore Structure of Zeolites on their Product Distribution and Deactivation in the Catalytic Cracking of n-Octane (n-옥탄의 촉매 분해반응에서 제올라이트의 세공구조가 생성물 분포와 활성저하에 미치는 영향)

  • Min, Byung Goo;Lee, Jae Youl;Song, Yo Soon;Seo, Gon
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.547-553
    • /
    • 2007
  • The catalytic cracking of n-octane over FER, MFI, MOR and BEA zeolites was studied by the protolytic cracking mechanism in order to understand the effect of pore structure of zeolites on their product composition and deactivation. The selectivities for $C_3$ and $C_3{^=}$ were high over the zeolites with medium pores due to additional cracking, while those for $C_4$ and $C_4{^=}$, the initial products, were high over the zeolites with large pores. MFI zeolite showed slow deactivation due to small carbon deposit, while FER zeolite with small pores deactivated rapidly with severe carbon deposit. The deactivation of BEA zeolite was slow even with a large amount of carbon deposit, but MOR zeolite showed a rapid deactivation even with a small amount of carbon deposit. The conversion measured along with the time on stream on these zeolite catalysts was simulated by a mechanism based on the simplified reaction path of n-octane cracking and the deactivation related to the pore blockage by carbon deposit.

Embodiment of High Impedance Surface of Meta-Material Characteristic Using Symmetrical AMC Structure and Its SAR Analysis (대칭형 인공자기도체 구조를 이용한 메타물질 특성의 고임피던스 표면 구현 및 SAR 특성 분석)

  • Lee, Seungwoo;Lee, Moung-Hee;Rhee, Seung-Yeop;Kim, Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.9
    • /
    • pp.744-750
    • /
    • 2013
  • In this paper, we proposed new type of an artificial magnetic conductor(AMC) structure, which has a high impedance surface for realizing the meta-material characteristics. The designed AMC structure set a goal of 3.2GHz, and the reflector, which consists of periodically arrayed AMCs is fabricated and measured. The high impedance improves the reflection coefficient, decreases the system size and interference, and increases the antenna performance. The structure has embodied the high impedance by the thickness and relative permitivity of the dielectric substrate and the design configuration without the metallic via hole which connects the AMC to the GND. The bandwidth is 150% broader than the similar AMC structures. Also, the distance between the antenna and the AMC reflector is decreased by ${\lambda}/10$ as working as the metal(PEC) reflectors. The antenna radiation characteristics are 3dB increased at 10mm away from reflector by measurement. The proposed reflector could be inserted in the portable mobile devices, and the antenna's performance has improved by the reflector. The specific absorption rate is dramatically decreased over 94% because the back radiation of the antenna is shielded.

Studies on the Processing and Utilization of Seaweeds 1. Preparation of Powdered Sea Mustard, Undaria pinnatifida, Mixtures for Juice Type Beverage (해조류(海藻類)의 가공(加工) 및 이용(利用)에 관한 연구(硏究) 1. 미역분말쥬스제조(製造))

  • Lee, Eung Ho;Cha, Yong Jun;Kim, Jeong Gyun;Kwon, ChiI Sung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.12 no.4
    • /
    • pp.382-386
    • /
    • 1983
  • In order to utilize effectively sea mustard(Undaria pinnatifida) which is excellent in nutrition and medical action, powdered sea mustard juice was prepared and then its chemical composition and the stability of pigments were examined. Powdered sea mustard was made by washing fresh sea mustard with tap water to remove clay and sand, blanching at $85^{\circ}C$ for 20 sec in mixing solution(3% salt+1% $MgCO_3$), hot air drying($50-55^{\circ}C$, 3 hrs) after draining and pulverizing dried sea mustard to 200mesh. And then powdered sea mustard mixtures for juice type beverage was made by adding 0.75% of salt, 1.25% of sugar, 0.2% of ascorbic acid, 0.25% of flour of roasted barley and 0.8% of pulverized sea mustard to 100ml of water. Chemical composition of product was not scarcely changed during processing while amino-nitrogen content was increased and alginic acid and ash contents were decreased. The retention of chlorophyll and total carotenoid pigments of product against fresh sea mustard were 91.6% and 89.5% respectively. Judging from sensory evaluation, color, flavor, taste and dispersibility of powdered sea mustard juice were excellent and undesirable flavor of product was masked by addition of flour of roasted barley.

  • PDF

Characteristics of the Electro-Optical Camera(EOC) (다목적실용위성탑재 전자광학카메라(EOC)의 성능 특성)

  • Seunghoon Lee;Hyung-Sik Shim;Hong-Yul Paik
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.3
    • /
    • pp.213-222
    • /
    • 1998
  • Electro-Optical Camera(EOC) is the main payload of the KOrea Multi-Purpose SATellite(KOMPSAT) with the mission of cartography to build up a digital map of Korean territory including a Digital Terrain Elevation Map(DTEM). This instalment which comprises EOC Sensor Assembly and EOC Electronics Assembly produces the panchromatic images of 6.6 m GSD with a swath wider than 17 km by push-broom scanning and spacecraft body pointing in a visible range of wavelength, 510~730 nm. The high resolution panchromatic image is to be collected for 2 minutes during 98 minutes of orbit cycle covering about 800 km along ground track, over the mission lifetime of 3 years with the functions of programmable gain/offset and on-board image data storage. The image of 8 bit digitization, which is collected by a full reflective type F8.3 triplet without obscuration, is to be transmitted to Ground Station at a rate less than 25 Mbps. EOC was elaborated to have the performance which meets or surpasses its requirements of design phase. The spectral response, the modulation transfer function, and the uniformity of all the 2592 pixel of CCD of EOC are illustrated as they were measured for the convenience of end-user. The spectral response was measured with respect to each gain setup of EOC and this is expected to give the capability of generating more accurate panchromatic image to the users of EOC data. The modulation transfer function of EOC was measured as greater than 16 % at Nyquist frequency over the entire field of view, which exceeds its requirement of larger than 10 %. The uniformity that shows the relative response of each pixel of CCD was measured at every pixel of the Focal Plane Array of EOC and is illustrated for the data processing.

Evaluation of the Jaw-Tracking Technique for Volume-Modulated Radiation Therapy in Brain Cancer and Head and Neck Cancer (뇌암 및 두경부암 체적변조방사선치료시 Jaw-Tracking 기법의 선량학적 유용성 평가)

  • Kim, Hee Sung;Moon, Jae Hee;Kim, Koon Joo;Seo, Jung Min;Lee, Joung Jin;Choi, Jae Hoon;Kim, Sung Ki;Jang, In-Gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.177-183
    • /
    • 2018
  • Purpose : Volumetric Modulated Arc Therapy(VMAT) has the advantage of uniformly and precisely irradiating the tumor to the shape of the tumor while reducing the risk of radiation damage to normal tissues. such as brain cancer, head and neck cancer and prostate cancer, It is being used for treatment. The purpose of this study is to evaluate the usefulness of the Jaw-Tracking technique(JTT) in VMAT for brain and head and neck cancer. Materials and Methods : We selected eight patients with brain and head and neck cancer(4 Brain, 4 head and neck) who were treated with the VMAT treatment technique. Contouring information of the patient's tumor and normal organ was fused to the Rando phantom using the deformable registration of Velocity(Varian, USA). A treatment plan was developed using the Varian Eclipse(ver 15.5, Varian, USA) with the same patient actual beam parameters except for the use of jaw-tracking. As the evaluation index, the maximum dose and mean dose of target and OAR were compared and a portal dosimetry was performed for the treatment plan verification. Results : When using JTT, the relative dose of OAR decreased by 5.24 % and the maximum dose by 7.05 %, respectively, compared with the Static-Jaw technique(SJT). In the various OARs, the mean dose and maximum dose reduction ranges ranged from 0.01 to 3.16 Gy and from 0.12 to 6.27 Gy, respectively. In the case of the target, the maximum dose of GTV, CTV, PTV decreased by 0.17 %, 0.43 %, and 0.37 % in JTT, and the mean dose decreased by 0.24 %, 0.47 % and 0.47 %, respectively. Gamma analysis The JTT and SJT passing rates were $98{\pm}1.73%$ and $97{\pm}1.83%$ on the basis of 3 % / 3 mm, respectively. Comparing the doses of all OARs applied to the experiment, it was found that the use of JTT resulted in a significant decrease in dose due to additional jaw shielding besides MLC than SJT. Conclusion : In radiation therapy using VMAT treatment plan, we can apply JTT in the case of adjacent tumor and normal organs such as brain cancer and head and neck cancer, and in radiotherapy required large field and high energy caused increase leakage dose through MLC. It is considered that the target dose of PTV can be increased by lowering the dose of normal tissue surrounding the tumor.

  • PDF

Fabrication of Backscatter Electron Cones for Radiation Therapy (산란전자선을 이용한 강내측방조사기구의 제작과 특성)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.74-80
    • /
    • 2001
  • Purpose : Irradiation cones by using backscatter electrons are made for the treatment of superficial small lesions of skin, oral cavity, and rectum where a significant dose gradient and maximum surface dose is desired. Methods and Materials : Backscatter electrons are produced from the primary electron beams from the linear accelerators. The design consists of a cylindrical cone that has a thick circular plate of high atomic number medium (Pb or Cu) attached to the distal end, and the plate can be adjusted the reflected angle. Primary electrons strike the metal plate perpendicularly and produce backscatter electrons that reflect through the lateral hole for treatment. Using film and a parallel plate ion chamber, backscatter electron dose characteristics are measured. Results : The depth dose characteristic of the backscatter electron is very similar to that of the hard x-ray beam that is commonly used for the intracavitary and superficial lesions. The basckscatter electron energy is nearly constant and effectively about 1.5 MeV from the clinical megavoltage beams. The backscatter electron dose rate of $35\~85\;cGy/min$ could be achieved from modern accelerators without any modification. and the depth in water of $50\%$ depth dose from backscatter electron located at 6mm for $45^{\circ}$ angled lead scatter. The beam flatness is dependent on the slit size and the depth of treatment, but is satisfactory to treat small lesions. Conclusions : The measured data for backscatter electron energy, depth dose flatness dose rate and absolute dose indicates that the backscatter electrons are suitable for clinical use.

  • PDF

Impact of Solar Energe Facility on the Landscape Experience of Traditional Temple - Focused on the Entrance Way of Tongdosa - (태양열시설이 전통사찰의 경관경험에 미치는 영향 - 통도사 진입경관을 중심으로 -)

  • Yi, Young-Kyoung;Kim, Jeong-Eun;Lee, Seo-Youl
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.3
    • /
    • pp.114-121
    • /
    • 2010
  • Traditional temples in Korea are the important cultural heritage because of artistic traditonal buildings and structures, paintings, sculptures, and big forest areas which are most ecological and beautiful in Korea. Since traditional temples still function as religious places for very long time, the sense of places intrinsic to the temples are very strong and vivid. The sense of place is very closely related to the conservation of the original landscape type. Recently however, there is a strong tendency to use solar energy in traditional temples because of the low energy efficiency of the old traditional architecture which may have negative impact on landscape which again in turn may lead to the destruction of the sense of place. The purpose of this study was to suggest some landscape design guidelines to protect the sense of place of traditional temple by investigating the impact of solar energy facility on the landscape experience of traditional temple. In order to do perform this purpose, Tongdosa was selected as a study site and four kinds of measurement tools(landscape image, temple identity, landscape satisfaction, degree of landscape improvement) were used as questionnaire items. 180 college students participated in the questionnaire survey. The analysis showed that the solar energy facility had very negative impact on landscape experience such as three landscape image factors(scenic beauty, openness, complexity), landscape satisfaction, temple identity, and landscape improvement. Based on the results, three landscape improvement plans were suggested. First, solar energy facility should be built in the forest in order not to be exposed to visitors, if possible. Second, the landscape management of traditional temple should emphasize on sustaining scenic beauty and temple identity along with the provision of openness. Lastly, detailed landscape guideline should be prepared to regulate the scale, ratio, and the form of the artificial buildings and structures to protect the sense of place of traditional temple.

Results of Hyperfractionated Radiation Therapy in Bulky Stage Ib, IIa, and IIb Uterine Cervical Cancer (종괴가 큰 병기 Ib, IIa, IIb 자궁경부암에서 다분할 방사선치료의 결과)

  • Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.349-356
    • /
    • 1997
  • Purpose : To evaluate the efficacy of hyperfractionated radiation therapy in carcinoma of the cervix, especially on huge exophytic and endophytic stage Ib, IIa and IIb Materials and Materials : Fourty one patients with carcinoma of the cervix treated with hyperfractionated radiation therapy at the Department of Therapeutic Radiology, Dongsan Hospital, Keimyung University. School of Medicine from Jul, 1991 to Apr, 1994. According to FIGO s1aging system, therewere stage Ib (3 patients) IIa (6 patients) with exophytic ($\geq$5cm in dinmeter) and huge endophytic mass. and IIb (32 patients) with median age of 55 yeavs old. Radiation therapy consisted of hyperfractionated external irradition to the whole pelvis (120cGy/fraction, 2 fraction/day (minimum interval of 6 hours), 3600-5520cGy) and boost parametrial doses (for a total of 4480-6480cGy) with midline shield $(4\times10cm)$, and combined with intracavitary irradiation (up to 7480-8520cGy in Ib, IIa and 8480-9980cGy in IIb to point A). The maximum and mean follow up durations were 70 and 47 months respectively . Results : Five year local control rate was $78\%$ and the actuarial overall five year survival rate was $66.1\%$ for all patients, $44.4\%$ for stage Ib, IIa and $71.4\%$ for stage IIb. In bulky IIb (above 5cm in tumor size, 11 patients) five year local control rate and five rear survival rate was $88.9\%,\;73\%$ respectively Pelvic lymph node status (negative : $74\%,\;positive:25\%$, p=0.0015) was significant Prognostic factor affecting to five rear survival rate. There was marginally significant survival difference by total dose to A point ($>84Gy\;:\;70\%,\;>84Gy\;:\;42.8\%$, p=0.1). We consider that the difference of total dose to A point by stage (mean Ib,IIa : 79Gy. IIb 89Gy P=0.001) is one of the causes in worse local control and survival of Ib,IIa than IIb The overall recurrence rate was $39\%$ (16/41). The rates of local failure alone. distant failure alone. and combined local and distant failure were $9.7\%,\;19.5\%,\;and\;9.7\%$, respectively. Two Patients developed leukopenia ($\geq$ grade 3) and Three patients develoued grade 3 gastrointestinal complication. Above grade 3 complication was not noted. There was no treatment related death noted. Conclusion : We thought that it may be necessary to increase A point dose to more than 85Gy in hyperfractionated radiotherapy of huge exophytic and endophvtic stage Ib,IIa. We considered that hyperfractionated radiation therapy may be tolerable in huge exophytic and endophytic stage IIb cervical carcinoma with acceptable morbidity and possible survival gain but this was results in small patient group and will be confirmed by long term follow up in many patients.

  • PDF