Slab Thickness Calculations on Hot Cell

  • Ha, Yung-Joon;Kim, Seong-Yun;Kim, Dong-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.26-36
    • /
    • 1978
  • Numerical computations of radioactivities and decay energies in a spent fuel have been carried out for designing of a hot cell. Optimum wall and window thicknesses that can preserve spent fuel rods for experimental purposes are estimated with burnup rate of 33,000 MWD/T(U) which is nearly maximum from a pressurized water reactor such as the Go-Ri Unit 1. Before putting the spent fuels into a hot cell, it is assumed for thickness estimates of shield materials that they are cooled in a storage tay for several lime intervals. Considered are various types of shield materials through which changing the distances from a source to an observation point is also made.

  • PDF

Reducing Radiation Exposure Dose on Operator by Using Lateral Protection in Neuro-Intervention (뇌혈관 중재적시술에 있어 측방향 차폐체를 이용한 시술자 피폭 선량 저감화 방법 연구)

  • Kim, Jongdeok;Ahn, ByeoungJu;Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • The bi-plane cerebrovascular angiography radiation is done the radiation exposure at the forward and lateral direction as opposed to the one of the source. So, the exposure dose of radiation workers increases further. Therefore, the medical diagnostic radiation workers as well as patients is interested to ways to reduce the dose. The exposure dose of cerebral angiography and interventional radiology must be considered the primary radiation of X-ray tube directly, scattered primary radiation between lateral tube and lateral detector and relatively small secondary scatter radiation in the walls of room. The aim of study is that the exposure dose of primary and scatter radiation reduce as much as possible to install protection device of lateral protection than common shielding of table and ceiling. As a result, the dose of fluoroscopy was reduced approximately 3.64 times the gonads, thyroid approximately 3.13 times, 4.42 times around eyes. And the dose of DSA was reduced approximately 4.98 times the gonads, thyroid approximately 3.00 times, 1.67 times around eyes. Consequently, medical practitioners can be helpful for radiation dose-exposure for the lateral protection of bi-plane cerebrovascular angiography more than the common shield method in cerebrovascular angiography and interventional radiological procedures.

Wave Reflection and Transmission Characteristics of Flap-type Floating Breakwaters (플랩형 부유 방파제의 파랑 반사 및 전달 특성)

  • Jeong, Shin-Taek;Park, Woo-Sun;Kim, Jeong-Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.2141-2145
    • /
    • 2008
  • Three kind of system composed with buoyant flap hinged at the sea floor are modeled experimentally. The mechanically coupled system provides shelter by reflecting incident waves and by attenuating wave energy through structural and viscous damping. The characteristics of wave reflection, transmission and dynamic angle of the flap oscillation for various conditions were investigated. The structure can minimize wave transmission by attaching offshore wing wall.

  • PDF

A Study on Application Boundary of Wireless LAN's Communication for Space Variation (공간변화에 따른 Wireless LAN의 통신 활용 범위에 관한 연구)

  • Cha, Jin-Man;Kang, Min-Soo;Park, Yeoun-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.499-503
    • /
    • 2005
  • The objective of this thesis is to measure the limit of the real space where wireless Local Area Network(LAN) is used, and to apply this result as reference to set up a real Wireless LAN environment. The organized circumference was composed of Wireless LAN based on IEEE 802.11b of the American standard, and the examination is carried out on the campus. On the real condition of office environment and open space, the ratio of available distance to a signal at each distance was measured and this result was studied as data to embody wireless LAN on the campus. The measurement under an indoor environment was executed under circumstance having two wall and open space, however, was executed respectively under three circumstances : Where no obstacle, where one wall exists, and where two or more walls exist.

  • PDF

Calculation of the Air-Scattering Dose Rate by the Single Scattering Approximation (단일산란근사법(單一散亂近似法)에 의한 공기중(空氣中) 산란방사선량(散亂放射線量)의 계산(計算))

  • Yook, Chong-Chul;Ha, Chung-Woo;Lee, Jai-Ki;Moon, Philip S.
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.21-28
    • /
    • 1979
  • A calculation is presented of air-scattered gamma rays using the modified single-scattering approximation. The air-scattered tissue dose rates are calculated for a general purpose taking into account (a) the buildup and exponential attenuation, (b) the energy spectrum at the position of question and (c) the geometrical scattering volume in three dimensions. These calculations have been further modified to render them applicable to a typical field irradiation facility which is surrounded by a shield wall and in which the source is fitted with a beam collimating device. The results of the calculation include the energy spectra, angular distribution and tissue does rates at source-receiver separation distances of from 35m to 300m. The comparison shows that the present method developed may be generally adequate for the gamma-ray air-scattering problems in field irradiation facilities if energy and angular distribution at the shield are unimportant.

  • PDF

Experimental Study of Frozen Barrier Using Artificial Ground Freezing System (인공지반동결 시스템을 이용한 동결차수벽의 실험적 연구)

  • Shin, Eun-Chul;Kang, Hee-Myeong;Park, Jeong-Jun;Kim, Sung-Hwan
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.3
    • /
    • pp.35-44
    • /
    • 2009
  • The purpose of this study was to prevent spreading of contaminants from movement of underground water by creating a barrier using artificial freezing method on a soil contaminated by oils and various NAPLs. Specimens with 80% and 90% degrees of saturation were prepared to form freezing barrier using artificial freezing method. With increasing freezing time of freezing barrier, barrier was formed faster in the specimen with 90% degree of saturation by about an hour compared to the specimen with 80% degree of saturation. In addition, thinnest thickness of frozen barrier in both specimens was 50mm after 12 hours of freezing time, showing expansion of freezing area with time. The results of this study can be applied to barrier in waste reclamation sites and contaminated regions or to flow control of contaminants.

  • PDF

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

Evaluation of sustainability of mobile phone case and improvement of electromagnetic shielding by nano particles (휴대폰 케이스의 지속가능성 평가 및 나노 입자를 사용한 전자기파 흡수성능 개선)

  • Kang Y.C.;Jung W.K.;Ahn S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.477-480
    • /
    • 2005
  • In this paper, the concept of sustainability was applied to mechanical design and manufacturing of mobile-phone case. A new evaluation method to find products' good and weak point for sustainability was developed. Two mobile phones were evaluated using the evaluation tool. As a result, electro-magnetic (EM) wave was considered as a harmful factor of the products, and improved front panel was made using nano particles that absorb EM waves. The EM shielding tests revealed that silver nano powders absorbed EM while MWCNT had no effect.

  • PDF

Shielding Capability Evaluation of Mobile X-ray Generator through the Production assembled Shield (일체형 방어벽 제작을 통한 이동형 엑스선 발생기의 차폐능 평가)

  • Kim, Seung-Uk;Han, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.895-908
    • /
    • 2018
  • As modern science is developed and advanced, examination and number of times using radiation are increasing daily. General diagnostic X-ray generator is installed on stationary form, But X-ray generator was developed because patient who is in the intensive care unit, operation room, emergency room can not move to general x-ray room. What we examine patient by x-ray generator is certainly necessary, So patient exposure is inevitable. but reducing radiation exposure is highly important matter about radiation technology, guardian, patient in the same hospital room, nurse etc. For this reason, rule regarding safety control of diagnostic x-ray generator revised for radiation worker, patient and protector proclaim that mobile diagnostic x-ray shield must placed in case of examine different location excluding operation room, emergency room, intensive care unit. But, radiogical technologist is having a lot of difficulties to examine with mobile x-ray generator, diagnostic x-ray shield partition, image plate and lead apron. So, when we use x-ray generator, we manufacture shield tools can be attached to the mobile x-ray generator On behalf of x-ray shield partition and conduct analysis and in comparison to part of body and distribution of dose rate and find way to reduce radiation exposure through distribution of dose rate of patient within the radiogical technologist, medical team. Mobile x-ray generator aimed at SHIMADZU inc. R-20, We manufactured equipment for shielding x-ray scattered x-ray by installing shielding wall from side to side based on support beam on the mobile x-ray generator. Shielding wall when moving can be folded and designed to expand when examine. Experiment measured five times in each by an angle for dose rate of eyes, thyroid, breast, abdomen and gonad on exposure condition of upper and lower extremity, chest, abdomen which is examined many times by mobile x-ray generator. We used dosimeter RSM-100 made by IJRAD and measured a horizontal dose rate by body part. The result of an experiment, shielding decreasing rate of the front and the rear showed 77 ~ 98.7%. Therefore using self-production shielding wall reduce scattered x-ray occurrence rate and confirm can decrease exposure dose consequently. Therefore, through this study, reduction result which is used shielding wall of self-production will be a role of shielding optimization and it could be answer about reduction of medical exposure recommended by ICRP 103.

The Characteristic and Control of Contaminant Transport through the Subsurface of Nanjido Landfill (난지도 매립장 지반을 통한 오염이동 특성과 제어)

  • 장연수;이광열
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 1994
  • The contaminant migration through the subsurface of Nanjido landfill is studied using a 2-D finite element model of contaminant transport. The leachate mounding caused by the installation of partial slurry wall around the pheriperal area of the Landfill is analysed using the finite difference model of groundwater flow. Model parameters were validated using in-situ concentration data and the behavior of the transport next 30 years is predicted. The sensitivities of chloride concentration by the change of model parameters, e.g. leachate mounding in the Landfill and the dispersivity are analysed. The results of the analyses show that the maximum chloride concentration level near Han River caused by the leachate of Nanjido Landfill would be 1488mg/1 and comes 17 years after the landfill closure. Increase of the leachate concentration is caused by the increase of both the leachate mounding and the dispersivity. However, the rate of concentration increase becomes higher with the rise of leachate mounding level, while it tends to converge a certain concentration with the increase of the dispersivity.

  • PDF