• Title/Summary/Keyword: 차음측정

Search Result 90, Processing Time 0.036 seconds

Field Measurement of the Reverberation Time in Occupied and Unoccupied Apartment Houses (공동주택 입주 전.후 세대에서의 잔향시간 측정 및 비교)

  • Lee, Byoung-Ki;Kim, Myung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.654-657
    • /
    • 2005
  • The aim of this study is to investigate and to analyze the reverberation times of apartment houses Measurements were conducted in a total of 44 rooms(36 rooms were in occupied houses and 8 rooms were in unoccupied houses) according to KS F 2864. The results showed that the averaged reverberation time of the occupied and the unoccupied houses were about 0.3$\sim$0.5sec and 1.2$\sim$l.5 sec, respectively, at 500Hz octave band frequency. And the averaged absorbtion coefficient of the occupied and the unoccupied houses were about 0.13$\sim$0.35 and 0.11$\sim$0.20, respectively. In addition, We verified that the reverberation time generally depended on the frequency; the lower the frequency, the higher the reverberation time.

  • PDF

A Study on the Sound Transmission Loss Measurement of Sound Isolation Sheets (차음시트의 음향투과손실 측정에 관한 연구)

  • Lee, Dong-Hoon;Kang, Moon;Lee, Ju-Weon;Jung, Gab-Cheol;Kwon, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.409-414
    • /
    • 2000
  • A new impedance tube method is presented for the measurement of transmission loss of sound isolation sheets. The two-microphone method based on the sound decomposition theory proposed by Seybert and Ross is reviewed in this impedance tube method, which has been used for the determination of absorption coefficient of absorptive materials as well as transmission loss of automotive mufflers. Sound transmission losses for rubber, polyvinyl and asphalt sheets are measured in an impedance tube and reverberation room facility, respectively. By comparing two measurement methods, the reliability of impedance tube method used in this study is validated. From the experimental results, it is shown that the accuracy of sound isolation capability obtained by the impedance tube method depends upon the microphone spacing and the distance of the first microphone from the test sample surface.

  • PDF

A Study on Digital Communication in Air Using Parametric Array (파라메트릭 어레이를 이용한 공기 중 디지털 통신 연구)

  • Je, Yub;Lee, Jae-Il;Lee, Chong-Hyun;Moon, Won-Kyu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.768-773
    • /
    • 2009
  • This paper demonstrates the digital communication in air using the parametric array. The stepped-plate transducer which is suitable for high-power and high-efficient radiation is used to generate the difference frequency wave with the parametric array. The primary frequencies are selected to 83 kHz and 122 kHz and the resulting difference frequency wave at the frequency of 39 kHz is used for the communication. The modulation method is selected to On-Off Keying method. The waveform and signal-to-noise ratio (SNR) is measured and analyzed to see the characteristics of the digital communication using the parametric array. The proper distance for the communication using parametric array is about 3 m. The measured beam width of the 3dB SNR reduction was $14^{\circ}$. The possibility of the communication in air using the parametric array is confirmed and the high directional characteristic of the communication using the parametric array is expected to have the advantages for the multi path and the security problems.

Deviation of Heavy-Weight Floor Impact Sound Levels According to Measurement Positions (마이크로폰의 위치에 따른 중량 바닥충격음레벨의 편차)

  • Oh Yang-Ki;Joo Moon-Ki;Park Jong-Young;Kim Ha-Geun;Yang Kwan-Seop
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.49-55
    • /
    • 2006
  • Measurement of impact sound insulation of floor, by current Korean Standard KS F 2810-2. is to be made with peak levels over 4 point in a receiving room. But it is often the case that there is inconsistency in results at various receiving points in the receiving room. Such variations obviously have effects on the repeatability and reproducibility of measured data. The result shows that there are even 10 dB deviations in 63Hz octave band frequency range and relatively less variations are occurred in other low frequency ranges. Such variations seems to be coming from modal overlaps of the receiving room. According to current rating method of floor impact sound. KS F 2863-2, that may affect on the single number latins scheme. From the result of tests in this study, there are 2dB to 6dB differences in the sin91e number with the combination of measurement points. This means that the reduction of measurement variations from the microphone positions is needed for a better credibility of measurement results.

Study on Preliminary Influence Analysis of Construction Noise and Vibration (건설 소음.진동의 사전 영향성 분석에 관한 연구)

  • Ahn, Myung-Seok;Kim, Hwa-Il;Park, Ju-Han
    • Explosives and Blasting
    • /
    • v.32 no.2
    • /
    • pp.25-30
    • /
    • 2014
  • Although the construction noise and vibration are transient and intermittent, their impact on the surrounding environment is huge. Since the construction equipment noise and vibration is usually transmitted because of the long distance, the sound insulation and the proper design of anti-vibration measures are very difficult. The regulation requires that the noise and vibration caused by the construction equipments should be measured within 30m from the source, whereas the blasting noise and vibration should be measured at least 60m and 160m away from the source, respectively. Instead of the 2D modelling mainly conducted so far, the 3D analysis of noise and vibration with the consideration of the height and size of the building, mountains and hills in the vicinity of the source is necessary.

Measurement of Gastric Contractility of Awake Rats by Bowel Sounds Recorded through an Electronic Stethoscope in a Sound Insulation Box (차음상자와 전자청진기로 기록된 장음에 의해서 깨어 있는 흰쥐의 위수축력 측정)

  • Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.4
    • /
    • pp.439-447
    • /
    • 2014
  • Objectives: The aim of this study was to investigate whether 1) variation of bowel sounds recorded stably through an electronic stethoscope in a sound insulation box can be related with that of gastric contraction and 2) if they are thus useful tool in the measurement of the gastric contractility in awake rats or not. Methods: Electrical potentials of both electronic stethoscope of bowel sound and force transducer were recorded simultaneously and continuously in the sound insulation box for the starting 30 min of basal state, and then 30 min of 0.2 ml normal saline administration, finally 30 min of 0.2 ml mosapride citrate solution (100 mg/Kg) in rats. Each motility index of normal saline or mosapride citrate treatment was presented with ratio against the basal state by using integrated electrical potentials. Results: A pattern of significance of gastric contractility between bowel sound and force transducer was showed analogously. Conclusions: The amplitude of bowel sounds recorded by the electronic stethoscope related with the intensity of gastric contractions. This confirms that a sound insulation box and electronic stethoscope are useful tools in the measurement of the gastric contractility of awake rats.

The Limit and Application of Two-microphone Impedance Tube Method to the Sound Transmission Loss Measurement of Sound Isolation Materials (차음재의 음향투과손실 측정에 Two-Microphone Impedance Tube Method의 적용과 한계)

  • Lee, Seung;Ahn, Min-Hong;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.883-888
    • /
    • 2002
  • This study describes the limit and application of the two-microphone impedance tube method to the sound transmission loss measurement of several sound isolation materials with different physical properties. For the sound isolation materials having small flexural rigidity, it is shown that the two-microphone impedance tube method is validated to practically measure the sound transmission loss. For the sound isolation materials having large flexural rigidity, on the other hand, it is found that the two-microphone impedance tube method is no longer valid to measure the sound transmission loss because the regions of resonance and mass law are moved into the higher frequencies. In addition, in order to accurately measure the sound transmission loss of sound isolation materials, their size should be decided based on the consideration of the effect of acoustic excitation on their vibration response.

  • PDF

Characteristics of the Functional Panel Made from Foamed Aluminum (발포알루미늄을 이용하여 제조한 기능성 판넬 특성 연구)

  • Kim, Jae-Yong;Um, Myeong-Heon;An, Dae-Hyun;Shim, Myeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2006
  • In this work, the properties of environmentally friendly functional panel made from waste aluminum were investigated. Product quality enhancement was pursued through an improved viscosity process, a mixing process by agitating, a foaming process, a cooling process, and a color addition process. An acoustic transmission attenuation test, a sound adsorption rate measurement test, and a foaming condition and scrap mixing test were implemented. As a result, the functional panel made from waste aluminum was ultra lightweight and had excellent properties such as soundproof, sound interception, and shielding harmful electromagnetic waves. Also, the functional panel showed low thermal conductivity (about 2.2 kcal/mh) and excellent heat-insulating property.

Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance (바닥충격음 측정 및 차음 평가의 방향)

  • Jeong, Jeong-Ho;Jeong, Yeong;Seo, Sang-Ho;Song, Hee-Soo;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

Development of Noise-proof Facility Considered with Soundproofing Materials in a Tunnel Blasting (터널 발파에서 방음재질을 고려한 방음문 개발에 관한 연구)

  • Jeoung, Jae-Hyeung;Won, Yeon-Ho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.3
    • /
    • pp.27-35
    • /
    • 2011
  • This study investigated a sound reduction degree by each soundproofing materials and the sound pressure level of a main frequency range to develop soundproofing facilities installed for reducing sound in a tunnel blasting. The frequency range and sound pressure level of soundproofing materials(eg. sand and water etc.) mainly used at a working spot were measured using the experimental apparatus considered with blasting situation. The full scale pilot test was also carried out using developed soundproofing facilities in this study. And the performance of developed soundproofing facilities was analyzed. As a result, the developed soundproofing facilities using water in sound insulation materials could reduce about 10dB(A) of blasting noise in compare with the existing soundproofing facilities.