• Title/Summary/Keyword: 집전성능

Search Result 67, Processing Time 0.024 seconds

Ultra Slim U-I & W-I Primary and Pick-up Coil Design for OLEV (온라인 전기자동차용 초박형의 U-I형 및 W-I형 급집전코일 설계)

  • Lee, Sung-Woo;Park, Chang-Byung;Cho, Jung-Goo;Cho, Gyu-Hyeong;Rim, Chun-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.274-282
    • /
    • 2011
  • The ultra slim U-I and W-I primary and pick-up coils for OLEV (On-Line Electric Vehicles) are proposed. With the proposed structures, the amount and the cost of the core are dramatically reduced. Not only air gap but also the lateral displacement are improved. The proposed structures are applied to the OLEV bus and SUV, which achieve 83% efficiency at 17cm air gap with more than 60kW output power, and the construction cost is lower than ₩300M/km. The proposed coil structures are verified with simulations and experiments.

Evaluation of Electrochemical Stability and Performance of Graphite Sheets as Current Collectors for Lead Acid Battery (납축전지 전류집전체로서 그라파이트 시트의 전기화학적 안정성과 방전성능 평가)

  • An, Sang-Yong;Kim, Eung-Jin;Yoon, Youn-Saup;Kim, Hee-Jung
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.2
    • /
    • pp.128-131
    • /
    • 2010
  • Graphite sheet electro-deposited with lead was evaluated as a possible candidate for current collectors of lead acid batteries. Cyclic voltammetry was performed on the materials to evaluate the electrochemical properties. The graphite sheet electro-deposited with lead is electrochemically stable in the cathodic potential sweep. However, in the anodic potential sweep, the graphite sheet electro-deposited with lead is electrochemically unstable due to the oxygen evolution and the intercalation of sulfuric acid. Lead acid batteries were prepared by using a graphite sheet and a cast grid as current collectors for anode and performance test using those batteries was carried out. A lead acid battery with graphite sheets showed higher capacity and energy density than a conventional lead acid battery with cast grid.

Thermal Characteristics Analysis of Upper Arm Hybrid Structure of Lightweight Pantograph Considering Heat Source by Collecting Current (집전전류에 의한 열원을 고려한 경량 판토그래프 상부암 혼성구조체의 열 특성 분석 연구)

  • Park, Chan-Bae;Jeong, Geochul
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.4
    • /
    • pp.466-473
    • /
    • 2017
  • Recently, domestic railway related institutes are developing pantographs for high speed trains; to lighten the upper arm, this device has a composite structure of CFRP (Carbon Fiber Reinforced Plastic) and aluminum instead of conventional steel. In the case of KTX-Sancheon, the pantograph must have a large current capacity because this system is of power-car type, supplying all necessary power for the train through a single pantograph. If the thickness of the pipe is arbitrarily increased in order to increase the current carrying capacity, without analyzing the thermal characteristics of the aluminum pipe, the increase in the weight of the upper arm may cause degradation of the current collecting performance. Therefore, in this paper, using the thermal analysis technique, we analyze the temperature change characteristics of the aluminum pipe of the upper arm over time, while receiving power at the stationary state of the KTX-Sancheon; we also examine the adequacy of the minimum thickness of the aluminum pipe in accordance with the proposed pantograph flow capacity.

Performance Evaluation and Sensitivity Analysis of the Pantograph for the High-Speed Train Using Finite Element Analysis Method (유한요소해석 기법을 이용한 고속철도용 판토그래프 집전성능 평가 및 민감도 분석)

  • Lee, Jin-Hee;Paik, Jin-Sung;Kim, Young-Guk;Park, Tae-Won
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1874-1880
    • /
    • 2011
  • In this paper, sensitivity analysis of the pantograph for the high-speed Train was conducted using finite element analysis method. Dynamic interaction of catenary-pantograph model was simulated by using a commercial finite element analysis software, SAMCEF. Pantograph was assumed to be three degree of freedom mass-spring-damper model and the pre-sag of the contact and messenger wire was implemented due to gravity. The span data of the actual high-speed line and specification of pantograph for high-speed train was applied in the analysis model, respectively. The reliability of the simulation model is verified by comparing the contact force results of simulation and test. Through the simulation, mean contact force and its deviation was evaluated and then sensitivity of the pantograph was analyzed.

  • PDF

Performance Test of $3^{rd}$ rail type power collector for rubber-tired AGT light rail vehicle (고무차륜 AGT 경량전철 차량용 제 3 궤조 집전장치의 성능시험)

  • Park S.H.;Kim Y.S.;Kim K.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1341-1344
    • /
    • 2005
  • This study was aimed to verify the acceptable contact force between power collector and 3rd rail type conductor rail for the Korean standardized rubber-tired AGT light rail vehicle. The power collector was designed and manufactured to satisfy the Korean standardized Specifications of the rubber-tired AGT light rail vehicle. Based on the dynamic behavior, contact force variation and interruption in the worst installation tolerance of the conductor rail, its initial contact force was set up. At the test track for the Korean standardized rubber-tired AGT light rail vehicle, interruptions, stresses, vibrations, and contact force variations were measured. As the results, initial contact force was verified to ensure power collection stability.

  • PDF

Design of the Linear Propulsion System of a High-Speed Dynamic Tester for Catenary-Current Collection (전차선로-집전계 주행시험기용 리니어 추진시스템 설계)

  • Kwon, Sam-Young;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.63-70
    • /
    • 2006
  • This paper presents design of the linear propulsion system of a high-speed (200km/h) dynamic tester for catenary-current collection. Among various propulsion systems, a permanent magnet linear synchronous motor is chosen for need of high acceleration force. The design is performed by the equivalent magnetic circuit method and verified by the finite element method. In addition, analysis of the main effects of various design variables for performance of the propulsion system has been done by using simulation-based DOE method.

Current Collection Performance of Catenary System within Tunnel Section (터널구간 가선계의 집전성능)

  • Son Gun-Ho;Lee Seung-Il;Choi Yeon-Sun
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.767-772
    • /
    • 2004
  • A dynamic simulation program of a catenary-pantograph system including tunnel section and transient section is developed in this study. The simulation program can accommodate for the pantograph of two panheads and three d.o.f model. Using the developed program, the dynamic characteristics with a SCHUNK'S WBL 85-PANTOGRAPH is analyzed at the conventional TAEBAEK line and its tunnel section when the catenary system is supported by a tunnel bracket. The simulation results show that the variation of contact force and uplift displacement is allowable in general section and the entrance and exit of a tunnel, but the uplift displacement and the separation ratio within tunnel section is difficult to allow.

  • PDF

Current Collection of Catenary System with Time-Varying Stiffness (시변강성 가선계의 집전성능)

  • 최연선
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.3
    • /
    • pp.131-138
    • /
    • 2000
  • The design of current collection system of high speed train requires the fundamental understandings for the dynamic characteristics of catenary system and pantograph. The stiffness of catenary system of high speed train has the varying characteristics for the change of contact point with pantograph, since the supporting pole and hanger make the different boundary conditions for the up-down stiffness of a trolley wire. The variation of stiffness results in Mathiue equation, which characterizes the stability of the system. However, the two-term variation of the stiffness due to span length and hanger distance cannot be solved analytically. In this paper, the stiffness variations are calculated and the physical reasoning of linear model and one term Mathieu equation are reviewed. And the numerical analysis for the two-term variation of the stiffness is done for the several design parameters of pantograph.

  • PDF