• Title/Summary/Keyword: 질산성 질소

Search Result 583, Processing Time 0.03 seconds

A Basic Study on the Simultaneous Removal of Ammonium and Nitrate using Zeocarbon (제오카본을 이용한 암모니아성 질소와 질산성 질소 동시 제거에 관한 기초 연구)

  • Kim, Seo-A;Hong, Ji-Sook;Suh, Jeong-Kwon;Kang, Ho;Lee, Jung-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.109-114
    • /
    • 2005
  • The objective of this study is to investigate the possibility for water treatment, and to evaluate the efficiency of simultaneous removal of ammonium and nitrate by the surface modified zeocarbon. The surface modification was done by acid treatment using HCl. As a result of modification, strength of the modified zeocarbon was enhanced about 62% higher than that of in original one. This indicates that the modified zeocarbon was suitable for the application of water treatment. In the removal experiments of ammonium and nitrate, the removal efficiency showed about two times higher in the modified zeocarbon and the dependences of pH and temperature were found to be minimized. This indicates that the modified zeocarbon was effective for simultaneous removal of ammonium and nitrate from aqueous solution. Consequently, our results could be used as basic data to design of one-stage ammonium/nitrate simultaneous removal system.

Characteristics of Nitrate Removal Using Micellar-enhanced Ultrafiltration (MEUF에 의한 질산성 질소 제거에 관한 연구)

  • 백기태;이현호;김보경;김호정;양지원
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.2
    • /
    • pp.36-43
    • /
    • 2003
  • Feasibility of micellar-enhanced ultrafiltration far the removal of nitrate was investigated using cationic surfactants, cetylpyridinium chloride and octadecylamine acetate. The removal of nitrate increased as the molar ratio of surfactant increased. With the molar ratio of 3, at least 80% of nitrate was removed, while > 98% of nitrate was removed at the surfactant molar ratio of 10. Octadecylamine acetate showed higher removal efficiency of nitrate and higher rejection of surfactant than cetylpyridinium chloride because of the accessibility of nitrate to surfactant micelles due to head group of surfactant. Octadecylamine acetate turned out to be a better surfactant than cetylpyridinium chloride for micellar-enhanced ultrafiltration to remove nitrate from groundwater.

Seasonal Variation of Surface Water Quality in a Catchment Contaminated by $NO_3-N$ (질산성 질소로 오염된 소유역 하천 수질의 계절 변화)

  • Kim Youn-Tae;Woo Nam-Chil;Lee Kwang-Sik;Song Yun-Goo
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.2
    • /
    • pp.20-27
    • /
    • 2005
  • The seasonal variation of water quality was studied in the Hwabongcheon. It runs though a small catchment where shallow groundwater was contaminated with $NO_3-N$ by intensive livestock facilities. A direct inflow of animal waste and incoming of contaminated groundwater affected its water quality. In the dry season, an important factor of water quality in the Hwabongcheon was direct inflow of animal waste. In the wet season, concentrations of $NO_3-N$ in the Hwabongcheon were elevated in spite of being diluted by precipitation. It could be explained by the effect of increased incoming of contaminated groundwater and showed by oxygen and hydrogen isotope values. $NO_3-N$ concentration in the Cheongmicheon was lower than that in the Hwabongcheon, so it increased next a junction. This effect was intense in wet season because $NO_3-N$ concentration in the Hwabongcheon was high.

A pilot study on attenuation of nitrate in a paddy rice field: preliminary results

  • 최병영;윤성택;김강주;김동승;전종욱;윤성문
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.93-96
    • /
    • 2004
  • 국내 대부분의 경작지를 차지하고 있는 논농사 지역에서의 질산성 질소의 자연저감을 고찰하기 위하여, 세 유형의 수조 환경을 조성하고 mesocosm 실험 연구를 수행하였다. 두개의 mesocosm에는 논토양을, 그리고 비교를 위하여 다른 하나에는 밭토양(황토)을 사용하였으며, 하나의 논토양 mesocosm과 밭토양(황토) mesocosm에는 벼를 재배하였다. 인위적으로 질산성 질소 성분을 용해한 지하수를 주입수로 사용하였으며, mesocosm을 통과한 물 시료를 41일 동안 12시간 또는 24시간 간격으로 채취하고 화학분석을 실시하였다. 실험 결과, 논토양에서는 실험 시작과 동시에 급격한 환원환경이 형성되었으며, 그 결과 탈질반응에 의해 질산성 질소의 농도가 현저히 저감되었다. 분석 자료의 해석 결과, 논토양 mesocosm에서는 유기물이, 밭토양 mesocosm에서는 철이온(Fe2+)이 질산성 질소의 탈질 반응에 중요한 역할을 수행하는 것으로 판단된다.

  • PDF

Transformation of Nitrogen in the Form of Nitrate into Ammonia by Electrochemical Reaction (전기화학적 반응을 이용한 질산성 질소의 암모니아성 질소로 전환)

  • Lee, Jae Kwang;Kim, Doyeon;Tak, Yongsug
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.1013-1016
    • /
    • 2008
  • Nitrogen in the form of nitrate was electrochemically reduced with different cathode materials including Fe, Ni, Cu, and Zn. Zn cathode shows the greatest electrocatalytic activity on the transformation of nitrate ions into ammonia and the $NO_3^-$ removal efficiency has highest value at pH 8.5. Nitrogen in the form of nitrate was initially reduced into nitrite and sequentially, converted into nitrogen inside $NH_3$. Nitrogen in the form of ammonia was completely removed by the reaction with HOCl.

A Study on the Optimum Operating Conditions and Effects of Wastewater Characteristics in Electrochemical Nitrogen Removal Process (질소 제거를 위한 전기화학적 처리 공정의 최적 운전조건 및 폐수 성상에 따른 영향에 관한 연구)

  • Sim, Joo-Hyun;Kang, Se-Han;Seo, Hyung-Joon;Song, Su-Sung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.29-34
    • /
    • 2009
  • This study was performed under four operational conditions for nitrogen removal in metal finishing wastewater. The conditions include electrode gap, reducing agent, the recycling of treated wastewater in 1st step and the simultaneous treatment of nitrate and other materials. Result showed that the removal efficiency of $NO_3{^-}-N$ was highest at the electrode gap of 10 mm. As the electrode gap was shorter than 10 mm, the removal efficiency of $NO_3{^-}-N$ decreased due to increasing in concentration polarization on electrode. And, in case that the electrode gap was longer than 10 mm, the removal efficiency of $NO_3{^-}-N$ increased with an increase in energy consumption. Because hydrogen ions are consumed when nitrate is reduced, reducing reaction of nitrate was effected more in acid solution. As 1.2 excess amount of zinc was injected, the removal efficiency of $NO_3{^-}-N$ increased due to increasing in amount of reaction with nitrate. As the effluent from 1st step in the reactor was recycled into the 1st step, the removal efficiency of $NO_3{^-}-N$ increased. Because the zinc were detached from the cathode and concentration-polarization was decreased due to formation of turbulence in the reactor. The presence of $NH_4{^+}-N$ did not affect the removal efficiency of $NO_3{^-}-N$ but the addition of heavy metal decreased the removal efficiency of $NO_3{^-}-N$. As chlorine is enough in wastewater, the simultaneous treatment of nitrate and ammonia nitrogen may be possible. The problem that heavy metal decrease the removal efficiency of $NO_3{^-}-N$ may be solved by increasing current density or using front step of electrochemical process for heavy metal removal.

Isolation and Characterization of Denitrification Bacteria (탈질 세균의 분리 및 특성)

  • 차월석;최형일;이동병;차진명
    • KSBB Journal
    • /
    • v.18 no.6
    • /
    • pp.461-465
    • /
    • 2003
  • Five denitrifying bacteria, which were identified as Pseudomonas sp., were isolated by the enrichment culture technique. The most effective denitrifying bacterium was named as Pseudomonas DWS, which was cultivated at anoxic condition. The optimal growth temperature and pH were 30$^{\circ}C$ and 7-8, respectively. Cell growth almost revealed a stationary phase at 18 hours after cultivation and nitrate was degrade 99.9% during this period. Therefore, it is suggested that Pseudomonas DWS could be effectively used for the biological treatment of wastewater containing nitrogen compounds.

질소안정동위원소비를 이용한 농촌지역 지하수의 질산성질소 오염원 추정

  • 배광옥;차장환;이강근;정형재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.459-462
    • /
    • 2003
  • 충청북도 증평에 위치한 문화마을 인근의 19개 지하수 관측정에서 시료를 채취하여 질산성질소 농도와 $\delta$$^{15}$ N 값, 암모니아성질소 농도와 $\delta$$^{15}$ N 값을 정량하였다. 그 결과 질산성질소에 의한 심각한 오염은 관찰되지 않으며, 질산성질소내 $\delta$$^{15}$ N이 +9.4~+36.8%0의 범위를 갖는 것으로 보아 계분이나 생활하수 혹은 두 가지 이상의 오염원이 동시에 작용함을 나타낸다. 연구지역의 $^{15}$ N 부화지수($\varepsilon$)은 -6.697%0로 탈질에 의한 범위를 만족한다. 암모늄의 질산화가 주요한 반응기작일 경우에 나타나는 암모늄 농도 감소에 따른 $^{15}$ N의 부화는 관찰할 수 없다.

  • PDF

A Study on the Removal of Nitrate Nitrogens by Redox Reaction of Zinc Ball (아연볼의 산화·환원 반응을 통한 연속식 질산성질소 처리에 관한 연구)

  • Kim, Joon Hwan;Kim, Jong Hwa;Song, Ju Yeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.487-494
    • /
    • 2017
  • Since nitrate nitrogen is quite stable in aqueous solution, considerable skill is required to remove it. Low concentrations of nitrate nitrogen are easily removed, while high concentrations of nitrate nitrogen are difficult to remove. This study is to show that nitrate nitrogen in the form of gaseous nitrogen can be removed by using zinc ball with a diameter of about 3mm and to test the removal characteristics of nitrate nitrogen under various reaction conditions. As a result of this study, the treatment efficiency of nitrate nitrogen by continuous treatment with zinc ball was about 80%. However, there is a problem that the wastewater must be maintained in an acidic atmosphere of about pH 2, and the treated wastewater must be neutralized and discharged.

Comparison of Nitrate and Fluoride Removals between Reverse-Osmosis, Nano-Flitration, Electro-Adsorption, Elecero-Coagulation in Small Water Treatment Plants (소규모 수도시설의 역삼투(RO), 나노여과(NF), 전기흡착(EA), 전기응집(EC) 공정의 질산성 질소 및 불소 이온 제거 성능 비교)

  • Han, Song-Hee;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.2027-2036
    • /
    • 2013
  • Comparison of removal performance between reverse osmosis(RO), nanofiltration(NF), electrocoagulation(EC) and electroadsorption(EA) for removal of nitrate and fluoride often exceeded the limits of water quality in small water treatment plants. Removals of nitrate and fluoride were 72-92% and 74-85% in RO, 5-15% and 1% in NF, 99% and 44% in EA equipped with MWCNT coated electrodes, 82% and 77% in EA equipped with Cu-MWCNT electrodes, and 11-46% and 69-99% in EC. Consequently, high removals of both ions were anticipated in RO. Effective removal of both ions are possible for EC, but great production of sludge is a big burden. EA equipped with the MWCNT electrodes showed a great fluctuation in removal efficiency, and electrode stability should be upgraded.