• Title/Summary/Keyword: 진료실

Search Result 281, Processing Time 0.022 seconds

The Noise Level Assessment of Dental Equipment (치과 의료장비의 소음 수준 평가)

  • Lee, Jeong-Suk;Han, Ye-Seul;Cho, Young-Sik
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.603-611
    • /
    • 2015
  • This research is aimed at cutting off hearing loss and other harmful factors due to noise and providing basic material for noise reduction plan. As the research method, this research assessed noise by measuring acoustic pressure level and frequency in various situation of non-treatment and treatment. As the measurement result, average noise degree of high speed handpiece of non-treatment, ultrasonic waves scaler, and low speed handpiece showed 58~66 dB(A). Average noise degree of scaling of treatment, tooth elimination, and denture adjust showed 73~81 dB(A). The result is inferior to recognized standards of noise induced hearing loss. But the result of assessing this with (noise rating) NR curve was NR-73~78, which exceeded general workplace noise standard. This level can cause hearing loss when exposed to a long time. Therefore, treatment office noise during dental treatment can cause psychological and physical damage in dental clinic employees, and it is urgently required to establish systematic and active noise reduction plan.

A Study Regarding Bacterial Contamination of Surfaces in Dental Offices (치과진료실 내 표면 세균 오염에 관한 연구)

  • Yun, Kyoung-Ok;Kim, Hye-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.4
    • /
    • pp.279-285
    • /
    • 2015
  • This study studied samples taken off surfaces at three sites (Unit chairs, light handles, cuspidors) of 19 dental hospitals and 28 clinics located in Gyeonggi-do and Incheon, South Korea. The bacterial contamination levels of surfaces were $44.82{\times}10^3CFU/mL$ in cuspidors, higher than in unit chairs ($5.47{\times}10^3CFU/mL$) and light handles ($16.28{\times}10^3CFU/mL$). The values were statistically higher at dental hospitals than at dental clinics, the greater number of patients being associated with the higher bacterial cell count in the cuspidors. The results of identifying the strains isolated purely from surfaces at dental clinic showed Gram positive 47.3% and Gram negative 52.7%. Among Gram positive, the most numberous bacteria were Micrococcus luteus (10.9%), Bacillus pumilus (3.6%), and Staphylococcus aureus (3.6%). Among Gram negative, the most numberous bacteria were Acinetobacter ursingii (5.5%), Brevundimonas diminuta (4.5%), Chryseobacterium (Flavo.) indologenes (CDC IIb) (4.5%), and Methylobacterium sp. (4.5%). This study measures the level of bacterial contamination and identifies the strains isolated in dental clinics. It recognizes the importance of infection control, and the results of the study may be considered as the basis for establishing specific plans for prevention of infection.

Full mouth rehabilitation of a patient with occlusal plane discrepancy with milling machine for clinic (진료실용 밀링머신을 이용한 교합평면 부조화 환자의 완전 구강 회복술)

  • Park, Ji-Man
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.2
    • /
    • pp.68-78
    • /
    • 2016
  • Recently, digital technology has become increasingly prevalent in the dental clinic. Using a milling machine for clinic, it is possible to produce provisional restoration inside the clinic. This can promote large clinical cases such as full mouth rehabilitation with the help of a tabletop scanner, which is capable of semi-adjustable articulator equipment, and a powerful dental CAD software with excellent user convenience. In this case report, a full-mouth rehabilitation was done with digital technology to a 55 year-old female patient, who has lost vertical dimension through the attrition, and has got inclined occlusal plane with unplanned and repeated dental reconstruction. Through the design and milling of the provisional restoration in the clinic and the duplication of these provisionals by double scanning technique, a good functional and esthetic result could be achieved.

The Infection Control of Dental Impressions (치과용 인상체의 감염 관리)

  • Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.183-193
    • /
    • 2013
  • The characteristics of dental treatment makes the dental staff frequently contact with patient directly. Also the daily use of high-handpieces, sharp instruments, and needles often causes bleeding on oral cavity. Therefore, the risk of cross transmission grows up. The pathogen from dental practice could spread on not only the practice itself but also the dental laboratory with contaminated impressions and prosthesis. Dental clinic staffs (dentists, dental hygienists and dental technicians) should recognize all the patients have a possibility of cross contamination, and try to prevent the transmission of infection by proper infection control. In this study, we review the articles about disinfection methods and chemical infection agents used for dental impressions, and try to figure out the suitable and effective infection control system of dental impressions.

미래의 대화

  • Park, In-Ho
    • 건강소식
    • /
    • v.2 no.11 s.14
    • /
    • pp.44-48
    • /
    • 1974
  • 이 단편 소설은「헨리ㆍ스틸」저「인간, 앞으로의 30년간」에서 초역한 것. 무태는 21세기에 진입하기 직전 그러니까 30년 후의 어느 날 어떤 병원 진료실에서 있을 의사와 환요의 대화를 가상적으로 쓴 것. 그러나 이 미래의 대화는 매우 과학적 분석에서 이루어진 것임.

  • PDF

Clinical considerations for complete denture relining (의치상 첨상재의 종류와 임상적 고려사항)

  • Young-Eun Cho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.39-45
    • /
    • 2024
  • The residual alveolar ridge below the denture base undergoes physiologic changes over time, which results in the existing dentures becoming less accurate with the residual alveolar ridge. In addition, changes of the occlusal plane, decreasing in vertical dimension and loss of denture retention and facial support can occur. Consequently, denture relining may be required to accommodate these changes and ensure an ongoing close fit. Relining a denture can be performed directly on the chairside using autopolymerizing relining materials or indirectly in the laboratory using heat-cured relining materials. A direct relining method is not only simple but also time and cost effective. However, irritation or burning sensation of the mucosa can occur, and poor bonding of the relining material to the denture base can be cited as disadvantages. The indirect relining method exhibits relatively high bonding strength between the relining material and the denture base, but the patient might experience discomfort during relining process period. This report will examine the characteristics of relining materials, including those used in the relining of CAD-CAM dentures, and explore the clinical considerations for relining procedures.

The Change of Health Service before and after the Unification of two Health Subcenters in a Rural Area (한 농촌지역 2개면 보건지소 통합전후 보건의료사업 변화 연구)

  • Sul, Sue-Jeong;Park, Hyang;Sohn, Seok-Joon;Park, Jong;Kim, Ki-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.25 no.2
    • /
    • pp.427-440
    • /
    • 2000
  • A comparative study was made about health resources, medical care service statistics and public health service statistics by health subcenters at Jangdong and Jangpyung townships, Jangheung County, Chollanamdo before and after the unification of two health subcenter to improve their function. 1. While two general physicians, one dentist, 4 nurse aids arid one oral hygienist were working at two health subcenters with simple facility with examination room and public health office in 1997 prior to the unification, in 1999 after the unification of two health subcenters 14 staff including a specialist physician, a general physician, a dentist, a herb hygienist, a radiology technician and a physical therapist were working in the new health subcenters equipped with appropriate facilities in two storey building. 2. In 1997 before the unification the yearly total income of two health subcenters was 78,815 thousand won(about 14,000 won per capita) and the amount was 140,376 thousand won(about 25,000 won per capita) in 1999 after the unification. And the income was used for operation of health subcenters excluding personnel expense. 3. While 90.5% of visitors to the health subcenters came for general medical care, and 91.6% came for the revisit before the unification, after the unification 71.2% came for general medical care, 10.8% for dental care, 16.5% for oriental physician's care, 29.7% for the first visit and 70.3% for revisit. Most common problem cared for was musculoskeletal disorder like arthralgia. Average treatment cost per person per month was 9,363 won before the unification and 8,309 won after the unification. 4. Through the comparison of execution rate of public health services before and after the unification. the practice rate of most health service among target population including visiting service for chronic illness, maternal and child health service and immunization service increased after the unification. The practice rate of tuberculosis control service, hypertension control and diabetes management was a little decreased. In conclusion, continuous effort to satisfy all persons in two townships and evaluation are necessary to coincide with the spirit of unification of two health subcenters.

  • PDF