• 제목/요약/키워드: 진동 인텐시티

검색결과 100건 처리시간 0.027초

무한 탄성 평판상의 기준점에 전달되는 진동인텐시티의 능동제어 (Active Control of Vibrational Intensity at a Reference Point in an Infinite, Elastic Plate)

  • 김기만
    • 한국소음진동공학회논문집
    • /
    • 제11권4호
    • /
    • pp.22-30
    • /
    • 2001
  • In this paper, active control of vibrational intensity at a reference point in an infinite, elastic plate was discussed. The plate is excised harmonically by a vibrating source, which has a vertical point force. The optimal condition of controller was investigated to minimize the vibrational intensity being transmitted from the vibrating source to a reference point. Hence the method of feedforward control was employed for the control strategy and then the cost function was evaluated to find the optimal control force. Three types of control force (Vertical force, Moment, and Coupling force (a set of vertical force and moment) ) and controller's positions were examined to define the optimal condition of the controller. The vibrational intensity at a reference point was found to be reduced down to a zero level, compared with the uncontrolled case. Especially maximum reduction of vibrational intensity was achieved when the controller was collinearly positioned between a vibrating source and a reference point.

  • PDF

연성평판의 면외 진동인텐시티 측정 (Measurements of the Out-of-Plane Vibration Intensity of Coupled Plate)

  • 전진숙;길현권;이병철;김창열;홍석윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.831-835
    • /
    • 2003
  • The objective of this paper is to suggest an experimental technique to measure the out-of-plane vibration intensity of a coupled plate. In order to measure the out-of-plane vibration intensity of the plate, the frequency response technique has been implemented. In this technique, the 2-D intensity vector at a measurement point has been estimate from the frequency response functions measured at 4 points in the neighborhood of the measurement point. The experimental result has been compared with a theoretical result. It showed that the experimental technique can be effectively used to measure the out-of-plane vibration intensity of plates.

  • PDF

평판의 면내 진동인텐시티 측정 (Measurements of the In-Plane Vibration Intensity of a Plate)

  • 전진숙;길현권;김창렬;이병철;홍석윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.816-820
    • /
    • 2003
  • The objective of this paper is to develop an experimental technique to measure the in-plane vibration intensity of a plate. In order to measure the in-plane vibration intensity at a data point, the frequency response functions for the 2 components of an acceleration vector are measured at each point of 4 points in the neighborhood of the data point. This experimental technique has been implemented to measure the in-plane vibration intensity of a plate. The experimental result has been compared with a theoretical result. It showed that the experimental technique can be effectively used to measure the in-plane vibration intensity of plates.

  • PDF

복합진동계의 진동 인텐시티 능동 제어 (Active Control of Vibrational Intensity in a Compound Vibratory System)

  • 김기만
    • 한국정밀공학회지
    • /
    • 제19권6호
    • /
    • pp.109-118
    • /
    • 2002
  • The vibrational intensity and the dynamic response of a compound vibratory system had been controlled actively by means of a feedforward control method. A compound vibratory system consists of a flexible beam and two discrete systems - a vibrating source and a dynamic absorber. By considering the interactive motions between discrete systems and a flexible beam, the equations of motion for a compound vibratory system were derived using a method of variation of parameters. To define the optimal conditions of a controller the cost function, which denotes a time averaged power flow, was evaluated numerically. The possibility of reductions of both of vibrational intensity and dynamic response at a control point located at a distance from a source were fecund to depend on the positions of a source, a control point and a controller. Especially the presence of a dynamic absorber gives the more reduction on the dynamic response but the less on the vibrational intensity than those without a dynamic absorber.

관통보와 평판의 연결 구조물에 대한 진동인텐시티 해석 (Vibration Intensity Analysis of Penetration Beam-plate Coupled Structures)

  • 홍석윤;강연식
    • 한국음향학회지
    • /
    • 제21권1호
    • /
    • pp.73-81
    • /
    • 2002
  • 본 논문에서는 중고주파영역에서의 진동해석기법인 파워흐름해석 법을 보와 평판이 연성된 구조물에 적용하기 위하여 무한보가 무한평판을 수직으로 투과하는 구조물에서의 파워투과반사계수를 파동전달법을 이용하여 구하였다. 이러한 파워투과반사계수를 실제 구조물에 적용하기 위해서는 파워흐름유한요소법으로의 활용이 필요하다. 이를 위해 본 논문에서는 파워투과반사계수를 이용하여 보 평판구조물을 위한 연결요소행렬식을 정립하였으며, 또한 보와 평판요소를 각각 해석할 수 있는 파워흐름유한요소해석 프로그램을 구성하고, 여기에 정립된 보와 평판간의 연결요소 행렬식을 대입하여 보와 평판이 연성된 구조물까지 해석이 가능한 프로그램으로 개발하였다. 이 프로그램을 이용하여 이상화한 선박의 선미부 구조물을 해석한 결과, 선박구조물에서 진동에너지분포를 구할 수 있었고, 진동 인텐시티를 통하여 구조물에서의 파워전달경로를 예측할 수 있었다.

반무한보의 진동 인텐시티 계측에 대한 연구 (A Study on Structural Intensity Measurement of Semi-infinite Beam)

  • 이덕영;박성태
    • 소음진동
    • /
    • 제7권1호
    • /
    • pp.43-53
    • /
    • 1997
  • This paper investigated the practical use for measuring the structural intensity (power flow per width of cross section) in a uniform semi-infinite beam in flexural vibration. The structural intensity is obtained as a vector at a measurement point, One-dimensional structural intensity can be obtained from 4-point cross spectral measurement, or 2-point measurement on the assumption of far field. The measurement errors due to finite difference approximation and phase mismatch of accelerometers are examined. For precise measurements, it would be better to make the value of k$\delta$(wave number x space between accelerometers) between 0.5 and 1.0. Formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained from 2- and 4-point measurement performed at 200mm (near field) and 400mm (far field) apart from excitation point in random excitation. the results are compared with the theoretical values and measured values of input power spectrum in order to verify the accuracy of structural intensity method, 2-point method is suggested as the practical structural intensity method.

  • PDF