• Title/Summary/Keyword: 진동환경 시험

Search Result 301, Processing Time 0.027 seconds

On-orbit Thermal Characteristic for Multilayered High Damping Yoke Structure Based on Superelastic Shape Memory Alloy for Passive Vibration Control of Solar Panels (태양전지판의 수동형 제진을 위한 초탄성 형상기억합금 기반 적층형 고댐핑 요크 구조의 궤도상 열적 특성 분석)

  • Min-Young Son;Jae-Hyeon Park;Bong-Geon Chae;Sung-Woo Park;Hyun-Ung Oh
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • In a previous study, a structure of a superplastic yoke consisting of a thin FR4 layer laminated with viscoelastic tape on both sides of a shape memory alloy (SMA) was proposed to reduce residual vibration generated by a deployable solar panel during high motion of a satellite. Damping properties of viscoelastic tapes will change with temperature, which can directly affect vibration reduction performance of the yoke. To check damping performance of the yoke at different temperatures, free damping tests were performed under various temperature conditions to identify the temperature range where the damping performance was maximized. Based on above temperature test results, this paper predicts temperature of the yoke through orbital thermal analysis so that the yoke can have effective damping performance even if it is exposed to an orbital thermal environment. In addition, the thermal design method was described so that the yoke could have optimal vibration reduction performance.

Characteristics of Electrochemical and Cavitation Damage after Sealing Treatment for Arc Thermal Sprayed Coating Layer (후처리된 아크 용사코팅 층의 전기화학적 및 캐비테이션 손상 특성)

  • Kim, Seong-Jong;Han, Min-Su;Park, Il-Cho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.300-300
    • /
    • 2014
  • 해양환경 하에서 대형 강구조물의 경우 장기간 부식손상을 방지하기 위해 아크 용사코팅 기술이 오래전부터 유용하게 이용되어 왔다. 아크 용사코팅 기술은 타 용사코팅 기술에 비해 경제성과 생산성이 뛰어나 대형 강구조물에 적용되고 있다. 용사재료로는 Al, Zn 또는 그 합금들이 주로 사용되어 강재에 대해 희생양극 방식효과를 나타낸다. 그러나 아크용사에 의해 적층된 코팅 층은 용사공정 중 불가피하게 수많은 기공과 산화물이 포함되어 내식성 및 내구성에 악영향을 미치게 된다. 따라서 본 연구에서는 알루미늄 합금의 용사코팅 층에 대하여 다양한 후처리를 통해 내식성과 더불어 내구성을 향상시키고자 하였다. 용사코팅은 알루미늄 합금 선재(1.6 ${\varnothing}$)를 사용하여 아크용사를 실시하였다. 용사 시 용사거리는 200 mm, 공기압력은 약 $7kg/cm^2$ 정도로 유지하면서 용사코팅을 실시하여 약 $200{\mu}m$ 두께로 코팅 층을 형성시켰다. 이후 용사코팅 층의 표면에 다양한 후처리재를 적용하였으며, 내구성을 평가하기 위하여 후처리 적용 전후 시험편에 대하여 캐비테이션 실험을 실시하였다. 캐비테이션 실험은 ASTM G32-92에 의거하여 주파수 20 kHz의 초음파 진동 장치(ultrasonic vibratory device)를 사용하였다. 그리고 시험편 표면과 발진 혼에 부착된 팁(tip)과의 거리는 1 mm로 일정하게 유지시킨 뒤, 캐비테이션 발생 시간을 변수로 하여 실험을 실시하였다. 손상된 용사코팅 층의 표면은 주사전자현미경과 광학현미경으로 관찰하였으며, 시험편 손상깊이는 3D 현미경으로 비교 분석하였다. 또한 캐비테이션 실험 전후의 무게를 측정하여 무게 감소량을 상호 비교하였다. 그리고 전기화학적 실험은 천연해수 속에서 자체 제작한 홀더(holder)를 이용하여 $0.33183cm^2$의 용사코팅 층만을 노출시켜 실시하였다. 그리고 기준전극은 은/염화은 전극을, 대극은 백금전극을 사용하였다. 분극실험을 통해 후처리 적용에 따른 용사코팅 층의 부식전위 및 부식전류밀도를 비교 평가하였다. 그 결과, 용사코팅 층에 의하여 강재에 대한 희생양극 방식전위가 확보되었으며, 후처리재가 적용된 용사코팅 층에서 내식성 및 캐비테이션 저항성이 향상되었다.

  • PDF

Development of Portable Memory Type Radiation Alarm Monitor (휴대용 메모리형 방사선 경보장치 개발)

  • Son, Jung-Kwon;Lee, Myung-Chan;Song, Myung-Jae
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.263-272
    • /
    • 1997
  • A Radiation Alarm Monitor has been developed and manufactured in order to protect radiation workers from over-exposure. A visual and audible alarm system has been attached to initiate evacuation when accident occurs such as an unexpected change of radiation level or an over-exposure. The Radiation Alarm Monitor installed with microprocessor can record the information of radiation field change between 90 min. before the alarm and 30 min. after the alarm and also provide the data to an IBM compatible computer to analyze the accidents and to set a counterplan. It features a wide detection range of radiation field(10 mR/h-100 R/h), radiation field data storage, portability, high precision (${\pm}5%$) due to self-calibration function, and adaption of a powerful alarm system. According to ANSI N42.17A, the most stringent test standards, performance tests were carried out under various conditions of temperature, humidity, vibration, and electromagnetic wave hindrance at Korea Research Institute of Standards & Science (KRISS). As a result, the Radiation Alarm Monitor passed all tests.

  • PDF

Electrochemical characteristics of WC-27NiCr and WC-10Co4Cr coated Al bronze (WC-27NiCr과 WC-10Co4Cr로 코팅된 동합금의 전기화학적 특성)

  • Kim, Min-Seong;Park, Jae-Cheol;Jang, Seok-Gi;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2011.05a
    • /
    • pp.80-80
    • /
    • 2011
  • 세계 기후 변화와 불안정한 유가 변화에 대응하고 국내산업의 저탄소 녹색성장을 위해 신재생에너지 개발이 활발하게 이루어지고 있다. 해양에너지 중에서 조류발전은 대규모 댐을 건설할 필요가 없어 비용이 적게 소요되고 특히 날씨 변화나 계절에 관계가 없고, 발전량이 예측 가능하므로 신뢰성 있는 에너지원으로 적용이 가능하다. 조류발전기 블레이드에 폴리머계 복합재료와 스테인리스강이 대부분인데, 이 재료는 특정 회사에서만 제작 가능하며, 충격에 약하고, 균열전파 속도가 빠르며, 대단히 고가이며, 수입에 의존하고 있는 실정이다. 이러한 조류발전에 사용되는 블레이드는 가혹한 부식, 캐비테이션 그리고 침식환경에 노출되어 있어 내구성이 우수한 제품개발이 대단히 중요하며, 조류발전 블레이드를 동합금으로 제작시, 내식성이 뛰어나며 구리의 특성상 해양생물 서식을 방지할 수 있고, 내캐비테이션 특성, 내구성, 가공성 및 유지보수가 용이한 장점이 있다. 이러한 동합금에 WC-27NiCr와 WC-10Co4Cr를 초고속 화염용사(HVOF)를 이용하여 코팅층의 캐비테이션 특성 및 전기화학적 거동을 연구하였다. 본 연구에서는 조류발전용 블레이드의 재료로 사용하려는 동합금에 WC-27NiCr와 WC-10Co4Cr이 용사코팅된 시험편을 사용하였다. 다채널 부식시험기인 WonA-tech WMPG-1000을 이용하여, 자연전위를 측정하였으며, 분극실험은 자체 제작한 홀더를 사용하여 $0.3318cm^2$를 노출 시켜 실험하였다. 기준전극은 은/염화은 전극을, 대극은 백금 전극을 사용하였다. 양분극과 음분극 실험을 통해 개로전위에서의 부식거동을 확인하였고, 정전위 실험도 실시하였다. 실험 종료 후 3D현미경 및 전자주사현미경(SEM)을 사용하여 코팅층 표면의 손상거동을 관찰하였다. 캐비테이션 실험은 ASTM-G32 규정에 의거하여 압전효과를 용한 진동발생 장치(RB 111-CE)를 사용하였다. 수조는 전기화학적 부식의 영향을 고려하여 아크릴로 제작하였고, 시험편은 실험장비에 맞게 파인커팅머신을 이용하여 $20mm{\times}20mm$로 절단하여 사용하였으며 혼과 대향하도록 하여 1mm 간격을 두어 실험하였다. 실험 실시 전, 미소전자저울을 사용하여 무게감소량을 측정하였으며 표면관찰을 통하여 캐비테이션 거동을 관찰하였다.

  • PDF

Recompression Properties of Sand in Post-Liquefaction Process According to Relative Density and Cyclic Loading History (상대밀도와 반복전단이력의 차이에 의한 모래의 액상화 후 재압축 특성)

  • Kwon, Youngcheul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.21-29
    • /
    • 2012
  • Ground failure by liquefaction can occur not only during shaking but also as the result of the post-liquefaction process after an earthquake. During the process of ground deformation and failure, excess pore water pressure in soil is redistributed, which can then lead to changes in the effective stress of soils. Therefore, in order to provide a further understanding of the phenomenon, we have to estimate the properties of effective stress during the recompression process in post-liquefaction as well, not only the total amount of pore water drained. The primary objectives of this study are to determine and compare the recompression properties in the post-liquefaction process in terms of the relationship between volumetric strains and mean effective stresses under the various conditions of relative density and shear stress history. In all experimental cases, the volumetric strains increase greatly in the low effective stress level, almost to the zero zone, and granite soil, which has fine grains, undergoes gradual changes in the relationship between volumetric strains and mean effective stresses compared with fine sand. And, we can also find that recompression properties in the post-liquefaction process by cyclic loading depend highly on the dissipation energy and maximum shear strain, and this fact can be obtained in all cases regardless of the existence of fine content, relative density, and loading history. Especially, granite soil having fine grains can be defined uniformly in the relationship between dissipation energy and maximum volumetric strain, while fine sand cannot be so uniformly defined.

The Vibration Effect by Induced Pulsation Pressure to the Fatigue Crack of the Dampener Fitting Welding Zone (항공기용 유압 펌프의 맥동 압력에 의한 감쇄기 용접부위 균열 개선 연구)

  • Shin, Jae Hyuk;Kim, Tae Hwan;Kang, Gu Heon;Ha, Do Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.677-687
    • /
    • 2017
  • Aircraft can often be exposed to a variety of environments and vibrations such as engine, hydraulic pump, aerodynamic force. These may cause cracking and destruction of the mechanical structure and sub-components by high-cycle fatigue. The axial piston type pump which is usually applied to the aircraft hydraulic pump can be necessarily accompanied by the fluid pulsation by continuous rotation of the axial piston. The fatigue crack was identified at the dampener fitting welding zone to prevent vibration damping during the running of aircraft equipped with this type of pulsation hydraulic pump. In order to understand the root cause of this matter, fracture and component analyses were carried out and also integral type dampener fitting was applied to prevent recurrence of the crack as a subject of design improvements. Structural integrity stress analysis, fatigue analysis, qualification test and aircraft system equipped test was conducted to verify the design validity in application to integral type dampener fitting. The test results were sufficiently satisfactory with the demand lifetime of the material from the various types of test as conducted and the subject of design improvement in this study could be objectively evaluated that shall be applied to the operational aircraft.

Development of Impact Factor Response Spectrum with Tri-Axle Moving Loads and Investigation of Response Factor of Middle-Small Size-RC Slab Aged Bridges (3축 이동하중을 고려한 충격계수 응답스펙트럼 개발 및 중소규모 RC 슬래브 노후교량 응답계수 분석)

  • Kim, Taehyeon;Hong, Sanghyun;Park, Kyung-Hoon;Roh, Hwasung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.67-74
    • /
    • 2019
  • In this paper the response factor is investigated for middle and small size-RC slab aged bridges. The response factor consists of static and dynamic response factors and is a main parameter in the frequency based-bridge load carrying capacity prediction model. Static and dynamic response factors are determined based on the frequency variation and the impact factor variation respectively between current and previous (or design) states of bridges. Here, the impact factor variation is figured out using the impact factor response spectrum which provides the impact factor according to the natural frequency of bridges. In this study, four actual RC slab bridges aged over 30 years after construction are considered and their span length is 12m. The dynamic loading test in field using a dump truck and eigenvalue analysis with FE models are conducted to identify the current and previous (or design) state-natural frequencies of the bridges, respectively. For more realistic considerations in the moving loading situation, the impact factor response spectrum is developed based on tri-axle moving loads representing the dump truck load distribution and various supporting conditions such as simply supported and both ends fixed conditions. From the results, the response factor is widely ranged from 0.21to 0.91, showing that the static response factor contributes significantly on the results while the dynamic response factor has a small effect on the result. Compared to the results obtained from the impact factor response spectrum based on the single axle-simply supported condition, the maximum percentage difference of the response factors is below 3.2% only.

Pseudo-DC Resistivity Survey for Site Investigation at Urban Areas with Ambient Electrical Noises (전기잡음 간섭이 있는 도심지 지역 탐사를 위한 유사직류 전기비저항 기법)

  • Joh, Sung-Ho;Kim, Bong-Chan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1C
    • /
    • pp.37-44
    • /
    • 2010
  • Recently, urban retrofit and extension, development of new buildings and facilities, and construction of underground structures like subway tunnels in urban areas give rise to significance of site investigation at urban areas. However, ambient electric noises, traffic vibrations, embedded objects work as obstacles to high-quality and accuracy in site investigation at urban areas. In this paper, a new technique called the pseudo-DC resistivity survey (in brief, PDC-R) was proposed to minimize the adverse effect of ambient electrical noises in resistivity survey. PDC-R technique utilizes an AC current with frequency range of 0.1 to 1.0 Hz rather than DC current, which is used for conventional resistivity survey. The motivation of using low-frequency AC current is to avoid 60-Hz components or its multiples in the resistivity survey which ambient noises are mostly composed of. The implementation of PDC-R technique also included the parametric study on skin effect, frequency effect and current-level effect, which led to the determination of optimal values of frequency and current level for PDC-R survey. The reliability and feasibility of PDC-R technique was verified through field tests, accompanied by the comparison with DC resistivity survey and CapSASW tests.

The Research for effect of lubricant oil aging on environmental performance (자동차 윤활유의 성상 및 열화가 환경성에 미치는 영향 연구)

  • Kim, Jeong-Hwan;Kim, Ki-Ho;Ha, Jong-Han;Jin, Dong-Young;Myung, Cha-Lee;Jang, Jin-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.12-24
    • /
    • 2017
  • The main purpose of this research is for the investigation on the impact of engine oil aging on PM and DPF. It is widely known that lubricant specifications and consumption from an ICE have significantly influenced on the regulated and unregulated harmful emissions as the engine operating conditions. Considering DPF clogging phenomena with lubricant-derived soot/ash components, simulated aging mode for the DPF was newly designed for engine dynamometer testing. PM/ash accumulation cycle were developed in reflecting real-world engine operating conditions for the increment of engine oil consumption and natural DPF regeneration for the ash accumulation. The test duration for DPF aging reached around 100hrs with high- and low-SAPS engine oils, respectively. Using high SAPs engine oil made more PM/ash accumulation compared with low SAPs engine oils and it could accelerate fouling of EGR in engine. Fouling of EGR made effects on more harmful exhaust gases emissions. The test results on engine lubricant under engines operating conditions will deliver for the establishment of regulated and unregulated toxic emissions policy, lubricant quality standard.

Design, Implementation and Test of Flight Model of S-Band Transmitter for STSAT-3 (과학기술위성 3호 S-대역 송신기 비행모델 설계, 제작 및 시험)

  • Oh, Seung-Han;Seo, Gyu-Jae;Lee, Jung-Soo;Oh, Chi-Wook;Park, Hong-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.6
    • /
    • pp.553-558
    • /
    • 2011
  • This paper describes the development and test result of S-band Transmitter flight model(FM) of STSAT-3 by satellite research center(SaTReC), KAIST. The communication sub-system of STSAT-3 is consist of two different frequency band channels, S-band for Telemetry & Command and X-band for mission data. S-band Transmitter(STX) functionally made of modulator, frequency synthesizer, power amp and DC/DC converter. The transmission data is modulated by FSK(Frequency Shift Keying) and the interface between spacecraft sub-module and STX is RS-422 standard method. The FM STX is based on modular design. The RF output power of STX is 1.5W(31.7dBm) and BER of STX is under $1{\times}10^{-5}$ which meets the specification respectively. The FM STX is delivered Spacecraft Assembly, Integration and Test(AIT) level through the completion of functional Test and environmental(vibration, thermal vacuum) Test successfully.