• Title/Summary/Keyword: 진동절연

Search Result 214, Processing Time 0.023 seconds

Design of Isolation-Type Matching Network for Underwater Acoustic Piezoelectric Transducer Using Chebyshev Filter Function (체비셰프 필터함수를 이용한 수중 음향 압전 트랜스듀서의 절연형 정합회로 설계)

  • Lee, Jeong-Min;Lee, Byung-Hwa;Baek, Kwang-Ryul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.491-498
    • /
    • 2009
  • This paper presents the design method of an impedance matching network using an isolation transformer and the Chebyshev filter function for the high efficiency and the flat power driving of an underwater acoustic piezoelectric transducer. The proposed impedance matching network is designed for minimizing the reactance component of transducer and having the flat power response in the wide frequency range. We design a low pass filter with ladder-type circuit using the Chebyshev function as standard prototype filter function. In addition, we design the impedance matching network which is suitable for the equivalent circuit of transducer and the turn ratio of transformer through the bandpass frequency transformation. The proposed method is applied to the simulated dummy load of the tonpilz-type transducer operating in the middle frequency range. The simulation results are compared with the measured characteristics and the validity of the proposed method is verified.

The removal of iron oxides from raw materials by superconducting magnetic separator (초전도 자기분리를 이용한 원료에서의 철산화물 제거)

  • Kwon, Jun-Mo;Ha, Dong-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.21-21
    • /
    • 2010
  • 현재 시대에는 자원의 부족으로 인하여 원재료의 낮은 등급을 정제하는 것이 중요하다. 자기분리 기술이 산업 계 원재료들의 정제에 적용되는 것이 기대된다. 예를 들면 고순도의 유리나 절연체를 제작하기 위한 원재료에서 철산화물의 제거는 매우 중요하다. 자기를 띠는 입자들과 자기분리 필터 와이어 사이에 발생하는 끌어당기는 힘은 다른 자기분리와 비교 할 때 초전도 자기분리에서 훨씬 강하다. 초전도 마그네트를 이용하여 높은 자기장을 형성하기 때문에 일반 자기분리의 자성 입자 포획력을 능가한다. 본 연구에서는 습식 조건에서 산업계 원재료로부터 철계 산화물을 제거하기 위해서 초전도 자기문리를 사용하여 실험하였다. 실험에 사용된 시료는 유리원료로 사용되는 2종류로 시료A는 0.1 ~ 0.3 mm의 평균입도를 갖는 모래형상이며 시료B는 평균입도 0.03 ~ 0.1 mm의 고운모래 형태이다. 자기분리를 위해 상온에서 100 mm의 직경을 갖는 600 mm의 높이의 전도냉각형 Nb-Ti 초전도 마그네트를 사용하였으며 시료를 위에서 공급하고 아래로 배출되도록 수직형으로 설치하였다. 시료 500 g과 증류수 2 L를 혼합하여 교반시키고 6 T의 자기장 하에서 실험하였다. 자기분리 필터는 초전도 마그네트에서의 자기장의 분포를 해석하여 디자인하였다. 자기분리 필터의 자기적 특성을 알아보기 위해 진동시료형 자력계를 사용하였다. 산업계 원재료는 X선 형광분석기를 사용하여 성분을 분석하였다. 산업계 원재료를 이용하여 초전도 자기분리를 실시한 결과 철계 산화물은 시료A에서 43.5 %제거되었으며 시료B에서는 77.3%제거되었다.

  • PDF

Analysis and Design of a Pneumatic Vibration Isolation System: Part I. Modeling and Algorithm for Transmissibility Calculation (공압 제진 시스템의 해석과 설계: I. 모델링과 전달율 계산 알고리즘)

  • Moon Jun Hee;Pahk Heui Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.127-136
    • /
    • 2004
  • This paper is the first of two companion papers concerning the analysis and design of a pneumatic vibration isolation system. The design optimization of the pneumatic vibration isolation system is required for the reduction of cost, endeavor and time, and it needs modeling and calculation algorithm. The nonlinear models are devised from the fluid mechanical expression for components of the system and the calculation algorithm is derived from the mathematical relationship between the models. It is shown that the orifice makes the nonlinear property of the transmissibility curve that the resonant frequency changes by the amplitude of excited vibration. Linearization of the nonlinear models is tried to reduce elapsed time and truncation error accumulation and to enable the transmissibility calculation of the system with multi damping chambers. The equivalent mechanical models generated by linearization clarify the function of each component of the system and lead to the linearized transfer function that can give forth to the transmissibility exactly close to that of nonlinear models. The modified successive under-relaxation method is developed to calculate the linearized transfer function.

A Study on the Noise Source Identification of Refrigerator Compressor (냉장고용 압축기 소음원 규명에 관한 연구)

  • O, Jae-Eung;Lee, Chang-Ho;Lee, Myeong-Ryeol;Yeom, Seong-Ha
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.48-57
    • /
    • 1987
  • It is well known that the major noise source of Refrigerator is compressor, and due to the tendency of higher quality and more lighting of manufactured goods, the importance of prevention and reduction of a noise is increasing. In this paper, in order to prevent and reduce such a noise, sound pressure level and acoustic intensity are measured for compressor, and the result of these measurements, the noise radiation characteristics of compressor are reconized. And the experimental modal analysis is applied to the compressor to identify the noise sourcce. As the results of this study, we come to know that the spring, which is used to reduce vibration, does not reduce vibration efficiently, and compressor shell and its mounting system effect the noise radiation.

  • PDF

An Experimental Study on the Vibration of Rubber Mounts for Naval Shipboard Equipments (함정용 고무마운트의 진동에 대한 실험적 연구)

  • Lee, Hyun-Yup;Shin, Su-Yong;Chung, Jung-Hoon;Kwak, Jeong-Seok;Lew, Jae-Moon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.2
    • /
    • pp.165-170
    • /
    • 2009
  • Most of the naval shipboard equipments strongly require isolation devices to keep their performance and durability from severe noise and vibration loading. The rubber mount is well-known as one of most effective way to isolate major equipments from noise and vibration. The performance of the rubber mount is determined by characteristics of shock stiffness and vibration stiffness and the frequency range of interest is up to several Kilo Hz in navy vessels. In this study, an vibration experiment method for the rubber mount has been developed as a foundation work for assessing dynamic stiffness up to high frequency. Also experiments for a typical rubber mount has been carried out and the results has been discussed.

Seismic and Stress Analysis of 72.5kV GIS for Technical Specification of KEPCO (72.5kV GIS 전력 장비의 KEPCO 기준 내진 및 응력 해석)

  • Lee, Jae-Hwan;Kim, Young-Joong;Kim, So-Ul;Bang, Myung-Suk
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.3
    • /
    • pp.207-214
    • /
    • 2017
  • High voltage electric power transmitter GIS(Gas Insulated Switchgear) above 72.5kV needs to satisfy domestic Korean peninsular standard(ES-6110-0002) in KEPCO with respect to normal and special operation conditions which include internal gas pressure, dead weight, wind and seismic load. Some other requirements not described in Korean standard can be applied from other international standards such as IEC(International Electronical Committee) 62271-203 and 62271-207. The GIS is a kind of pressure vessel structure made of aluminum and filled with SF6 gas of internal pressure 0.4~0.5MPa. Finite element analysis of GIS is performed with such operational loads including seismic loading and the stability and reliability is determined according to ASME BPVC(Boiler and Pressure Vessel Code) SEC. VIII standard where the allowable stress level of the pressure vessel is suggested. The result shows that the stress of GIS is satisfied the allowable stress level and the safety factor is about 2.3 for Korean peninsular standard.

A Study on the Analysis of Heat and Metallurgical Structure of Connection Parts for Residual Current Protective Devices (저압용 누전차단기 접속부의 발열 및 금속 조직 분석에 관한 연구)

  • Choi Chung-Seog;Shong Kil-Mok;Kim Dong-Ook;Kim Dong-Woo;Kim Young-Seok
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.57-63
    • /
    • 2004
  • We investigated heat properties of connection terminal in residual current protective devices(RCD) according to contact pressure for low voltage appliance. And we analyzed voltage and current waveform and oxide propagation when the poor-contact happened between terminal and wire. When contact pressure between terminal and connection wire was not applied, the heat was generated and an oxide was formed on the surface of the wire. The temperature of the insulation surrounding terminal was ascended sharply by poor-contact, micro-sparks and continuous arc sound happened in interior terminal. When the poor-contact by vibration occurred inner conductor of terminal and wire, an oxide was propagated on contact surface and the temperature was increased at 869℃. Thus, we found that the risk of electrical disaster is high in terminal and connection wire parts.

A Study on Dynamic Modeling of the Vibration Isolation System for the Ultra Precision Measurement (초정밀작업을 위한 제진시스템의 동역학 모델링 연구)

  • Son, Sung-Wan;Jang, Sung-Ho;Baek, Jae-Ho;Chun, Chong-Keun;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • The anti-vibration tables that use air suspensions as dampers have been widely used due to their high anti-vibration performance in wide frequency band. However, they face a problem of easily accelerating the vibration when triggered by external force because their air suspensions have low rigidity and dampness. In response, there has been a study on active/semi-active dampers that use only the passive components like air suspensions to complement the passive-control format. Thus, we have dynamically analyzed the active/semi-active control of such passive anti-vibration tables. To demonstrate the anti-vibration table's control system, we have also constructed a kinetic model based on the physical characteristics of an anti-vibration table with 6 degrees of freedom and verified its applicability through analysis and experiments.

The Patent Analysis of the Treatment Technology of Asbestos Wastes (석면 폐기물 처리 특허기술 분석)

  • Kim, Jong-Heon;Cho, Jin-Dong;Lee, Sang-Kwon;Cha, Seong-Ki
    • Economic and Environmental Geology
    • /
    • v.44 no.5
    • /
    • pp.451-462
    • /
    • 2011
  • Asbestos or its applications have been used for long times and for various purposes in our life because of their merits, namely fire resistance, electric insulation and chemical resistance capacity etc. Despite of theses many merits, one of the problems of asbestos is shown toxicity according to its fiber type. So we need data to solve about this problem. In this paper, we study on the technical method of asbestos waste treatment and on the trends of asbestos researches and developments by the analysis of its patents and DWPI database materials. As a result, the asbestos-waste treatment data in the its related patents is used 267 cases to analyze. These data are divided into 86(32.5%) cases of solid waste disposal(B09B). 41(16.6%) cases of separation(B01D) and 27(10.2%) of lime, magnesia, slag, cement and their composites(C04B).

Evaluation Using Dynamic Characteristic of Steel Structures under Periodical Impact Loads (주기적 충격하중을 받는 강 구조물의 구조건전성 평가)

  • Kim, Kang Seok;Nah, Hwan Seon;Lee, Hyeon Ju;Lee, Kang Min;Yoo, Kyung Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.120-128
    • /
    • 2011
  • Recently, safety diagnosis of the existing structures has been emerged as important issue. In particular, systematical and precise safety diagnostics for steel structures for power substation, have been required. Steel structures for power substation are under the periodical impact loads from operations of gas insulated switchgear. These loading condition accelerates damage and aging of structure. The objective of this research is to evaluate damage of structure under periodical impact loads. To evaluate the integrity of structures as organizing mathematical models including the dynamic characteristics of structures, Frequency Domain Decomposition method was choiced and an algorism was proposed. For verifying this methods and algorism, a mathematical model is composed of the development of a variety of reverse analysis and a signal processing technology reflecting physical damage of structures. A series of analysis and test results indicatge that proposed method has a confidence for applying a filed test. Therefore, it is expected to be able to take advantage of system identification to detect damage for the maintenance and management of steel structures under periodical impact loads such as power substation.