• Title/Summary/Keyword: 진동절연기

Search Result 60, Processing Time 0.024 seconds

A Study on the Support Toning Method of High-Speed Chip-Mounter (고속 표면실장기의 지지부 개선 방법에 관한 연구)

  • Oh, Chang-Kyun;Park, Heung-Keun;Park, Jin-Moo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.597-602
    • /
    • 2006
  • In this paper, a proper support tuning method is established by identifying the dynamic characteristics of the machine, the floor. and the inertia force. Also, the limitation of a passive isolation is presented. To simplify the dynamic analysis and to establish a proper design method for supporting system, each of the machine and the floor is modeled as a single degree of freedom spring-mass-damper system under careful investigation of the dynamic characteristics of each system and appropriate assumptions. Then, the dynamic behavior of a 2DOF system and the effect of the mass and the damping are investigated. Also, the characteristics of motion profiles are investigated. In addition, a quasi-static analysis on the transmitted force through support is performed and related tests are performed.

  • PDF

A Study on the Improvement of Voltage Measuring Method of 22.9 kV-y Distribution Lines (22.9 kV-y 배전선로의 전압계측방법 개선에 관한 연구)

  • Kil, Gyung-Suk;Song, Jae-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.293-299
    • /
    • 1998
  • An objective of this study is to develop a voltage measuring device that uses a gas-filled switch (GS) on 22.9 kV-y extra-high voltage distribution lines. The voltage measuring device proposed in this paper is a kind of capacitive divider which consists of a detecting electrode attached outside of the bushing of GS, an impedance matching circuit, and a voltage buffer. It can be easily installed in an established GS without changing the structure. For the calibration and application investigations, the voltage measuring device was set up in the 25.8 kV 400 A GS, and a step pulse generator having 5 ns rise time is used. As a result, it was found that the frequency bandwidth of the voltage measuring device ranges from 1.35 Hz to about 13 MHz. The error of voltage dividing ratio which is evaluated by the commercial frequency voltage of 60 Hz was less than 0.2%. In addition, voltage dividing ratio in the commercial frequency voltage and in a non-oscillating impulse voltage were compared, and their deviation were less than 0.7%.

  • PDF

Designing isolation system for Engine/Compressor Assembly of GAS Driven Heat Pump (가스 엔진 구동 열펌프 실외기 엔진/압축기 진동 절연 설계)

  • Lenchine Valeri V.;Ko, Hong-Seok;Joo, Jae-Man;Oh, Sang-Kyoung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1128-1133
    • /
    • 2003
  • A gas driven heat pump (GHP) core design comprises internal combustion engine, compressors incorporated to a cooling/heating system, rubber mountings and belt transmissions. Main excitation farces are generated by an engine, compressors themselves and belt fluctuation. It leads to high vibration level of the mount that can cause damage of GHP elements. Therefore an appropriate design of the mounting system is crucial in terms of reliability and vibration reduction. In this paper oscillation of the engine mount is explored both experimentally and analytically. Experimental analysis of natural frequencies and operational frequency response of the GHP engine mounting system enables to create simplified model for numerical and analytical investigations. It is worked out criteria f3r vibration abatement of the isolated structure. Influence of bracket stiffness between engine and compressors, suspension locations and damper performance is investigated. Ways to reduce excitation forces and improve dynamic performance of the engine-compressor mounting system are considered from these analyses. Implementation of the proposed approach permits to choose appropriate rubber mountings and their location as well as joining elements design A phase matching technique can be employed to control forces from main exciters. It enables to changing vibration response of the structure by control of natural modes contribution. Proposed changes lead to significant vibration reduction and can be easily utilized in engineering practice.

  • PDF

A Study on the improvement of damping and optimal design of beam flexure for the passive vibration isolator (수동형 음강성 저주파 제진기의 감쇠 성능 향상과 빔 유연체의 최적 설계에 관한 연구)

  • Lee, Gil-Yong;Chang, Hee-Doh;Park, Young-Ho;Park, In-Hwang;Han, Dong-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.189-195
    • /
    • 2008
  • The vibration isolator system(VIS) which has very low natural frequency could be designed by applying an axial compressive force to the beam-column flexure(BCF). In this paper a new shape of the BCF is suggested. It has stepwise axially varying properties by viscoelastic damping layer. So it has internal structural damping by damping layer during deformation. First the analytic solution is obtained for the BCF. And its critical load, buckling mode, stiffness and stress distributions are investigated. Also the dynamic properties of the VIS consist of the damping layered BCF are studied. Finally the optimal design procedure of damping layered BCF for the VIS is suggested. The improved performance of suggested VIS is verified by some experiments.

  • PDF

A Study of Noise Characteristics Induced by Slab Vibration for the Elevated Railway Station (선하역사의 슬래브 진동에 의한 소음방사 특성에 관한 연구)

  • Kim, Jin-Ho;Jang, Dongdoo;Ji, Yong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3557-3566
    • /
    • 2015
  • In the case of elevated railway station in which railway is connected with superstructure of station, vibration and noise level is relatively higher than those of general structure type station due to structural characteristic which transmits vibration directly. Therefore, characteristic understanding of structural vibration and accompanying structure cause noise and establishment of reduction plan through the results are in need. Test and analysis are performed in this research to consider correlativity between structural vibration and accompanying structure cause noise when external forces are applied on standard slab and floating slab which is able to isolate vibration. By producing and loading on standard and floating slab, vibration and noise response are measured while simulation using numerical analysis, finite element method and SEA method is performed. The results about structural dynamic behavior of slab, correlativity between structural vibration and noise, reduction performance of floating slab is deduced through the analysis of tests.

A Study on the Noise Source Identification of Refrigerator Compressor (냉장고용 압축기 소음원 규명에 관한 연구)

  • O, Jae-Eung;Lee, Chang-Ho;Lee, Myeong-Ryeol;Yeom, Seong-Ha
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.48-57
    • /
    • 1987
  • It is well known that the major noise source of Refrigerator is compressor, and due to the tendency of higher quality and more lighting of manufactured goods, the importance of prevention and reduction of a noise is increasing. In this paper, in order to prevent and reduce such a noise, sound pressure level and acoustic intensity are measured for compressor, and the result of these measurements, the noise radiation characteristics of compressor are reconized. And the experimental modal analysis is applied to the compressor to identify the noise sourcce. As the results of this study, we come to know that the spring, which is used to reduce vibration, does not reduce vibration efficiently, and compressor shell and its mounting system effect the noise radiation.

  • PDF

다중 전원을 이용한 듀얼 랑뮤어 프루브 시스템을 통한 플라즈마 진단

  • Kim, Hyeok;Lee, U-Hyeon;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.214-215
    • /
    • 2011
  • RF 플라즈마의 경우 일반적인 싱글 랑뮤어 프루브를 사용하여 I-V 파형을 구하는 경우에, 우리는 시평균한 값만을 구할 수 있다. 일반적인 플라즈마 반응 챔버의 구조상, 양 전극의 크기가 다르기 때문에, 시간에 따라 진동하는 플라즈마 포텐셜의 형태는 정확한 사인파의 형태가 아니다. 그렇기 때문에 플라즈마 포텐셜에 따라서 진동하는 데이터를 시평균한 값에는 DC 오프셋 성분이 나타난다. 이러한 DC 오프셋값은 랑뮤어 프루브를 통한 플라즈마 포텐셜 측정시에 오차로 나타난다. 우리는 DC 오프셋에 의한 에러값을 보정하기 위해 멀티 프루브를 사용할 수 있다. 가장 흔하게 쓰이는 듀얼 랑뮤어 프루브의 경우를 살펴보면, 내부의 전원이 플로팅되어 있으며 전압인가를 위한 회로 또한 접지에서 절연되어 있기 때문에, 플라즈마 포텐셜이 시간에 따라 흔들려도 전체적인 전위가 플라즈마 포텐셜과 함께 움직이기 때문에, 앞에서 말한 DC 오프셋에 의한 오차를 줄일 수있다는 장점이 있다. 그러나, 이를 위하여는 회로의 절대적인 플로팅이 필요하지만 실제 듀얼 랑뮤어 프루브의 전원 회로를 구현시에는, 트랜스포머 등을 사용하여 회로를 절연시켜도 회로에 기생적으로 발생하는 콘덴서 성분 때문에 플로팅에 영향을 받을 수 있다. 또한 양극과 음극 사이의 내부 임피던스가 다르게 나타난다. 실제로 기존의 듀얼 랑뮤어를 가지고 RF 플라즈마를 측정할 때에, 듀얼 랑뮤어 프루브의 두 팁 간에 서로 다른 전압-전류 파형이 나타나곤 한다. 이러한 두 팁간의 전압-전류 파형의 차이는 두 팁이 물리적으로 완전히 동일한 구조를 가질 수 없기 때문에 발생 하기도 하지만, 위에서 밝힌 원인에 의해서도 발생한다. 이로 인하여 듀얼 랑뮤어 프루브에 의한 I-V 파형은 이론 상 원점을 대칭으로 한 기함수의 형태이어야 하는데, 실제 측정 결과를 보면 이러한 대칭 형태의 모양을 보기 힘들다. 우리는 이에 이를 보정하기 위하여 위상이 180도 차이가 나는 두 개의 삼각파 발생 전원을 각각 듀얼 랑뮤어 프루브의 양 팁에 인가하여 두 팁 간의 내부 저항과 기생 임피던스 등을 일치시킨 프루브를 디자인하였으며 이 프루브를 이용한 실험에서, 비교적 완벽하게 원점에 대하여 대칭하는 I-V 커브를 구할 수 있었다. 이에 이 논문에서는 새로운 회로와 이 회로로 이루어진 듀얼 랑뮤어 프루브를 사용하여 플라즈마를 진단하는 방법에 대하여 기술한다.

  • PDF

Vibration Control of CD-ROM Feeding System Using ER Fluids (ER 유체를 이용한 CD-ROM 피딩 시스템의 진동 제어)

  • 김형규;임수철;최승복;박영필
    • The Korean Journal of Rheology
    • /
    • v.11 no.2
    • /
    • pp.97-104
    • /
    • 1999
  • This paper presents vibration control of a drive feeding system consisting of a new type of CD-ROM(compact discread only memory) mount using electro-rheologocal(ER) fluid. Chemically treated starch particles and silicon oil are used for ER fluid. and its field-dependent yield stresses are experimentally distilled under both the shear and the flow modes. On the basis of the yield stress, an appropriate size of ER CD-ROM mount adapted to conventional feeding system is designed and manufactured. Vibration isolation performance of the proposed mount is evaluated in the frequency domain and compared with that of conventional rubber mount. The ER CD-ROM mount is then installed to the drive feeding system and the system equation of motion is derived. Following the formulating the sky-hook controller, computer simulation is undertaken in order to evaluate vibration suppression of the feeding system subjected to various disturbances(excitations).

  • PDF

Study of the Vibration and Shock Isolation for HEV Battery Pack (특수임무 차량 배터리 팩 진동/충격 저감 설계에 대한 연구)

  • Kim, Man-Dal;Jang, Duk-Jin;Lee, Sung-Jun;Hong, Seong-Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.10
    • /
    • pp.813-820
    • /
    • 2016
  • Hybrid Electric Vehicles (HEVs) are developed to be operated with two kinds of power source (Diesel Engine and Electric Motor with Rechargeable High Voltage Battery Pack). HEVs for military vehicle require high reliability to provide stable powers under serious environment such as vibration and shock. To ensure normal operation of battery pack under serious environment such as vibration and shock, the high voltage battery pack needs to have appropriate dynamic characteristics. This paper presents a design procedure for high voltage battery pack with such characteristics. An isolator design is proposed to reduce vibration and shock. Associated random vibration and shock response of the high voltage battery pack are simulated under conditions suggested by MIL specifications. Its dynamic characteristics and vibration and shock responses are validated with experiments.

The study of PTFE isolator equipped to small satellite launch vehicle to reduce the separation shock (소형 인공위성 발사체 충격저감용 PTFE(테프론) 소재 아이솔레이터 연구)

  • Jeong, Ho-Kyeong;Youn, Se-Hyun;Seo, Sang-Hyun;Jang, Young-Soon;Yi, Yeoung-Moo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.358-362
    • /
    • 2006
  • Pyro-shock generally refers to the severe mechanical transients caused by the detonation of an ordnance device on a structure. Such device on a structure, including linear explosive, and point explosive are widely used to accomplish in-flight separation of structural elements on aerospace vehicle. And they are a significant cause of launch vehicle failures. The launch vehicle being developed in Korea also uses the explosive for separation events. In this paper, the isolator equipped to small satellite launch vehicle made of PTFE(Teflon) is developed to reduce the separation shock. The test to measure dynamic stiffness of PTFE isolator is performed. This test enables us to find the frequency range of PTFE isolator. And,, pyre-shock test using explosive to evaluate the performance of PTFE isolator is executed. from this study, the isolator conformed to frequency range and load requirement is developed using PTFE instead of rubber.

  • PDF