• 제목/요약/키워드: 진동사용성 평가

Search Result 392, Processing Time 0.026 seconds

Estimation of Stiffness Limit for Railway Bridge Vibration Serviceability (진동사용성을 고려한 철도교량구조물의 강성한계 분석)

  • Jeon, Bub-Gyu;Kim, Nam-Sik;Kim, Sung-Il
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.5
    • /
    • pp.489-498
    • /
    • 2008
  • In general, deflection limit criteria of bridge design specifications have been considered based on static serviceability and structural stability. Dynamic serviceability induced from bridge vibration actually has not been included in the criteria. Thus, it is necessary for deflection limit to be considered in order to check dynamic service- ability on bridge vibration. In this study, The allowable displacement of Korea Railway Bridge Design Specifications is compared to the frequency domain comfort limit and analyzed france code and japanese code. Korea Railway Bridge Design Specifications is regulated based on the train speed. Such is because the vibration time duration is partly considered. but this criteria is not satisfied with comfort limit. and, it is estimated to be capable to provide deflection limit considering dynamic serviceability. In order to evaluate the dynamic serviceability of various types of railway bridges in current public were selected and their dynamic signals were measured. and the result of the bridge-train interaction analysis according to the changes in bridge stiffness was compared to the comfort limit to suggest the stiff-ness limit to the dynamic serviceability, which should conveniently be applied at the field.

Use of dynamic measurement for pavement condition evaluation (도로포장상태 평가를 위한 진동계측의 이용)

  • 김수일
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1990.10a
    • /
    • pp.21-26
    • /
    • 1990
  • 포장도로는 신설된 후 계속적인 차량의 통행과 기후 조건의 변화등으로 시 간이 경과함에 따라서 그 상태가 저하된다. 따라서 포장도로는 일정기간이 지난 후에는 쾌적한 차량의 통행을 보장하기 위하여 유지보수를 실시하여야 한다. 이러한 유지보수를 효율적이고 과학적으로 수행하는 것은 대단히 중요 하다. 미국과 같은 선진국의 경우 도로 신설의 투자비 보다 유지보수에 사용 되는 예산이 더 많아지고 있는데 효율적인 유지관리 시스템의 개발로 투자 비를 적정화하고자 하는 노력이 크게 증가되고 있다. 도로 포장 구조체가 도 로 이용자에게 어느 정도의 안전성, 쾌적성 및 신속성을 제공하고 있는가를 평가하는 것은 포장관리의 중요한 고려사항이며 그 결과는 포장의 공용성 개념으로 표현된다. 포장상태 조사시 포함되는 항목들은 포장유지관리 시스 템을 운용하는 기관마다 약간씩 차이는 있으나 대체로 노면조도, 노면장애, 구조적 능력, 미끄럼저항등이다. 이중 진동계측장비가 많이 사용되는 항목은 노면조도와 구조적 능력평가 부분으로서 이 두 항목에 포함되는 진동 계측 장비와 그 이용방법에 관해서 논하고자 한다.

  • PDF

A Study on Assessment of Vibration Serviceability of Highway Bridges Using Driving Simulator (주행 시뮬레이터를 활용한 운전자 중심의 교량 진동 사용성 평가기준 연구)

  • Oh, Jeong-Jae;Park, Jong-Sub;Sung, Ik-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1778-1784
    • /
    • 2010
  • This study investigates the criteria for assessing the vibration serviceability of highway bridges using advanced driving simulator. Reiher-Meister Curves were firstly reviewed for extended application to serviceability of highway bridges. Modified Reiher-Meister Curves were provided in this paper based on field test results and numerical analyses results. The Modified Reiher-Meister Curves were evaluated using advanced driving simulator. The new curve consisted of 4 level, A(Disturbing), B(Strongly perceptible), C(Allowable), and D(Comfortable). The new criteria will be extensively applied to design and maintain highway bridges with respect to driver condition.

A Study on the Noise and Vibration Reduction at Sport Center on a Tall Building Apartment (초고층 빌딩 스포츠 센타의 충격성 진동으로 기인하는 소음진동 영향성 평가 및 저감대책)

  • 박해동;김강부;강현승;이홍기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.196-201
    • /
    • 2003
  • 철골조 초고층아파트 내부의 스포츠 시설 운영시 이를 사용하는 시설의 종류와 운동양상에 따라 아파트 상하부층에 소음진동의 민원문제를 유발하게 된다. 초고층 아파트 내부에 스포츠 시설의 배치는 이를 이용하는 사용자에게 편리성의 주지만 철골조의 특성상 충격성 진동원이 발생하는 스포츠 시설은 상하부층인 아파트에 소음진동의 연향으로 인해 이를 방지하는 설계가 요구된다. 일반적인 아파트의 충간 소음진동문제는 이를 발생시키는 상부거주자의 예절과 충간 소음진동 저감기술이지만 아파트 내부의 동일층을 경계로 위치한 스포츠 시설은 시설의 사용성에 반해 하부층에 미치는 영향을 기술적으로 저감하여야 한다. 입주한 초고층아파트에 발생하는 소음진동문제를 풀기 위하여 스포츠 시설 하부층 아파트의 소음진동 기준을 선정하고 스포츠 시설의 주된 진동원인 런닝머신의 하중식을 산정하고 충간 소음진동 저감을 위한 대책을 제시하였다.

  • PDF

Vibration Characteristics and the Serviceability Evaluation of High-rise Building during Strong Wind (강풍시 고층건물의 진동특성 및 사용성 평가)

  • Yoon, Sung-Won;Kim, Do-Hyun;Jeong, Sug-Chang;Kim, Dong-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.5
    • /
    • pp.57-65
    • /
    • 2007
  • After measuring wind induced response for a high-rise steel building, the damping ratio and natural frequency were analyzed in this paper. In order to examine amplitude dependence, random decrement method was used. Two methods were analyzed by comparing dynamic properties from random decrement method and half powered-band width method. In addition, through serviceability evaluation during strong wind, compatibility of two methods to Japanese guidelines for the evaluation of habitability to building vibration and national building code of Canada was considered. The amplitude dependence of the damping ratio by RD method was shown and the amplitude dependence of the natural frequency was relatively very small in an aspect of engineering sense. Moreover, the measured building was satisfied with serviceability and Japanese guideline is stricter than NBCC code.

  • PDF

상시 진동을 이용한 부유식 구조물의 동적 특성 추출

  • Kim, Han-Sam;Park, Su-Yong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.253-255
    • /
    • 2013
  • 수요가 늘어가고 있는 부유식 해양플랜트 구조물의 열악한 해양환경에서의 구조물의 노후화, 사고발생 가능성에 대비해 지속적인 평가가 필요하나, 기존의 구조물에 사용되는 안전성 평가 기법으로는 한계가 있어, 상시적인 구조물의 건전성 평가기법이 필요하다. 그래서 본 연구에서는 상시적인 구조물의 건전성 평가기법을 위해 부유식 구조물의 상시적인 응답 가속도를 추출하여 해당 구조물의 동적특성을 추출 하였다.

  • PDF

Serviceability Performance Evaluation of Vertical Vibration of Waflle Shape and Duble-Tee Precast Concrete Slabs (와플형과 더블티형 프리캐스트 콘크리트 바닥판의 수직진동 사용성 평가)

  • Shin, Jae-Sang;Chung, Lan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.62-69
    • /
    • 2010
  • In this study, the serviceability performance of Waffle Shaped(WAS) and Double-Tee(DT) precast concrete slabs were evaluated and compared based on the vertical acceleration magnitude induced by walking and heel drop loads. Tests were conducted for practical building structures of which floor systems used WAS and DT slabs. Natural frequencies of the slabs were similar to those obtained by using analytical models. The measured acceleration level was evaluated by vertical floor acceleration criteria presented by ISO-2631, AIJ(1991, Japan) and a previous study regarding floor vibration limit. Test results showed that both WAS and DT slabs satisfied all the criteria and Peak acceleration level of WA slabs was lower than that of DT slabs.

Vibration Serviceability Evaluation of a Single Span Steel-Concrete Composite Foot Bridge under Dynamic Pedestrian Loadings Considering Moving Mass Effect (이동 질량 효과를 고려한 단경간 강합성 보행교의 보행 하중 진동 사용성 평가)

  • Wonsuk Park
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.2
    • /
    • pp.75-83
    • /
    • 2023
  • In this paper, we present the analysis results on the vibration serviceability of a pedestrian bridge considering the effect of pedestrian moving mass inertia. Using dynamic finite element analysis, we considered different walking scenarios, including pedestrian density, walking speed, random walking, and synchronized walking, to analyze the acceleration response of a 40m long single-span bridge with a steel composite box cross section. We showed that the equivalent fixed mass analysis method did not significantly differ from the moving mass analysis in the random walk scenario and a wider frequency excitation band may be useful to consider when evaluating vibration serviceability in a random walk scenario.

Evaluation of Vibration and Structural Performance of an Innovative Sliding Step Steel Stair Using Full-Scale Mock-up Test (실물대 목업실험에 의한 슬라이딩스텝 철골계단의 진동 및 구조성능 평가)

  • Kim, Sung Yong;Lee, Cheol Ho;Kim, Na Eun;Cho, Sung Sang;Chung, Woon Ok
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.511-522
    • /
    • 2014
  • In this study, an innovative steel stair system is presented which enables rapid erection and high quality control in both residential and office building construction. This system features two lightweight steel stringers of box shape, bolted connections easy to absorb construction tolerance, and stair steps movable transversely (or sliding steps) such that the work space needed for concrete stairway wall could be easily provided. In this type of stairway system, other than providing robust connecting details, ensuring vibration performance is especially important since this system may be vibration-sensitive due to lightweight nature and/or probable low damping. To tackle these issues, a series of full-scale mock-up tests were conducted by using box-shape stringer members with or without concrete-fill. The connection system was shown to be sufficiently stiff and strong, or it remained elastic even under the 160% of service load level. Among the seven stringer alternatives, five exhibited satisfactory vibration performance according to the related North American and European acceptance criteria.

A new type liquid damper with adjustable natural frequencies (고유진동수 조절이 가능한 새로운 형태의 액체댐퍼)

  • Lee, Hye-Ri;Min, Kyung-Won;Park, Ji-Hun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.161-165
    • /
    • 2011
  • 본 논문에서는 고유진동수 조절이 가능한 새로운 형태의 액체댐퍼를 개발하였다. 동조댐퍼는 구조물의 설계단계에서 응답평가를 통해 필요성이 요구된다. 건물은 설계단계에서 고유진동수와 시공 후 고유진동수가 상이하다. 액체댐퍼의 형태는 설계단계에서 건물의 고유진동수를 동조시킬 수 있도록 설계되기 때문에 고유진동수가 고정이 될 수 있다. 본 연구에서는 제안한 댐퍼의 전체적인 형태는 기존의 Liquid Column Vibration Absorber(LCVA)와 같다. 기존의 LCVA는 시공 후 건물의 고유진동수에 동조시키기 위해 물높이를 조절하나 층고 때문에 제한이 있다. 우리가 제안한 새로운 형태의 액체댐퍼는 물높이 조절 뿐 아니라 수직관의 면적을 조절하여 고유진동수를 조절 할 수 있도록 개발하였다. LCVA의 수직관을 일정한 면적의 독립된 셀로 나누었으며 이 셀을 각각 밀폐시킬 수 있도록 하였다. 밀폐된 셀 안으로는 공기압력에 의해 물이 차지 않고 차 있는 물도 움직이지 않게 된다. 밀폐된 셀의 개수를 조정하여 수직관의 면적이 조절하여 고유진동수를 변화시킬 수 있다. 제작된 액체댐퍼의 밀폐된 셀 개수를 조절하여 진동대 실험을 통해 댐퍼의 고유진동수를 파악하였다. 실험으로 나온 고유진동수와 이론적으로 산정한 고유진동수를 비교하여 댐퍼의 사용성을 평가하였다. 개발된 액체 댐퍼의 수직관의 면적 조절을 통해 고유진동수 조절이 용이하여 실제로 사용이 가능함을 확인할 수 있었다.

  • PDF