• Title/Summary/Keyword: 진동감시시스템

Search Result 102, Processing Time 0.027 seconds

The Structural Design and Analysis of Spring Stabilizer for Aircraft Surveillance and Reconnaissance EO/IR Equipment (감시정찰 전자광학장비용 스프링 안정화 장치 구조 설계 및 해석 연구)

  • Yoonju Jung;Suhyeon Kim;Sanghyun Nam;Injae Park;Mingyun Park;Taekyun Kim;Hwanseok Yang;Seungwook Park;Seungha Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.5
    • /
    • pp.28-33
    • /
    • 2023
  • In this research, the isolator and the inner gimbal inside of typical EO/IR equipment were replaced with a spring stabilizer. This Spring stabilizer system revealed an internal platform capable of external vibration damping and 6-DOF driving. This system was designed based on machined springs and spring modules of the spring stabilizer, structure, and other fixture. Through modal vibration analysis, suitable material for the spring was determined. Structural stability of the spring stabilization device was determined through random vibration analysis.

Wireless Measurement System for Machine Condition Monitoring (기계 상태 감시를 위한 무선 측정 시스템)

  • Shim, Min-Chan;Yang, Bo-Suk;Lee, Jea-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.883-886
    • /
    • 2005
  • This paper proposed a wireless measurement system (WMS) for an effective condition monitoring using wireless communication. WMS consists of two parts: transmitter(TM) acquired a dynamic signal from physical system using ICP type accelerometer sensor. An acquired signal modulated through the low/high pass filter and amplifier in DAQ board, which converted to digital signal. Embedded board(E-board) transferred digital signals to base station(BS) through the socket IEEE.802.11.b. BS is adopted IOCP server structure. Because it can acquired signal well during transferred digital signal. Signal processing used LabVIEW Library, BS(server) designed to realize multi-thread using visual C++.NET for 1 many meaning data processing

  • PDF

Development of knowledge based expert system for fault diag industrial rotating machinery (산업용 회전 기기의 현장 이상 진단을 위한 지식 기반 전문가 시스템 개발)

  • 이태욱;이용복;김승종;김창호;임윤철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.633-639
    • /
    • 2001
  • This paper proposes a knowledge-based expert system. which is assembled into hardware organized with sensor module. AID converter, USB. data acquisition PC and software composed of monitoring and diagnosis module combined with a frame-based method using Sohre's chart and a rule-based method. Vibration signals using various sensors are acquired by AID converter. transferred into PC and processed to obtain a continuous monitoring of the machine status displayed into several plots. Through combining frame-base which covers wide vibration causes with rule-base which gives relatively specified diagnosis results, high accuracy of fault diagnosis can be guaranteed and knowledge base can be easily extended by adding new causes or symptoms. Some examples using experimental data show the good feasibility of the proposed algorithm for condition monitoring and diagnosis of industrial rotating machinery.

  • PDF

Real-time Multi-sensing System for In-process monitoring of Chatter Vibration(l) (채터진동의 인프로세스 감시를 위한 실시간 복합계측 시스템(1))

  • Kim, Jeong-Suk;Kang, Myeong-Chang;Park, Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.10
    • /
    • pp.50-56
    • /
    • 1995
  • Chatter Vibration is an unwanted phenomenon in metal cutting and it always affects surface finish, tool life, machine life and the productivity of machining process. The real-time detection of the chatter vibration is is necessarily required to automation system. In this study, we constructed the multi-sensing system using Tool Dynamometer, Accelermeter and AE sensor. Especially, Acoustic Emission(AE) generated during turning was investigated the possibility for real-time detection of chatter vibration. Turning experiments were performed using carbide insert tip under realistic cutting conditions and tapered workpiece of SM45C. Consquently, the real-time detection using multi-sensing system can be used for Inprocess monitoring of chatter vibration.

  • PDF

Development of the Multichannel Vibration Monitoring System (다채널 진동 모니터링 장치 개발)

  • Hong, Tae-Yong;Park, Soo-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.7
    • /
    • pp.671-676
    • /
    • 2016
  • This study is about design for the Rotational Instrument of the Industry factory which is used management safety and maintenance. We developed the multichannel vibration monitering system of the self-diagnosis for middle level CMS(Condition Monitoring System) market, and that system are new features to the expandability and flexibility. Normally one channel is used for treating one signal, but developed instrument can treat four channel with one signal processing card. One rack have redundant power supply and displace and it can check vibration measurement value in field without computer. Bearing fault detection is fundamental of vibration surveillance, but sometimes can not check with vibration velocity and acceleration. So it need the filtering and the amplitude modulation on the acceleration enveloping technology when irregular vibration is happened. We developed the vibration analysis instrument which is applied such technology. And the development prototype shows activated within the vibration error limit.

Development of a Portable Vibration Analyzer for Precision Diagnosis of Plant's Rotating Equipment (발전소 회전기기 정밀진단을 위한 휴대용 진동분석기 개발)

  • Noh, Hyungho;Y, Hoseon
    • Plant Journal
    • /
    • v.17 no.4
    • /
    • pp.53-60
    • /
    • 2021
  • The purpose of this study was to develop a portable vibration analyzer that is effective for acquiring and analyzing vibration data of rotating equipment of a power plant and a domestic vibration monitoring system manufacturer Nada Co., Ltd. The hardware of the developed portable vibration analyzer minimizes measurement errors by calibrating the measured values obtained through measurement uncertainty for calibration of the measuring devices in the system, and is composed of a signal processing device with high resolution through high speed data processing. The software structure implements a variety of vibration plots to execute a detailed analysis program, and applies algorithms to measure and remove noise caused by disturbances while operating a rotating machine. The developed product contributed greatly to increase the user's mobility and performance, as well as to reduce the purchase cost due to localization.

The Study on the Correlation of Vibration, Wear and Temperature for Rubbing in Rotating Machinery (마멸현상에서 발생하는 회전기 시스템의 진동.마모.온도의 상관 관계 연구)

  • 백두진;김승종;윤의성;김창호;공호성;장건희;이용복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.453-459
    • /
    • 2002
  • In this paper. the correlation among vibration. wear and temperature are experimentally investigated when rubbing is caused by static and dynamic forces. Each measurement reflects the characteristics of the system and is useful in detecting and diagnosing the current status of rotating machinery. For experiment, the rotor system with lubricating equipment such as trochoid pump, oil tank and wear detecting sensor is implemented to simulate the rubbing condition. Experimental results show that significant change in wear quantity can be notified when vibration signal is changed by rubbing. The results can be applied to system monitoring and fault diagnosis in rotating machinery.

  • PDF

A Study on Development of Displacement Measurement System for Structure using a Laser and 2-D Arrayed Photo Sensors (레이저와 2차원 배열의 광전검출기를 이용한 구조물의 변위측정 시스템의 개발에 관한 연구)

  • Kang, Moon-Phil;Lee, Jin-Yi;Kim, Min-Soo;Kim, Dae-Jung;Choe, Won-Ha;Kang, Ki-Hun;Kim, Jong-Soo;Kim, Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.22-31
    • /
    • 2002
  • A Safety Monitoring System using a laser and 2-D arrayed photo sensors is developed. To monitor of the deformation and small rotation of structure the developed optical system using 2-D photo sensor array was used to detect the variation of optical orbit of laser which was induced by deformation of the structure. Also, an operating program to manage the system and an algorithm for the data acquisition and the database are introduced. In this study, we demonstrated the capabilities of this system by laboratory experiments before applying the system to the field.

Development of a Building Monitoring System based on Wireless Sensor Network (무선 센서 네트워크 기반의 빌딩 모니터링 시스템 개발)

  • Chang, Hyeong-Jun;Kim, Jae-Woo;Chang, Kyung-Bae;Shim, Il-Joo;Park, Gui-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2118-2119
    • /
    • 2006
  • 최근 이슈가 되고 있는 무선 센서 네트워크를 기반으로 빌딩 주변의 환경 정보를 감시하고, 실시간 관리가 가능한 시스템을 개발하였다. 센서에 의한 환경 정보는 빌딩의 안전감시와 진단 그리고 효율적 에너지관리를 위한 분석용 데이터로 사용된다. 이러한 환경 정보에는 온도, 습도, 진동, CO2 등과 같은 센서가 있으며, 이러한 센서들로부터 오는 환경 정보를 저전력, 저비용, 자가 구성이 가능한 무선 센서 네트워크기술을 이용함으로써 단기적으로는 빌딩의 안전진단이나 온, 습도와 같은 환경정보를 얻을 수 있으며, 장기적으로는 유지 보수의 비용문제를 효율적으로 줄일 수 있고, 실시간 정보 수집과 자가 구성에 의한 에너지 절감이 가능하다. 본 논문에서는 무선 센서 네트워크를 이용한 빌딩 모니터링 시스템을 정의하고, 시스템을 설계한 후 실험을 통하여 향후 무선 센서 네트워크의 빌딩 및 건축물로의 적용 가능성을 검증하였다.

  • PDF

Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves (발전용 밸브누설 음향 진단 및 감시시스템)

  • Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF