• Title/Summary/Keyword: 진동/충격하중

Search Result 146, Processing Time 0.028 seconds

Responses of structure to impulsive loading with application of viscoplasticity (점소성론을 이용한 구조물의 충격응답 해석)

  • 김상환
    • Computational Structural Engineering
    • /
    • v.8 no.3
    • /
    • pp.59-66
    • /
    • 1995
  • The dynamic responses of structure under impulsive loading have been investigated according to its duration, based on the theory of viscoplasticity which can appropriately represent the effects of plasticity and rheology simultaneously. The viscoplastic model has been implemented into the two-dimensional finite element system to solve plane stress, plane strain or axi-symmetric problems, and the implicit integration scheme, of which solutions are unconditionally stable for relatively large time step length, has been developed to simulate visoplastic straining with deriving the explicit relationship between stress and strain at a material point level. After simulation, one carefully concludes that the duration as well as magnitude of impulsive loading plays an important role in design of structures.

  • PDF

KSC-7 사용후핵연료 수송용기의 트레일러 운반에 대한 진동평가

  • 서기석;구정회;정성환;도재범;노성기
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05c
    • /
    • pp.458-463
    • /
    • 1996
  • 수송용기가 운반 트레일러에 의해 정상수송될 때, 국내 도로 상태에서 발생되는 반복적인 진동 흑은 충격하중을 측정하기 위해 국도 및 고속도로에서 차량수송시 가속도량를 기록하였으며, 이 측정결과를 주파수분석기로 분석하여 전산진동해석을 위한 입력자료를 생산하였다. 수송용기의 기계구조에 대한 건전성을 평가하기 위한 전산해석은 ABAQUS 코드로 KSC-7 수송용기를 3차원 보요소로 모델링하여 응력평가를 수행하였다.

  • PDF

A Study on the Vibration Characteristics by the Change of Impact Load Direction in the Collecting Plates of Electrostatic Precipitator (충결하중의 방향에 따른 정전집진기 집진판의 진동 특성 연구)

  • 나종문;이기백;양장식
    • Journal of KSNVE
    • /
    • v.5 no.2
    • /
    • pp.247-256
    • /
    • 1995
  • In this paper, double exposure holographic interferometry using ruby pulse laser is formed in order to investigate the propagation of transient waves. The vibration characteristics according to the change of impact load direction, i.e., impacted in the shear direction and in the normal direction are analyzed. It was observed that the macroscopic trends of transient wave generation and propagation in the assembly of precipitator plates were almost similar regardless of the change of impact load direction. But the propagation and mixing of transient wave was advanced relatively slowly when impacted in the normal direction.

  • PDF

Impact sound analysis on damaged composite laminate (손상이 있는 복합 적층판의 충격음 해석)

  • Kim, Sung-Joon;Jang, Moon-Ho;Sin, Jeong-U;Ahn, Seok-Min;Yeom, Chan-Hong;Hong, Chang-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.465-475
    • /
    • 2010
  • 구조물의 손상을 평가하기 위한 적용되는 태핑 테스트를 효과적이고, 정확하게 사용하기 위하여 적층판의 충격 시 발생하는 현상을 수치적인 방법을 이용하여 해석하였다. 구조물의 진동에 의해 방사되는 음은 구조물의 거동과 직접적으로 연관되므로 충격응답해석이 수행되어야 한다. 본 논문에서는 층간분리가 존재하는 적층판의 해석을 위하여 층간분리 모델을 사용하였으며, 해머 형상의 충격체를 모사할 수 있는 효과적인 스프링-질량모델을 제시하였다. 또한 태핑 테스트 시 방사되는 음압을 Rayleigh 적분식을 이용하여 해석하였다. 예측된 음압이력과 시험결과와 비교하였으며, 음압이력과 충격하중이력에 손상이 주는 영향을 검토하였다. 방사되는 음압과 충격하중이력은 적층판에 존재하는 손상에 영향을 받는 것을 보였다. 결과적으로 제안된 음을 이용한 태핑실험은 복합재에 존재하는 손상을 검출하는데 신뢰성 있는 방법임을 알 수 있었다.

  • PDF

A Study on the Noise and Vibration Reduction at Sport Center on a Tall Building Apartment (초고층 빌딩 스포츠 센타의 충격성 진동으로 기인하는 소음진동 영향성 평가 및 저감대책)

  • 박해동;김강부;강현승;이홍기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.196-201
    • /
    • 2003
  • 철골조 초고층아파트 내부의 스포츠 시설 운영시 이를 사용하는 시설의 종류와 운동양상에 따라 아파트 상하부층에 소음진동의 민원문제를 유발하게 된다. 초고층 아파트 내부에 스포츠 시설의 배치는 이를 이용하는 사용자에게 편리성의 주지만 철골조의 특성상 충격성 진동원이 발생하는 스포츠 시설은 상하부층인 아파트에 소음진동의 연향으로 인해 이를 방지하는 설계가 요구된다. 일반적인 아파트의 충간 소음진동문제는 이를 발생시키는 상부거주자의 예절과 충간 소음진동 저감기술이지만 아파트 내부의 동일층을 경계로 위치한 스포츠 시설은 시설의 사용성에 반해 하부층에 미치는 영향을 기술적으로 저감하여야 한다. 입주한 초고층아파트에 발생하는 소음진동문제를 풀기 위하여 스포츠 시설 하부층 아파트의 소음진동 기준을 선정하고 스포츠 시설의 주된 진동원인 런닝머신의 하중식을 산정하고 충간 소음진동 저감을 위한 대책을 제시하였다.

  • PDF

A Study on the Sloshing of Cargo Tanks Including Hydroelastic Effects (유탄성을 고려한 탱크내 슬로싱에 대한 연구)

  • Dong-Yeon Lee;Hang-Shoon Choi
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.35 no.4
    • /
    • pp.27-37
    • /
    • 1998
  • The sloshing is very important in a safe transport of the liquid cargo by a ship. With the increasing number of supertanker and LNG carriers, this problem has become increasingly more important. In order to study the magnitude and characteristics of impact pressures due to sloshing, experiments ware performed with a rectangular tank and compared with numerical results. Structural responses of tank wall under impulsive pressures were measured. Structural vibrations induced by the sloshing load were analysed by including hydroelastic erects in terms of added mass and damping. To check the validity of the numerical model, the natural frequencies of plate in air and water were compared with measurements, and a good agreement was found. In the case that a plate vibrates under impulsive loads, the pressure on the flexible plate is larger than that on the rigid plate without hydroelastic effects, which was confirmed experimentally. The frequency of oscillatory pressure as well as accel%pion coincides with the natural frequency of plate in water.

  • PDF

Development of Impact Factor Response Spectrum with Tri-Axle Moving Loads and Investigation of Response Factor of Middle-Small Size-RC Slab Aged Bridges (3축 이동하중을 고려한 충격계수 응답스펙트럼 개발 및 중소규모 RC 슬래브 노후교량 응답계수 분석)

  • Kim, Taehyeon;Hong, Sanghyun;Park, Kyung-Hoon;Roh, Hwasung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.67-74
    • /
    • 2019
  • In this paper the response factor is investigated for middle and small size-RC slab aged bridges. The response factor consists of static and dynamic response factors and is a main parameter in the frequency based-bridge load carrying capacity prediction model. Static and dynamic response factors are determined based on the frequency variation and the impact factor variation respectively between current and previous (or design) states of bridges. Here, the impact factor variation is figured out using the impact factor response spectrum which provides the impact factor according to the natural frequency of bridges. In this study, four actual RC slab bridges aged over 30 years after construction are considered and their span length is 12m. The dynamic loading test in field using a dump truck and eigenvalue analysis with FE models are conducted to identify the current and previous (or design) state-natural frequencies of the bridges, respectively. For more realistic considerations in the moving loading situation, the impact factor response spectrum is developed based on tri-axle moving loads representing the dump truck load distribution and various supporting conditions such as simply supported and both ends fixed conditions. From the results, the response factor is widely ranged from 0.21to 0.91, showing that the static response factor contributes significantly on the results while the dynamic response factor has a small effect on the result. Compared to the results obtained from the impact factor response spectrum based on the single axle-simply supported condition, the maximum percentage difference of the response factors is below 3.2% only.

A Study on Damage Assessment Technique of Railway Bridge Substructure through Dynamic Response Analysis (동적 응답 분석을 통한 철도교량 하부구조의 피해평가기법연구)

  • Lee, Myungjae;Lee, Il-Wha;Yoo, Mintaek
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.11
    • /
    • pp.61-69
    • /
    • 2021
  • In this study, scale down model bridge piers were fabricated and non-destructive experiments conducted with an impact load to determine scours in the ground adjacent to the bridge piers using the natural frequency of the bridge piers. Three scale-model bridge piers with different heights were fabricated, and they penetrated the ground at a depth of 0.35 m. The scours around the bridge piers were simulated as a side scour and foundation scour. The experiments were conducted in 13 steps, in which scouring around the model bridge piers was performed in 0.05 m excavation units. To derive the natural frequency, the impact load was measured with three accelerometers attached to the model bridge piers. The impact load was applied with an impact hammer, and the top of the model bridge pier was struck perpendicularly to the bridge axis. The natural frequency according to the scour progress was calculated with a fast Fourier transform. The results demonstrated that the natural frequency of each bridge pier tended to decrease with scour progress. The natural frequency also decreased with increasing pier height. With scour progress, a side scour occurred at 70% or higher of the initial natural frequency, and a foundation scour occurred at less than 70%.

Vibration Reduction Effect and Structural Behavior Analysis for Column Member Reinforced with Vibration Non-transmissible Material (진동절연재로 보강된 기둥부재의 진동저감효과 및 구조적 거동분석)

  • Kim, Jin-Ho;Yi, Na-Hyun;Hur, Jin-Ho;Kim, Hee-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.94-103
    • /
    • 2016
  • For elevated railway station on which track is connected with superstructure of station, structural vibration level and structure-borne-noise level has exceeded the reference level due to structural characteristics which transmits vibration directly. Therefore, existing elevated railway station is in need of economical and effective vibration reduction method which enable train service without interruption. In this study, structural vibration non-transmissible system which is applied to vibroisolating material for column member is developed to reduce vibration. That system is cut covering material of the column section using water-jet method and is installed with vibroisolating material on cut section. To verify vibration reduction effect and structural performance for structural vibration non-transmissible system, impact hammer test and cyclic lateral load test are performed for 1/4 scale test specimens. It is observed that natural period which means vibration response characteristics is shifted, and damping ratio is increased about 15~30% which means that system is effective to reduce structural vibration through vibration test. Also load-displacement relation and stiffness change rate of the columns are examined, and it is shown that ductility and energy dissipation capacity is increased. From test results, it is found that vibration non-transmissible system which is applied to column member enable to maintains structural function.