• Title/Summary/Keyword: 진단X선

Search Result 241, Processing Time 0.027 seconds

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

Development of a Medical Radiation Simulator System for Education and Proposal of a Research Model (교육용 의료방사선 시뮬레이터 시스템 개발 및 연구 모델 제안)

  • Chang-Hwa Han;Young-Hwang Jeon;Jae-Bok Han;Chang-gi Kong;Jong-Nam Song
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.459-464
    • /
    • 2023
  • Due to the development of advanced technology, a lot of digital radiographic equipment has been developed, which is very helpful for accurate diagnosis and treatment, and it is very important to train personnel who have acquired professional knowledge in order to use it safely and effectively. Students are exposed to the risk of radiation exposure in radiography training using diagnostic X-ray equipment, and some educational institutions do not use X-ray equipment due to management difficulties in accordance with the Nuclear Safety Act. As a solution to this, this study developed a medical radiation simulator for education that does not generate radiation by using a vision sensor and self-developed software. Through this, educational institutions can reduce the burden of administrative implementation according to the law, and students can obtain a high level of educational effects in a healthy practice environment without radiation exposure.

Development of High Voltage Generator for Diagnostic X-ray Equipment (진단용 X선 기기의 고전압 발생장치 개발)

  • Kim, Young-Pyo;Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.764-765
    • /
    • 2010
  • The medical treatment X-ray machineries used in diagnosis of the human body is possible to diagnosis inside of the human body with the method of noninvasive so that it has shared a very important role in diagnosis from the medical institution. High voltage occurrence system which is most important in occurrence of X-ray has mainly been used the existing type of high voltage transformer, however it has a low efficiency of X-ray occurrence since it is a big and heavy, and a high ripple ratio of the direct current high voltage come to the X-ray tube. In order to solve this problem, the research has been advanced about the high voltage power supply system, and the inverter type of the high voltage occurrence system which occurs a high voltage by increasing the power frequency from about ten times to about hundred times with the inverter has currently used mainly. Also, the operation of tube voltage and tube current was controlled by using PWM method and the operation results were identified using an oscilloscope.

  • PDF

X-ray Absorptiometry Image Enhancement using Sparse Representation (Sparse 표현을 이용한 X선 흡수 영상 개선)

  • Kim, Hyungil;Eom, Wonyong;Ro, Yong Man
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.10
    • /
    • pp.1205-1211
    • /
    • 2012
  • Recently, the evaluating method of the bone mineral density (BMD) in X-ray absorptiometry image has been studied for the early diagnosis of osteoporosis which is known as a metabolic disease. The BMD, in general, is evaluated by calculating pixel intensity in the bone segmented regions. Accurate bone region extraction is extremely crucial for the BMD evaluation. So, a X-Ray image enhancement is needed to get precise bone segmentation. In this paper, we propose an image enhancement method of X-ray image having multiple noise based sparse representation. To evaluate the performance of proposed method, we employ the contrast to noise ratio (CNR) metric and cut-view graphs visualizing image enhancement performance. Experimental results show that the proposed method outperforms the BayesShrink noise reduction methods and the previous noise reduction method in sparse representation with general noise model.

Cross Calibration of Dual Energy X-ray Absorptiometry Equipment for Diagnosis of Osteoporosis: between Domestic Manufacturers and Global Manufacturers (골밀도 장치의 교차분석 ; 국내 제조사와 해외 제조사 비교)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.833-844
    • /
    • 2018
  • Dual energy X-ray absorptiometry is mainly used as an X-ray test method. For equipment manufactured GE and Hologic, cross-calibration analyses (CCA) of machines from the same manufacturer and between units from different manufacturers have been conducted, but the CCA of equipment manufactured in Korea are inadequate. Through CCA, we present a formula of the intersections between the Korean medical equipment company (KEC) with GE and Hologic manufactured DXA, and among the KEC DXA. The CCA was conducted for the European Spine Phantom on DXA from four KEC and three global medical equipment company (GEC) manufacturers. We compared bone mineral density (BMD) values and calculated the CCA equation by linear regression analysis. The standard-deviations (SD) of the BMD values were highest for the Dexxum T for the low, medium, and high spine, which were 0.030, 0.029, and 0.037, respectively. The smallest SD in the low and medium vertebrae were 0.005 and 0.004 for the Horizon Ci, respectively, and 0.005 for the Osteo Pro Max in the high vertebrae. Based on the intersection equations of the KEC DXA established in this study, CCA of various KEC DXA should be established for more accurate follow-up of BMD tests in clinical environments.

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.

Comparison of Weight Functions in Iterative Technique for Image Reconstruction of Gamma-ray CT (감마 CT 영상재구성을 위한 반복적인 방법의 가중치 함수비교)

  • Lee, Na-Young;Jung, Sung-Hee;Kim, Jong-Bum;Kim, Jin-Sup;Kim, Jae-Ho
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.10c
    • /
    • pp.480-484
    • /
    • 2007
  • 일반적으로 x선 CT는 물체 투과율이 짧기 때문에 대형 산업공정 내부의 영상진단 시 대상체는 금속으로 구성되어 있으며 내부는 액체, 고체, 기체 등 고밀도 물질이 포함되어 있어 계측이 어렵다. 따라서 본 논문에서는 물체 투과율이 x선에 비해 긴 감마선을 사용하였다. 대형 산업공정 내부의 단면영상을 재구성하기 위하여 반복적인 영상재구성 방법의 가중치 함수를 비교하였다. 실험 결과를 통하여 감마 CT 영상에서 빔 통과 여부에 따른 가중치 함수보다 빔 길이나 면적에 의한 가중치 함수로 복원할 경우, 원 영상과 유사함을 확인하였다.

  • PDF

State-of-the-art digital mammography systems (첨단 디지탈 유방조영 시스템의 개발현황과 미래)

  • Choi, Won-Young
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.142-145
    • /
    • 1995
  • 스크린-필름 X선 유방조영술(Screen-film X-ray mammography)은 유방암 진단을 위한 기준이 되는 방법으로 독보적인 위치를 차지하고 있다. 그러나 현재 사용되는 스크린-필름 방식 유방조영술은 여러 가지 한계점들이 인식되어 왔으며, 만약 유방 X선 사진(mammogram)이 디지탈 형식으로 곧 바로 얻어진다면 영상의 질(image quality)과 방사선량의 감소 가능성 관점에서 향상될 수 있다는 증거가 있다. 본 논문에서는, 디지탈 유방조영술에 대한 논리적 근거가 제시되고, 스크린 대용으로 개발되고 있는 X-선 검출기들과 이들을 사용한 여러가지 디지탈 유방조영술 시스템들을 분석 전망한다. 디지털 유방조영술을 실용화하기 위해 해결되어야 할 문제점들이 논의된다.

  • PDF

The Study of Diagnostic Results Discordance Analysis on BMD Using DEXA (이중에너지 X선 흡수 계측법을 이용한 골밀도 검사 시 진단불일치에 대한 분석)

  • Park, Won-Kyu;Kang, Yeong-Han;Jo, Gwang-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.25-31
    • /
    • 2008
  • Purpose : This study was conducted to understand for the diagnostic discordance of bone mineral density(BMD) in DEXA(Dual Energy X-ray Absorptiometry). And the diagnostic difference between lumbar spine and femur neck, forearm was evaluated using T-score. Materials and Methods : We studied 220 females measured BMD on lumbar spine, and femur neck, forearm including ward's triangle and ultra digital(UD). We were distinguished T-score into normal, osteopenia, osteoporosis(WHO classification) and evaluated discordance rate according to age and degree of bone loss. Correlation analysis and chi-square test between L-spine, L-4, femur neck, Ward, Forearm, UD were carried out. Results : In the lumbar spine, the number of normal were in 57(25.9%), osteopenia in 86(39.1%), osteoporosis in 77(35.0%). In the L-4 and ward's triangle, the number of osteoporosis were in 78(35.5%), in 126(57.3%). There was significant correlation between lumbar, femur neck and forearm BMD in all cases. The discordance of BMD between lumbar and femur were 57%, lumbar and forearm 43%, forearm and femur 51%. The discordance rates of normal, osteopenic, osteoporotic groups were 39%, 64%, 43%, respectively, showing the highest discordance rate in osteopenia patients. In normal group of lumbar spine, the discordance rate was 25%, 23%, 11%, 65%, 86% in 30', 40', 50', 60', 70', respectively. In osteopenia, osteoporosis group of lumbar spine, the discordance rate was 62%, 55%, 36%, 20%, 9% in 30', 40', 50', 60', 70', respectively. Conclusion : It was different of the results of BMD with lumbar, femur and forearm site. The discordance rate was decreased with age in osteopenia, osteoporosis lumbar spine. In osteopenia group, the discordance rate was the highest. So, it is necessary that the BMD of lumbar, femur neck and forearm should be checked.

  • PDF