A New Loose Parts Monitoring Technique for Nuclear Steam Supply System based on High Resolution Sensor Array Signal Processing (고해상도 센서어레이 신호처리법을 이용한 원자력발전소 핵증기 공급계통의 새로운 금속파편 진단기법)

  • Rhee, Ill-Keun;Choi, Jae-Won
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.6
    • /
    • pp.76-84
    • /
    • 1997
  • Loose parts monitoring system(LPMS), which is used to detect metallic loose parts in the nuclear power plant, plays an important role in safe and reliable operation of the plant. To prevent from the damage due to the loose parts, most domestic nuclear power plants are using, or planning to use LPMS. However, these LPMS's, which are all invented from overseas and thereby depend on the oversea technologies, are very expensive, and are known to be inefficient to diagnose loose parts due to the lack of fundamental know-how of LPMS. Therefore, the main purpose of this paper is to propose and to realize a new loose parts localization algorithm which is simple and efficient enough even for the inexperienced operators to diagnose loose parts accurately and promptly. Considering practical nuclear power plant circumstances, some simulations for estimating the loose parts location have been done. The results show that the proposed method, called a modified circle intersection method, performs high resolved loose parts localization with 3.4% of error.

  • PDF

A Study on the Leakage Evaluation for Power Plant Valve Using Infrared Thermography Method (적외선열화상에 의한 발전용 밸브 누설명가 연구)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.110-115
    • /
    • 2010
  • This study was conducted to estimate the feasibility using thermal image measurement that is applicable to internal leak diagnosis for the power plant valve. Abnormal heating of valve surface associated with high temperature steam f10w toward valve outlet side in the condition of low temperature is a primary indicator of leakage problems in high temperature and pressure valves. Thermal imaging enables to see the invisible thermal radiation that may portend impending damage before their condition becomes critical. When steam flow in valve outlet side in the condition of low temperature is converted into heat transmitted through the valve body due to the internal leakage in valve. The existence of abnormally increasable leakage rate in the valve will result in abnormally high levels of heat to be generated that can be quickly identified with a thermal image avoiding energy loss or damage of valve component. From the experimental results, it was suggested that the thermal image measurement could be an effective way to precisely diagnose and evaluate internal leak situation of valve.

Clinical Findings and Therapy of Ureteral Duplication in 61 Children (소아에서의 중복요관에 관한 임상적 고찰)

  • Yook Jin Won;Kim Ji Hong;Kim Pyung Kil;Han Sang Won
    • Childhood Kidney Diseases
    • /
    • v.2 no.2
    • /
    • pp.169-177
    • /
    • 1998
  • Purpose : Renal duplication is a common occurrence, and the range of ureteral and renal anomalies draining the two poles of the duplex kidney leads to a variety of clinical presentations. Method : A series of 61 children with duplicated systems was studied retrospectively who were admitted during last 12years. Results : Of the children $60.6\%$ were accompanied with urologic anomalies that required surgical treatment, and most children initially were presented with urinary tract infection. $42.6\%$ of children were either diagnosed incidentally during evaluation of other non-urologic disease or during follow-up evaluation of abnormal antenatal renal sonogram. Conclusion : From our point view, children with history of abnormal antenatal renal sonogram, or with symptoms such as urinary tract infection, hematuria, abdominal pain should be evaluated radiologially fully to confirm further abnormality and accompanied complications. And routine follow-up using abdominal ultrasonogram, VCUG, and urine culture should be used to prevent and detect early treatable complications.

  • PDF

Ethernet Port를 이용한 차량 진단 모니터링 시스템의 설계

  • Shin, Ju-Young;Jang, Jong-wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.98-101
    • /
    • 2009
  • Recently, there is use of the vehicle network for vehicle diagnostic method and Increased use of the vehicle protocol such as (CAN(Controller Area Network), MOST, LIN, FlexRay), Distributed control and data about the vehicle are being sought methods for real-time observation and monitoring and trend tends to have gone into this. In this case of automotive diagnostic module in today, there is Primarily to use DLC(Data Link Connector)Connector called self-check terminal. Generally, vehicle Diagnoses to use DLC Connector such as OBD2(On Board Diagnostics) Through Diagnostic Module(scanner). But there limit diagnostic as engine and powertrain part, and not consider user's perspective In this paper, By designing Vehicle diagnostic monitoring system using Ethernet Port, transmit and Receives CAN protocol vehicle data, and implement Easily monitoring system that provide and Diagnoses to provide vehicle's state and information to use PC.

  • PDF

The Prevention Countermeasure against Breakdown of GIS using the Preventive Diagnostic Technology (예방진단기술을 활용한 GIS 고장예방대책)

  • Choi, Jong-Soo;Kim, Jong-Gu;Park, Jun-Sung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.423-427
    • /
    • 2009
  • In the circumstances which a highly reliable operation in electric power facilities of extra high voltage and large capacity is needed, the importance of a preventive diagnostic technology is growing large day and day. The settlement of a preventive diagnostic technology for optimization and efficient management on the electric power facilities like GIS enable the reduce of repair fee, the improvement of safety and the systematic management of electric power facilities. The remaining life prediction of facilities will play a decisive role as a core technology of a preventive diagnostics in the future. And so it is necessary a continuous research and concern for the development of a preventive diagnostic technology hereafter.

  • PDF

Efficiency Enhancement of Electricity Market by MOS-EMS Interfaced Operation (MOS-EMS 연계활용을 통한 전력시장의 효율개선)

  • Ok, Ki-Youl;Kim, Kwang-In;Kim, Doo-Jung;Kim, Kwang-Chul;Moon, Young-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.363-364
    • /
    • 2006
  • 변동비반영시장(CBP)의 장기화가 예상됨에 따라 전력거래소는 차기 도매전력시장의 운영을 위해 개발된 시장운영시스템(MOS)을 현행급전체계에 활용하는 사업을 추진하고 있다. 이를 위하여 전력거래소는 현 CBP의 비용기반 입찰자료를 MOS의 가격입찰 방식으로 등가적으로 변환하는 입찰변환시스템과 MOS-EMS 연계운영의 적정성을 감시 및 진단하는 시장운영감시시스템을 개발하였다. 또한 MOS의 실시간(5분) 급전계획이 최적으로 수립될 수 있도록 상태추정의 신뢰성 및 수요예측의 정확도를 향상시켰다. 아울러 MOS-EMS 연계운영의 안정성을 검증하기 위해 10단계에 걸친 실계통 실증시험을 성공적으로 종료하였으며, 그 결과 계통운영의 효율성 및 투명성 향상은 물론 연간 260억원 이상의 발전비용 절감효과가 발생함을 입증하였다.

  • PDF

Development of voltage-reactive power control algorithm in substation system (변전소 환경에서의 전압 무효전력 제어 알고리즘 개발)

  • Kang, Sang-Gyun;Jeon, Woong-Jae;Lee, Byong-Jun;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.238-239
    • /
    • 2006
  • 전력계통에 대한 감시, 해석, 진단 및 제어에서 방재, 보안기능에 이르기까지 변전소에서 행하여지는 모든 기능을 통합, 기능의 극대화, 공간의 최소화, 관리의 효율화 등을 도모하기 위하여 변전소자동화(Station Automation : SA)라는 개념이 대두되었다. 하지만 계통의 상태에 따라서 OLTC의 tap동작은 오히려 전압안정성을 저해하는 방향으로 동작할 수도 있다. 또한 변전소에 연결되어 있는 switched capacitor와 OLTC의 잘못된 co-ordination 동작은 쓸데없는 tap 동작을 야기 시킨다. 본 논문에서는 단일 변전소 환경하에서 전압 무효전력을 제어하는 알고리즘에 대해서 논의할 것이다.

  • PDF

Substation Grounding Performance Evaluation by Ground Current Measurement (지락전류 분류계수 측정에 의한 변전소 접지성능 진단)

  • Choi Jong kee;Ahn Yong Ho;Ryu Hee Young;Jung Gil Jo;Lee Bong Hee;Han Byung Sung;Kim Kyung Cheol
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.594-596
    • /
    • 2004
  • 부식이나 경년열화 등으로 인한 변전소 접지성능 저하에 대한 대책마련을 위하여 정기적인 변전소 접지저항의 측정은 필수적이라고 한 수 있다 그러나 단지 접지저항의 측정을 위하여 변전소 접지망과 연결되어 있는 외부접지계통, 즉 배전 중성선이나 송전선로 가공지선의 다중접지계통을 분리한다는 것은 현실적으로 불가능한 작업이다. 본 논문에서는 접지시험을 위한 시험전류를 주입하고 가공지선 및 중성선으로의 분류계수를 측정함으로써 운전 중인 상태에서 변전소 접지망 단독의 접지저항을 측정하는 시스템, 측정기법 및 사례연구를 제 시 하였다.

  • PDF

Analysis of a breakdown in 154 kV STATCON Bank condenser cell (154kV SC Bank 콘덴서 절연파괴 대책연구)

  • Ju H.J.;Khak J.S.;Woo J.W.;Kang Y.W.;shim E.B.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.537-540
    • /
    • 2004
  • 154 kV 변전소에 설치 운전 중인 SC Bank콘덴서 셀의 절연파괴 고장이 빈번하게 발생되어 전력계통의 운용 덴 변전소 운전에 지장을 주는 사례가 많이 발생하였다. 따라서 이의 고장원인 진단을 통하여 대책수립을 하고자 EMTP(Electro-Magnetic Transient Program)를 이용하여 50의 SC Bank의 정상상태시 과전압, 과전류에 의한 소손현상을 검토하고, 계통조건에 따른 공진점변화와 고조파에 따른 이상전압 및 콘덴서 셀 전압의 상승 현상을 검토 분석하고, 현장 실측을 통하여 고조파성분에 따른 과전압 및 과전류를 분석하여 대책을 제시한 사례 연구의 결과이다.

  • PDF

Development of Connecting Plug and Phase Connecting Device for VLF Diagnosis of Underground Cables (지중케이블 VLF진단용 삽입형 연결장치 및 상간연결장치 개발)

  • Joo, Jong-Min;Park, Sang-Wan;Jung, Han-Ju;An, Jin-Sub;Lee, Se-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1485-1486
    • /
    • 2015
  • 경제성장과 인구증가에 따른 전력수요의 증가는 특고압 배전계통선로 건설의 필요성을 증대시키고 있으며, 환경 개선을 원하는 고객의 요구에 따라 배전계통의 지중화율은 향후 지속적으로 증가할 것으로 보인다. 80년대에 시설된 지중배전케이블은 20년간의 장기 사용으로 인하여 열화에 의한 고장이 증가하고 있는 상태이다. 그러나 사용환경이 양호한 곳의 케이블은 여전히 정상 성능을 보이는 경우도 많이 있다. 따라서 사용기간에 따라 일괄적으로 케이블 교체하는 것은 경제적이지 못하며, 사용 기간에 따라 교체하더라도 초기에 고장률이 높은 경우가 있기 때문에 케이블의 교체만으로 고장을 방지하는 효과가 최대로 나타나기는 어렵다. 따라서 열화가 많이 진행되어 고장 발생 확률이 높은 케이블을 선별하여 교체하는 것이 고장확률을 줄이고 경제적이다.

  • PDF