• Title/Summary/Keyword: 진공 환경

Search Result 623, Processing Time 0.028 seconds

Enhanced Bioslurping System for Remediation of Petroleum Contaminated Soils (Enhanced Bioslurping system을 이용한 유류오염 토양의 복원)

  • Kim Dae-Eun;Seo Seung-Won;Kim Min-Kyoung;Kong Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.2
    • /
    • pp.35-43
    • /
    • 2005
  • Bioslurping combines the three remedial approaches of bioventing, vacuum-enhanced free-product recovery, and soil vapor extraction. Bioslurping is less effective in tight (low-permeability) soils. The greatest limitation to air permeability is excessive soil moisture. Optimum soil moisture is very soil-specific. Too much moisture can reduce air permeability of the soil and decrease its oxygen transfer capability. Too little moisture will inhibit microbial activity. So Modified Fenton reaction as chemical treatment which can overcome the weakness of Bioslurping was experimented for simultaneous treatment. Although the diesel removal efficiency of SVE process increased in proportion to applied vacuum pressure, SVE process was difficulty to remediation quickly semi- or non-volatile compounds absorbed soil strongly. And SVE process had variation of efficiency with distance from the extraction well and depth a air flow form of hemisphere centering around the well. Below 0.1 % hydrogen peroxide shows the potential of using hydrogen peroxide as oxygen source but the co-oxidation of chemical and biological treatment was impossible because of the low efficiency of Modified Fenton reaction at 0.1 % (wt) hydrogen peroxide. NTA was more efficiency than EDTA as chelating agent and diesel removal efficiency of Modified Fenton reaction increased in proportion to hydrogen peroxide concentration. Hexadecane as typical aliphatic compound was removed less than Toluene as aromatic compound because of its structural stability in Modified Fenton reaction. What minimum 10% hydrogen peroxide concentration has good remediation efficiency of diesel contaminated groundwater may show the potential use of Modified Fenton reaction after bioslurping treatment.

Improvement of Oxygen Isotope Analysis in Seawater samples with Stable Isotope Mass Spectrometer (질량분석기를 이용한 해수 중 산소안정동위원소 분석법의 개선)

  • Park, Mi-Kyung;Kang, Dong-Jin;Kim, Kyung-Ryul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.4
    • /
    • pp.348-353
    • /
    • 2008
  • Oxygen isotope has not been used actively in water mass studies because of difficulties on the analysis though it has advantages as a water mass tracer. The most popular method to analysis the oxygen isotope ratio in water samples is equilibration method: isotopic equilibrium of water with $CO_2$ at constant temperature. The precision of oxygen isotope analysis using commercial automatic $H_2O/CO_2$ equilibrator is ${\pm}0.1%o$. This value is not sufficient for studies in open ocean. The object of this study is to improve the analytical precision enough to apply open ocean studies by modification of the instrument. When sample gas is transferred by the pressure difference, the fractionation which is preferential transportation of light isotope can be occurred since the long transportation path between the equilibrator and mass spectrometer. And the The biggest source of error during the analysis is long distance and large volume of the pathway of sample gas between. Therefore, liquid nitrogen trap and high vacuum system are introduced to the system. The precisions of 14 time analysis of same seawater sample are ${\pm}0.081%o$ and ${\pm}0.021%o$ by built-in system and by modified system in this study, respectively.

High Efficiency Active Phased Array Antenna Based on Substrate Integrated Waveguide (기판집적 도파관(SIW)을 기반으로 하는 고효율 능동 위상 배열안테나)

  • Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.3
    • /
    • pp.227-247
    • /
    • 2015
  • An X-band $8{\times}16$ dual-polarized active phased array antenna system has been implemented based on the substrate integrated waveguide(SIW) technology having low propagation loss, complete EM shielding, and high power handling characteristics. Compared with the microstrip case, 1 dB less is the measured insertion loss(0.65 dB) of the 16-way SIW power distribution network and doubled(3 dB improved) is the measured radiation efficiency(73 %) of the SIW sub-array($1{\times}16$) antenna element. These significant improvements of the power division loss and the radiation efficiency using the SIW, save more than 30 % of the total power consumption, in the active phased array antenna systems, through substantial reduction of the maximum output power(P1 dB) of the high power amplifiers. Using the X-band $8{\times}16$ dual-polarized active phased array antenna system fabricated by the SIW technology, the main radiation beam has been steered by 0, 5, 9, and 18 degrees in the accuracy of 2 degree maximum deviation by simply generating the theoretical control vectors. Performing thermal cycle and vacuum tests, we have found that the SIW array antenna system be eligible for the space environment qualification. We expect that the high efficiency SIW array antenna system be very effective for high performance radar systems, massive MIMO for 5G mobile systems, and various millimeter-wave systems(60 GHz WPAN, 77 GHz automotive radars, high speed digital transmission systems).

A Study for Failure Examples of Emission Gas Recirculation and Air Control and Catalyzed Particulate Filter System in Diesel Engine Vehicle (디젤엔진 자동차의 EGR 및 공기 제어와 CPF 장치에 관련된 고장사례 고찰)

  • Lee, IL Kwon;Kook, Chang Ho;Ham, Sung Hoon;Lee, Young Suk;Youm, Kwang Wook;You, Chang Bae;Kim, Sung Mo;Lim, Ha Young;Ahn, Ho Cheol;Lee, Jeong Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.78-83
    • /
    • 2018
  • The purpose of this paper is to study for failure examples of emission gas recirculation and air control and catalyzed particulate filter system in diesel engine vehicle. The first example, the researcher found the fact that the much engine oil came into the intake manifold causing diaphragm damage of EGR valve. The engine oil entered into combustion chamber of engine so that a car emit the polluted exhaust gas when driving. The second example, the researcher certified the sticking phenomenon of carbon and foreign substance with the throttle flap so that the exhaust fumes discharged exhaust port. The third example, the regeneration function don't activated to not detect the temperature of exhaust gas because of damage in the sensor. Thus, the researcher must meticulously manage his car not in order to take place the problem of environmental pollution.

Capsule Train Dynamic Model Development and Driving Characteristic Analysis Considering the Superconductor Electrodynamic Suspension (초전도 유도 반발식 부상특성을 고려한 캡슐트레인 동특성 해석 모델 구축 및 주행 특성 분석)

  • Lee, Jin-Ho;Lim, Jungyoul;You, Won-Hee;Lee, Kwansup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.38-45
    • /
    • 2020
  • A magnetically levitating capsule train, which runs inside the sub-vacuum tube, can reach ultra-fast speeds by dramatically reducing the aerodynamic drag and friction. The capsule train uses the superconductor electrodynamic suspension (SC-EDS) method for levitation. The SC-EDS method has advantages, such as a large levitation gap and free of gap control, which could reduce the infra-construction cost. On the other hand, disadvantages, such as the large variation of the levitation-guidance gap and small damping characteristics in levitation-guidance force, could degrade the running stability and ride comfort of the capsule train. In this study, a dynamic analytical model of a capsule train based on the SC-EDS was developed to analyze the running dynamic characteristics. First, as important factors in the capsule train dynamics, the levitation and guidance stiffness in the SC-EDS system were derived, which depend non-linearly on the velocity and gap variation. A 3D dynamic analysis model for capsule trains was developed based on the derived stiffness. Through the developed model, the effects of the different running speeds on the ride comfort were analyzed. The effects of a disturbance from infrastructure, such as the curve radius, tube sag, and connection joint difference, on the running stability of the capsule train, were also analyzed.

Development of Portable Preconcentration-Gas Chromatography System for Fast Analysis of Trace Benzene, Toluene and Xylene in Air (대기 중 극미량의 벤젠, 톨루엔 및 자일렌의 신속한 분석을 위한 휴대용 농축-기체 크로마토크래피 시스템 개발)

  • Jung, Young-Rim;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.432-441
    • /
    • 2001
  • An automated on-line portable preconcentration-short column gas chromatograph was developed, which used preconcentrator using adsorption tube with Tenax-GR and Curie-point heating. The developed system operated with 3 steps of processing, preconcentration, thermal desorption, and analysis and cleaning, and could continued operating within 1~2 min cycle. The recoveries of preconcentrator for toluene was ranged between $94.7{\pm}6.6%$ and $103.8{\pm}3.1%$ with less than 7% of RSD. For benzene, toluene and xylene(BTX) standard gas test, IDL was 41, 49, $472ng/m^3$ benzene, toluene and o-xylene, respectively. The BTX mixture was analyzed within 30 sec with baseline separation by the system equipped with 4 m long capillary column. The deficiency of separation power caused by short column was solved by the control of sample injection volume and inlet/outlet pressure ratio. The automated portable preconcentration-short column gas chromatograph system was found to be useful for the continuous air monitoring of BTX at ppb levels in ambient air.

  • PDF

Enhancement of cyanoacrylate-developed marks using p-dimethylaminobenzaldehyde (DMAB) on semi-porous surfaces and analysis of the influence factors on fluorescence intensity (반다공성 재질에 유류된 지문의 CA 훈증 후 p-dimethylaminobenzealdehyde(DMAB) 형광시약 적용 시 표면적과 주변 온도, 기압이 형광착색에 미치는 효과에 관한 연구)

  • Yu, Je-Sul;Kim, Ju-Hah
    • Analytical Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.187-195
    • /
    • 2014
  • It is very important to minimize the damage of latent fingerprints at enhancing the contrast. This study proves the enhancement effects of cyanoacrylate-fumed latent fingerprints using p-dimethylaminobenzealdehyde (DMAB) on semi-porous surfaces and the influence factors. The latent fingerprints in experiment were developed for cyanoacrylate treatment in a vacuum chamber and used after drying at room temperature for 24 hours. For fluorescence staining, the cyanoacrylate-developed marks using DMAB were sublimated during 48 hours under the different conditions of surface area, temperature, atmospheric pressure. First experiment showed how surface area effects on the sublimation rate and fluorescence intensity by DMAB of particle size and container size. In addition, the fluorescence staining using DMAB with solvent-free contact method had the greatest fluorescence intensity after 36 hours and a low fluorescence intensity over a certain size of surface area. Second experiment showed that the evaporation of DMAB solid crystals got a satisfying result in a temperature of $20^{\circ}C$ and reduced time to get the greatest fluorescence intensity. It took a long time to get a optimum level of fluorescence intensity at $30^{\circ}C$ or more and it was less effective in fluorescence intensity. Third experiment on the pressure indicated that the fluorescence intensity of vacuum was weaker than nonvacuum but it was inapplicable to very high variations in pressure.

Flight model development of the NISS structure for NEXTSat-1 payload

  • Moon, Bongkon;Ko, Kyeongyeon;Lee, Duk-Hang;Jeong, Woong-seob;Park, Sung-Joon;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Won-Kee;Kim, Il-Joong;Park, Youngsik;Kim, Mingyu;Nam, Ukwon;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.87.3-88
    • /
    • 2017
  • 한국천문연구원은 차세대소형위성 1호의 근적외선 영상분광기 NISS (Near-infrared Imaging Spectrometer for Star formation history) 탑재체를 개발하여 2017년 6월 30일에 최종 비행모델을 납품하였고, 이 발표는 탑재체 NISS 구조체의 비행모델 개발 결과를 보고한다. NISS는 0.9 - 2.5um (R~20) 근적외선 파장에서 관측을 해야 하기 때문에, 구조체의 배경잡음을 없애기 위해서 200K까지 passive cooling으로 냉각되며, H2RG 검출기는 소형 냉동기에 의해 약 88K에서 운영된다. NISS 구조체의 passive cooling을 효율적으로 수행하기 위해서 방열판, Kevlar 지지대, MLI, 표면제어용 필름 등을 조립하였고, 실제 지상 시험을 통해서 그 성능을 확인하였다. NISS 구조체는 최종 시스템 조립 과정에서 전자부 하네스 조립을 함께 수행했으며, 온도 모니터링 센서를 부착하고 소형 냉동기 피드백 온도를 반복 시험을 통해서 결정하였다. NISS 구조체는 미러 및 렌즈를 지지하는 광기계부를 함께 포함하기 때문에 발사 및 우주환경에서 광학 성능을 유지하기 위한 설계를 거쳐서 제작 되었으며, 최종 시스템 검교정 시험, 진동 및 열진공 시험을 통해서 그 성능을 확인하였다. NISS를 탑재한 차세대소형위성 1호는 2018년 상반기에 미국의 Falcon 9 발사체에 실려서 발사될 예정이다.

  • PDF

Effects of High Dose Gamma Irradiation on Shelf Stability and Lipid Oxidation of Marinated and Precooked Pork Rib Steak (고선량 감마선 조사가 즉석 취식용 양념 돼지 갈비 구이의 저장성 및 지질 산화에 미치는 영향)

  • Lee, Ju-Woon;Park, Jae-Nam;Kim, Jae-Hun;Park, Jin-Gyu;Kim, Cheon-Jei;Kim, Kwan-Soo;Byun, Myung-Woo
    • Food Science of Animal Resources
    • /
    • v.26 no.4
    • /
    • pp.471-477
    • /
    • 2006
  • This study was conducted to evaluate the application of high dose irradiation for ensuring shelf stability of marinated and precooked pork rib steak in the severe environments such as desert or space, etc. Marinated and precooked pork rib steak was manufactured, vacuum-packaged and gamma-irradiated with the absorbed doses of 10, 20, 30, 40 and 50 kGy, and used for the tests of the growth of microorganisms and lipid oxidation during storage at 35t of acceleration condition. Any growth of microorganisms was not observed in irradiated samples after irradiation immediately. However, the growths were observed in 10, 20 and 30 kGy samples at 4, 7 and 14 day storage, respectively. High dose (40 and 50 kGy) gamma irradiation retarded the growth of aerobic microorganisms by the analysis of kinetic parameter. The content of malondialdehyde increased in all samples during storage periods, and gamma irradiation accelerated the increase of lipid oxidation. Therefore, the application of combination of the various food processing technology should be considered for the sterilization of marinated and precooked pork rib steak without any deterioration of the quality occurred by high dose irradiation.

The Effect of Deposition Parameters on the Morphology of KLN Thin Films (증착 조건이 KLN 박막의 형상에 미치는 영향)

  • Park, Seong-Geun;Jeon, Byeong-Eok;Kim, Jin-Su;Kim, Ji-Hyeon;Choe, Byeong-Jin;Nam, Gi-Hong;Ryu, Gi-Hong;Kim, Gi-Wan
    • Korean Journal of Materials Research
    • /
    • v.11 no.1
    • /
    • pp.27-33
    • /
    • 2001
  • The growth characteristics of 4-fold grain which was appeared in KLN deposition on $Pt/Ti/SiO_2/Si(100)$ substrate was studied by varying process variables. Substrate temperature, sputtering pressure, rf power were selected as process variables, and experiment was carried out near optimum fabrication condition. When using K and Li enriched target, the optimum fabrication conditions were substrate temperature of $600^{\circ}C$, sputtering pressure of 150mTorr, rf power of 100 W and its surface morphology is sensitively varied by small deposition condition changes. KLN is composed of elements which have large difference of boiling point. And it is difficult to fabricate thin film at high temperature and high vacuum deposition condition. Furthermore the phenomenon during deposition process can not be explained by using Thorton's model which explains the relation between thin film structure and melting point of thin film materials. These phenomenon can be explained using boiling point of elements which consist of thin film material.

  • PDF