• Title/Summary/Keyword: 직통

Search Result 14, Processing Time 0.022 seconds

Legal Reviews and Countermeasures against Violence to 119 Emergency Medical Technicians (EMT) (119구급대원의 폭행피해에 대한 법적인 고찰 및 대응방안)

  • Lim, Jae-Man;Choi, Eun-Sook
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.154-161
    • /
    • 2010
  • There have been various discussions to prevent violence to 119 emergency medical technicians, and the aims of the were as follow ; first, the staff dispatched to the scene should be reinforced so that the patients committing violent acts can be subdued. Secondly, self-defense devices should be provided to 119 emergency medical technicians so that they can use them in a dangerous situation and escape from it. And finally, 119 emergency medical technicians should be allowed to refuse to transport the patients when they or their guardians do violence to them in order to prevent potential violent cases. When countermeasures after violence is committed, it is important to secure evidence and determine strongly to bring charges to the offenders rather than agree to overlook the violence in order to correct them right. It is necessary to introduce a support program to help the victim technicians concentrate on their physical and mental treatment. Violence to 119 EMT should be punished so that the society will think it is natural to punish such offenders. In a safer environment, 119 EMT can perform their duties and it is very important to draw this consensus.

The Evaluation for Running Safety of Incheon International Airport Railway EMU (인천국제공항철도 전동차의 주행안전성 평가)

  • Hong, Yong-Ki;You, Won-Hee;Lee, Hi-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.619-625
    • /
    • 2007
  • The dynamic characteristic test result of electric rail car which is operated in Incheon International Airport Railroad is described in this paper. Express train in Incheon International Airport Railroad drives at 120km/h first in the country and derailment coefficient was measured for empty car and full-loaded car respectively. The measurement result of derailment coefficient, a key safety indicator about derailment, of empty car was higher than full-loaded car and both were lower than 0.8. The railway state wasn't good in operated section where is serviced about 80eh and derailment coefficient also increased. Horizontal pressure was below 2.1 ton at empty car and below 2.4 ton at full-loaded car. The electric rail car in Incheon International Airport Railroad has been confirmed it's running safety at 120km/h by the measurement of derailment coefficient. But the way of assessing applied in this paper has demerits such as complication of test method, difficulty for measurement device installation and high cost. Therefore the method which is simple to measure and can certify vehicle's safety even when service driving has to be researched.

A Study on the Efficiency of Evacuation Exterior Stairs in High-rise Buildings (고층빌딩에서 옥외피난계단의 효용성에 관한 연구)

  • Choi, Kyu-Chool
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.63-69
    • /
    • 2009
  • Article 36 of the Building Code Enforcement Ordinance requires that an exterior evacuation stairs be installed for the buildings of three stories and over with cultural facilities or gathering places which have over $1,000\;m^2$ floor area of public performance halls or recreational facilities. The concentration of population together with the increase of high-rise buildings in cities call for various precautionary measures to be taken against human disasters. For the past ten years high-rise buildings showed 85% of increase, marking a steep rise. This increase of high-rise buildings may lead to human disasters in urban areas and, in case of fire breakout, may cause great loss of human lives and property damages. The most difficult fire-fighting activities in high-rise building fires are those of evacuation. Because smoke spreads through the upper floors, the securement of evacuation route in high-rise buildings may be the only way to minimize loss of lives. In high-rise buildings exterior escape stairs are necessary because it is difficult to secure evacuation route with only direct stairs or interior stairs. The Building Code now in force provides insignificant coverage on the exterior evacuation route installment and therefore becomes an inadequate means for evacuation route securement in high-rise building fires. To compensate for this inadequacy the Building Code should be revised to include a mandatory clause that an exterior evacuation stairs be established for the buildings of ten stories and over which can be categorized into high-rise building group.

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.