• Title/Summary/Keyword: 직접인장

Search Result 273, Processing Time 0.026 seconds

An Experimental Study on Tensile Properties of Steel Fiber-Reinforced Ultra High Strength Concrete (강섬유 보강 초고강도 콘크리트의 인장 특성 실험 연구)

  • Yang, In-Hwan;Park, Ji-Hun;Lee, Jae-Ho
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.3
    • /
    • pp.279-286
    • /
    • 2019
  • In this study, an experimental study on the tensile properties of steel fiber-reinforced ultra high strength concrete(UHSC) with a standard compressive strength of 180MPa was performed. Steel fibers with a volume ratio of 1% were mixed to prepare direct tensile strength specimens and prism specimens for the three-point bending test. The fabricated specimens were set up in the middle section of the specimen to induce cracks, and the test was carried out according to each evaluation method. First, the stress-strain curves were analyzed by performing direct tensile strength tests to investigate the behavior characteristics of concrete after cracking. In addition, the load-CMOD curve was obtained through the three-point bending test, and the inverse analysis was performed to evaluate the stress-strain curve. Tensile behavior characteristics of the direct tensile test and the three-point bending test of the indirect test were similar. In addition, the tensile stress-strain curve modeling presented in the SC structural design guidelines was performed, and the comparative analysis of the measured and predicted values was performed. When the material reduction factor of 1.0 was applied, the predicted value was similar to the measured value up to the strain of 0.02, but when the material reduction factor of 0.8 was applied, the predicted value was close to the lower limit of the measured value. In addition, when the strain was greater than 0.02, the predicted value by SC structural design guideline to underestimated the measured value.

Tensile Behavior of Ultra-High Performance Concrete According to Combination of Fibers (섬유 조합에 따른 초고성능 콘크리트의 인장거동)

  • Choi, Jung-Il;Koh, Kyung-Taek;Lee, Bang-Yeon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.49-56
    • /
    • 2015
  • Ultra-High Strength Concrete(UHPC) has ultra-high material performance including high strength and high flowability. On the other hand it is less ductile than high ductile fiber reinforced cementitious composite. This study investigated the effect of combination of steel fiber and micro fiber on the tensile behavior of UHPC. Four types of UHPC containing combination of steel fiber, polyethylene(PE), polyvinyl alcohol(PVA), and basalt fiber were designed. And then uniaxial tension tests were performed to evaluate the tensile behavior of UHPC according to combination of fibers. And density was measured to evaluate whether micro fiber induces unintentional high pore or not. From the test results, it was exhibited that PE fiber with high strength is effective to improve the tensile behavior of UHPC and basalt fiber is effective to increase the cracking and tensile strength of UHPC. Furthermore, it was also verified that micro fiber does not make high pore.

Study on ECC Tensile Behavior due to Constrained Drying Shrinkage (구속된 건조수축에 따른 ECC의 인장거동에 관한 연구)

  • Lee, Do-Keun;Lee, Kyoung-Chan;Lee, Chi-Dong;Shin, Kyung-Joon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.367-374
    • /
    • 2019
  • Drying shrinkage in the hardened cement is known to change in volume by decreasing the moisture content in the hardened body, and it is known that the higher the W / C and the higher the content of the paste, the larger the drying shrinkage. In the case of ECC, more drying shrinkage occurs compared to concrete, since it does not contain coarse aggregate. Since ECC is an important material for tensile performance, the effect of restrained tensile stress on mechanical tensile behavior should be considered. The purpose of this study is to analyze the effect of stress caused by restraint on the tensile behavior of ECC. The mechanical properties of the specimens were tested by uniaxial tension tests with different restraints. As a result, the difference of tensile behavior according to restraint stress was observed and the cause was analyzed.

A Study on the Characteristics of Direct Tensile Fatigue of the Domestic PS Bar at High Stress Range (국산 PS 강봉의 고응력범위에서의 직접 인장피로 특성)

  • Yoo, Sung Won;Suh, Jeong In
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.2
    • /
    • pp.137-145
    • /
    • 2003
  • In this study, direct tensile fatigue tests of the PS bar were performed in terms of diameter, minimum stress level, and maximum stress level. In the static test, the stress - strain curve and ultimate streng th of the PS bar were determined. Results of the fatigue test indicate that the diameter of the PS bar was not influenced by fatigue life. Minimum stress also had quite an influence on the fatigue of the PS bar. Thus, the fatigue characteristic equation was proposed in terms of stress range and minimum stress through statistical process. Strains on specimen that loaded direct tension were measured in the fatigue test, with the secant modulus of elasticity calculated from measured strains. The strain development consisted of three different stages, i.e., rapid increases during the initial fatigue life, uniform increases during the middle stage, and rapid increases until failure. The secant modulus of elasticity decreased during the fatigue life with increasing strain. However, stress level seemed to have no influence on the secant modulus of elasticity.

Evaluation of SHCC on Direct Tensile Load using Acoustic Emission Technique (음향방출기법을 이용한 혼입되는 섬유의 종류에 따른 SHCC의 직접인장거동특성 평가)

  • Kim, Yun-Su;Yun, Hyun-Do;Jeon, Esther;Park, Wan-Shin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.177-180
    • /
    • 2008
  • SHCC shows the high energy tolerance capacity due to the interfacial bonding of the fibers to the cement matrix. For effective material design and application of SHCC, it is needed to investigate the damage process and micro-fracture mechanism of cement matrix reinforced with different types of fibers. The objective of this paper is to investigate the direct tensile response of cement composites reinforced with single and hybrid fibers using acoustic emission(AE) technique. In this study, the correlations between AE signal and result of the direct tensile response of SHCC. For these purposes, three kinds of fibers were used: PET1.5%, PET1.0+PE0.5%, PET1.0%+PVA0.5%. The result of the direct tensile response of SHCC, for the same volume fraction of fibers, ultimate strength of PET-PE specimen was 2.7 times higher than specimens with PET fibers. And from AE signal value, AE event numbers and cumulative energy were different according to kind of fiber because of the different material properties of reinforced fiber.

  • PDF

Mechanical Properties of Green Strain-Hardening Cement-based Composites with Recycled Materials (순환재료를 사용한 그린 변형 경화형 시멘트 복합체의 역학적 특성)

  • Yun, Hyun-Do;Kim, Sun-Woo;Lee, Young-Oh;Nam, Sang-Hyun;Cha, Jun-Ho;Kim, Yun-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.399-400
    • /
    • 2010
  • This paper presents results of an experimental program for evaluating the mechanical properties of green strain-hardening cementitious composite (SHCC) using recycled material. Recycled poly ethylene terephthalate (PET) fiber, fly ash, and recycled sand from waste concrete are used as materials for green SHCC. Test results indicated that average tensile strength of five dumbbell-shaped specimen is 4.76MPa and average compressive and flexural strength of three specimens are 38MPa and 7.40MPa, respectively.

  • PDF

Characterization of In-plane Shear Behaviors of Woven Fabrics by Bias-extension and Trellis-frame Tests (편향 인장 및 트렐리스 시험에 의한 직물 복합재료의 면내 전단 물성 평가)

  • Lee, Won-Oh;Um, Moon-Kwang;Byun, Joon-Hyung;Cao, Jian
    • Composites Research
    • /
    • v.23 no.5
    • /
    • pp.8-14
    • /
    • 2010
  • Three types of glass woven fabrics (plain, balanced twill, and unbalanced twill) having various sample sizes and aspect ratios were tested using the bias-extension tests. Real-time deformation images, force, and displacement data were collected. For the bias-extension test, the shear angle of the fabrics from the equation based on the crosshead displacement and fabric size was compared with direct manual measurements of the warp and weft angles as well as the optical measurement software. To determine the shear force, an analytical equation was introduced considering the kinematics of the bias-extension test. The obtained shear behaviors were further compared with the results by the trellis-frame test. The optical measurement methods showed that the mathematical method was reasonable before the shear angle of the fabrics reaches $30^{\circ}$ in the bias-extension tests. Also, the bias-extension test gave consistent behaviors with the trellis-frame test only for isotropic and homogeneous fabrics such as balanced plain and twill weaves.

Experimental Investigations on Tensile Strength of Sand at Low Moisture Contents (저함수비 모래의 인장강도에 대한 실험적 연구)

  • Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.23-31
    • /
    • 2002
  • This study shows that tensile strength in moist sand clearly exists due to moisture and it is possible to simply and accurately measure the tensile strength of sands at low moisture contents. These measurements were made through the use of a newly developed direct tension apparatus and technique which are able to produce highly accurate results. The magnitudes of the tensile strengths of these moist and relatively clean sands are not equal to zero, as is widely assumed. Tensile strength increases with increasing moisture content and this trend is more noticeable at increasing relative densities. The influence of tensile strength in geotechnical problems was also examined by considering a simple rigid circular footing in sandy soil. It clearly shows that a small amount of tensile strength can significantly enhance the stability of a geotechnical system.

인장시편 및 응력동결된 디스크의 프린지 상수 측정에 의한 다목적 편광기 성능시험

  • Baek, Tae-Hyun;Kim, Myung-Soo;Kim, Dong-Hyun;Lee, Chun-Tae;Kim, Hwan;Park, Tae-Geun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.178-178
    • /
    • 2004
  • 본 연구에서는 폴리카보나이트의 재료로 만들어진 인장시편과 원형시편을 다목적 광탄성 측정기를 사용하여 프린지 차수를 측정한 후 프린지 상수를 도출하였다. 특히, 새로 개발된 다목적 광탄성기를 이용하여 지랫대 형식으로 프린지 차수를 측정하였고, 시편에 직접 응력을 가하는 방식의 직접(DIRECT) 실험법으로 프린지 차수를 측정하였다. 위와 같은 방식은 나타난 결과를 가지고 프린지 상수를 서로 비교할 수 있다는 장점이 있어 다목적 광탄성기에 대한 신뢰도를 얻을 수 있다 아울러 광탄성 4단계 위상 이동법에서는 주응력 방향, 즉 등경선이 일정한 선상에서는 연속적인 응력분포를 얻을 수 있다.(중략)

  • PDF

Direct Tensile Properties of Fiber-Reinforced Cement Based Composites according to the Length and Volume Fraction of Amorphous Metallic Fiber (비정질 강섬유의 길이 및 혼입률에 따른 섬유보강 시멘트복합체의 직접인장특성)

  • Kim, Hong-Seop;Kim, Gyu-Yong;Lee, Sang-Kyu;Choe, Gyeong-Cheol;Nam, Jeong-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.3
    • /
    • pp.201-207
    • /
    • 2019
  • In this study, the direct tensile properties of amorphous metallic fiber-reinforced cement based composites according to the strain was evaluated. A thin plate-shape amorphous metallic fiber with 15mm and 30mm in length was used. And fiber-reinforced cement based composites were prepared with contents of 1.0, 1.5, 2.0%. The direct tensile test was conducted under the conditions of $10^{-6}/s(static)$ and $10^1/s(dynamic)$ strain rate. As a results, amorphous metallic fiber with a length of 15mm was observed in pull-out behavior from the cement matrix because of the short fiber length and large portion of mixed fiber. On the other hand, amorphous metallic fiber with a length of 30mm were not pulled out from matrix because the bonding force between the fiber and matrix was large due to rough surface and large specific surface area. However, fracture occurred because thin plate shape fibers were vulnerable to shear force. Tensile strength, strain capacity and toughness were improved due to the increase in the fiber length. The dynamic increase factor of L15 was larger that of L30 because the bonding performance of the fiber-matrix interface is significantly affected by the strain rate.