• Title/Summary/Keyword: 직선검출

Search Result 602, Processing Time 0.022 seconds

Development and Validation of Analytical Method for Decursin in Aerial Parts of Angelica gigas Nakai Extract (참당귀 지상부 추출물의 지표성분 decursin의 분석법 개발 및 검증)

  • Kim, Hee-Yeon;Lee, Ki-Yeon;Kim, Tae-Hee;Park, A-Reum;Noh, Hee-Sun;Kim, Si-Chang;Ahn, Mun-Seob
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.52-57
    • /
    • 2019
  • Method development and validation of decursin for the standardization of Angelica gigas Nakai as a functional ingredient and health food were accomplished. The quantitative determination method of decursin as a marker compound of aerial parts of Angelica gigas Nakai extract (AAGE) was optimized by HPLC analysis using a C18 column ($3{\times}150mm$, $3{\mu}m$) with 0.1% TFA in water and acetonitrile as the mobile phase at a flow rate of 0.5 mL/min and detection wavelength of 330 nm. The HPLC/PDA method was applied successfully to quantification of the marker compound in AAGE after validation of the method with linearity, accuracy, and precision. The method showed high linearity in the calibration curve at a coefficient of correlation ($R^2$) of 0.9994 and the limit of detection and limit of quantitation were $0.011{\mu}g/mL$ and $0.033{\mu}g/mL$, respectively. Relative standard deviation (RSD) values of data from intra- and inter-day precision were less than 1.10% and 1.13%, respectively. Recovery of decursin at 0.5, 1, 5 and $10{\mu}g/mL$ were 92.38 ~ 104.11%. These results suggest that the developed HPLC method is very useful for the determination of marker compound in AAGE to develop a health functional material.

Validation of a trienzyme-Lactobacillus casei method for folate analysis in fishery resources consumed in the Korean diet (Trienzyme과 Lactobacillus casei를 이용한 국내 수산 자원의 엽산 분석 및 유효성 검증)

  • Jeong, Bomi;Nam, Ki-Ho;Kim, Yeon-Kye;Chun, Jiyeon
    • Korean Journal of Food Science and Technology
    • /
    • v.52 no.6
    • /
    • pp.580-586
    • /
    • 2020
  • Fishery resources have been widely consumed as protein- and vitamin-rich food sources in the Korean diet. However, information regarding their vitamin levels is extremely limited. In this study, trienzyme-Lactobacillus casei method was validated and used to determine the folate contents in fishery foods. The trienzyme-L. casei method for folate analysis showed excellent accuracy (85.2 to 95.3% recovery) and precision (repeatability 1.4% RSD and reproducibility 2.4% RSD). Folate contents of 20 fish foods (4 fish, 3 crustaceans, 3 sea algae, 3 cephalopods, 4 shellfish, and 3 others) ranged from 1.75 to 97.98 ㎍/100 g. Furthermore, we found that the folate content in seaweed fusiforme was the highest, followed by gulfweed (69.73 ㎍/100 g). Folate analysis using the trienzyme-L. casei method was determined excellent based on the z-score of -0.3 in the Food Analysis Performance Assessment Scheme test. Analytical and method validation data generated in this study could be used to update the national food composition table on vitamin B9 in Korean fishery resources.

Determination and Validation of Synthetic Antioxidants in Processed Foods Distributed in Korea

  • Park, Hyeon-Ju;Seo, Eunbin;Park, Jin-Wook;Yun, Choong-In;Kim, Young-Jun
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.5
    • /
    • pp.297-305
    • /
    • 2022
  • Antioxidants are food additives that extend the shelf life of food products by preventing lipid rancidity caused by active oxygen. They can either be naturally-derived or manufactured synthetically via chemical synthesis. In this study, method validation of five synthetic antioxidants, namely butylated hydroxyanisole, butylated hydroxytoluene, tertiary butylhydroquinone, propyl gallate, and disodium ethylenediaminetetraacetic acid, was performed using a high performance liquid chromatography-ultraviolet visible detector, and the method applicability was evaluated by analyzing foods containing antioxidants. The coefficient of determination (R2) average was 0.9997, while the limit of detection and limit of quantification were 0.02-0.53 and 0.07-1.61 mg/kg, respectively. The intra and inter-day accuracies and precisions were 83.2±0.7%-98.7±2.1% and 0.1%-5.7% RSD, respectively. Inter-laboratory validation for accuracy and precision was conducted using the Food Analysis Performance Assessment Scheme quality control material. The results satisfied the guidelines presented by the AOAC International. In addition, the expanded uncertainty was less than 16%, as recommended by CODEX. Consequently, to enhance public health safety, the results of this study can be used as basis data for evaluating the intake of synthetic antioxidants and assessing their risks in Korea.

Analytical Method of Multi-Preservatives in Cosmetics using High Performance Liquid Chromatography (HPLC 를 이용한 화장품 중 살균보존제 다성분 동시분석법 연구)

  • Min-Jeong, Lee;Seong-Soo, Kim;Yun-Jeong, Lee;Byeong-Chul, Lee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.4
    • /
    • pp.321-330
    • /
    • 2022
  • This study attempted to establish an optimal multi-compound simultaneous analysis method that can secure reliable results for 15 - preservatives, 2 - sun screens and 1 - antioxidants of cosmetics using HPLC-PDA. Since the potential of hydrogen (pH) in the mobile phase affects the acid dissociation constant (pKa) of the preservatives, and the peak retention time shift and area change were observed. The peak separation condition was established by adjusting the pH to 0.1% H3PO4 addition (mL) when preparing the mobile phase. As a results of method validation, the linearity correlation coefficient (R2) of above 0.999 were obtained, and accuracy 87.9 ~ 101.1%, 0.1 ~ 7.6% precision for two types of cosmetics (cream and shampoo). It was found that the limit of detection (LOD) was 0.1 ~ 0.2 mg/kg and the limit of quantitation (LOQ) was 2.0 ~ 4.0 mg/kg. In addition, it was possible to simultaneously separate p-anisic acid, a natural compound that was difficult to separate in HPLC due to the small difference from methylparaben, a synthetic preservatives. Through this study, it will be effectively used to secure quality control and safety for compound that need restrictions on use cosmetics.

Analysis Method of Surfactants for Identification of Residue Dishwashing Detergent (세척제 잔류량 확인을 위한 계면활성제 분석법 확립)

  • Park, Na-Youn;Lee, Sojeong;Kim, Jung Hoan;Kho, Younglim
    • Journal of the Korean Chemical Society
    • /
    • v.65 no.6
    • /
    • pp.433-440
    • /
    • 2021
  • Surfactants are organic compounds that have both hydrophilic and non-polar parts in one molecule, classified as non-ion, anion, cation, and amphoteric surfactants according to the charge of hydrophilic parts in aqueous state. A trace amounts may remain when vegetables and fruits are washed using type1 detergent (Vegetable and fruit detergent), and there is a possibility of exposure to the human body through ingestion. This study developed the simultaneous analysis method for 5 surfactants with LC-MS/MS for analysis of detergent residues after washing vegetables and fruits with detergent. The mobile phase used distilled water and acetonitrile containing 50 mM ammonium formate and 0.1% formic acid and was analyzed using a gradient method using XBridge BEH C8 column. The accuracy of the established method was 83.9-112.1%, and the precision was less than 20%. The detection limit was 7.0 (SLS) to 29.0 (SLES-N3) ㎍/L, and the correlation coefficient (r2) of calibration line regression was greater than 0.99, it is considered suitable for the analysis of trace amounts of surfactant components remaining in vegetables and fruits.

Optimization of solid-phase extraction for the liquid chromatography-tandem mass spectrometry analysis of basic drugs in equine urine (액체크로마토그래피-텐덤질량분석법을 위한 경주마 소변 중 염기성 약물의 고체상 추출법 최적화)

  • Shin, Hyun Du;Yang, Ji Suk;Jung, Mihye;Kim, Hyung-Seung;Youm, Jeong-Rok;Hu, Man Bae;Kim, Sung Jean;Han, Sang Beom
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.412-423
    • /
    • 2008
  • A procedure based on solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry has been developed for the simultaneous analysis of 55 basic drugs in equine urine. The test scope covers diversified classes of drugs including some ${\beta}$-blockers, ${\beta}$-agonists, antihypotensives, CNS stimulants, sedatives, tranquilizers, antidepressants, antihypertensives and so on. LC-MS/MS separation and quantification was carried out in positive electrospray ionization and multiple reaction monitoring (MRM) mode. Four different brands of mixed mode cation exchange SPE sorbents; UCT XTRACT$^{(R)}$ XRDAH, Supelco DSC-MCAX$^{(R)}$, Varian Bond Elut Certify$^{(R)}$ and Waters Oasis$^{(R)}$ MCX were compared. The UCT XTRACT$^{(R)}$ XRDAH sorbent provided the best results in the preconcentration of samples, yielding relative recoveries higher than 80% except for terbutaline (41.3%), salbutamol (71.5%), heptaminol (70.7%), phenylpropanolamine (66.3%). Detection limits of the target drugs provided by the proposed analytical procedure were between 0.2~8.3 ng/mL.

A sensitive analytical method for determination of 3-monochloropropane-1,2-diol and 1,3-dichloropropan-2-ol in various foods by gas chromatography with mass spectrometer (가스크로마토그래피/질량분석기를 이용한 식품 중 클로로프로판올 화합물 분석)

  • Kim, Eunju;Park, Sungkug;Choi, Dongmi
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.543-552
    • /
    • 2008
  • This paper described the relatively sensitive and simultaneous analytical method for 3-monochloropropane-1,2-diol (3-MCDP, $C_3H_7ClO_2$, MW. 110) as well as 1,3-dichloropropan-2-ol (1,3-DCP, $C_3H_6Cl_2O$, MW. 128) in various foods. Food samples were homogenized in 5M NaCl solution, mixed with aluminum oxide and eluted with dichloromethane. The extracted chloropropanols were concentrated by rotary evaporator and $N_2$ blow serially were derivatized with HFBA (Heptafluorobutyric anhydride, $C_8F_{14}O_3$, MW. 410) and were determined by GC/MS using isotope dilution method. The characteristic molecular ions at m/z 253, 275, 289, 291, and 453 for HFBA derivatives of 3-MCPD (MW. 502) and 110, 275, and 277 for HFBA derivatives of 1,3-DCP (MW. 325) were chosen in selected ion mode. The method validation data showed sufficiently good properties of LOD (0.003 mg/kg), LOQ (0.010 mg/kg), linearity ($R^2{\geq}0.999$ at 0.010~1.000 mg/kg), and recovery rate (${\approx}97%$). The levels of chloropropanols in soy sauce, sauces, processed meat products, fishery products, and seasonings (n=56/157) determined by the presented method were 0.0~0.3 mg/kg.

Simultaneous determination of amphetamine derivatives and norketamine in hair by GC-MS/MS (GC-MS/MS를 이용한 모발 중 암페타민 유도체 및 노르케타민 동시분석)

  • Kim, Jin Young;Shin, Soon Ho;Ko, Beom Jun;Chung, Jae Cheol;Suh, Yong Jun;In, Moon Kyo
    • Analytical Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.210-218
    • /
    • 2009
  • A gas chromatography-tandem mass spectrometry (GC-MS/MS) method was developed and validated for simultaneous determination of amphetamine derivatives and norketamine in human hair. Preparation of hair involves external decontamination, mechanical pulverization, incubation and extraction prior to instrumental analysis. The samples were derivatized using heptafluorobutyric anhydride, and analyzed by GC-MS/MS. The linear ranges were 0.05-20.0 ng/mg for the analytes except for 3,4-methylenedioxyamphetamine, with good coefficients of determination ($r^2$ >0.998). The intra-day and inter-day precisions were within 10.7% and 8.5%, respectively. The intra-day and inter-day accuracies were between -1.6 and 17.0% and -2.6 and 10.5%, respectively. The limits of detections for each analyte were lower than 0.007 ng/mg, while recoveries were 75.9-100.9%. When the method was applied to hair samples obtained from suspected drug abusers, the concentrations in hair samples were 0.97-19.30 ng/mg for methamphetamine and 0.14-2.56 ng/mg for amphetamine.

Determination of halogen elements in plastics by using combustion ion chromatography (연소IC를 이용한 플라스틱 중 할로겐 물질 정량)

  • Jung, Jae Hak;Kim, Hyo Kyoung;Lee, Yang Hyoung;Lee, Lim Soo;Shin, Jong Keun;Lee, Sang Hak
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.284-295
    • /
    • 2008
  • For plastics samples, a method using combustion ion chromatography was selected as a method for rapid low-cost analysis to test whether hazardous substances are contained or not. Using combustion ion chromatography, a verification test for F, Cl and Br compounds generated a linear calibration curve with a correlation coefficient of $r^2$ = 0.999~1.000 in the calibration range from 0.5 to 4.0 mg/kg. The detection limits were found to be 0.005~0.024 mg/kg and quantitative limits were found to be 0.014~0.073 mg/kg. The recoveries of combustion ion chromatography using certified reference material (CRM) were found to be 95.5~104.9%. Based on these results, a proficiency test was conducted together with several laboratories in and out of the country, to make comparative analysis of the results from each laboratory. As a result, the data supported the use of combustion ion chromatography as an effective analysis method to deal with regulations for halogen-free electronic products and for other hazardous substances in the electronic products.

Development of a rapid HPLC method for the determination of penciclovir in human plasma using a monolithic column and its application to a bioequivalence study (모노리틱 칼럼을 이용한 혈장 중 펜시를로버의 HPLC 신속분석법 개발 및 이를 이용한 생물학적동등성시험)

  • Kim, Jin Hee;Park, Ah Yeon;Jung, Eun Ha;Lee, Cheol Woo;Lee, Tae Ho;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.323-330
    • /
    • 2007
  • A simple and rapid HPLC method with fluorescence detection(FLD) for quantitation of penciclovir in human plasma using a monolithic column was developed and validated. Penciclovir and ganciclovir(internal standard, I.S.) were separated on a Chromolith column RP-18e ($4.6{\times}100mm$) with a mobile phase consisting of a mixture of (A) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (3/97, pH 2.5) and (B) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (50/50, pH 2.5) at a flow gradient of $1.6{\sim}4.0mL/min$. The retention times of penciclovir and internal standard were less than 4.0 min. Calibration curve was linear ($R^2=0.9994$) over a concentration range of $0.1{\sim}5{\mu}g/mL$. Intra-day precision, accuracy and inter-day precision were 1.36~8.55 %, 92.8~100.0 % and 0.93~5.62 %, respectively with a limit of quantitation at $0.1{\mu}g/mL$. The present HPLC-FLD method is sensitive, precise and accurate. The method described herein has been successfully used for the bioequivalence study of a famciclovir formulation product after oral administration to healthy Korean volunteers.