• 제목/요약/키워드: 직렬흐름

검색결과 48건 처리시간 0.037초

낮은 속도비에서의 직렬 이중 제트-교차흐름의 유동 구조 (The Flow Field Structures of In-lined Double Jet-in-Cross Flow at Low Velocity Ratio)

  • 이기영
    • 한국군사과학기술학회지
    • /
    • 제18권4호
    • /
    • pp.415-422
    • /
    • 2015
  • The flow field structures of dual jet-in-cross-flow were examined experimentally for in-lined perforated damage holes configuration using particle image velocimetry. Ensemble averaged in-plane velocity and vorticity data in the jet were determined to study the mean jet structure. Jets are formed by pressure differences between upper and lower airfoil surface. The flow structure of vicinity of the thru holes consist of a vortical structure that wrap around the jets like a horseshoe and develop further downstream through a pair of stream-wise vortices. The shape, size and location of the horseshoe vortex were found to be dependent on the angle of attack. In spite of the existence of battle damage holes, the effect on the control force was insignificant when the damage size was not large enough.

직렬연결 수직 및 수평 흐름 갈대 제올라이트 인공습지에 의한 생활하수 처리 (Evaluation of Combined Vertical and Horizontal Flow Zeolite-Filled Reed Bed with Intermittent Feeding for Sewage Treatment)

  • 서정윤
    • 한국습지학회지
    • /
    • 제16권1호
    • /
    • pp.51-59
    • /
    • 2014
  • 본 연구의 목적은 직렬연결 수직 및 수평 흐름 갈대 제올라이트 인공습지에 생활하수를 간헐적으로 주입하였을 때 처리효율을 조사하는 것이다. 각 항목별 유입수에 대한 평균 처리효율은 수직 흐름 인공습지 유출수에서 BOD 92.42%, $COD_{Cr}$ 79.02%, $COD_{Mn}$ 80.62%, SS 98.33%, T-N 37.06%, $NH{_4}^+-N$ 99.45%, T-P 57.96%이었으며 수평 흐름 인공습지 유출수에서 BOD 95.56%, $COD_{Cr}$ 91.02%, $COD_{Mn}$ 87.78%, SS 99.22%, T-N 45.87%, $NH{_4}^+-N$ 99.88%, T-P 71.17%이었다. 최종 유출수 중 T-N은 대부분이 $NO{_3}^--N$이었으며 $NO{_2}^--N$은 평균 0.04mg/L 이하이었다. 특히, 갈대 제올라이트 인공습지는 SS와 $NH{_4}^+-N$의 처리에 탁월하였다.

양방향 지능형 반도체 변압기의 조류제어와 입력전압 Sag 보상 특성분석 (Power flow control and Input voltage Sag compensation Analysis of Bidirectional Intelligent Semiconductor Transformer)

  • 김도현;이병권;한병문;이준영;윤영두;최남섭
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.345-346
    • /
    • 2013
  • 본 논문에서는 단상 1.9kV/127V, 2kVA 용량의 양방향 지능형 반도체 변압기의 시작품을 제작하고 그 동작특성을 실험적으로 분석한 내용을 기술하고 있다. 제작한 반도체 변압기는 3대의 LLC 컨버터를 입력 측은 직렬로 결합하고 출력 측은 병렬로 결합한 AC-DC 컨버터와 1대의 하드스위칭 양방향 2-Stage DC-AC 컨버터가 직렬로 결합되어 있다. 제안하는 반도체변압기의 회로적인 특성을 분석하기 위해 PSCAD/EMTDC 소프트웨어를 이용한 시뮬레이션을 실시하였고 분석을 통해 얻은 결과를 바탕으로 하드웨어 시작품을 제작하고 다양한 실험을 통해 그 동작과 성능을 검증하였다. 먼저 1차적으로는 정상동작에 대해 실험을 실시하고 얻은 결과를 시뮬레이션 결과와 비교 분석하였다. 2차적으로는 전력의 흐름에 따른 동작을 실험적으로 분석하였다. 그 후에는 입력전압에 외란이 발생하였을 때 보상성능을 순방향 조류와 역방향 조류 2가지 경우로 나누어 실험을 실시하고 그 결과를 실험결과와 비교 분석하였다. 분석한 결과 제안하는 반도체변압기는 양방향 전력흐름이 가능하고 입력전압에 Sag가 발생한 경우에도 이를 보상하여 수전단이나 부하에 전력공급이 가능함을 알 수 있었다. 향후 단상 반도체 변압기 2대를 더 제작하여 3상 3.3kV/380V, 6kVA 용량으로 확대하여 실험을 실시할 예정이다.

  • PDF

PIV를 이용한 다양한 배열에서 2원주 주위의 유동장 특성 연구 (The Characteristic Investigation of the Flowfield around Two Circular Cylinders in Various Arrangements Using the PIV)

  • 노기덕;김광석
    • 한국항공우주학회지
    • /
    • 제36권2호
    • /
    • pp.131-136
    • /
    • 2008
  • 본 연구는 다양한 배열 상태에 놓인 2원주 주위의 유동장 특성을 PIV를 이용하여 파악한 것이다. 직렬배열에서 하류측 원주의 후방에서 측정한 Strouhal 수는 수평 간격비가 클수록 작게 나타났다. 직렬배열에서 2원주 사이의 흐름은 거의 정체되어 있으며, 상류측 원주에 가까울수록 정체 범위가 크게 나타났다. 직렬배열에서 자유류와 2원주의 중심선이 이루는 받음각()의 미소 변화(${\alpha}$=${\pm}1.0^{\circ}$)에 따라 2원주 사이에는 서로 반대 방향의 와류가 생성되었다. 병렬배열에서 수직 간격비가 클수록 2원주 사이의 유속이 크게 나타났다.

염소 접촉조 직렬 연결시 수리흐름 특성에 관한 연구 (Case study on Hydraulic characteristics within Chlorine Contactors in Series)

  • 강태훈;채선하;김성수;왕창근
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.497-502
    • /
    • 2011
  • In order to examine the effects of combination of plug flow reactors in series on hydraulic characteristics, comparative tracer tests were conducted for the cases of the existing clear well and clear wells combined in series. From the results of tests, $T_{10}$/T within existing clear well was 0.62~0.68 depending on inlet flowrate, and that in the case of combination in series was 0.69~0.78. While it would be minor improvement in contact efficiency, it would be appropriate to combine two clearwell with pipe in series for expansion.

직렬통신과 Visual Basic을 이용한 Home Automation System (Home Automation System Using Serial Communication and Visual Basic)

  • 지준근;이광수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2463-2465
    • /
    • 2002
  • 본 논문에서는 Home Automation을 위한 하드웨어와 제어용 프로그램의 개발에 목적을 두었다. Home Automation에 쓰인 하드웨어 부분에서는 8051 마이크로 컨트롤러를 사용했다. 본 논문에서 가장 중요한 부분은 플랜트끼리의 통신 알고리즘이며, 일반 가정용 IBM PC의 USB 포트를 이용한 화상 전달방법이다. 화상 전달에 필요한 DLL부분은 C++로 제작되었으며 전체적인 제어용 프로그램은 비주얼툴인 Visual Basic으로 제작하였다. 하드웨어는 각각의 플랜트에 따라 각각의 구동부가 있으며 몇몇 구동부에는 다중 통신을 위한 8051 마이크로 프로세서가 있다. 이 모든 장치의 데이터 흐름을 알 수 있도록 PC를 통해 디스플레이하며 PC와 직렬 통신을 통해 이 모든 것이 이루어진다.

  • PDF

흡수식 냉동기 고효율화를 위한 사이클 설계 (The study of High Efficiency Cycle Characteristics of the absorption Chiller)

  • 박찬우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.534-539
    • /
    • 2007
  • The objectives of the present work is to investigate the influence of the solution cooled absorber(SCA), refrigerant drain heat exchanger(RSX), exhaust gas/solution heat exchanger(ESX) and high efficiency solution heat exchanger on COP for a double-effect series-flow absorption chiller. A simulation program has been prepared for the cycle analysis of absorption chillers. As a result, Solution heat exchangers(LSX, HSX) are a most effective element for the COP than the others. In spite of the poor contribution to COP, SCA make a rule to reduce the crystallization phenomena of LiBr solution at solution heat exchanger. And the optimum solution split ratio are varied with the relative size of RSX and LSX.

  • PDF

흡수식 냉동기 고효율화를 위한 사이클 설계 (The Study on High Efficiency Cycle Characteristics of the Absorption Chiller)

  • 박찬우
    • 설비공학논문집
    • /
    • 제20권10호
    • /
    • pp.662-668
    • /
    • 2008
  • The objectives of the present work are to investigate the influence of the solution cooled absorber(SCA), refrigerant drain heat exchanger(RSX), exhaust gas/solution heat exchanger(ESX) and high efficiency solution heat exchanger on COP for a double-effect series-flow absorption chiller. A simulation program has been prepared for the cycle analysis of absorption chillers. As a result, solution heat exchangers(LSX, HSX) are the most effective element for the COP than the others. In spite of the poor contribution to COP, SCA plays an important role to reduce the crystallization phenomena of LiBr solution at solution heat exchanger. And the optimum solution split ratio varies with the relative size of RSX and LSX.