Numerical Study on the Smoke Movement and Evacuation in the Deeply Underground Subway Station Fire (대심도 지하역사에서의 화재시 연기거동과 피난에 대한 수치해석 연구)

  • Kim, Hong-Jin;Bae, Sung-Yong;Choi, Young-Ki;Hong, Gi-Bae;Ryou, Hong-Sun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1342-1347
    • /
    • 2011
  • Advantages of the deeply underground subway are underground space efficiency, high speed, decrease of noise and vibration. However, when fire occurs in the deeply underground subway station, large casualties are occurred like Daegu subway station fire due to the increase of evacuation distance. In this study, a numerical analysis was performed by using the fire and evacuation analysis program FDS+EVAC for smoke movement and evacuation in Beotigogae station among the deeply underground subway station. Heat release rate of carriage fire was set 10MW and the fire growth rate was ultrafast. As a result, the smoke move to the exit at 1085 second. The total evacuation time took 956 second.

  • PDF

Development of a Duct Cleaning Robot and Technology Trends for Subway Stations (지하역사 덕트 청소로봇 기술동향 및 개발)

  • Jeong, Woo-Tae;Park, Duck-Shin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1335-1341
    • /
    • 2011
  • Conserving clean air and removing contaminants and particular matters accumulated in the ventilation system of the subway stations are key issue for green railway environment. There is no national guideline or industrial regulations to sustain clean duct and ventilation system, which requires rapid reformation of cleaning procedure and system. In fact, accumulated various particular matters and dusts can occur secondary air contamination and become a primary health harm factor for subway passengers. This study investigates various duct cleaning technologies and trends. In additon, effective cleaning method with an automated robot device is proposed. In particular, current dust cleaning technologies and duct cleaning robots are analyzed based on their functions and feasibilities. The proposed design of automated device is expected to save the operating cost of subway HVAC system and sustain clean air environment.

  • PDF

Design of intelligent fire detection / emergency based on wireless sensor network (무선 센서 네트워크 기반 기능형 화재 감지/경고 시스템 설계)

  • Yuk, Ui-Su;Kim, Seong-Ho
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.04a
    • /
    • pp.367-371
    • /
    • 2007
  • 최근 여러 지역에서 발생되는 지하철 참사 및 대형화재 또는 지하철 역사, 대형 지하상가, 백화점, 지하공간, 대형쇼핑센터, 숙박업소, 공공건물등 대형 다중이용시설 등에서 발생될 수 있는 예측 불가능한 인재, 천재지변에 안전하게 대피하기 위한 수단으로 비상등 및 여러 감지기들이 소방법 개정으로 의무설치 하고 있다. 비상등 및 감지기들은 비상시 위험 감지 및 경고 전파를 위해 사용되는데 방음벽이나 격벽, 경고 거리의 제한으로 인해 경고 전달의 어려움이 있다. 본 논문에서는 무선 데이터 전송기능 및 경고등, 음성전파 기능을 갖는 무선 지능형 화재 감지/경고시스템을 설계하고자 한다.

  • PDF

Study on the Air Quality of Metropolitan Subway Stations (수도권 지하철 지하역사의 실내공기질 연구)

  • Cho Young-Min;Park Duckshin;Park Byung-Hyun;Park Eun-Young
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.77-82
    • /
    • 2005
  • Recently, people's rising interests toward a 'well-being' lifestyle together with research contributions are accelerating the concerns regarding indoor air pollution making indoor air quality management an emerging environmental challenge of the era. The Ministry of Environment began to regulate the air quality of railway stations last year. The newly established 'Indoor Air Quality Act' covers 17 facilities whereas only underground subway stations and underground markets were regulated by previous 'Underground Air Quality Management Act' of 1996. In this study, we carried out the measurement of temperature, relative humidity, CO(carbon monooxide), $CO_2$(carbon dioxide), HCHO(formaldehyde), PM-10(particulate matters), and VOCs(volatile organic compounds) in underground subway stations. Based on the obtained results, we will suggest a way to improve the indoor air quality of the subway stations.

  • PDF

Numerical Analysis on Passenger Flow for the Model of Multi-storied Subway Station (복층 구조의 지하역사 모델에 대한 여객 유동 해석)

  • Nam, Seong-Won;Kwon, Hyeok-Bin;Cha, Chang-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1475-1480
    • /
    • 2007
  • Numerical analysis has been conducted to simulate pedestrian flow in the model of two-storied subway station. Because almost all the subway stations are two or three storied structure, simulations are conducted for the passengers those who get off the train and pass the wicket. Passenger flow analysis is very important factor to design the station and also to manage the operation of subway system. In the subway station, pedestrians move to the horizontal directions as well as vertical ones. Therefore, to consider the movement of pedestrians is necessary for the guarantee of safety and conveniency. As the up and down floors are connected with step, escalator and elevator, the entire movements in the multi-storied station should be simulated as like a 3-dimensional flow. Numerical schemes for the directional sweeping are developed to prevent the dependency on physical structure of station and to determine primary direction and secondary one. By using the developed program, we compared the simulation results of the effects of the location and size of exit and elapsed time.

  • PDF

A study on panel structure filter performance of air handling units for subway stations (지하역사 공기조화기 장착용 판넬형 부직포필터 성능 연구)

  • Hwang, Sun-Ho;Bae, Sung-Joon;Shin, Chang-Hun;Park, Youn-Ho;Kwon, Soon-Bark;Kim, Se-Young
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1328-1334
    • /
    • 2010
  • As the life quality is higher and higher, the requirement for the clean air in a subway station is strongly being increased. Therefore, many researches have been performed about that. Seoulmetro has taken many parts and has applied latest products for the higher level of air quality. However, by various kinds of facilities, it is hard to maintain the facilities and verify their performances. Therefore it is better to use qualified air filter system by the performance test at subway stations than to apply newly developed one without any verification. This study is focused on the performance verification for a panel structure, which consists of non-woven fabric, to suggest the standard of air filter systems.

  • PDF

Numerical Study of Axial-flow Cyclone Cluster for Subway Station HVAC system (지하역사 공기조화기용 축류형 사이클론 클러스터의 수치해석적 성능 평가 연구)

  • Kim, Myeoung-Joon;Kim, Ho-Joong;Kim, Jin-Kwan;Kwon, Soon-Bark;Kim, Tae-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.757-761
    • /
    • 2009
  • Axial-flow cyclone separator cluster can be used for a dust removal device inside a heating, ventilation, and air conditioning(HVAC) system of subway station. In this study, 3-dimensional computational fluid dynamics(CFD) analysis was performed to compare single unit axial-flow cyclone with couple unit axial-flow cyclone cluster. It is shown that the performance of cyclone separator is not influenced by number of single units but influenced by ability of single unit.

  • PDF

The study for thermal environment improvement at subway station platform (Part 2: Thermal environment according to supply outdoor temperature) (지하역사 승강장 열환경 개선을 위한 연구 (제2보: 도입외기온도에 따른 승강장 열환경))

  • Kim, Hoe-Ryul;Kim, Dong-Gyu;Kum, Jong-Soo;Chung, Yong-Hyun;Kim, Jong-Ryel;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.561-564
    • /
    • 2009
  • This study is to examine the possibility of pre-cooling at platform. Through measurement of the thermal environment of Bujeon Subway platforms, review the potential use of ground-water and night purge. The results of this research can improve the thermal environment pre-cooling of the design.

  • PDF

A Study on the Efficiency of Smoke Barriers in the Subway Station (지하역사 제연경계벽의 제연 효용성에 관한 연구)

  • Kim, Bum-Kyu;Kim, Hee-Young;Lee, Sung-Mi;Park, Yong-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.204-208
    • /
    • 2008
  • Casualties Damage from Smoke is very serious consequence. Especially, Damage from smoke in in the Subway Station is the terrible result. Smoke from the fire in the Subway Station that evacuation route on the path and the sight of refugees caused by serious traffic problems. Accordingly, A study on Smoke barriers of smoke systems take into considerations relate to effects depending on wind velocity speed of the piston effect come into the retarding effect of smoke control in smoke barriers. As a result of modeling, According to increasing of Velocity in the platform which installed smoke barriers were been on the increase spreading quantity of smoke in the right direction of upstairs however, In contrast spreading quantity of smoke in the left direction on the upstairs were been on the decrease.

  • PDF

A preliminary study of Standardization Plan on Underground Air filtration Facility (지하역사 공기여과장치 표준화방안 사전연구)

  • Bae, Sung-Joon;Hwang, Sun-Ho;Shin, Chang-Hun
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.919-929
    • /
    • 2009
  • 2008, Seoulmetro transports an average of 3,952,000 passengers every day with a 0.8% increase of the daily ridership compared to last year.(Korean Economics '09.01.21) Seoul subway systems ridden by a considerable number of Seoul citizens place their top priority on swiftness, safety and clean underground air quality so as to meet the customer satisfaction. One of the most important problems is to eliminate minute dust(PM10) among the pollutants such as the gas attributable to air pollution and floating particulate matter defined by the ordinance of the Ministry of Environment. Seoulmetro install and operate many kinds of air filtration facilities, however we've launched a research on "Standardization Plan on Underground Air Filtration Facility" for the installation and improvement of optimum standardized air filtration system. As a preliminary study, we're going to consider ventilation system and air filter to supply filtered metropolitan outdoor air aimed at ensuring clean underground environment.