• Title/Summary/Keyword: 지하수 모니터링

Search Result 252, Processing Time 0.029 seconds

Water-well Management Data Modeling using UML 2.0 based in u-GIS Environment (u-GIS 환경에서 UML 2.0을 활용한 지하수 관리 데이터 모델링)

  • Jung, Se-Hoon;Kim, Kyung-Jong;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.4
    • /
    • pp.523-531
    • /
    • 2011
  • Many of the wells which were constructed to use ground water resource are abandoned and not managed efficiently after its use. And a variety of heavy metals and organic compounds are released from the abandoned wells and this can cause ground water pollution. Therefore in this paper implemented to monitor locational information drill holes and underground water sensing information on real time basis using u-GIS environment to combined ubiquitous sensor node and GIS technology to improve these problems. In addition, this system suggests using system by UML 2.0 by analyzing variety requirement of user and between system internal modules interaction and data flow. It provides graphical user interfaces (GUI) to system users to monitor water-well related property information and its managements for each water-well at remote site by variety platform by GIS map and web environment and mobile device based on smart phone.

용인시 백암정수장 지역 지하수의 지화학적 특성

  • 김건영;김천수;배대석;강재기;김형수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.597-600
    • /
    • 2003
  • 용인시 백암취수장 주변 지역의 지하수에 대해 기초적인 지화학적 조사를 수행하였다. 현장측정자료에서는 취수정의 pH와 EC값이 주변지하수보다 지표수와 유사한 값을 보이며, 취수정의 용존산소(DO) 함량이 천층지하수보다 높은 값을 보인다. 더구나 취수정의 경우 NO$_3$함량이 10.5-12.1 mg/L이며 주변 지하수는 7.2-25.3 mg/L, 지표수는 13.1-14.9 mg/L로서 취수정의 설치심도가 70-180m로서 상대적으로 깊은 암반층에 설치되어 있다 하더라도 주변지하수 및 인접 지표수의 혼입에 의해 영향을 받아 오염이 진행되고 있음을 알 수 있다. 이와 같이 연구 지역은 현재 취수정이 모두 청미천변에 위치하고 있어서, 현재 암반 지하수로 개발하고 있는 취수정 지하수가 주변 천부지하수 및 지표수에 의한 혼입 및 오염가능성이 높기 때문에, 앞으로 장기적인 모니터링 및 지화학적 연구가 지속적으로 이루어 져야 할 것으로 사료된다.

  • PDF

The Development of Multi-channel Electrical Conductivity Monitoring System and its Application in the Coastal Aquifer (다채널 전기전도도 모니터링 시스템의 개발과 연안지역 공내수 모니터링에 대한 적용 사례)

  • Shin, Je-Hyun;Hwang, Se-Ho;Park, Kwon-Gyu;Park, Yun-Seong;Byun, Joong-Moo
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.2
    • /
    • pp.156-162
    • /
    • 2005
  • Particularly in research related to seawater intrusion the change of fluid electrical conductivity is one of major concerns, and effective monitoring can help to optimize a water pumping performance in coastal areas. Special considerations should be given to the mounting of sensors at proper depth during the monitoring design since the vertical distribution of fluid electrical conductivity is sensitive to the characteristics of seawater intrusion zone. This tells us the multi-channel electrical conductivity monitoring is of paramount consequence. It, however, is a rare event when this approach becomes routinely available in that commonly used commercial stand-alone type sensors are very expensive and inadequate for a long term monitoring of electrical conductivity or water level due to their restricted storage and difficulty of real-time control. For this reason, we have developed a real-time monitoring system that could meet these requirements. This system is user friendly, cost-effective, and easy to control measurement parameters - sampling interval, acquisition range, and others. And this devised system has been utilized for the electrical conductivity monitoring in boreholes, Yeonggwang-gun, Korea. Monitoring has been consecutively executed for 24 hours, and the responses of electrical conductivity at some channels have been regularly increased or decreased while pumping up water. It, with well logging data implemented before/after pumping water, verifies that electrical conductivity changes in the specified depths originate from fluid movements through sand layer or permeable fractured rock. Eventually, the multi-channel electrical conductivity monitoring system makes an effective key to secure groundwater resources in coastal areas.

IoT based Urban Underground Utility Monitoring and Management System (사물인터넷(IoT) 기반 도시 지하매설물 모니터링 및 관리시스템 기술)

  • Jun, J.A.;Lee, J.H.;Chin, C.H.;Choi, C.H.;Lee, S.J.;Yum, B.W.;Lee, I.H.
    • Electronics and Telecommunications Trends
    • /
    • v.30 no.5
    • /
    • pp.28-38
    • /
    • 2015
  • 최근 빈번히 발생하고 있는 도심지 내 지반침하의 주된 원인은 지하공간의 난개발, 상하수도 시설의 노후화, 이로 인한 급격한 지하 수위의 변화에 기인한다고 알려져 있으며 이에 대한 실시간 모니터링 및 종합적인 상관성 분석을 통한 사고예방이 시급한 실정이다. 지하공간의 특수성으로 인해 광역 지하공간 정보를 실시간으로 수집하여 모니터링할 수 있는 기술이 부재한 점과 이로 인한 지하공간의 위험도 분석과 과학적 재난대응 시스템 구축에 어려움이 존재한다. 본고에서는 도시 지하공간 내 지하매설물(상하수도)의 상태와 지하공간상황(도시철도구조물, 지하수, 지반변형)을 실시간으로 모니터링하기 위한 도메인별 기술개발 동향에 대해서 정리하고, 수집된 정보의 종합적 분석을 통한 지하공간의 이상 징후를 사전감지, 예측, 대응하기 위해 도전하고 있는 기술적 이슈들을 살펴보고자 한다.

  • PDF

Variation in Nitrate Contamination of Shallow Groundwater in a Farmland in Gyeonggi-do, Korea (경기도 지역 농경지의 천부 지하수 내 질산염 오염특성과 변화)

  • Lee, Eun-Jae;Woo, Nam-Chil;Lee, Byung-Sun;Kim, Yang-Bin
    • Economic and Environmental Geology
    • /
    • v.41 no.4
    • /
    • pp.393-403
    • /
    • 2008
  • Hydrogeochemistry of groundwater was studied in order to identify the influence of cow manure, distributed to a farmland as organic fertilizer, on nitrate concentrations in shallow groundwater and its spatio-temporal variations. From monitoring wells, water levels were measured using automatic data loggers, and water samples collected and analyzed in Feb., April, June and Oct. 2007. The average electric conductivity and concentration of nitrate in the groundwater show the highest levels in April and decline in subsequent sampling times. Decreases in dissolved oxygen(DO) and nitrate concentrations from April to Oct. and corresponding increases in $HCO_3$ concentrations indicate denitrification processes by microorganisms. Spatial variation of nitrate concentration appeared to be affected by the redox conditions of groundwater controlled by geochemical reactions of Mn, Fe and DOC contents.

방사성폐기물 처분연구를 위한 심부 시추공지하수의 지화학특성

  • 배대석;고용권;김건영;김천수;김경수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.335-338
    • /
    • 2002
  • 방사성폐기물처분연구의 일환으로 화강암지역내 심부지하수에 대한 지화학특성조사가 수행되었다. 지하수 시료는 다중패커시스템이 설치된 심부시추공으로부터 심도별로 채취되었으며, 계속적인 지화학 및 동위원소에 대한 모니터링이 진행되고 있다. 심부지하수는 pH가 약10.0이며 Na-HCO$_3$형으로 지화학적으로 특징되며, 지표로 250m이하의 심도에서는 거의 동일한 지화학적 특성을 보인다. 동위원소결과는 심부지하수는 천수기원임을 보이며, 천부지하수에 비해 약500~1,000m 높은 고도에서 함양되었음을 보여준다. 250m이하의 심부지하수는 50년이상의 체류시간을 갖음을 나타낸다.

  • PDF

하천수 열원을 이용한 개발 가능한 에너지량 산정

  • An Yeong-Seop;Kim Jin-Hun;Jeong U-Seong;Kim Hyeong-Su
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.365-368
    • /
    • 2006
  • 전 세계적으로 에너지 소비가 계속적으로 증가함에 따라 화석 에너지를 대체하기 위한 다양한 기술개발이 이루어지고 있으며, 지열 및 수온차 에너지 개발도 대체 에너지의 하나로 주목받고 있다. 본 연구에서는 이러한 지열 및 수온차 에너지의 개발 가능 에너지량을 산정하기 위하여 장기간에 걸쳐 하천수 및 충적층 온도 모니터링을 수행하고 이를 바탕으로 개발 가능 에너지량을 산정하였다. 모니터링 결과 충적층이나 하상에서의 온도변화가 대기 온도에 비하여 작음을 확인하였으며, 또한 충적층의 온도 변화가 하천수보다는 온도변화 폭이 작게 나타났다. 향후 이러한 수온차를 이용한 냉난방용 열펌프시스템을 활용하여 친환경적이고도 경제적인 에너지를 확보할 수 있을 것으로 기대된다.

  • PDF

Hydrologic Characterization through Ground Water Monitoring in a Coastal Aquifer (해안 대수층에서 지하수 장기 모니터링을 통한 수리 특성 조사)

  • Shim, Byoung-Ohan;Lee, Chol-Woo
    • Economic and Environmental Geology
    • /
    • v.44 no.3
    • /
    • pp.239-246
    • /
    • 2011
  • Groundwater in small islands is used as main water resource but the overuse of groundwater may cause seawater intrusion and temperature decrease in geothermal wells. This study aimed to characterize the hydrogeology of Maeum-ri area in Seokmo Island of Ganghwagun using long-term monitoring at groundwater wells and geothermal wells. In the monitoring period seasonal water level change, consistent drop or increase of water levels are not detected. The groundwater temperature about 10m below ground surface shows year cycle variation having two to five months difference with ambient temperature cycle. The storativity was calculated by tidal method. The storativity estimated by adapting tidal efficiency factor showed some larger values than that by using tidal time lag. The result suggested that the tidal method assuming several assumptions on aquifer condition may produce broad ranges but the calculated ranges at this application are reasonable. The similar shape of groundwater level change and tidal effects was observed at several wells clustered east-south-east direction which may implicate the distribution of vertical fracture system strongly related with groundwater flow channels. The applied methodology and study results will bc valuable to evaluate optimal pumping rate for the preservation of groundwater resources, and to manage geothermal development.

인공구조물에 의해 유도되는 지하수-하천수 시스템의 상호작용에 대한 예비 연구

  • O Jun-Ho;Seong Hyeon-Jeong;Kim Tae-Hui;Kim Yong-Je;Song Mu-Yeong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.408-411
    • /
    • 2005
  • 현재 국내에서는 지하수 순환 특성에 대한 연구가 미약하며 그에 대한 연구가 요구 되고 있다. 본 연구에서는 지하수 순환을 중심으로 인공구조물에 의해 유도되는 지하수-하천수 시스템의 상호작용에 대하여 하천수의 수위/유량 변화와 주요 이온 변화에 따른 지하수의 변화를 모니터링을 통해 검토해 보았다. 연구결과 혼합대에 설치된 관측정에서 나타난 수위 및 주요 이온 변화에서 하천의 영향으로 인한 변화 패턴을 확인할 수 있었다. 추후 관측 자료가 누적되고 강수량, 하천수위, 지하수위, 지하수질, 하천수질 등에 대한 상호 상관성을 검토한다면 더 명확한 결과를 얻을 수 있을 것으로 본다.

  • PDF

Monitoring of Soil Pollutant Loadings in Greenhouse and Conventional Farming Practices (시설재배지와 관행재배 지역의 토양 내 오염부하 모니터링)

  • Hong, Eun-Mi;Choi, Jin-Yong;Yoo, Seung-Hwan;Kang, Moon-Seong;Jang, Jeong-Ryeol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.448-448
    • /
    • 2012
  • 농경지의 잔류비료나 농약 등의 비점오염원은 강수 또는 관개를 함에 따라 지표 및 지하 유출과 함께 거동함으로써 토양 내에 집적됨과 동시에 지하수 수질에도 영향을 미칠 수 있다. 특히, 최근 고부가가치 농산물 수요의 증가로 전국적으로 확대되고 있는 시설재배의 경우 노지재배와는 상이한 유출 및 침투 특성을 가지고 있음과 동시에 과다시비로 인한 오염원의 토양 내 집적이 심각한 수준이나, 이에 대한 연구가 미흡한 실정이다. 따라서 본 연구에서는 시설재배지와 관행재배 지역의 토양 내 비점오염원 오염부하량을 평가하고 지하침투 과정을 평가하기 위하여 시설재배지와 관행재배지의 비교 평가가 가능한 포장 및 광역단위 시험포장을 연구대상지역으로 선정하였다. 모니터링 대상지역에서 토양수, 토양수분, 관개량, 기상조건 등을 측정하기 위한 장비를 설치하여 비점 모니터링 시스템을 구축하였고, 한달에 두 번 모니터링을 통하여 자료 수집 체계를 확립하였다. 시설재배지 및 관행재배지 토양 및 토양수 수질 분석 결과, 시설재배지 내 영양물질 농도가 관행재배지와 비교하여 전반적으로 높았으며, 특히, 하부토층으로 내려갈수록 영양물질의 농도 및 편차가 크게 나타났다. 향후 본 시험포장에서의 지속적인 모니터링 및 샘플링을 통하여 시설재배지 토양내 비점오염원의 침투 과정을 분석할 수 있을 것으로 판단되며, 지하침투 영향 및 오염부하량 모델링 기초자료로 활용될 수 있을 것으로 판단된다.

  • PDF