• Title/Summary/Keyword: 지하수위 변화

Search Result 456, Processing Time 0.035 seconds

Analysis on the Hydrologic Behavior of Heavy Snowfall in East Coast Region (동해안 지역 폭설의 수문학적 거동 분석)

  • Kim, Nam-Won;Chung, Il-Moon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.257-262
    • /
    • 2019
  • In order to investigate hydrological behavior of the east coast snowfall in February 2014, this study analyzed the changes of the hydrological components due to the snowmelt in the Ssangcheon watershed nearby Sokcho city. The temporal changes of hydrological components through snowfall and snowmelt processes were simulated using SWAT-MODFLOW. As a result of the analysis, snow accumulated until February is fully melted from the late March, 2014, and the stream discharge of April is more than doubled compared to the case of not considering snowmelt. The soil moisture also increased by up to 21 % due to the melting and the groundwater level rose by about 40 cm until the end of April. Thus, the heavy snowfall in February 2014 is considered to play an important role in securing water resources in this region.

Analysis of hydrological components according to low impact development practices (저영향개발 기법 적용에 따른 수문요소 영향 분석)

  • Lee, Hyunji;Kang, Moon Seong;Kim, Hakkwan;Kim, Kyeung;Kim, Ji Hye
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.321-321
    • /
    • 2020
  • 도시화로 인해 유역의 불투수면적이 증가함에 따라 수문학적 요소와 수질에 큰 변화를 가져왔다. 불투수면적의 증가는 강우시 지표유출의 증가, 토양층 침투 차단으로 인한 지하수 재충전 감소 및 지하수위 감소를 초래하여 결과적으로 기저유출을 감소시킨다. 이러한 증가된 불투수면적이 강우유출수의 수문 및 수질에 미치는 영향을 완화하기 위해 최근 저영향개발 (Low Impact Development; LID) 기법이 개발되어 적용되고 있다. LID 기법은 개발 이전의 수문순환 상태에 최대한 근사하도록 개발하는 기법으로 우수 유출 속도 감소, 유역에서의 저류, 침투 및 증발산 과정 촉진, 하류로의 오염물질을 저감시킨다. 효과적인 저영향개발 기법 적용을 위해서는 시설 설치 전 모형을 이용한 저영향개발 기법의 적용 효과를 파악해야 한다. 이에 따라 많은 저영향개발 기법 모형들이 개발되었으며, 그 중 SWMM (Storm Water Management Model) 모형이 LID 효과분석을 위해 많이 이용되고 있다. 그러나 SWMM 모형의 경우, 저영향개발 기법으로 모의되는 침투 후 토양 물 흐름이 토양의 수분 조건을 고려하지 않고 모의가 되고 있다. 본 연구에서는 HSPF(Hydrological Simulation Program: FORTRAN) 모형을 이용하여 LID 시설 내에서의 저류현상을 구현하고 수문요소에 대한 영향을 분석하고자 한다. HSPF 모형의 입력자료를 구축하여 모형을 구축하고 LID 모형 적용 전에 모형의 보정 및 검정을 수행하였으며, LID 시설을 적용하여 유역내 수문요소들의 변화를 분석하였다. 본 연구의 결과는 향후 LID 효과 분석을 위한 기초자료로 활용될 수 있을 것으로 사료된다.

  • PDF

Monitoring of Groundwater quality according to groundwater use for agriculture (농업용 지하수 사용에 따른 지하수질 모니터링 평가)

  • Ha, Kyoochul;Ko, Kyung-Seok;Lee, Eunhee;Kim, Sunghyun;Park, Changhui;Kim, Gyoo-Bum
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.30-30
    • /
    • 2020
  • 본 연구에서는 여름철에 농업용수(벼농사용)로서 집중적으로 지하수를 사용하는 지역에서 시기별 지하수 사용에 따른 지하수 수질변화를 평가하기 위해 수행되었다. 연구지역은 충남 홍성군 양곡리와 신곡리 일부를 포함하는 면적 2.83 ㎢(283.3 ha)에 해당하는 지역이다. 연구지역 지하수 수질의 공간적 분포 및 시간적 변화 특성 평가를 위하여 2019년 2회(7월, 10월)에 걸쳐 지하수 관정(21개소)에 대하여 조사 및 분석을 수행하였다. 지하수 샘플은 현장에서 온도(T), pH, 용존산소(DO) 및 전기전도도(EC), 산화환원전위(Eh) 등을 측정하였고, 실험실에서 주요 양이온 및 미량원소(Ca, Mg, Na, K, Si, Sr), 음이온(F, Cl, Br, NO2, NO3, PO4, SO4), 알칼리도, 용존 유기탄소(DOC)와 용존 유기물(DOM) 등을 분석하였다. 지하수 수질조사 결과, 전체의 14~15개소(67~71%)가 Ca-HCO3 유형으로 분류되었으며, 다음으로는 Ca-Cl 유형이 4~5개소(19~24%)가 관찰되었다. 얕은 심도의 관정에서 상대적으로 심도가 깊은 관정보다 대부분 성분(TDS, Ca, Mg, Na, K, Cl, SO4, HCO3, DOC)에서 높은 농도를 나타내었다. 지하수의 수질자료를 이용하여 다변량통계분석법인 주성분분석(PCA: Principal Components Analysis)과 계층적 군집분석(HCA: Hierachical Cluster Anlaysis)를 수행한 결과, 초기 3개 주요 고유성분(eigenvalue)는 PC1 54.0%, PC2 14.2%, PC3 12.3%로 전체 분산의 88.3%를 설명할 수 있었다. PC1은 Ca, Mg, Na, K, Cl, SO4, DOC가 주요한 영향 인자였으며 PC2는 HCO3, NO3, DO에 영향 받음을 확인하였다. 계층적 군집분석 결과, 연구지역 지하수는 Na-Cl 유형의 C-3 관정을 제외하고는 크게 두 그룹으로 구분되어 졌다. 다변량통계분석의 결과에서도 수리지화학, 동위원소, 용존유기물 등의 특성에서 나타나는 것과 유사한 연구지역의 수질특성을 확인할 수 있었다. 연구지역은 차시기 동안 수질변화는 일부 관정을 제외하고는 유의할 만한 수준으로 관찰되지는 않았고, 지하수 사용에 따른 지하수위 회복도 빠르게 진행되고 있는 것으로 나타났다.

  • PDF

Seasonal Variation of Cr(VI)-contaminated Groundwater Quality and the Potential for Natural Attenuation (6가 크롬 오염 지하수 수질의 계절변화와 자연저감 가능성)

  • Chon, Chul-Min;Ahn, Joo-Sung;Roh, Yul;Rhee, Sung-Keun;Seo, Hyun-Hee;Kim, Gue-Young;Koh, Dong-Chan;Son, Young-Chul;Kim, Ji-Wook
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.645-655
    • /
    • 2008
  • The Cr(VI) concentrations at the shallow aquifer well (MPH-0-1) of the Moonpyung groundwater monitoring station were in the range of 0.5 to 3.1 mg/L exceeding 10 to 62 times the guideline for drinking-water quality, indicating continuous contamination. However, Cr was not detected at the deep bedrock well and the other subsidiary monitoring wells except for MPH-1 and 6. Cross-correlation analyses were conducted for rainfall and groundwater level time series, resulting in the mean time of recharge after precipitation events to be 5.6 days. For rainy season, the water level was raised and the Cr(VI) concentration was several times lower than that during dry season at well MPH-0-1 well. Correlation of the Cr(VI) concentration with the groundwater-level showed that the Cr(VI) reduction was closely related with the groundwater-level rise in the well. However, the groundwater level rise during high water season induced the lateral migration of the Cr(VI)-contaminated groundwater at well MPH-4. We enriched and isolated a chromium reducing bacteria, Enterobacter aerogenes, from the Cr(VI)-contaminated groundwater in the wells MPH-0-1 and MPH-1. The bacteria may play an important role for immobilizing Cr(VI) in the Cr(VI)-contaminated groundwater. Therefore, the migration of the contaminant (Cr(VI) must has been restricted because of the natural attenuation by microbial reduction of Cr(VI) in the groundwater. This research suggests that the bioremediation of the Cr(VI)-contaminated groundwater by the indigenous bacteria may be feasible in the Cr(VI) contaminated groundwater.

Application of Geophysical Methods to Detection of a Preferred Groundwater Flow Channel at a Pyrite Tailings Dam (황철석 광산 광미댐에서의 지하수흐름 경로탐지를 위한 물리탐사 적용)

  • Hwang, Hak Soo
    • Economic and Environmental Geology
    • /
    • v.30 no.2
    • /
    • pp.137-142
    • /
    • 1997
  • At the tailings dam of the disused Brukunga pyrite mine in South Australia, reaction of groundwater with the tailings causes the formation and discharge of sulphuric acid. There is a need to improve remediation efforts by decreasing groundwater flow through the tailings dam. Geophysical methods have been investigated to determine whether they can be used to characterise variations in depth to watertable and map preferred groundwater flow paths. Three methods were used: transient electromagnetic (TEM) soundings, direct current (DC) soundings and profiling, and self potential (SP) profiling. The profiling methods were used to map the areal extent of a given response, while soundings was used to determine the variation in response with depth. The results of the geophysical surveys show that the voltages measured with SP profiling are small and it is hard to determine any preferred channels of groundwater flow from SP data alone. Results obtained from TEM and DC soundings, show that the DC method is useful for determining layer boundaries at shallow depths (less than about 10 m), while the TEM method can resolve deeper structures. Joint use of TEM and DC data gives a more complete and accurate geoelectric section. The TEM and DC measurements have enabled accurate determination of depth to groundwater. For soundings centred at piezometers, this depth is consistent with the measured watertable level in the corresponding piezometer. A map of the watertable level produced from all the TEM and DC soundings at the site shows that the shallowest level is at a depth of about 1 m, and occurs at the southeast of the site, while the deepest watertable level (about 17 m) occurs at the northwest part of the site. The results indicate that a possible source of groundwater occurs at the southeast area of the dam, and the aquifer thickness varies between 6 and 13 m. A map of the variation of resistivity of the aquifer has also been produced from the TEM and DC data. This map shows that the least resistive (i.e., most conductive) section of the aquifer occurs in the northeast of the site, while the most resistive part of the aquifer occurs in the southeast. These results are interpreted to indicate a source of fresh (resistive) groundwater in the southeast of the site, with a possible further source of conductive groundwater in the northeast.

  • PDF

Stress Day Index to Predict Soybean Yield Response by Subsurface Drainage in Poorly Drained Sloping Paddy Fields (배수불량 경사지 논에서 배수개선에 따른 콩의 수분스트레스 반응해석)

  • Jung, Ki-Yuol;Yun, Eul-Soo;Park, Chang-Young;Hwang, Jae-Bok;Choi, Young-Dae;Park, Ki-Do
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.702-708
    • /
    • 2011
  • There are considerable areas of wet paddy fields in Korea that requires improvement of its drainage system. In poorly drained sloping paddy fields, upland crops can be damaged by either rainfall or capillary rise of the water table caused by percolating water beneath the upper fields during summertime rainy season. The purpose of this study is to evaluate excess water stress of soybean yield by drainage systems. Four drainage methods namely open ditch, vinyl barrier, pipe drainage and tube bundle were installed within 1-m position at the lower edge of the upper paddy fields. Stress Day Index (SDI) approach was developed to quantify the the cumulative effect of stress imposed on a soybean yield throughout the growing season. SDI was determined from a stress day factor (SD) and a crop susceptibility factor (CS). The stress day factor is a measure degree and duration of stress of the ($SEW_{30}$). The crop susceptibility factor (CS) depends of a given excess water on crop stage. The results showed that SDI used to represent the moisture stress index was most low on the pipe drainage 64.75 compared with the open ditch 355.4, vinyl barrier 271.55 and tube bundle 171.55. Soybean grain yield increased continuously with the rate of 3% in Vinyl Barrier, 32% in Pipe Drainage and 16% in Tube Bundle.

A Study about Effectiveness and Usefulness of a FEM Slug Test Model (유한 요소기법을 이용한 Slug시험 모델의 타당성 및 유용성 연구)

  • 한혜정;최종근
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.89-96
    • /
    • 2000
  • Slug tests are the most widely used field method for quantification of hydraulic conductivity of porous media. Well recovery is affected by well casing, borehole radii, screened length, hydraulic conductivity, and specific storage of porous media. In this study, a new slug tests model was developed through finite element approximation and the validity and usefulness of the model were tested in various ways. Water level fluctuation in a well under slug test and cons-equent groundwater flow in the surrounding porous medium were appropriately coupled through estimation of well-flux using an iteration technique. Numerical accuracy of the model was verified using the Cooper et al. (1967) solution. The model has advantages in simulations for monitored slug tests, partial penetration, and inclusion of storage factor. Volume coverage of slug tests is significantly affected by storage factor. Magnitude and speed of propagation of head changes from a well increases as storage factor becomes low. It will be beneficial to use type curves of monitored head transients in the surrounding porous formation for estimation of specific storage. As the vertical component of groundwater flow is enhanced, the influence of storage factor on well recovery decreases. For a radial-vertical flow around a partially penetrated well, deviations between hydraulic estimates by various methods and data selection of recovery curve are negligible on practical purposes, whereas the deviations are somewhat significant for a radial flow.

  • PDF

The role of geophysics in understanding salinisation in Southwestern Queensland (호주 Queensland 남서부 지역의 염분작용 조사)

  • Wilkinson Kate;Chamberlain Tessa;Grundy Mike
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.78-85
    • /
    • 2005
  • This study, combining geophysical and environmental approaches, was undertaken to investigate the causes of secondary salinity in the Goondoola basin, in southwestern Queensland. Airborne radiometric, electromagnetic and ground electromagnetic datasets were acquired, along with data on soils and subsurface materials and groundwater. Relationships established between radiometric, elevation data, and measured material properties allowed us to generate predictive maps of surface materials and recharge potential. Greatest recharge to the groundwater is predicted to occur on the weathered bedrock rises surrounding the basin. Electromagnetic data (airborne, ground, and downhote), used in conjunction with soil and drillhole measurements, were used to quantify regolith salt store and to define the subsurface architecture. Conductivity measurements reflect soil salt distribution. However, deeper in the regolith, where the salt content is relatively constant, the AEM signal is influenced by changes in porosity or material type. This allowed the lateral distribution of bedrock weathering zones to be mapped. Salinisation in this area occurs because of local-andintermediate-scale processes, controlled strongly by regolith architecture. The present surface outbreak is the result of evaporative concentration above shallow saline groundwater, discharging at break of slope. The integration of surficial and subsurface datasets allowed the identification of similar landscape settings that are most at risk of developing salinity with groundwater rise. This information is now being used by local land managers to refine management choices that prevent excess recharge and further salt mobilisation.

Evaluation on Damage Effect of Concrete Track induced by Underground Structure Displacement Behavior (지하구조물 변위거동에 따른 콘크리트궤도의 손상영향 분석)

  • Jung-Youl Choi
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.839-844
    • /
    • 2024
  • This study analytically analyzed the impact of underground structure displacement behavior on track damage due to adjacent excavation work, ground deterioration, and changes in groundwater level. The concrete track that was the subject of the study was analyzed for sleeper floating track(STEDEF) and precast concrete slab track(B2S). Sleeper floating track is a track structure in which the concrete bed and sleepers are voided. precast concrete slab track is a track structure that induces the elastic behavior of the rail by assembling rails and fasteners using slabs. For numerical analysis, each concrete track, from rail to concrete bed, was modeled as three-dimensional elements. In addition, the displacement behavior of the underground structure was set as a variable to analyze the damage effect on the concrete bed. Using numerical analysis, the concrete bed stress due to uplift and subsidence was analyzed, and the level of crack effect was analyzed by comparing it to the tensile strength and shear strength. As a result of the analysis, it was found that the sleeper floating track was more vulnerable than the precast concrete slab track when the same uplift and subsidence occurred. In addition, uplift and subsidence, it was analyzed that the cracks range in the sleeper floating track was large.

Baseflow Separation from Complex Hydrograph using Eckhart Filter (Eckhart filter를 이용한 복합수문곡선에서의 기저유출분리)

  • Kang, Boo-Sik;Moon, Su-Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1292-1295
    • /
    • 2009
  • 일반적으로 유역의 기저유출 산정에는 적용의 간편성을 이유로 수평직선분리법, N-day법등을 주로 사용해 왔으며 이를 단기호우사상에 대한 모의에 적용해 왔다. 그러나 수평직선분리법이나 N-day에의한 기저유량의 산출은 연구자의 주관성이 반영될 수 있는 가능성이 다분하며 총 유출에 대한 기저 유출의 기여가 상대적으로 크게 되는 장기유출모의에 이용하기에는 효율적이지 못할 뿐 아니라 분석을 수행하는 사람에 따라서 그 결과에 많은 차이가 있을 수 있다. 그래서 최근에는 이러한 문제를 해결하기 위해서 다양한 'Digital Filtering' 방법이 수문곡선 분리에 많이 사용되고 있다. Eckhardt 필터는 출력의 신호대 잡음비가 최소화를 목적함수로 사용하는 최적선형필터의 형태를 갖고 있으며, BFImax 변수 값을 이용하여 수문분석 시 대수층별 특성을 반영할 수 있는 장점을 지니고 있다. 따라서 BFImax 변수 값에 따라서 분리된 직접유출과 기저유출 값에는 상당한 차이가 발생할 수 있는데, 정확한 수문분석을 위해서는 연구대상 유역 내 대수층의 특성에 가장 부합되는 BFImax 변수 값을 구하여야 하는 어려움이 있다. 이러한 문제를 해결하기 위하여 감수곡선 분석방법과 최적화 기법을 이용하여 BFImax 변수 값을 결정해 주는 모듈을 사용하고 있다. 금강유역의 수문곡선분리를 위해 먼저 금강 유역 내 관측소의 강우 및 수위 일 자료를 수집하고 수위자료는 동향, 옥천, 천천, 청성, 호탄지점의 자료를 이용하였다. 관측단위는 일 단위를 사용하였다. 분리된 수문곡선에 대한 검증은 지하수관측이나 중간유출에 대한 관측에 한계가 있기 때문에 정량적인 검증은 쉽지 않은 상황이고 수문곡선에 대한 시각적 판단에 의지하고 있다. 하지만 효과적인 기저유출분리가 가능해진다면 하천 건천화에 대한 정확한 진단과 함께 기후변화에 따른 지하수 및 지표수 영향에 대한 보다 신뢰도 있는 전망이 가능해지므로 매우 중요한 연구 분야라 판단된다.

  • PDF