• Title/Summary/Keyword: 지질 표준물질

Search Result 43, Processing Time 0.036 seconds

A Comparison of Laser Flash and the Divided-bar Methods of Measuring Thermal Conductivity of Rocks (암석 열전도도 측정을 위한 Laser Flash Method와 Divided-bar Method 비교)

  • Oh, Jae-Ho;Kim, Hyoung-Chan;Park, Jeong-Min
    • Economic and Environmental Geology
    • /
    • v.44 no.5
    • /
    • pp.387-397
    • /
    • 2011
  • In this study, we conducted the study of the merits and demerits of the laser flash and the divided-bar methods for measuring the thermal conductivity of rocks and investigated applicability of the divided-bar apparatus which was developed by KIGAM. The laser flash method can measure thermal diffusivity, specific heat capacity, and thermal conductivity of rocks with even small thickness (< ~3 mm) in the high temperature range($25-200^{\circ}C$) in non-contact mode. For the laser flash method, samples must be uniform and homogeneous. In the case of the divided-bar method, the apparatus measures only thermal conductivity of rock samples at the room temperature. We measured thermal conductivities of 12 rock samples with low density and high porosity using two methods. In the laser flash method, there exist potential errors caused by the effect of pulse dispersion and reflection by various minerals and porosity in rock samples; the difference in thermal conductivity values measured on the front surface and the opposite surface ranges from 0.001 to 0.140 W/mK with the standard deviation of 0.003~0.089 W/mK, which seems to be caused by heterogeneity of rock samples. On the contrary, the divided-bar apparatus shows stable thermal conductivity measurements and relatively small measurement errors; the difference in thermal conductivity values, just as we applied to the laser frash method, is 0.001~0.016 W/mK with the standard deviation 0.001~0.034 W/mK. In turn, the divided-bar method can be applied to more thick samples that are more representative of bulk thermal conductivity.

Structure and physical properties of the earth crustal material in the middle of Korean Peninsula : A study on the prescription of standard test by mortar-bar method (한반도 중부권 지각물질의 구조와 물성연구 : 콘크리트 공시체에 의한 표준시험 규정에 대하여)

  • 정진곤;유신애
    • The Journal of Engineering Geology
    • /
    • v.5 no.2
    • /
    • pp.193-200
    • /
    • 1995
  • It has been well known that the alkali-aggregate reaction between the aggregates and cement paste is one of the reasons of a concrete siructre expansion. Because of a serious demage on the concrete stnicture from the expansion, in many countries, the safety of the materials is checked in laboratory by mortar-bar test and the upper limit of expansion in length is 0.1%. The prescriptions are presented in the ASTM C227 and 490 of U.S. which has been international currency and in the KS Handbook F2503, F2546 and L5107 of Korea published by Korean Standards Association. Both of the prescriptions are almost same in their contents. Actually, in the process of preparing and measuring the mortar-bar according to the prescription mentioned above, it seems that there are no problems for its own purpose but a few points are found to be improved upon the methods to increase the accuracy for laboratory work as follows. 1. The prescription of blending ratio(aggregate, cement and water) should be noted by volume not by weight. 2. It is unreasonable to measure the initial length of mortar bars after 24$\pm$2 hours at once regardless the kind of aggregates. 3. It may bring about errors in calculating the expansion ratio under the condition of the denominator value fixed as 254mm. 4. The measuring methods of specific gravity are selected according to the purposes but the pure specific gravity displays the highest accuracy among them.

  • PDF

Standardization Studies for the Oriental Mineral Medicine (광물성 약재(광물약)의 표준화에 관한 연구)

  • Kim, Seon-Ok;Park, Maeng-Eon
    • Economic and Environmental Geology
    • /
    • v.48 no.3
    • /
    • pp.187-197
    • /
    • 2015
  • Oriental mineral medicines are single or mixture of more than one mineral species or rock/fossil which are used to treat disease. Mineral medicines remove harmful or useless substances to decrease toxicity and secondary effects, and cause the manufacture of medical compounds with increased efficacy. The extraction test is an accepted in vitro system to predict the bioaccessibility of major and minor elements from mineral medicine. It incorporates gastrointerstinal tract parameters representative of a human body that including stomach and small intestinal pH which are the same as digestion condition. The bioaccessibility of a mineral medicine is the fraction that is soluble in the gastrointestinal environment and is available for absorption. Reaction path modeling in the human body can predict digestion with gastric fluid as well as absorption in the small intestine, existence in body fluids and reaction progress of the exhaust process according to pH conditions in body. Also reaction path modeling can predict bioavailability, which is equal to existence rate in the body and the form and amount of a medicine in the body after intake. The study results from predicating the existence form mineral medicines in the body, and proving the effective ingredient using bioaccessibitily and human risk assessment, suggest these that should be necessary data for new medicine development.

A simple method to determine lycopene in solid supplementary food preparations using saponification and liquid chromatography (비누화 및 액체크로마토그래프를 활용한 고상 건강기능식품 중 라이코펜 분석법 개발)

  • Young Min Kim;Ye Bin Shin;Min Kyeong Kwon;Jin Hwan Kim;Ji Seong Kim;Dong-Kyu Lee;Myung Joo Kang;Yong Seok Choi
    • Analytical Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.105-112
    • /
    • 2023
  • Lycopene, a carotenoid hydrocarbon is known to have effects on reducing cardiovascular risk factors, blood lipids, and blood pressure. Thus, a lot of supplementary foods with lycopene in several dosage forms like soft capsule filled with liquid and hard capsule filled with powder are available in a market. Recently, however, our research group found that the lycopene assay in Supplementary Food Code of South Korea is only valid for oily lycopene preparation. Thus, here, we developed a simple method to determine lycopene in solid preparations for Supplementary Food Code of South Korea using saponification and liquid chromatography with an absorbance detector. The method was validated following Ministry of Food and Drug Safety guidelines. All validation parameters observed in this study were within acceptable criteria of the guidelines (selectivity, linearity of r2 ≥ 0.991, lower limit of quantification of 0.0149 mg/mL, accuracy as recovery (R) between 92.70 and 97.18 %, repeatability as relative standard deviation (RSD) values of R between 0.85 and 1.59 %, and reproducibility as the RSD value of interlaboratory R of 3.70 %). Additionally, the practical sample applicability of the validated method was confirmed by accuracy between 98.81 and 101.59 % observed from its lycopene certified reference material (CRM) analyses. Therefore, the present method could contribute to fortify the supplementary food safety management system in South Korea.

Elli-Situ 2000 (in situ, 실시간 표면 및 박막 모니터 장비)

  • 방현용;주한용
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.46-46
    • /
    • 2000
  • 과학기술 및 산업의 발달로 인하여 실험 중 또는 공정 상에서 in situ, 실시간으로 측정하고 분석하며 이를 되먹임하는 품질제어의 중요성이 대두되고 있다. 반도체 공정 또는 박막제조 공정 중에서 박막의 두께, 굴절율, 물질의 조성비 등을 알아내는 것이 긴요한 과제로 대두되고 있으며, 이를 위하여 공정중인 제품의 품질을 실시간으로 평가하는 장비가 요구되고 있는 것이다. 나아가 공정중의 예상하지 못한 시료의 특성변화를 그대로 감지하여 적절히 보정해 주는 되먹임 기법은 높은 수율을 보장하는 첨단기법이라 할 수 있다. 이러한요구에 부응할 수 있는 본 제품(Elli-situ 2000)은 박막의 두께 표면변화를 sub 의 정밀도를 가지고 in situ, 실시간으로 정밀 측정할 수 있는 첨단 계측장비로서 빛의 편광상태 변화를 측정하기 때문에 공정 중의 시료에 영향을 주지 않는 비간섭 특성과 비접촉 특성의 장점 뿐만 아니라 공기중에서는 물론 진공이나 액체 등의 매질에서도 사용될 수 있어서 매질에 대한 제약이 거의 없다는 장점도 가지고 있다. 편광상태의 제어 및 측정을 필요한 광학장비의 경우, 제작이 까다롭기 때문에 대부분 가격이 높은 편이고 사용방법이나 측정 데이터에 대한 해석이 어렵다는 단점이 있으나, Elli-situ 2000의 경우 상용화된 외국제품(국내제품은 없슴)과 비교하여 성능 및 가격경쟁력에 있어서도 우위에 있으며 간단, 명료한 장비조작 및 컴퓨터를 사용한 구동의 전자동화를 이룸으로써 초보자도 쉽게 측정하고 데이터를 처리할 수 있도록 하였다. 또한 취부대의 경우, 진공포트 플랜지의 표준규격(2-3" Del-Seal 플랜지 규격)에 맞춤으로써 기존의 진공챔버에 부착하여 진공에 전혀 영향을 주지 않는 상태에서 시료의 변화를 in situ, 실시간으로 정밀 측정할 수 있도록 하였다. 하였다.O 박막은 산소 가스압력과 기판온도, 인가 전류를 변화시켜가며 증착하였으며 이에 따른 박막의 결정성 변화를 알아보았다. 기판온도를 실온에서 점차 증가시켜나가면 $\Delta$$\theta$50은 급격히 감소하며 30$0^{\circ}C$에서는 결정성이 우수한 막을 얻을 수 있었다. 또한 산소 가스 압력이 0.5~1mTorr에서 $\Delta$$\theta$50은 양호한 값을 나타내었지만 그 이상에서는 c-축 배향성이 나빠짐을 확인하였다. 따라서 대향타겟식스퍼터 장치를 이용하여 ZnO 박막을 증착시 가스압력 0.5~1mTorr, 기판온도 20$0^{\circ}C$이상의 막 제작조건에서 결정성이 우수하게 나타나는 것을 확인할 수 있었다. gluten이 단단해졌음을 알수 있었다. 유화제 stearly 칼슘, 혹은 hemicellulase를 amarans 10% 대체한 밀가루에 첨가하면 확연히 비용적을 증대시킬 수 있다는 사실을 알 수 있었다. quinoa는 명아주과 Chenopodium에 속하고 페루, 볼리비아 등의 고산지에서 재배 되어지는 것을 시료로 사용하였다. quinoa 분말은 중량의 5-20%을 quinoa를 대체하고 더욱이 분말중량에 대하여 0-200ppm의 lipase를 lipid(밀가루의 2-3배)에 대하여 품질개량제로서 이용했다. 그 결과 quinoa 대량 7.5%에서 비용적, gas cell이 가장 긍정적 결과를 산출했고 반죽의 조직구조가 강화되었다. 또 quinoa 대체에 의해 전분-지질 복합제의 흡열량이 증대된 것으로부터 전분-지질복합제의 형성 촉진이 시사되었다.이것으로 인하여 호화억제에 의한 노화 방지효과가 기대되었지만 실제로 빵의 노화는 현저히 진행되었다. 이것은

  • PDF

Effects of Taeumin, Soeumin and Soyangin Prescriptions on the Adipocyte Induced by Gold Thioglucose in the Rat (태(太)·소음인(少陰人), 소양인(少陽人)의 처방(處方)이 Gold thioglucose로 유발(誘發)된 백서(白鼠)의 비만병(肥滿病)에 미치는 효과(效果))

  • Kim, Kyung-Yo
    • Journal of Sasang Constitutional Medicine
    • /
    • v.8 no.1
    • /
    • pp.295-317
    • /
    • 1996
  • It is researched to elucidate the effects of Taeumjowuitang(TE,太陰調胃湯), Sibimikwanjungtang(SE, 十二味寬中湯) and Yangkeogsanwhatang(SY,凉膈散火湯) on the obesity induced by gold thioglucose and the differentiation and growth of preadipocyte 3T3-L1 in the mouse. The result were as follows: 1. TE,SE and SY extracts improved the blood level of transaminase in the obese mouse induced by gold thioglucose. 2. TE,SE and SY extracts inhibited the increase of liver fat and body fat in the obese mouse induced by gold thioglucose. 3. TE,SE and SY extracts inhibited the increase of body weight in the obese mouse induced by gold thioglucose. 4. TE,SE and SY extracts inhibited the growth of undifferentiate preadipocyte 3T3-L1. 5. TE,SE and SY extracts showed inhibitory effect on the differentiation of preadipocyte 3T3-L1. The above results suggest that the TE,SE and SY extracts may be used on the obesity induced by the overgrowth and differentiation of adipocyte, and the accumulation of fat in liver and body.

  • PDF

Performance Analysis of a Deep Vertical Closed-Loop Heat Exchanger through Thermal Response Test and Thermal Resistance Analysis (열응답 실험 및 열저항 해석을 통한 장심도 수직밀폐형 지중열교환기의 성능 분석)

  • Shim, Byoung Ohan;Park, Chan-Hee;Cho, Heuy-Nam;Lee, Byeong-Dae;Nam, Yujin
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.459-467
    • /
    • 2016
  • Due to the limited areal space for installation, borehole heat exchangers (BHEs) at depths deeper than 300 m are considered for geothermal heating and cooling in the urban area. The deep vertical closed-loop BHEs are unconventional due to the depth and the range of the typical installation depth is between 100 and 200 m in Korea. The BHE in the study consists of 50A (outer diameter 50 mm, SDR 11) PE U-tube pipe in a 150 mm diameter borehole with the depth of 300 m. In order to compensate the buoyancy caused by the low density of PE pipe ($0.94{\sim}0.96g/cm^3$) in the borehole filled with ground water, 10 weight band sets (4.6 kg/set) were attached to the bottom of U-tube. A thermal response test (TRT) and fundamental basic surveys on the thermophysical characteristics of the ground were conducted. Ground temperature measures around $15^{\circ}C$ from the surface to 100 m, and the geothermal gradient represents $1.9^{\circ}C/100m$ below 100 m. The TRT was conducted for 48 hours with 17.5 kW heat injection, 28.65 l/min at a circulation fluid flow rate indicates an average temperature difference $8.9^{\circ}C$ between inlet and outlet circulation fluid. The estimated thermophysical parameters are 3.0 W/mk of ground thermal conductivity and 0.104 mk/W of borehole thermal resistance. In the stepwise evaluation of TRT, the ground thermal conductivity was calculated at the standard deviation of 0.16 after the initial 13 hours. The sensitivity analysis on the borehole thermal resistance was also conducted with respect to the PE pipe diameter and the thermal conductivity of backfill material. The borehole thermal resistivity slightly decreased with the increase of the two parameters.

Low Dilution Glass Bead Digestion Technique for the Trace Element Analysis of Rock Samples (저희석 유리구 용해법에 의한 암석시료 미량원소 분석법)

  • Park, Chan-Soo;Shin, Hyung-Seon;Oh, Hae-Young;Moon, Jong-Hwa;Cheong, Chang-Sik
    • The Journal of the Petrological Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.161-172
    • /
    • 2011
  • Open beaker digestion method is routinely used as the sample preparation technique for trace element determination of rock samples by inductively coupled plasma mass spectrometry, With this method, however, dissolution of Zr and Hf is not always guaranteed especially when the samples contain refractory minerals. In this study, glass bead digestion technique was compared with conventional open beaker digestion technique for the sample preparation of three USGS rock standards such as AGV-2, BHVO-2, and G-3. Thirty trace elements including rare earth elements were analysed by ICP-MS and ICP-AES. There were no clear differences in analytical results for the AGV-2 and BHVO-2 standards between the two techniques, but Zr, Hf, Y, and middle- to heavy- rare earth element concentrations of the G-3 standard prepared by open beaker digestion technique were significantly lower than the recommended values. This can be attributed to the presence of refractory mineral zircon. On the contrary, all the analytical results of the G-3 standard prepared by glass bead digestion technique were in good agreement with the recommended values, indicating complete dissolution of zircon. The analytical results show that the volatile elements such as Pb and Zn were not lost during the preparation of glass bead. Low dilution glass bead digestion technique described here will be very helpful to enhance precision and accuracy of trace element analysis for geological samples containing refractory minerals.

Nutritional quality of Peucedanum japonicum Thunb. leaves in relation to ripening time, growing condition and blanching (재배조건, 수확시기 및 열처리에 따른 갯기름나물의 영양성분 변화)

  • Jin, Yong-Xie;Cho, Young-Sook;Choi, Youngmin
    • Food Science and Preservation
    • /
    • v.21 no.6
    • /
    • pp.784-789
    • /
    • 2014
  • This work aimed to investigate the changes in the nutrient contents and antioxidant activity of Peucedanum japonicum Thunb. by ripening stage, growing condition, and blanching. The crude protein content of the young leaves (3.6~4.3%) was higher than that of the mature leaves (3.1~3.9%). Higher calcium contents were observed in the greenhouse-cultivated samples (225.9~259.2 mg/100 g) compared to the field-cultivated samples (178.5~199.5 mg/100 g). The vitamin C and folate contents (18.1~83.8 and 175.8~220.2 mg/100 g, respectively) of the field-cultivated samples were significantly (p<0.05) higher than those of the greenhouse-cultivated samples (13.1~57.7 and 133.0~148.8 mg/100 g, respectively). The growing condition and blanching were significant factors affecting the changes in the vitamin and polyphenol contents. The ${\beta}$ carotene contents of the blanched samples increased 2.6-fold compared to those of the raw samples. The total polyphenol contents (10.2~17.1 mg/g extract) and DPPH radical scavenging activity ($IC_{50}=2.0{\sim}3.0mg/ml$) of the blanched samples were significantly (p<0.05) higher than those of the raw samples (1.8~4.3 and $IC_{50}=16.2{\sim}21.1mg/ml$, respectively).

Standardization of Hydration in the Stratum Corneum Using by Polyols (폴리올을 이용한 각질층 수분량 측정의 표준화 연구)

  • Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.2
    • /
    • pp.113-119
    • /
    • 2015
  • The measurement of hydration level in the surface layer of the skin, stratum corneum (SC), gives important information on the biophysical properties and function of the skin barrier such as softness, flexibility, and healthiness of the skin. But it is difficult to measure a consistent hydration level from a sample to another sample due to individual variations and environmental changes. The aim of this study was to evaluate objective hydration after using various products in the SC. The SC Hydration was measured by capacitance (Corneometer$^{(R)}$, C+K, Germany) on the ventral site of forearm from 40 healthy volunteers. The skin surface was chronologically measured immediately after application of the test products and 3 and 6 hours later. We analyzed the averages of five measurements of each site and used the hydration increase rate for correction on untreated site variation. We found that most polyols including glycerol and butylenes glycol influenced directly the hydration increase rate in the SC previously. In this study, glycerol was used to prepare the standard products from 0 to 20 percents and applied to the same volunteers. The individual standard curve showed linear relation to glycerol concentrations. Based on the the standard curve, hydration of SC was converted into hydration increase rate to glycerol concentrations. The converted glycerol concentrations of products were repetitive and reproducible. In addition, the individual standard curve was used to relate the skin type of each individual. These results suggest that the hydration of the SC standardized regardless of external variation and individual skin condition can explain detailed skin state variation. Further studies will be conducted with other ingredients such as surfactants, lipids and aqueous materials, and with other methods for noninvasive measurement.