• Title/Summary/Keyword: 지진계

Search Result 273, Processing Time 0.022 seconds

Lumped Parameter Model of Transmitting Boundary for the Time Domain Analysis of Dam-Reservoir System (댐의 시간영역 지진응답 해석을 위한 호소의 집중변수모델)

  • 김재관;이진호;조정래
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.27-38
    • /
    • 2001
  • A mechanical lumped parameter model is proposed for the dynamic modeling of a semi-infinite reservoir. A semi-analytic transmitting boundary is derived for a semi-infinite 2-D reservoir of constant depth. The characteristics of the solution are examined in both frequency and time domains. Mass, damping and spring coefficients of the mechanical model are obtained to preserve the major features of the solution such as eigenfrequencies and the shapes of Bessel functions that appear as kernels in the convolution integrals. The lumped parameter model in its final form consists of two masses, a spring and two dampers for each eigenfrequency. Application examples demonstrated that the new lumped parameter model could be used for the time domain analysis of dam-reservoir systems.

  • PDF

Triaxial Shake Table Test about Seismic Performance of Ceiling System with Gypsum Panels (석고 패널이 부착된 천장 시스템의 내진성능 평가를 위한 3축 진동실험)

  • Park, Hae-Yong;Jeon, Bub-Gyu;Kim, Jae-Bong;Gim, Min-Uk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.143-153
    • /
    • 2019
  • In this study, a full scale 3-axes shake table test for M-bar and T-bar type ceilings commonly used in the country was conducted. Through damage inspection during the test, seismic performance of ceilings according to variables, such as clearance between wall mold and ceiling as well as existence of facilities, was evaluated. A test frame consisted of square hollow section members was used for the shake table test. The experimental method was performed as a fragility test using required response spectrum described in ICC-ES AC156. In the case of architectural nonstructural component that contain ceilings, it mainly is evaluated the performance by post-test visual inspection. For the evaluation of seismic performance of ceilings, this study classified and defined damaged items for targeted ceiling system referring to illustrative damage according to nonstructural performance levels accordance with ASCE 41 and previous studies. And proposed illustrative damage items classification was utilized to compare the degree of the damage according to experimental variables. The experiment results confirmed that differences in boundary conditions due to the clearance at wall mold and the installation of facilities had a significant effect on the seismic performance of the ceiling.

Transient Ground Deformation induced by Sequential Earthquakes and Estimation of Underground Water Pipeline Performance in Canterbury, New Zealand (뉴질랜드 캔터배리 지역 연속지진에 의해 발생된 일시지반변형과 매설된 상수도관 성능평가)

  • Jeon, Sang-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2818-2827
    • /
    • 2015
  • The spatial patterns and characteristics of these sequential earthquakes and ground motions induced by the earthquakes are examined by contours of peak ground velocity (PGV) and geometric mean peak ground velocity (GMPGV) using both ordinary kriging in geographical information system (GIS) and data, the records obtained from strong motion stations, acquired after recent sequential earthquakes in Canterbury, New Zealand (NZ). The performance of underground water pipeline system is examined by using data acquired after earthquakes. The spatial distribution of GMPGV is superimposed on water pipeline repairs throughout the water distribution system in areas affected principally by transient ground motion using GIS and then water pipeline repair rates, expressed as repairs/km, for different types of pipe are evaluated relative to the estimated GMPGV outside liquefaction areas. The earthquake performance of underground water pipeline systems is summarized in this study.

Development of a Kit for Realtime transmission of data acquired by Earthquake accelerometers (지진가속도 계측기의 실시간 자료 전송 Kit 개발)

  • Heo, Jeongpil;Kim, Kiseog;Lim, Inseub;Jin, Jocheol
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.2
    • /
    • pp.254-262
    • /
    • 2014
  • KISStool is developed and established by KIGAM, in order to link and share the earthquake data easily with institutes related, this study includes the development of a KISStool program format and protocol supporting Kit. The Kit has functions such as transforming and sending a seismic data. The functions of the kit are implemented in modules, which are running on the realtime basis. The firmware is embedded into the Kit, which transforms the seismic data into the formats, miniSEED and QSCD20. These data are sent to KISStool program. We have confirmed the results of the data transforming, transmissions and storage functions are conducted normally, the speed of transmission shows same level when comparing with a standard system. We expect that the firmware developed in this study will have high usability not only for linking with KISStool program through being embedded into incompatible digitizers, but also for improving performance of older ones.

Effect of the Nonlinearity of the Soft Soil on the Elastic and Inelastic Seismic Response Spectra (연약지반의 비선형성이 탄성 및 비탄성 지진응답스펙트럼에 미치는 영향)

  • Kim, Yong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.4 s.44
    • /
    • pp.11-18
    • /
    • 2005
  • Inelastic seismic analysis is necessary for the seismic design due to the nonlinear behavior of a structure-soil system, and the importance of the performance based design considering the soil-structure interaction is recognized for the reasonable seismic design. In this study, elastic and inelastic seismic response analyses of a single degree of freedom system on the soft soil layer were peformed considering the nonlinearity of the soil for the 11 weak or moderate, and 5 strong earthquakes scaled to the nominal peak acceleration of 0.075g, 0.15g, 0.2g and 0.3g. Seismic response analyses for the structure-soil system were peformed in one step applying the earthquake motions to the bedrock In the frequency domain, using a pseudo 3-D dynamic analysis software. Study results indicate that it is necessary to consider the nonlinear soil-structure interaction effects and to perform the performance based seismic design for the various soil layers rather than to follow the routine procedures specified in the seismic design codes. Nonlinearity of the soft soil excited with the weak earthquakes also affected significantly to the elastic and inelastic responses due to the nonlinear soil amplification of the earthquake motions, and it was pronounced especially for the elastic ones.

Required Strength Spectrum of Low-Rise Reinforced Concrete Shear Wall Buildings with Pilotis (필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 요구내력 스펙트럼)

  • Lee, Kang-Seok;Oh, Jae-Keun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.61-69
    • /
    • 2007
  • The main purpose of this study is to provide a basic information for the seismic capacity evaluation and the seismic design of low-rise reinforced concrete (RC) shear wall buildings, which are comprised of a pilotis in the first story. In this study, relationships between strengths and ductilities of each story of RC buildings with pilotis are investigated based on the nonlinear seismic response analysis. The characteristics of low-rise RC buildings with pilotis are assumed as the double degree of freedom structural systems. In order to simulate these systems, the pilotis is idealized as a degrading trilinear hysteretic model that fails in flexure and the upper story of shear wall system is idealized as a origin-oriented hysteretic model that fails in shear, respectively. Stiffness properties of both models are varied in terms of story shear coefficients and structures are subjected to various ground motion components. By analyzing these systems, interaction curves of required strengths for various levels of ductility factors are finally derived for practical purposes. The result indicates that the required strength levels derived can be used as a basic information for seismic evaluation and design criteria of low-rise reinforced concrete shear wall buildings having pilotis structure.

경계요소법에 의한 대규모 3차원 지하구조물의 동적해석

  • 한국전산구조공학회
    • Computational Structural Engineering
    • /
    • v.8 no.3
    • /
    • pp.11-21
    • /
    • 1995
  • 3차원 대규모 지하구조물의 동적응답을 결정하기 위한 일반적인 수치해석이 제안되었다. 지반과 구조물을 해석하기 위하여 Laplace 변환을 적용한 경계요소법을 설명하였고, 지반-구조물계에 작용하는 외부 동적하중과 지진파를 고려할 수 있도록 공식화하였다. 동적교란이 전파되는 경우에 시간영역의 응답을 얻기 위하여는 구해진 변화된 해를 수치적인 Laplce 역변환을 수행하여야 하지만 동적교란이 조화적인 경우에는 응답이 주파수 영역으로부터 직접 얻어지며, 역변환이 필요하지 않다. 이 방법의 특징은 높은 정확도와 효율성이며, 지반-구조물계에 대하여 초기조건 및 점탄성 재료의 거동을 쉽게 고려할 수 있다는 것이다. 그러므로 이 방법은 다양한 지하구조물의 동적거동과 지진에 대한 취약함을 연구하기 위한 적절한 도구로 사용되어 질 수 있다.

  • PDF

Shaking table test for analysis of seismic performance of cut and cover tunnel using EPS block as backfill material (개착식 터널의 뒤채움재로 EPS블럭의 내진 성능 평가를 위한 진동대 시험)

  • Kim, Nag-Young;Lee, Yong-Jun;Lee, Seung-Ho;Chung, Hyung-Sik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.4
    • /
    • pp.333-342
    • /
    • 2002
  • World widely, the occurrences of earthquakes have been increased recently. Speculating from cases of earthquakes in the world, it is reported that damages have been made underground structures like cut-and-cover tunnels, especially on the upper of tunnel with a shallow depth and the backfilled area adjacently by earthquakes. Earthquakes have a tendency to increase recently in Korea but it is deficient in seismic design criteria. In this study, Shaking table test on both soil and EPS blocks was performed to analyze the efficiency of the seismic performance of the cut-and-cover tunnels according to characteristic of backfill materials and embanking material. It turned out to be effective in improving the seismic performance according to analysis of strain and bending stress of tunnel by earthquakes.

  • PDF

Analysis of Seismic Behaviour of Cut and Cover Tunnel according to backfill materials (뒤채움재 특성별 개착식 터널의 동적 거동 특성 연구)

  • Kim, Nag-Young;Lee, Seung-Ho;Lee, Yong-Jun;Kim, Jung-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.2
    • /
    • pp.177-186
    • /
    • 2005
  • World widely, the occurrences of earthquakes have been increased recently including to nations which earthquake often happen to like Japan. Taking into account that the earthquake acceleration at design was 0.154 g at the contigency level earthuake (CLE) with its geological condition, it resulted that this method must be the most efficient condition against the earthquake vibration to two lane cut-and cover tunnel. The correlations between the result of the shaking table test and its numerical analysis showed that the test data of the bending stress due to the earthquake vibration have been underestimated about 5 percents in case of the cut slope 1 : 0.6 and about 10 percent in case of the cut slope 1 : 1.2. However, on average, the results showed a similar tendency that the higher the height of the backfill of the EPS block was, the less the bending stress was.

  • PDF

Multi-Objective Optimization of Steel Frames For Standardized Steel Profiles Under Seismic Loads (지진하중을 받는 강뼈대구조물의 표준단면에 대한 다목적 최적설계)

  • Cho, Hyo Nam;Min, Dae Hong;Jeong, Bong Gyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.783-791
    • /
    • 2002
  • An improved formulation for multi-objective optimization was proposed. This formulation was applied to steel seismic loads. The multi-objective optimization problem was formulated with minimum structural weight, maximum strstability. The global criterion method was employed to find a rational solution closest to the ideal solution for the optimization problem using standard steel profile, To efficiently solve the optimization problem, the decomposition meth both system-level and element-level was used. In addition, various techniques including efficient reanalysis technique intermediate variables and sensitivity analysis using an automatic differentiation(AD) were incorporated. Moreover the reamong section properties fitted to the section profile used in order to link the system level and the element level. From numerical investigation, it could be stated that the proposed method will lead to the more rational design compared with one.