• Title/Summary/Keyword: 지지구조물

Search Result 740, Processing Time 0.03 seconds

Reliability Based Stability Analysis and Design Criteria for Reinforced Concrete Retaining Wall (신뢰성(信賴性) 이론(理論)에 의한 R.C.옹벽(擁壁)의 안정해석(安定解析) 및 설계규준(設計規準))

  • Cho, Tae Song;Cho, Hyo Nam;Chun, Chai Myung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.71-86
    • /
    • 1983
  • Current R.C. retaining wall design is bared on WSD, but the reliability based design method is more rational than the WSD. For this reason, this study proposes a reliability based design criteria for the cantilever retaining wall, which is most common type of retaining wall, and also proposes the theoretical bases of nominal safety factors of stability analysis by introducing the reliability theory. The limit state equations of stability analysis and design of each part of cantilever retaining wall are derived and the uncertainty measuring algorithms of each equation are also derived by MFOSM using Coulomb's coefficient of the active earth pressure and Hansen's bearing capacity formula. The levels of uncertainties corresponding to these algorithms are proposed appropriate values considering our actuality. The target reliability indices (overturning: ${\beta}_0$=4.0, sliding: ${\beta}_0$=3.5, bearing capacity: [${\beta}_0$=3.0, design for flexure: [${\beta}_0$=3.0, design for shear: ${\beta}_0$=3.2) are selected as optimal values considering our practice based on the calibration with the current R.C. retaining wall design safety provisions. Load and resistance factors are measured by using the proposed uncertainties and the selected target reliability indices. Furthermore, a set of nominal safety factors, allowable stresses, and allowable shear stresses are proposed for the current WSD design provisions. It may be asserted that the proposed LRFD reliability based design criteria for the R.C. retaining wall may have to be incorporated into the current R.C. design codes as a design provision corresponding to the USD provisions of the current R.C. design code.

  • PDF

Studies on the Construction Method of Chwibyeong and Investigating Original Form of the Chwibyeong at the Juhapru in the Changdeok Palace (취병(翠屛)의 조성방법과 창덕궁 주합루(宙合樓) 취병의 원형규명)

  • Jung, Woo-Jin;Sim, Woo-Kyung
    • Korean Journal of Heritage: History & Science
    • /
    • v.47 no.2
    • /
    • pp.86-113
    • /
    • 2014
  • This study has researched the characteristics and elements of Chwibyeong (翠屛), a sort of trellis in the Joseon Dynasty through the old documents, and the original form of Chwibyeong at Juhapru (宙合樓) in Changdeuk Palace. The results were as follow. First, as the result of literatures analysis for Imwon-gyeongje-ji (林園經濟志) and Jeungbo-sallim-gyeongje (增補山林經濟), the plant screen was classified as kinds of support[frame] material, plants and methods of planting. It was found that the supports of Chwibyeong were made of bamboo or the material such as the Jinjangmok (眞長木: a stick of oak) and Giryu (杞柳: Salix purpurea var. japonica). The evergreen coniferous trees including Pinus densiflora, Taxus cuspidata and Thuja orientalis were mainly used for the plant material of Chwibyeong. The general planting method of Chwibyeong was to plant on the ground, but sometimes the container planting was also found on the artificial ground. Second, the term of 'Chwibyeong' in the literatures was used in only the screen made by evergreen trees, and the superordinate category term of it was indicated by 'byeong (屛)'. Therefore Chwibyeong was a compound word formed from 'chwi (翠)' which means the characteristics of evergreen and 'byeong' as tree screen which the support was made by bamboo. And Chwibyeong had semantic context which was combined with the literary symbolization to describe a landscape of green peak and Taoist ideology be inherent from 'twelve peaks of Musan[巫山十二峰]' in Sichuan sheng (四川省). Thirdly, the photograph of Chwibyeong at Juhapru taken by the 1880s, showed that Chwibyeong was made with coniferous trees and was almost 2 meters high. The Chwibyeong at Juhapru was removed during the Japanese colonial era, but a few yew trees(Taxus cuspidata) used for Chwibyeong are still remaining. And some Juniperus chinensis which the composition time is unclear, were cultivated while hung loose its branchs at the sides of Eosumun (魚水門). This Junipers were presumed to be planted by Japanese after Japanese annexation of Korea(1910), and it was judged that both of the roofs of Eosumun's side gates might have been transformed into Japanese style at the same time. Lastly, Chwibyeong at Juhapru was restored in 2008 but it was restored in wrong way from original form without precise research. Especially Chwibyeong was restored with Sasa boreralis which is damaged by frost, so it requires exertion that should revive the originals to plant original material as much as possible. And it needs the development of fabrication technique for Chwibyeong and the application to current landscape architecture.

A Study on Trust and Commitment between Buyer and Supplier of Industrial Parts, and Their Usage of Information Technology (산업재 부품 구매자와 공급자의 신뢰와 몰입, 그리고 정보기술의 이용에 관한 연구)

  • Kim, Jong-Hun;Yun, Hui-Taek
    • Proceedings of the Korean DIstribution Association Conference
    • /
    • 2006.08a
    • /
    • pp.47-68
    • /
    • 2006
  • This study aims to determine the association structure of the behavioral relationship variables, such as trust, commitment, cooperation, communication and coercive power, in the relationship between the buyers and suppliers of industrial parts. It also investigates the impact of the use of IT technologies on the relationships quality. Data was collected from 216 part suppliers of machinery, electronics and automobiles located in Incheon. Data supported all of the proposed hypotheses. First, it was confirmed that parts suppliers' trust in buyers leads to the commitment into relationships with buyers. Second, cooperation and communication showed a positive influence on parts suppliers' trust in buyers, and coercive power gave a negative influence on trust. Third, the use of IT technologies like Internet and E-Mail between parts suppliers and buyers was verified to have generally a positive influence on the quality of relationships. At the same time, cooperation and communication were confirmed to have a positive influence on each other, and cooperation and coercive power as well as communication and coercive power were confirmed to have negative influence on each other. This study is a pioneering attempt to examine the relationships between suppliers and buyers of industrial parts, and the influence IT technologies on the relationship quality. Also, the findings will be practically much helpful to find how to reinforce the relationships between parts suppliers and buyers.

  • PDF

Evaluation on Thermal Performance Along with Constructability and Economic Feasibility of Large-diameter Cast-in-place Energy Pile (대구경 현장타설 에너지파일의 열교환 성능과 시공성 및 경제성 분석)

  • Park, Sangwoo;Sung, Chihun;Lee, Dongseop;Jung, Kyoungsik;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.5
    • /
    • pp.5-21
    • /
    • 2015
  • An energy pile is a novel type of ground heat exchangers (GHEX's) which sets up heat exchange pipes inside a pile foundation, and allows to circulate a working fluid through the pipe for exchanging thermal energy with the surrounding ground stratum. Using existing foundation structure, the energy pile can function not only as a structural foundation but also as a GHEX. In this paper, six full-scale energy piles were constructed in a test bed with various configurations of the heat exchange pipe inside large-diameter cast-in-place piles, that is, three parallel U-type heat exchangers (5, 8 and 10 pairs), two coil type heat exchangers (with a 500 mm and 200 mm pitch), and one S-type heat exchanger. During constructing the energy piles, the constructability of each energy pile was evaluated with consideration of the installation time, the number of workers and any difficulty for installing. In order to evaluate the thermal performance of energy piles, the thermal performance tests were carried out by applying intermittent (8 hours operating-16 hours pause) artificial cooling operation to simulate a cooling load for commercial buildings. Through the thermal performance tests, the heat exchange rates of the six energy piles were evaluated in terms of the heat exchange amount normalized with the length of energy pile and/or the length of heat exchange pipe. Finally, the economic feasibility of energy pile was evaluated according to the various types of heat exchange pipe by calculating demanded expenses per 1 W/m based on the thermal performance test results along with the market value of heat exchange pipes and labor cost.

A Study The Structural Stability of the Fence Ohgokmun Soswaewon Factor Analysis (소쇄원 오곡문 담장의 구조적 안정에 미치는 요인 분석)

  • Jang, Ik-Sik;Jeon, Hyeong-Soon;Ha, Tae Ju;Lee, Jae-Keun
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.4
    • /
    • pp.113-122
    • /
    • 2013
  • In this study, the traditional structure of the impact on the stability analysis. Korean traditional landscape architecture column space of stonework stable composition as the foundation of the fence for a long time been known to fall down and not maintained. The destination of research Ohgokmun Damyang Soswaewon fence which is in harmony with nature is one of the traditional structures that affect its shape without being kept so far came true. This includes our ancestral wisdom and that wisdom can guess guesswork. But I let the traditional reproduction incidence structures frequently. This deviation from the traditional method of construction application of shorthand stand. Thus, the subject of this study, the factors that do not fall down fences Ohgokmun solution is to indirectly gain the weak. In addition, epidemiological studies and the methods of calculation of the inferred physical examination, the results of the analysis were derived through the following. First, the internal factors of the fence Ohgokmun constituting the structural member and the coupling of the scheme. 1) based on stable ground. Greater role in the country rock The fact that the settlement will have no symptoms. 2) to minimize the friction caused by hydrological water to remove the two-pronged process through stone work building form and menu sustaining power in hydrology and flooding made against the bypass channel. 3) due to the load bearing capacity and durability to withstand the strength of the material and the construction of structures in the form of a dispersion of power between each individual to maximize the process of getting traction was applied. Second, external factors Ohgokmun fence the results obtained through the calculation of the dynamics of repair, is greatly affected by the wind and the water gate of the fence, but the action of the structural stability of the lack of power that hurt enough conclusion. In this study, the results of the structure of internal and external influence as well through the structure can be viewed as composed consisting. However, over the next follow-up in terms of climate and environmental factors due to the fact that the fall might.

Porewater Pressure Buildup Mode Induced in Near-field of Open-ended Pipe Pile during Earthquake and Sequake (지진과 해진시 개단강관말뚝 주변에 유발된 간극수압의 발생 양상)

  • 최용규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.23-30
    • /
    • 1998
  • During an earthquake, there are three components of excitation : horizontal excitation of the ground, vertical excitation of the pile due to superstructure feedback produced by vertical excitation of the ground, and the seawater excitation by the vertical ground shaking, that is, "the seaquake." These excitations could have effects on the pore pressure buildup mode induced in the near-field of open-ended pile and the soil plugs in open-ended pipe piles installed at offshore sites. While the ground and pile excitation could be modeled by exciting the soil and pile with simulated motions, seaquake excitation induced by the vertical ground shaking can be modeled by pulsing the water pressure at the seabed. The objectives of this study were to observe buildup trend for the porewater pressures developed in near-field of open-ended pipe pile installed in the calibration chamber during the simulated earthquake and seaquake and, also to confirm the cause for reduction of soil plugging according to pore pressure buildup. During the simulated horizontal seismic motion, there was no upward flow through soil plug because the similar magnitude of excess porewater pressure were occurred at the top and under the toe of soil plug. During the horizontal seismic motion, relatively higher hydraulic gradients caused upward flow in the soil plug and then the degradation of plugging resistance was about 20%. During seaquake, in the case of the open-ended pile installed in a deep sea with more than 220m of water depth, soil plug failed completely because of high upward hydraulic gradients through soil plug.soil plug.

  • PDF

Ambient Vibration Testing and System Identification for Tall Buildings (고층건물의 자연 진동실험 및 시스템판별)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.23-33
    • /
    • 2012
  • Dynamic response measurements from natural excitation were carried out for three 18-story office buildings to determine their inherent properties. The beam-column frame system was adopted as a typical structural form, but a core wall was added to resist the lateral force more effectively, resulting in a mixed configuration. To extract modal parameters such as natural frequencies, mode shapes and damping ratios from a series of vibration records at each floor, the most advanced operational system identification methods based on frequency- and time-domain like FDD, pLSCF and SSI were applied. Extracted frequencies and mode shapes from the different identification methods showed a greater consistency for three buildings, however the three lower frequencies extracted were 1.2 to 1.7 times as stiff as those obtained using the initial FE models. Comparing the extracted fundamental periods with those estimated from the code equations and FE analysis, the FE analysis results showed the most flexible behavior, and the most simple equation that considers the building height as the only parameter correlated fairly well with test results. It is recognized that such a discrepancy arises from the fact that the present tests exclude the stiffness decreasing factors like concrete cracking, while the FE models ignore the stiffness increasing factors, such as the contribution of non-structural elements and the actual material properties used.

Ultimate Strength and Design Method of Turn-buckle for Measuring Tensile Force (인장력 측정용 턴버클의 극한강도 및 설계방법)

  • Lee, Swoo Heon;Shin, Kyung Jae;Lee, Hee Du
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.1
    • /
    • pp.61-70
    • /
    • 2013
  • A turn-buckle is capable of adjusting the tensile force by left-hand threads and right-hand threads between tension members. There are different types of turn-buckles according to tension member and connection form but the practical and existing turn-buckles are incapable of measuring the tensile force. A turn-buckle for adjusting and measuring tensile force has therefore been developed. This study shows the ultimate strength and reliability for measurement of the new turn-buckles through finite element analysis of the developed ones. From analytic results of the new turn-buckles which have the measurement limit loads of 100kN, 200kN and 300kN, the ultimate strength is approximately five times stronger than the measurement limit capacity. Additionally, a review of the new turn-buckle, which has the measurement limit load of over 300kN, shows that there is a tendency for the size of turn-buckle to become larger. So the connection devices were designed and the loading test was conducted from the concept that the parallel connection of turn-buckle with 300kN capacity can measure the tensile force of 600kN. The results of parallel loading test show the sufficient possibility. Furthermore, the mock-up test was constructed to investigate the release of initial load and corrosion when the new turn-buckle is installed at the outdoor and exposed to rain and atmosphere.

Structural stability analysis of nonlocal Megneto-Electro-Elastic(MEE) nano plates on elastic foundation (탄성지반위에 놓인 비국소 자기-전기-탄성 나노 판의 구조안정해석)

  • Han, Sung-Cheon;Park, Weon-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.52-60
    • /
    • 2017
  • This study examined the structural stability of nonlocal magneto-electro-elastic nano plates on elastic foundations using first-order shear deformation theory. Navier's method has been used to solve the buckling loads for all edges simply supported boundary conditions. On the other hand, biaxial buckling analysis of nano-plates has beenrarely studied. According to the Maxwell equation and the magneto-electro boundary condition, the change inthe magnetic and electric potential along the thickness direction of the magneto-electro-elastic nano plate wasdetermined. To reformulate the elasticity theory of the magneto- electro-elastic nano plate, the differential constitutive equation of Eringen was used and the governing equation of the nonlocal elasticity theory was studied using variational theory. The effects of the elastic foundation arebased on Pasternak's assumption. The relationship between nonlocal theory and local theory was analyzed through calculation results. In addition, structural stability problems were investigated according to the electric and magnetic potentials, nonlocal parameters, elastic foundation parameters, and side-to-thickness ratio. The results of the analysis revealedthe effects of the magnetic and electric potential. These calculations can be used to compare future research on new material structures made of magneto-electro-elastic materials.

Evaluation of Reliability of Strain Gauge Measurements for Geosynthetics (토목섬유 보강재에 적용한 스트레인게이지 실측값의 신뢰성 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Li, Zhuang;Kim, Uk-Gie
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.4
    • /
    • pp.87-96
    • /
    • 2015
  • Geosynthetics are widely used in different ways such as reinforcement of structures in road, railway, harbor and dam engineering, drainage, separation and erosion prevention. They are especially applied to reinforced retaining wall and slope or ground reinforcement. Recently, geosynthetics reinforced pile supported (GRPS) embankment was developed to improve stability and construability of embankments in railway engineering. Extension strains are usually measured by strain gauges adhered to geosynthetics to evaluate the stability of geosynthetics. However, the measurements are influenced by manufacturing method and stiffness of geosynthetics and also adherence of strain gauge. In this study, wide-width tensile strength tests were performed on three types of geosynthetics including geogrid, woven geotextile and non-woven geotextile. During the test, strains of geosynthetics were measured by both video extensometer and strain gauges adhered to the geosynthetics and the measured results were compared. Results show that the measured results by strain gauges have high reliability in case of large stiffness geosythetics like geogrid and woven geotextile, whereas they have very low reliability for small stiffness geosythetics like non-woven geotextile.