• Title/Summary/Keyword: 증강계수

Search Result 43, Processing Time 0.026 seconds

Numerical Analysis of Nonlinear Shoaling Process of Random Waves - Centered on the Evolution of Wave Height Distribution at the Varying Stages of Shoaling Process (불규칙 파랑 비선형 천수 과정 수치해석 - 천수 단계별 파고분포 변화를 중심으로)

  • Kim, Yong Hee;Cho, Yong Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.2
    • /
    • pp.106-121
    • /
    • 2020
  • In order to make harbor outskirt facilities robust using the reliability-based design, probabilistic models of wave heights at varying stage of shoaling process optimized for Korean sea waves are prerequisite. In this rationale, we numerically simulate the nonlinear shoaling process of random waves over the beach with a sandbar at its foreshore. In doing so, comprehensive numerical models made of spatially filtered Navier-Stokes Eq., LES [Large Eddy Simulation], dynamic Smagorinsky turbulence closure were used. Considering the characteristics of swells observed at the east coast of Korean Peninsula, random waves were simulated using JONSWAP wave spectrum of various peak enhancement coefficients and random phase method. The coefficients of probabilistic models proposed in this study are estimated from the results of frequency analysis of wave crests and its associated trough detected by Wave by Wave Analysis of the time series of numerically simulated free surface displacements based on the threshold crossing method. Numerical results show that Modified Glukhovskiy wave height distribution, the most referred probabilistic models at finite water depth in the literature, over-predicts the occurring probability of relatively large and small wave heights, and under predicts the occurrence rate of waves of moderate heights. On the other hand, probabilistic models developed in this study show vary encouraging agreements. In addition, the discrepancy of the Modified Glukhovskiy distribution from the measured one are most visible over the surf zone, and as a result, the Modified Glukhovskiy distribution should be applied with caution for the reliability-based design of harbor outskirt facilities deployed near the surf-zone.

Matrix Effects on X-Ray Fluorescence Intensities in Fe-Ni-Cr System (철-니켈-크롬 三成分系에서 X-線 螢光의 매트릭스 效果에 관한 硏究)

  • Yang Che-Hyon;Yeh Jin-Hae
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.10
    • /
    • pp.861-866
    • /
    • 1993
  • In general, the concentration of constituents can be more accurately measured in x-ray fluorescence analysis of Fe-Ni-Cr alloy by reducing and correcting the matrix effect with standard ingot samples. Because of the difficult the treatment at a high temperature in preparing the ingot samples of various concentrations, several standard specimens were prepared by mixing the powders of the metallic oxides in certain proportions and pressing them with a costant pressure. With the metallic oxide specimens thus obtained, different matrix coefficients were calculate from the intensities of the strength of the x-ray fluorescence and the concentration of the substances. It is found that effects of Fe and Cr on Ni are absorption rich and effects of Fe and Ni on Cr are enhancement rich, whereas Ni enhances Fe Fluorescence but Cr absorves Fe K${\alpha}$ line. And the x-ray fluorescence intensities were compared and analyzed between the metallic oxides and the ingot samples.

  • PDF

Contrast Optimization using of Weight-based Injection Protocol in Pediatric Abdomen CT Examination (소아 복부 CT 검사에서 체중에 기반한 조영제 주입 프로토콜 적용에 따른 조영증강의 최적화)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.575-584
    • /
    • 2021
  • The aim of this study was to achieve optimal portal phase while reducing contrast medium by applying weight-based dose protocol compared to standard fixed dose protocol to performing of pediatric abdominal CT examination. Discovery 750HD (General Electric Medical Systems, Milwaukee, USA) was used, and a total of 167 children consisting of 85 men and 82 women under the age of 18 were studied. The group in which the 300 mgI/ml(Xenetix, Guerbet, France) contrast medium was fixedly injected at twice body weight and the group injected with physiological saline while gradually decreasing the injection amount by 10% while applying the weight-based protocol were distinguished. Also, the CT number and SNR of abdominal organs were compared and evaluated while changing the scan delay time. Subjective image quality of enhancement and beam-hardening artifacts of around the heart was assessed with five-point criterion. The group adapted weight-based protocol with 20% reduction in contrast medium was most similar in contrast enhancement in the group with fixed injection at twice body weight. Furthermore, the group with a delay time of 20% had the highest contrast enhancement effect, and the difference in CT attenuation coefficient from the group scanned immediately after injection of the contrast media. Therefore, the appropriate delay time after injection of the contrast agent increased the contrast enhancement of the parenchymal organ. In addition, the weight-based injection protocol with normal saline reduced artifacts around the heart, and the effect of contrast enhancement could be maintained. In conclusion, it is possible to reduce dosage of contrast media through the application of weight-based injection protocols and appropriate latency, and to characterize optimal portal phase imaging on pediatric abdominal CT.

Simulation of lesion-to-liver contrast difference curves in Dynamic Hepatic CT with Pharmacokinetic Compartment Modeling (Pharmacokinetic Compartment Modeling을 이용한 나선식 CT에서의 간암-간 대조 곡선의 Simulation)

  • S.J. Kim;K.H. Lee;J.H. Kim;J.K. Han;B.G. Min
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.173-182
    • /
    • 1999
  • Contrast-enhanced CT has an important role in assessing liver lesions, the optimal protocol to get most effective result is not clear. The mein goal when deciding injention protocol is to optimize lesion detectability with rapid scanning when lesion to liver contrast is maximum. For this purpose, we developed a physiological model of the contrast medium enhancement based on the compartment modeling and pharmacokinetics. Blood supply to liver is achieved in two paths. This dual supply characteristic distinguishes the CT enhancement of liver from that of the other organs. The first path is by hepatic artery and to second, by portal vein. However, it is assumed that only gepatic artery can supply blood to hepatocellular carcinoma(HCC) compartment, thus, the difference of contrast enhancement is resulted between normal liver tissue and hepatic tumor. By solving differential equations for each compartment simultaneously using the computer program Matlab, CT contrast-enhancement curves were simulated. The simulated enhancement curves for aortic, hepatic, portal vein, and HCC compartments were compared with the mean enhancement curves from 24 patients exposed to the same protocols as the simulation. These enhancement curves showed a good agreement. Furthermore, we simulated lesion-to-liver curves for various injection protocols, and the effects were analyzed. The variables to be considered in the injection protocol were injection rate, dose, and concentration of contrast material. These data may help to optimize scanning protocols for better diagnosis.

  • PDF

Preoperative Prediction of Ductal Carcinoma in situ Underestimation of the Breast using Dynamic Contrast Enhanced and Diffusion-weighted Imaging (역동적 유방 자기공명 영상 및 확산 강조영상을 이용한 관상피내암종 저평가 수술전 예측)

  • Park, Mina;Kim, Eun-Kyung;Kim, Min Jung;Moon, Hee Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.101-109
    • /
    • 2013
  • Objective: To investigate roles of dynamic contrast enhanced magnetic resonance (DCE MR) and diffusion-weighted (DW) imaging in preoperative prediction of underestimation of ductal carcinoma in situ (DCIS) ${\geq}2cm$ on US guided core needle biopsy. Materials and Methods: Twenty two patients with DCIS on US-guided 14 gauge core needle biopsy were included. Patients were divided into a group with and without DCIS underestimation based on histopathology. MR images including DCE and DW imaging were obtained with a 3.0-T MR. The lesion type (mass or non-mass), enhancement pattern, peak enhancement, and apparent diffusion coefficient (ADC) values of proven malignant masses were generated using software of CADstream and compared between two groups using Fisher's exact test and Mann Whitney test. Results: Eight patients were in the group with underestimation and 14 patients were in the group without underestimation. The lesion type and enhancement pattern were not different between two groups (P values = 1.000 and 0.613, respectively). The median peak enhancement of lesions with underestimation was 159.5%, higher than 133.5% of those without underestimation, but not significant (P value = 0.413). The median ADC value of lesions with underestimation was $1.26{\times}10^{-3}mm^2/sec$, substantially lower than $1.35{\times}10^{-3}mm^2/sec$ of those without underestimation (P value = 0.094). Conclusion: ADC values had the potential to preoperatively predict DCIS underestimation on US-guided core needle biopsy, although a large prospective series study should be conducted to confirm these results.

Effects of Stocking and Laboratory Rearing in Abalone, Haliotis discus hannai by Tagging (참전복, Haliotis discus hannai 표식개체의 실내사육 및 방류효과)

  • Kang, Kyoung-Ho;Wi, Chong-Hwan;Kim, Kwang-Soo
    • Journal of Aquaculture
    • /
    • v.9 no.2
    • /
    • pp.109-115
    • /
    • 1996
  • Tagging method, recapture frequencies and mortalities were investigated to obtain the basic data for the effective release technique of abalone, Haliotis discus hannai. Tagged and untagged H. discus hannai were reared for 90 days in the laboratory. Attachment of plastic piece by Alteco was used as tag material. The growth, mortality and falling rate of tags were examined. Data from stock in natural condition showed that fishing rate, fishing mortality and natural mortality of tagged group were 0.04, 0.0195 and 0.4652, respectively.

  • PDF

Magnetic Resonance Characteristics of Ischemic Brain Infarction in Three Dogs (자기공명영상을 이용한 개의 허혈성 뇌경색의 진단 3례)

  • Lee, Ki-Ja;Kim, Young-Whan;Choi, Sung-Jin;Choi, Soo-Young;Jeong, In-Seong;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.31 no.5
    • /
    • pp.457-460
    • /
    • 2014
  • This case study describes the magnetic resonance characteristics of brain infarction in three dogs. Locations of the brain infarcts were cerebella, thalamus, and multifocal. The infarcts were sharply demarcated from adjacent brain parenchyma, homogeneous, T1-hypointense, T2-hyperintense with/without contrast enhancement, and minimal or no mass effect. Diffusion-weighted imaging (DWI) sequences were available in a dog and the infarcts were hyperintense on DWI and were hypointense on the apparent diffusion coefficient map.

Experimental Study on Deflection Evaluation of KCI specification and Eurocode 2 (콘크리트 구조 설계기준과 Eurocode 2의 처짐 산정에 관한 실험적 고찰)

  • Lee, In-Ju;Kim, Tae-Wan;Oh, Seok-Mim;Kim, Jun-Won;Park, Sun-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.141-144
    • /
    • 2008
  • Deflection in terms of serviceability of reinforced concrete structures is considered as one of significant factor. Domestic concrete specification offers a procedure to evaluate deflection using effective moment of inertia at cracked section, which has been known as Branson's equation in ACI. Branson's equation was derived from statistical analysis of maximum deflection of flexural members, but is somewhat weak in no reflection of bond characteristics between reinforced bars and concrete, such as tension stiffening effect. Therefore, present code creates difference from actual deflection. In this study, experiments about deflection of RC beams was completed to compare domestic standard and Eurocode 2, which calculates deflection considering tension stiffening effect. Four RC beams were built and tested, and initial modulus of elasticity and tensile strength of concrete used in the test was calculated by each design standard.

  • PDF

Improving prediction performance of network traffic using dense sampling technique (밀집 샘플링 기법을 이용한 네트워크 트래픽 예측 성능 향상)

  • Jin-Seon Lee;Il-Seok Oh
    • Smart Media Journal
    • /
    • v.13 no.6
    • /
    • pp.24-34
    • /
    • 2024
  • If the future can be predicted from network traffic data, which is a time series, it can achieve effects such as efficient resource allocation, prevention of malicious attacks, and energy saving. Many models based on statistical and deep learning techniques have been proposed, and most of these studies have focused on improving model structures and learning algorithms. Another approach to improving the prediction performance of the model is to obtain a good-quality data. With the aim of obtaining a good-quality data, this paper applies a dense sampling technique that augments time series data to the application of network traffic prediction and analyzes the performance improvement. As a dataset, UNSW-NB15, which is widely used for network traffic analysis, is used. Performance is analyzed using RMSE, MAE, and MAPE. To increase the objectivity of performance measurement, experiment is performed independently 10 times and the performance of existing sparse sampling and dense sampling is compared as a box plot. As a result of comparing the performance by changing the window size and the horizon factor, dense sampling consistently showed a better performance.

Utility of the 16-cm Axial Volume Scan Technique for Coronary Artery Calcium Scoring on Non-Enhanced Chest CT: A Prospective Pilot Study (비 조영증강 흉부 CT에서 관상동맥 칼슘스코어 측정을 위한 16 cm 축상 촬영 기법의 유용성: 전향적 탐색적 연구)

  • So Jung Ki;Chul Hwan Park;Kyunghwa Han;Jae Min Shin;Ji Young Kim;Tae Hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1493-1504
    • /
    • 2021
  • Purpose This study aimed to evaluate the utility of the 16-cm axial volume scan technique for calculating the coronary artery calcium score (CACS) using non-enhanced chest CT. Materials and Methods This study prospectively enrolled 20 participants who underwent both, non-enhanced chest CT (16-cm-coverage axial volume scan technique) and calcium-score CT, with the same parameters, differing only in slice thickness (in non-enhanced chest CT = 0.625, 1.25, 2.5 mm; in calcium score CT = 2.5 mm). The CACS was calculated using the conventional Agatston method. The difference between the CACS obtained from the two CT scans was compared, and the degree of agreement for the clinical significance of the CACS was confirmed through sectional analysis. Each calcified lesion was classified by location and size, and a one-to-one comparison of non-contrast-enhanced chest CT and calcium score CT was performed. Results The correlation coefficients of the CACS obtained from the two CT scans for slice thickness of 2.5, 1.25, and 0.625 mm were 0.9850, 0.9688, and 0.9834, respectively. The mean differences between the CACS were -21.4% at 0.625 mm, -39.4% at 1.25 mm, and -76.2% at 2.5 mm slice thicknesses. Sectional analysis revealed that 16 (80%), 16 (80%), and 13 (65%) patients showed agreement for the degree of coronary artery disease at each slice interval, respectively. Inter-reader agreement was high for each slice interval. The 0.625 mm CT showed the highest sensitivity for detecting calcified lesions. Conclusion The values in the non-contrast-enhanced chest CT, using the 16-cm axial volume scan technique, were similar to those obtained using the CACS in the calcium score CT, at 0.625 mm slice thickness without electrocardiogram gating. This can ultimately help predict cardiovascular risk without additional radiation exposure.